Microfluidic Flow Control and Particle Transport Using Acoustically Actuated Bubbles in Teardrop Shaped Cavities

Author(s):  
Ali Hashmi ◽  
Garrett Heiman ◽  
Gan Yu ◽  
Hyuck-Jin Kwon ◽  
Jie Xu

It is well known that a symmetric microstreaming flow field will present in the vicinity of an acoustically actuated bubble. In this study, we demonstrate that oscillating microbubbles confined in teardrop-shaped cavities can result in a break in the symmetry of a microstreaming flow field. The teardrop cavity controls the size and shape of the bubble, regulating the volume and therefore its resonance frequency. If actuated in an acoustic field, the induced flow field can then be turned on and off by changing the acoustic actuation frequency. By harnessing the flow field directing capabilities of symmetry breaks and the switching properties of selective excitation of microbubbles, we generate and characterize a microfluidic switch for directing flow direction. We also show that a chain of multiple teardrop-shaped cavities can be used as a transport mechanism for directing particles spatially at high flow speeds. Our results demonstrate that teardrop cavities have great potential in future lab-on-a-chip devices by providing simple solutions to complex flow circuits for temporal and spatial flow control.

2011 ◽  
Vol 134 (3) ◽  
Author(s):  
Martin Elfert ◽  
Michael Schroll ◽  
Wolfgang Förster

The flow field characteristics of a two-pass cooling system with an engine-similar layout have been investigated experimentally using the nonintrusive particle image velocimetry (PIV). It consists of a trapezoidal inlet duct, a nearly rectangular outlet duct, and a sharp 180 deg turn. The system has been investigated with smooth and ribbed walls. Ribs are applied on two opposite walls in a symmetric orientation inclined with an angle of 45 deg to the main flow direction. The applied rib layout is well proven and optimized with respect to heat transfer improvement versus pressure drop penalty. The system rotates about an axis orthogonal to its centerline. The configuration was analyzed with the planar two-component PIV technique, which is capable of obtaining complete maps of the instantaneous as well as the averaged flow field even at high levels of turbulence, which are typically found in sharp turns, in ribbed ducts, and, especially, in rotating ducts. In the past, a slip between motor and channel rotation causes additional non-negligible uncertainties during PIV measurements due to an unstable image position. These were caused by the working principle of the standard programmable sequencer unit used in combination with unsteady variations in the rotation speed. Therefore, a new sequencer was developed using FPGA-based hardware and software components from National Instruments (NI), which revealed a significant increase in the stability of the image position. Furthermore, general enhancements of the operability of the PIV system were achieved. The presented investigations of the secondary flow were conducted in stationary and, with the new sequencer technique applied, in rotating mode. Especially in the bend region, vortices with high local turbulence were found. The ribs also change the fluid motion as desired by generating additional vortices impinging the leading edge of the first pass. The flow is turbulent and isothermal; no buoyancy forces are active. The flow was investigated at a Reynolds number of Re=50,000, based on the reference length d (see Fig. 3). The rotation numbers are Ro=0.0 (nonrotating) and 0.1. Engine relevant rotation numbers are in order of 0.1 and higher. A reconstruction of some test rig components, especially the model mounting, has become necessary to reach higher values of the rotational speed compared with previous investigations such as the work of Elfert et al. (2008, “Detailed Flow Investigation Using PIV in a Rotating Square-Sectioned Two-Pass Cooling System With Ribbed Walls,” ASME Turbo Expo, Berlin, Germany, Jun. 9–13, Paper No. GT-2008-51183). This investigation is aimed to analyze the complex flow phenomena caused by the interaction of several vortices, generated by rotation, flow turning, or inclined wall ribs. The flow maps obtained with PIV are of good quality and high spatial resolution and therefore provide a test case for the development and validation of numerical flow simulation tools with special regard to the prediction of flow turbulence under the rotational flow regime, which is typical of turbomachinery. Future work will include the investigation of buoyancy effects to the rotational flow. This implicates wall heating, which results from the heater glass in order to provide transparent models.


Author(s):  
M. Elfert ◽  
M. Schroll ◽  
W. Fo¨rster

The flow field characteristics of a two-pass cooling system with an engine-similar lay-out have been investigated experimentally using the non-intrusive Particle Image Velocimetry (PIV). It consists of a trapezoidal inlet duct, a nearly rectangular outlet duct, and a sharp 180 degree turn. The system has been investigated with smooth and ribbed walls. Ribs are applied on two opposite walls in a symmetric orientation inclined with an angle of 45 degrees to the main flow direction. The applied rib lay-out is well-proved and optimized with respect to heat transfer improvement versus pressure drop penalty. The system rotates about an axis orthogonal to its centreline. The configuration was analyzed with the planar two-component PIV technique (2C PIV), which is capable of obtaining complete maps of the instantaneous as well as the averaged flow field even at high levels of turbulence, which are typically found in sharp turns, in ribbed ducts and, especially, in rotating ducts. In the past, slip between motor and channel rotation causes additional not negligible uncertainties during PIV measurements due to unstable image position. These were caused by the working principle of the standard programmable sequencer unit used in combination with unsteady variations of the rotation speed. Therefore, a new sequencer was developed using FPGA-based hardware and software components from National Instruments which revealed a significant increase of the stability of the image position. Furthermore, general enhancements of the operability of the PIV system were achieved. The presented investigations of the secondary flow were conducted in stationary and, with the new sequencer technique applied, in rotating mode. Especially in the bend region vortices with high local turbulence were found. The ribs also change the fluid motion as desired by generating additional vortices impinging the leading edge of the first pass. The flow is turbulent and isothermal, no buoyancy forces are active. The flow was investigated at Reynolds number of Re = 50,000, based on the reference length d (see Fig. 3). The rotation number is Ro = 0 (non-rotating) and 0.1. Engine relevant rotation numbers are in order of 0.1 and higher. A reconstruction of some test rig components, especially the model mounting, has become necessary to reach higher values of the rotational speed compared to previous investigations like in Elfert [2008]. This investigation is aimed to analyze the complex flow phenomena caused by the interaction of several vortices, generated by rotation, flow turning or inclined wall ribs. The flow maps obtained with PIV are of good quality and high spatial resolution and therefore provide a test case for the development and validation of numerical flow simulation tools with special regard to prediction of flow turbulence under rotational flow regime as typical for turbomachinery. Future work will include the investigation of buoyancy effects to the rotational flow. This implicates wall heating which result from the heater glass in order to provide transparent models.


Actuators ◽  
2021 ◽  
Vol 10 (12) ◽  
pp. 326
Author(s):  
Andrea Palumbo ◽  
Luigi de Luca

The paper presents a joint experimental and numerical characterization of double-orifice synthetic jet actuators for flow control. Hot-wire measurements of the flow field generated by the device into a quiescent air environment were collected. The actuation frequency was systematically varied to obtain the frequency response of the actuator; its coupled resonance frequencies were detected and the velocity amplitude was measured. Direct numerical simulations (DNS) of the flow field generated by the device were subsequently carried out at the actuation frequency maximizing the jet output. The results of a fine-meshed parametric analysis are outlined to discuss the effect of the distance between the orifices: time-averaged flow fields show that an intense jet interaction occurs for small values of the orifice spacing-to-diameter ratio; phase-averaged velocity and turbulent kinetic energy distributions allow to describe the vortex motion and merging. A novel classification of the main regions of dual synthetic jets is proposed, based on the time- and phase-averaged flow behaviour both in the near field, where two distinct jets converge, and in the far field, where an unique jet is detected. The use of three-dimensional DNS also allows to investigate the vortex merging for low values of the jet spacing. The work is intended to provide guidelines for the design of synthetic jet arrays for separation control and impinging configurations.


Author(s):  
Mona Gomaa ◽  
Tamer Kasem

Water waves propagation over submerged obstacles is considered. The problem serves as an efficient model for modeling breakwaters. A numerical wave tank is developed to simulate the induced flow field. The model is based on multiphase viscous flow assumptions. Computations are performed adopting clustered grids and suitable initial and boundary conditions. The results are verified using the flow field particle image velocimetry (PIV) measurements. Spatial and temporal resolutions are validated. Complex flow phenomena occurring due to the presence of the relatively large sized obstacle are visualized. The effect of wave parameters on the flow structure is investigated. A brief parametric study is presented and the resultant wave forces and turning moments are provided.


Author(s):  
Aaron Costall ◽  
Ricardo F. Martinez-Botas ◽  
Dean Palfreyman

Automotive turbocharger turbines experience a highly unsteady and pulsating flow field due to the abrupt operation of the exhaust valves in a reciprocating internal combustion engine. Previous work has demonstrated and validated against experiment a computational model of a turbine stage under such conditions. The same model is used in the present paper to examine in greater detail the complex flow characteristics observed. The pulsating inlet condition results in a highly disturbed flow field in the turbine stage, the main features of which have already been identified. The effect of the passing of the blades at the volute tongue is observed, and the fluctuating velocity field in the blade passages is seen to lead to poor flow direction control at the turbine inlet and exit. The turbine geometry, calculated for steady flow, is forced to operate away from design conditions for most of the pulse period. Through a detailed analysis of the intricate flow field features at varying instants during the pulse period, this paper highlights areas of the blade geometry and periods in the pulse profile that should be investigated further, such that the integrated performance across the entire pulse cycle can be improved.


1988 ◽  
Vol 110 (2) ◽  
pp. 134-139 ◽  
Author(s):  
M. A. Ortega ◽  
J. T. Sielawa

The thermally induced flow field, in a rapidly rotating container consisting of a pair of coaxial cylinders bounded on the top and bottom by horizontal end plates, is considered. The top plate is heated and the bottom plate is cooled, both by small amounts, so that the thermal Rossby number is small, and the cylinders are supposed to be conductive. The induced velocity and temperature fields are determined by subdivision of the flow field; the equation for the central part, the inner core, is solved numerically as well as analytically.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1781
Author(s):  
Weiyu Lu ◽  
Xin Fu ◽  
Jinchun Wang ◽  
Yuanchi Zou

Vibration wall control is an important active flow control technique studied by many researchers. Although current researches have shown that the control performance is greatly affected by the frequency and amplitude of the vibration wall, the mechanism hiding behind the phenomena is still not clear, due to the complex interaction between the vibration wall and flow separation. To reveal the control mechanism of vibration walls, we propose a simplified model to help us understand the interaction between the forced excitation (from the vibration wall) and self-excitation (from flow instability). The simplified model can explain vibration wall flow control behaviors obtained by numerical simulation, which show that the control performance will be optimized at a certain reduced vibration frequency or amplitude. Also, it is shown by the analysis of maximal Lyapunov exponents that the vibration wall is able to change the flow field from a disordered one into an ordered one. Consistent with these phenomena and bringing more physical insight, the simplified model implies that the tuned vibration frequency and amplitude will lock in the unsteady flow separation, promote momentum transfer from the main stream to the separation zone, and make the flow field more orderly and less chaotic, resulting in a reduction of flow loss.


1994 ◽  
Author(s):  
D. Muthuvel Murugan ◽  
Widen Tabakoff ◽  
Awatef Hamed

Detailed flow investigation in the downstream region of a radial inflow turbine has been performed using a three component Laser Doppler Velocimetry. The flow velocities are measured in the exit region of the turbine at off-design operating conditions. The results are presented as contour and vector plots of mean velocities, flow angles and turbulent stresses. The measured parameters are correlated to the rotor blade rotation to observe any periodic nature of the flow. The measurements reveal a complex flow pattern near the tip region at the rotor exit due to the interaction of the tip clearance flow. The degree of swirl of the flow near the tip region at the rotor exit is observed to be high due to the gross under turning of the flow near the tip region. The effect of the rotor on the exit flow field is observed in the proximity of the rotor exit.


Author(s):  
Marcel Staats ◽  
Wolfgang Nitsche

We present results of experiments on a periodically unsteady compressor stator flow of the type which would be expected in consequence of pulsed combustion. A Reynolds number of Re = 600000 was used for the investigations. The experiments were conducted on the two-dimensional low-speed compressor testing facility in Berlin. A choking device downstream the trailing edges induced a periodic non-steady outflow condition to each stator vane which simulated the impact of a pressure gaining combuster downstream from the last stator. The Strouhal number of the periodic disturbance was Sr = 0.03 w.r.t. the stator chord length. Due to the periodic non-steady outflow condition, the flow-field suffers from periodic flow separation phenomena, which were managed by means of active flow control. In our case, active control of the corner separation was applied using fluidic actuators based on the principle of fluidic amplification. The flow separation on the centre region of the stator blade was suppressed by means of a fluidic blade actuator leading to an overall time-averaged loss reduction of 11.5%, increasing the static pressure recovery by 6.8% while operating in the non-steady regime. Pressure measurements on the stator blade and the wake as well as PIV data proved the beneficial effect of the active flow control application to the flow field and the improvement of the compressor characteristics. The actuation efficiency was evaluated by two figures of merit introduced in this contribution.


Sign in / Sign up

Export Citation Format

Share Document