scholarly journals Heat Transfer in Adjacent Interacting Impinging Synthetic Jets

Author(s):  
Tim Persoons ◽  
Tadhg S. O’Donovan ◽  
Darina B. Murray

An impinging synthetic jet can attain heat transfer rates comparable to a continuous jet, without net mass input. However it needs a forced cross-flow to supply fresh cooling medium. The vectoring effect of adjacent synthetic jets allows directing the flow by changing the phase between the jets. This study uses the vectoring effect of two adjacent synthetic jets to draw in fresh air, while maintaining high impingement cooling performance. The experimental approach applies infrared thermography and particle image velocimetry to quantify the local convective heat transfer and flow field, respectively. The heat transfer profiles for various phase differences have been compared to the mean flow field and wall-normal velocity fluctuation intensity. For a fixed operating point (stroke length and Reynolds number) and geometry, the cooling performance has been optimised for phase and jet-to-surface spacing, resulting in about 90% enhancement of the maximum and overall cooling rate compared to a single jet, without the need for external cross-flow forcing.

2015 ◽  
Vol 23 (03) ◽  
pp. 1550024 ◽  
Author(s):  
Omidreza Ghaffari ◽  
Muhammad Ikhlaq ◽  
Mehmet Arik

According to recent trends in the field of miniature electronics, the need for compact cooling solutions compatible with very thin profiles and small footprint areas is inevitable. Impinging synthetic jets are recognized as a promising technique for cooling miniature surfaces like laptops, tablets, smart phones and slim TV systems. Effect of jet to cooled surface spacing is crucial in cooling performance as well as predicting Nusselt number for such spacing. An experimental study has been performed to investigate the cooling performance of two different synthetic jets actuated with piezoelectric actuators cooling over a vertical surface. Results showed that a major degradation of heat transfer when jets are close to the surface is occurred. Slot synthetic jets showed a better performance in terms of coefficient of performance (COP) than semi-confined circular jets for small jet to surface spacing. Later, a correlation is proposed for predicting Nu number for a semi-confined circular synthetic jet accounting the effects of Re number ([Formula: see text]), jet-to-surface spacing ([Formula: see text] and [Formula: see text]) and the stroke length ([Formula: see text] and [Formula: see text]). It is found that correlation can provide predictions with an [Formula: see text] value of over 98%.


Author(s):  
Rayhaan Farrelly ◽  
Alan McGuinn ◽  
Tim Persoons ◽  
Darina B. Murray

A study has been carried out to compare steady jet and synthetic jet heat transfer distributions at low Reynolds numbers. Both jets issued from a 5mm diameter orifice plate with air for the steady jet being supplied by a compressor via a plenum chamber. Tests were conducted for Reynolds numbers ranging from 1000 to 4000, and for non-dimensional surface to jet exit spacings (H/D) from 1 to 6. Dimensionless stroke length (Lo/D) for the synthetic jet was held constant at 8. A significant difference was observed between the steady and synthetic jet Nusselt numbers at low Reynolds numbers and low H/D. In comparison to steady jets, the stronger entrainment of surrounding fluid and the vigorous mixing near the impingement surface are characteristics of synthetic jets that are beneficial to heat transfer. Nonetheless, the steady jet yields higher Nusselt numbers for all test conditions.


Author(s):  
Farzad Bazdidi–Tehrani ◽  
Ali Saadniya ◽  
Soroush Rashidzadeh

Nowadays, synthetic jets have various applications such as cooling enhancement and active flow control. In the present paper, the capability of two turbulence modelling approaches in predicting thermal performance of an impinging synthetic jet is investigated. These two approaches are scale adaptive simulation (SAS) and detached eddy simulation (DES). Comparisons between numerical data and experimental studies reveal that the ability of DES in predicting the asymmetrical trend of heat transfer profiles is better than SAS in almost all the study cases. Although, near the stagnation zone, the performance of SAS is superior. Results show that the effects of parameters such as frequency, cross-flow velocity and suction duty cycle factor are well predicted by both approaches. An increase of cross-flow velocity from 1.81 m/s to 2.26 m/s results in an improvement of [Formula: see text] near the stagnation point by almost 16.3% and 9.2% using DES and SAS, respectively.


Author(s):  
Alexander Sinclair ◽  
John Reizes ◽  
Victoria Timchenko ◽  
Gary Rosengarten

Laminar flow limits the mixing performance and heat transfer rates that occurs within microdevices. Synthetic jets in the microscale could disrupt laminar flow and improve the performance of such devices. In this paper a synthetic microjet integrated in a microchannel was designed and fabricated using micromachining techniques. The channel flow was driven by a syringe pump at a rate of 1.39μL/s and the device was actuated using a piezoceramic disc at a frequency of 600Hz. Flow fields were measured phase locked to the actuation cycle using the MicroPIV technique in the mid plane of the jet. The resultant fields revealed a jet with a largest velocity of 2.3m/s. The average velocity during expulsion was estimated to be 0.73m/s using a comparison to the oscillatory solution to flow in a square duct. Measurements at different phases in the cycle revealed a jet strong enough to impinge on the opposing wall and the growth and decay of a pair of vortices formed at the edge of the orifice. It was also shown that the synthetic jet significantly altered the flow patterns showing promising signs for enhancing mixing and heat transfer in microchannels.


Author(s):  
Rayhaan Farrelly ◽  
Alan McGuinn ◽  
Tim Persoons ◽  
Darina Murray

Impinging synthetic jets are considered as a potential solution for convective cooling, in applications that match their main characteristics (high local heat transfer rates, zero net mass flux, scalability, active control). Nevertheless the understanding of heat transfer to synthetic jets falls short of that available for steady jets. To address this, this paper uses detailed flow field measurements to help identify the main heat transfer mechanisms in impinging synthetic jets. Local heat transfer measurements have been performed for an impinging round synthetic jet at a range of Reynolds numbers between 1000 and 3000, nozzle to plate spacings between 4D and 16D and stroke lengths (L0) between 2D and 32D. The heat transfer results show evidence of distinct regimes in terms of L0/D and L0/H ratios. Based on appropriate scaling, four heat transfer regimes are identified which justifies a detailed study of the flow field characteristics. High speed particle image velocimetry (PIV) has been employed to measure the time-resolved velocity flow fields of the synthetic jet to identify the flow structures at selected L0/H values corresponding to the identified heat transfer regimes. The flow measurements support the same regimes as identified from the heat transfer measurements and provide physical insight for the heat transfer behaviour.


Author(s):  
Mehmet Arik ◽  
Yogen Utturkar ◽  
Mustafa Gursoy

Meso scale cooling devices have been of interest for low form factor, tight space, and high COP thermal management problems. A candidate meso scale device, known as synthetic jets, operates with micro fluidic principles and disturbs the boundary layer causing significant heat transfer over conventional free convective heat transfer in air. Previous papers have dealt with the impingement and cross flow, but did not study mixed convection for synthetic jet with natural convection. In the present study, we discuss the results of an experimental study to investigate the interplay between jet orientations with respect to gravity, elevated temperature conditions, and synthetic jet heat dissipation capacity. Experiments were performed by placing synthetic at different positions around a square, 25.4mm heated flat surface. The flow physics behind the experimental findings is discussed. It is found that impingement heat transfer outperformed more than 30% compared to other orientations. The jet showed about 15% sensitivity to angular orientations.


Author(s):  
Stefano Zecchi ◽  
Alessandro Bacci

Gas turbine performance is strongly affected by firing temperature; raising this parameter has always been one of the major development strategies in gas turbine technology. This trend requires enhancements in materials and cooling techniques in order to keep components temperatures within structural limits and to satisfy expected life requirements. Cooling techniques are proven to be very effective, and it justifies tremendous research efforts. Among these techniques, impingement cooling is widely used, especially in vane cooling. Impingement fluid dynamics is quite complex, and its understanding is still incomplete; moreover further improvements in impingement cooling performance are expected. A great amount of experimental investigations are available on the subject and recently more and more numerical analysis has been performed. Due to advances in computational fluid dynamics (CFD) and availability of commercial codes, numerical investigations are often used in industrial design methodologies. Therefore the present study has been carried out using a commercial code with a two equation turbulence model, as common in industry standard analyses. The aim of this work is to investigate a single jet with cross-flow, at several blowing rates, analysing both flow field and heat transfer. The cross-flow passes through a rectangular duct. The jet is injected on the upper surface from a circular pipe perpendicularly to the duct axis and impacts on the lower surface. Firstly, a comparison of results with experimental data available in literature is provided. This permits to characterize the numerical model, particularly with respect to mesh, boundary conditions, and turbulence model. Then the rectangular duct lower flat surface is replaced by a grooved one. A single groove, horse-shoe shaped and located slightly upstream the impinging region, is used to control the flow field near the impact surface. Effects of the groove on impingement cooling are investigated. Both fluid dynamic and heat transfer analyses are performed. Results show the groove to be effective in driving the flow field interaction between cross-flow and impinging jet; heat transfer is also affected by the groove.


Volume 4 ◽  
2004 ◽  
Author(s):  
Jivtesh Garg ◽  
Mehmet Arik ◽  
Stanton Weaver ◽  
Seyed Saddoughi

Micro fluidics devices are conventionally used for boundary layer control in many aerospace applications. Synthetic Jets are intense small scale turbulent jets formed from entrainment and expulsion of the fluid in which they are embedded. The idea of using synthetic jets in confined electronic cooling applications started in late 1990s. These micro fluidic devices offer very efficient, high magnitude direct air-cooling on the heated surface. A proprietary synthetic jet designed in General Electric Company was able to provide a maximum air velocity of 90 m/s from a 1.2 mm hydraulic diameter rectangular orifice. An experimental study for determining the thermal performance of a meso scale synthetic jet was carried out. The synthetic jets are driven by a time harmonic signal. During the experiments, the operating frequency for jets was set between 3 and 4.5 kHz. The resonance frequency for a particular jet was determined through the effect on the exit velocity magnitude. An infrared thermal imaging technique was used to acquire fine scale temperature measurements. A square heater with a surface area of 156 mm2 was used to mimic the hot component and extensive temperature maps were obtained. The parameters varied during the experiments were jet location, driving jet voltage, driving jet frequency and heater power. The output parameters were point wise temperatures (pixel size = 30 μm), and heat transfer enhancement over natural convection. A maximum of approximately 8 times enhancement over natural convection heat transfer was measured. The maximum coefficient of cooling performance obtained was approximately 6.6 due to the low power consumption of the synthetic jets.


Author(s):  
Bingran Li ◽  
Cunliang Liu ◽  
Lin Ye ◽  
Huiren Zhu ◽  
Fan Zhang

Abstract To investigate the application of ribbed cross-flow coolant channels with film hole effusion and the effects of the internal cooling configuration on film cooling, experimental and numerical studies are conducted on the effect of the relative position of the film holes and different orientation ribs on the film cooling performance. Three cases of the relative position of the film holes and different orientation ribs (post-rib, centered, and pre-rib) in two ribbed cross-flow channels (135° and 45° orientation ribs) are investigated. The film cooling performances are measured under three blowing ratios by the transient liquid crystal measurement technique. A RANS simulation with the realizable k-ε turbulence model and enhanced wall treatment is performed. The results show that the cooling effectiveness and the downstream heat transfer coefficient for the 135° rib are basically the same in the three position cases, and the differences between the local effectiveness average values for the three are no more than 0.04. The differences between the heat transfer coefficients are no more than 0.1. The “pre-rib” and “centered” cases are studied for the 45° rib, and the position of the structures has little effect on the film cooling performance. In the different position cases, the outlet velocity distribution of the film holes, the jet pattern and the discharge coefficient are consistent with the variation in the cross flow. The related research previously published by the authors showed that the inclination of the ribs with respect to the holes affects the film cooling performance. This study reveals that the relative positions of the ribs and holes have little effect on the film cooling performance. This paper expands and improves the study of the effect of the internal cooling configuration on film cooling and makes a significant contribution to the design and industrial application of the internal cooling channel of a turbine blade.


Sign in / Sign up

Export Citation Format

Share Document