ELASTIC BUCKLING OF THIN-WALLED CIRCULAR TUBES CONTAINING AN ELASTIC INFILL

2006 ◽  
Vol 06 (04) ◽  
pp. 457-474 ◽  
Author(s):  
M. A. BRADFORD ◽  
A. ROUFEGARINEJAD ◽  
Z. VRCELJ

Circular thin-walled elastic tubes under concentric axial loading usually fail by shell buckling, and in practical design procedures the buckling load can be determined by modifying the local buckling stress to account empirically for the imperfection sensitive response that is typical in Donnell shell theory. While the local buckling stress of a hollow thin-walled tube under concentric axial compression has a solution in closed form, that of a thin-walled circular tube with an elastic infill, which restrains the local buckling mode, has received far less attention. This paper addresses the local buckling of a tubular member subjected to axial compression, and formulates an energy-based technique for determining the local buckling stress as a function of the stiffness of the elastic infill by recourse to a transcendental equation. This simple energy formulation, with one degree of buckling freedom, shows that the elastic local buckling stress increases from 1 to [Formula: see text] times that of a hollow tube as the stiffness of the elastic infill increases from zero to infinity; the latter case being typical of that of a concrete-filled steel tube. The energy formulation is then recast into a multi-degree of freedom matrix stiffness format, in which the function for the buckling mode is a Fourier representation satisfying, a priori, the necessary kinematic condition that the buckling deformation vanishes at the point where it enters the elastic medium. The solution is shown to converge rapidly, and demonstrates that the simple transcendental formulation provides a sufficiently accurate representation of the buckling problem.

2021 ◽  
Vol 186 ◽  
pp. 106909
Author(s):  
Zannatul Mawa Dalia ◽  
Anjan K. Bhowmick ◽  
Gilbert Y. Grondin

2018 ◽  
Vol 8 (9) ◽  
pp. 1602 ◽  
Author(s):  
Zhao Yang ◽  
Chengxiang Xu

Local buckling in steel tubes was observed to be capable of reducing the ultimate loads of thin-walled concrete-filled steel-tube (CFST) columns under axial compression. To strengthen the steel tubes, steel bars were proposed in this paper to be used as stiffeners fixed onto the tubes. Static-loading tests were conducted to study the compression behavior of square thin-walled CFST columns with steel bar stiffeners placed inside or outside the tube. The effect and feasibility of steel bar stiffeners were studied through the analysis of failure mode, load–displacement relationship, ultimate load, ductility, and local buckling. Different setting methods of steel bars were compared as well. The results showed that steel-bar stiffeners proposed in this paper can be effective in delaying local buckling as well as increasing the bearing capacity of the columns, but will decrease the ductility of the columns. In order to obtain a higher bearing capacity of columns, steel bars with low stiffness should be placed inside and steel bars with high stiffness should be placed outside of the steel tubes. The study is helpful in providing reference to the popularization and application of this new structural measure to avoid or delay the local buckling of thin-walled CFST columns.


2019 ◽  
Vol 2019 ◽  
pp. 1-14
Author(s):  
He Zhang ◽  
Kai Wu ◽  
Chao Xu ◽  
Lijian Ren ◽  
Feng Chen

Two columns of thin-walled concrete-filled steel tubes (CFSTs), in which tube seams are connected by self-tapping screws, are axial compression tested and FEM simulated; the influence of local buckling on the column compression bearing capacity is discussed. Failure modes of square thin-wall CFST columns are, first, steel tube plate buckling and then the collapse of steel and concrete in some corner edge areas. Interaction between concrete and steel makes the column continue to withstand higher forces after buckling appears. A large deflection analysis for tube elastic buckling reflects that equivalent uniform stress of the steel plate in the buckling area can reach yield stress and that steel can supply enough designing stress. Aiming at failure modes of square thin-walled CFST columns, a B-type section is proposed as an improvement scheme. Comparing the analysis results, the B-type section can address both the problems of corner collapse and steel plate buckling. This new type section can better make full use of the stress of the concrete material and the steel material; this type section can also increase the compression bearing capacity of the column.


2018 ◽  
Vol 37 (9) ◽  
pp. 592-608 ◽  
Author(s):  
CY Zhu ◽  
YH Zhao ◽  
L Sun

The objective of this study is to investigate the seismic performance of fiber-reinforced polymer-reinforced concrete-filled thin-walled steel tube (CFTST). Twelve specimens with different fiber-reinforced polymer types (glass fiber-reinforced polymer and carbon fiber-reinforced polymer) and reinforcing modes were tested under constant axially compressive load and cyclic lateral load. The failure mode and lateral load versus displacement relationship for each specimen were recorded during testing. The strength, ductility, and energy dissipation capacity were analyzed accordingly. Further, a stress–strain relationship and a restoring force model of the fiber-reinforced polymer confining steel tube with local buckling were proposed. A hysteretic model for the fiber-reinforced polymer-reinforced CFTST was developed subsequently. The results indicate that the seismic performance of fiber-reinforced polymer-reinforced CFTST can be effectively improved by optimizing the fiber-reinforced polymer type and corresponding reinforcing scheme. Carbon fiber-reinforced polymer and glass fiber-reinforced polymer are suitable materials for the confinement and bending reinforcement of the column, respectively. The modeling results show the energy imported into the column is mainly dissipated by the thin-walled steel tube. The energy dissipation proportion of the steel tube, concrete core, and longitudinal fiber-reinforced polymer are >80%, 10%–20%, and <8%, respectively. The energy dissipation value of the steel tube can be improved more than 40% after effectively restraining the local buckling.


2008 ◽  
Vol 400-402 ◽  
pp. 551-557 ◽  
Author(s):  
Bao Zhu Cao ◽  
Yao Chun Zhang ◽  
Yue Ming Zhao

Experimental research on square and octagonal concrete filled thin-walled steel tube long columns of 6 specimens in axial compression and 8 specimens in eccentric compression is undertaken. The relationship of global buckling bearing capacity of the columns and local buckling of the steel tubes is obtained. The test indicates that local buckling occurs in steel tube of each column before it reaches ultimate capacity, and has little effect on global buckling performance. The ultimate load decreases obviously with the increase of slender ratio and eccentricity. The ductility of columns increases with the increase of steel ratio in composite sections. Composite beam element of ANSYS is adopted in the finite element analysis. The theoretical results are agreed well with test..


2013 ◽  
Vol 838-841 ◽  
pp. 439-443 ◽  
Author(s):  
Zhi Liang Zuo ◽  
Da Xin Liu ◽  
Jian Cai ◽  
Chun Yang ◽  
Qing Jun Chen

To improve the mechanical behavior of T-shaped concrete-filled steel tubular (T-CFT) column, the method that setting binding bars along the height of steel tube is proposed. Five T-CFT stub columns with binding bars and another two without binding bars subjected to axial compression were tested. The influences of the spacing and diameter of binding bars on the failure modes, maximum strength, and ductility of T-CFT stub columns are investigated. The experimental results demonstrate that by setting binding bars or decreasing the spacing of binding bars, the buckling modes of the steel plates are changed, the local buckling of the steel plates is postponed, and the confinement effects on the core concrete can be improved significantly. By setting binding bars, the bearing capacity and ductility of the columns are enhanced by 1.17 and 3.38 times at most, respectively. By increasing the diameter of binding bars, the ductility of the columns is improved, but the bearing capacity and buckling strength cannot be improved when the diameter is large enough.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Yunyang Wang ◽  
Lei Xiao ◽  
Chu Jiang ◽  
Yandong Jia ◽  
Guang Yang ◽  
...  

This paper presents an experimental investigation on the mechanical behaviour of self-compacting concrete-filled thin-walled steel tubular (SCCFTST) stub columns loaded in axial compression to failure. Four specimens were tested to study the effect of diameter to wall thickness (D/t) ratios on the ultimate load, failure modes, and ductility of the columns. Confinement of the steel tube to concrete was also addressed. The failure modes, load versus displacement curves, and load versus strain curves were examined in detail. The experimental results showed that the ultimate state is reached when severe local buckling and rupture occurred on the steel tubes, and the concrete near the rupture has been crushed. The columns with larger D/t ratios appeared more local buckling, and its location is more close to the end of the columns. The SCCFTST stub columns with smaller D/t ratios show higher ultimate load and better ductility, and the steel tubes can exert higher confinement to the concrete.


1989 ◽  
Vol 26 (2) ◽  
pp. 97-102 ◽  
Author(s):  
A. D. Reddy ◽  
L. W. Rehfield ◽  
R. I. Bruttomesso ◽  
N. E. Krebs

2011 ◽  
Vol 94-96 ◽  
pp. 962-969
Author(s):  
Hai Chao Wang ◽  
Xi Quan Xu ◽  
Li Jun Zhou ◽  
Hong Ying Zhang ◽  
Feng Lian Yang

Based on the compression characteristics of the concrete-filled thin-walled square steel tube short columns, the U-shaped tie bars are designed in this paper. The U-shaped tie bars and steel pipe walls are connected with each other in T-shape in order to enhance the local stability of the walls under pressure. According to the concrete strength C30/C35/C40 and the thickness of the steel plates 1.25mm/1.75mm/2.5mm,42 short-column specimens are made, and the size of all specimens is 200mm×200mm×690mm.The bearing capacity test is done by the 500-ton electro-hydraulic serve testing machine. The strain of U-shaped tie bar and thin-walled steel are tested, and then the whole curve of compression process is obtained. The results show that the U-shaped tie bar has a very good role in bonding, and has good effects on improving buckling mode and the ductility of the components significantly. Concrete-filled thin-walled square steel tube short column fixed U-shaped tie bar has advantages on stronger post- deformability and more applicable to configuration compared with existing research achievements, and can provide a reference for engineering design.


Sign in / Sign up

Export Citation Format

Share Document