scholarly journals Applications of Ceramic Coating on the Turbine Blades of the AGTJ-100B

Author(s):  
Kazuo Uchida ◽  
Akinori Koga ◽  
Kiyomi Teshima ◽  
Masashi Arai

In 1978, the Japanese government started a national project for energy conservation called the Moonlight Project. The Engineering Research Association for Advanced Gas Turbines was selected to research and develop an advanced gas turbine for this project. The development stages were planned as follows: First, the development of a reheat gas turbine for a pilot plant (AGTJ-100A), and second, a prototype plant (AGTJ-100B). The AGTJ-100A has been undergoing performance tests since 1984 at the Sodegaura Power Station of the Tokyo Electric Power Co., Inc. (TEPCO). The inlet gas temperature of the high pressure turbine (HPT) of the AGTJ-100A is 1573K, while that of the AGTJ-100B is 100K higher. Therefore, various advanced technologies have to be applied to the AGTJ-100B HPT. Ceramic coating on the HPT blades is the most desirable of these technologies. In this paper, the present situation of development, as well as future R & D plans for ceramic coating will be described.

Author(s):  
Kazuo Takeya ◽  
Hajime Yasui

In 1978, the Japanese government started a national project for energy conservation called the Moonlight Project. The Engineering Research Association for Advanced Gas Turbines was selected to research and develop an advanced gas turbine for this project. The development stages were planned as follows: First, the development of a reheat gas turbine for a pilot plant (AGTJ-100A), and second, a prototype plant (AGTJ-100B). The AGTJ-100A has been undergoing performance tests since 1984 at the Sodegaura Power Station of the Tokyo Electric Power Co., Inc. (TEPCO). The inlet gas temperature of the high pressure turbine (HPT) of the AGTJ-100A is 1573K, while that of the AGTJ-100B is 100K higher. Therefore, various advanced technologies have to be applied to the AGTJ-100B HPT. Ceramic coating on the HPT blades is the most desirable of these technologies. In this paper, the present situation of development, as well as future R & D plans for ceramic coating, is taken into consideration. Steam blade cooling is applied for the IGSC.


1988 ◽  
Vol 110 (2) ◽  
pp. 220-224 ◽  
Author(s):  
K. Takeya ◽  
H. Yasui

In 1978, the Japanese government started a national project for energy conservation called the Moonlight Project. The Engineering Research Association for Advanced Gas Turbines was selected to research and develop an advanced gas turbine for this project. The development stages were planned as follows: first, the development of a reheat gas turbine for a pilot plant (AGTJ-100A), and second, a prototype plant (AGTJ-100B). The AGTJ-100A has been undergoing performance tests since 1984 at the Sodegaura Power Station of the Tokyo Electric Power Co., Inc. (TEPCO). The inlet gas temperature of the high-pressure turbine (HPT) of the AGTJ-100A is 1573 K, while that of the AGTJ-100B is 100 K higher. Therefore, various advanced technologies have to be applied to the AGTJ-100B HPT. Ceramic coating on the HPT blades is the most desirable of these technologies. In this paper, the present level of development, and future R & D plans for ceramic coating, are taken into consideration. Steam blade cooling is applied for the IGSC.


Author(s):  
Reiner Anton ◽  
Brigitte Heinecke ◽  
Michael Ott ◽  
Rolf Wilkenhoener

The availability and reliability of gas turbine units are critical for success to gas turbine users. Advanced hot gas path components that are used in state-of-the-art gas turbines have to ensure high efficiency, but require advanced technologies for assessment during maintenance inspections in order to decide whether they should be reused or replaced. Furthermore, advanced repair and refurbishment technologies are vital due to the complex nature of such components (e.g., Directionally Solidified (DS) / Single Crystal (SC) materials, thin wall components, new cooling techniques). Advanced repair technologies are essential to allow cost effective refurbishing while maintaining high reliability, to ensure minimum life cycle cost. This paper will discuss some aspects of Siemens development and implementation of advanced technologies for repair and refurbishment. In particular, the following technologies used by Siemens will be addressed: • Weld restoration; • Braze restoration processes; • Coating; • Re-opening of cooling holes.


1981 ◽  
Vol 103 (4) ◽  
pp. 772-775 ◽  
Author(s):  
Akifumi Hori ◽  
Kazuo Takeya

A new reheat gas turbine system is being developed as a national project by the “Engineering Research Association for Advanced Gas Turbines” of Japan. The machine consists of two axial flow compressors, three turbines, intercooler, combustor and reheater. The pilot plant is expected to go into operation in 1982, and a prototype plant will be set up in 1984. The major objective of this reheat gas turbine is application to a combined cycle power plant, with LNG burning, and the final target of combined cycle thermal efficiency is to be 55 percent (LHV).


1982 ◽  
Vol 104 (1) ◽  
pp. 1-8 ◽  
Author(s):  
Kenji Mori ◽  
Junichi Kitajima ◽  
Takeshi Kimura ◽  
Sansei Miki

Feasibility studies carried out by the Engineering Research Association for Advanced Gas Turbines under the sponsorship of the Agency of Industrial Science and Technology of Japan have indicated that the thermal efficiency of the combined cycle plant incorporating a high temperature reheat gas turbine and a steam turbine can exceed 50 percent. One of the engine components being investigated is the high temperature reheat combustor which will operate under high temperature (973 K) and heavily vitiated (12.4 percent O2) inlet-air conditions. This paper describes the design considerations on the reheat combustor and the results of the near-atomospheric pressure tests (0.1 ∼ 0.3 MPa) under vitiated conditions, using a conventional can-type combustor and a full scale model of the reheat combustor. Effects of air vitiation on inflammability limits, combustion efficiency, NOx and wall temperatures of gas turbine combustors are discussed.


1974 ◽  
Vol 96 (2) ◽  
pp. 129-133 ◽  
Author(s):  
V. I. Hanby

The rate of formation of gaseous sodium sulphate from sodium chloride and the combustion of a sulphur-bearing fuel has been investigated in a controlled mixing history combustor. The reaction was studied in the residence time range 0–16 millisec to simulate conditions resembling those in a gas turbine combustion chamber. The results show that under the conditions investigated, gas temperature was the most significant variable affecting the reaction rate. Gas phase formation of sodium sulphate proceeds too slowly to contribute to sulphatic corrosion in the short residence times which occur in gas turbine combustion chambers. The results obtained, in conjunction with predictions of salt particle behavior in the gas turbine engine indicate that the deposition process on turbine blades occurs via passage of transient high concentrations of particles through the engine.


Author(s):  
Hafiz M Hassan ◽  
Adeel Javed ◽  
Asif H Khoja ◽  
Majid Ali ◽  
Muhammad B Sajid

A clear understanding of the flow characteristics in the older generation of industrial gas turbines operating with silo combustors is important for potential upgrades. Non-uniformities in the form of circumferential and radial variations in internal flow properties can have a significant impact on the gas turbine stage performance and durability. This paper presents a comprehensive study of the underlying internal flow features involved in the advent of non-uniformities from twin-silo combustors and their propagation through a single axial turbine stage of the Siemens v94.2 industrial gas turbine. Results indicate the formation of strong vortical structures alongside large temperature, pressure, velocity, and flow angle deviations that are mostly located in the top and bottom sections of the turbine stage caused by the excessive flow turning in the upstream tandem silo combustors. A favorable validation of the simulated exhaust gas temperature (EGT) profile is also achieved via comparison with the measured data. A drop in isentropic efficiency and power output equivalent to 2.28% points and 2.1 MW, respectively is observed at baseload compared to an ideal straight hot gas path reference case. Furthermore, the analysis of internal flow topography identifies the underperforming turbine blading due to the upstream non-uniformities. The findings not only have implications for the turbine aerothermodynamic design, but also the combustor layout from a repowering perspective.


Author(s):  
Keisuke Makino ◽  
Ken-Ichi Mizuno ◽  
Toru Shimamori

NGK Spark Plug Co., Ltd. has been developing various silicon nitride materials, and the technology for fabricating components for ceramic gas turbines (CGT) using theses materials. We are supplying silicon nitride material components for the project to develop 300 kW class CGT for co-generation in Japan. EC-152 was developed for components that require high strength at high temperature, such as turbine blades and turbine nozzles. In order to adapt the increasing of the turbine inlet temperature (TIT) up to 1,350 °C in accordance with the project goals, we developed two silicon nitride materials with further unproved properties: ST-1 and ST-2. ST-1 has a higher strength than EC-152 and is suitable for first stage turbine blades and power turbine blades. ST-2 has higher oxidation resistance than EC-152 and is suitable for power turbine nozzles. In this paper, we report on the properties of these materials, and present the results of evaluations of these materials when they are actually used for CGT components such as first stage turbine blades and power turbine nozzles.


Author(s):  
SS Talebi ◽  
AM Tousi ◽  
A Madadi ◽  
M Kiaee

Recently, the utilization of micro gas turbines in smart grids are rising that makes the part-load operation principal situation of the engine service. This leads to faster life consumption that increases the importance of the diagnostics process. Gas path analysis is an effective method for gas turbine diagnostics. Complex dynamics of gas turbine induces challenging conditions to perform applicable gas path analysis. This study aims to facilitate MGT gas path diagnostics through reducing the number of monitoring parameters and preparation a pattern for engine level and component level health assessment in both full and part load operation of a recuperated micro gas turbine. To attain this goal a model is proposed to simulate MGT off-design performance which is validated against experimental data in healthy and degraded operation modes. Fouling in compressor, turbine and recuperator and erosion in compressor and turbine as the most common degradations in the gas turbine are considered. The fault simulation is performed by changing the health parameters of gas path components. According to the result investigation, a matrix comprises deviation contours of four parameters, Power, fuel flow, compressor discharge pressure, and exhaust gas temperature is presented and analyzed. The analysis shows that monitoring these parameters makes it possible to perform engine level and component level diagnostics through evaluating a binary code (generated by mentioned parameter variations) against the fault effects pattern in different load fractions and fault severities. The simulation also showed that the most power drop occurred under the compressor fouling by about 8.7% while the most reduction in thermal efficiency is observed under recuperator fouling by about 7.84%. Furthermore, the investigation showed the maximum decrease in the surge margin induced by the compressor fouling during the lower part-load operation by about 45.7% while in the higher loads created by the turbine fouling by about 14%.


Sign in / Sign up

Export Citation Format

Share Document