scholarly journals Study on Mitigation Method of Solder Corrosion for Crystalline Silicon Photovoltaic Modules

2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Ju-Hee Kim ◽  
Jongsung Park ◽  
Donghwan Kim ◽  
Nochang Park

The corrosion of 62Sn36Pb2Ag solder connections poses serious difficulties for outdoor-exposed photovoltaic (PV) modules, as connection degradation contributes to the increase in series resistance (RS) of PV modules. In this study, we investigated a corrosion mitigation method based on the corrosion mechanism. The effect of added sacrificial metal on the reliability of PV modules was evaluated using the oxidation-reduction (redox) reaction under damp heat (DH) conditions. Experimental results after exposure to DH show that the main reason for the decrease in power was a drop in the module’s fill factor. This drop was attributed to the increase ofRS. The drop in output power of the PV module without added sacrificial metal is greater than that of the sample with sacrificial metal. Electroluminescence and current-voltage mapping analysis also show that the PV module with sacrificial metal experienced less degradation than the sample without sacrificial metal.

Energies ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 303 ◽  
Author(s):  
Jeisson Vélez-Sánchez ◽  
Juan Bastidas-Rodríguez ◽  
Carlos Ramos-Paja ◽  
Daniel González Montoya ◽  
Luz Trejos-Grisales

Bypass diodes (BDs) present in photovoltaic (PV) modules are represented by the exponential model, which requires two parameters: the inverse-saturation current ( I s a t , d b ) and the ideality factor ( η d b ). However, it is difficult to estimate those parameters since the terminals of the BDs are not isolated, hence there is only access to the series connection of the module BDs. This problem must be addressed since inaccurate BDs parameters could produce errors in the reproduction of the current-voltage (I-V) curves of commercial PV modules, which lead to wrong predictions of the power production. This paper proposes a non-invasive procedure to estimate I s a t , d b and η d b of the bypass diodes present in a PV module using two experimental I-V curves. One I-V curve is measured completely covering the submodule of the module whose BD will be parameterized; while the other I-V curve is measured without any shadow on the module. From those curves, the I-V curve of the BD is estimated and I s a t , d b and η d b are calculated by solving a system of two nonlinear equations. The proposed procedure is validated through simulations and experimental results considering a commercial PV module formed by three submodules, where the estimation errors in the reproduction of the BD I-V curve are less than 1% in the simulations and less than 10% in the experiments.


Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2416 ◽  
Author(s):  
Woo Shin ◽  
Suk Ko ◽  
Hyung Song ◽  
Young Ju ◽  
Hye Hwang ◽  
...  

Bypass diodes have been widely utilized in crystalline silicon (c-Si) photovoltaic (PV) modules to maximize the output of a PV module array under partially shaded conditions. A Schottky diode is used as the bypass diode in c-Si PV modules due to its low operating voltage. In this work, we systematically investigated the origin of bypass diode faults in c-Si PV modules operated outdoors. The temperature of the inner junction box where the bypass diode is installed increases as the ambient temperature increases. Its temperature rises to over 70 °C on sunny days in summer. As the temperature of the junction box increases from 25 to 70 °C, the leakage current increases up to 35 times under a reverse voltage of 15 V. As a result of the high leakage current of the bypass diode at high temperature, melt down of the junction barrier between the metal and semiconductor has been observed in damaged diodes collected from abnormally functioning PV modules. Thus, it is believed that the constant leakage current applied to the junction caused the melting of the junction, thereby resulting in a failure of both the bypass diode and the c-Si PV module.


2013 ◽  
Vol 2013 ◽  
pp. 1-9 ◽  
Author(s):  
J. Webber ◽  
E. Riley

Variations in photovoltaic (PV) module current-voltage curves result in a power loss in PV arrays often referred to as mismatch loss (MML). As a means of reducing MML, newly fabricated PV modules are sorted to meet a set tolerance for variation in overall maximum power output with respect to a given module’s rated power. Starting with flash test data sets for two different polycrystalline PV modules and a simulated sorting procedure, Monte Carlo techniques were used to generate a large number of artificial PV arrays. The MMLs for each of these arrays were then calculated to assess the sorting procedure’s ability to reduce MML. Overall MMLs were quite small (0.001–0.01%). Sorting by Imp resulted in the most consistent MML reductions. Sorting by Vmp yielded insignificant results. Sorting by Pmp yielded significant MML reduction in only one of the two PV module data sets. Analysis was conducted to quantify if additional sorting on top of what both manufacturers had already done would make economic sense. Based on high level economic analysis, it appears that additional sorting yields little economic gain; however, this is highly dependent upon manufacturer sorting cost.


2021 ◽  
Vol 11 (23) ◽  
pp. 11257
Author(s):  
Jaesung Bae ◽  
Hongsub Jee ◽  
Yongseob Park ◽  
Jaehyeong Lee

Shingled photovoltaic (PV) modules with increased output have attracted growing interest compared to conventional PV modules. However, the area per unit solar cell of shingled PV modules is smaller because these modules are manufactured by dividing and bonding solar cells, which means that shingled PV modules can easily have inferior shading characteristics. Therefore, analysis of the extent to which the shadow affects the output loss is essential, and the circuit needs to be designed accordingly. In this study, the loss resulting from the shading of the shingled string used to manufacture the shingled module was analyzed using simulation. A divided cell was modeled using a double-diode model, and a shingled string was formed by connecting the cell in series. The shading pattern was simulated according to the shading ratio of the vertical and horizontal patterns, and in the case of the shingled string, greater losses occurred in the vertical direction than the horizontal direction. In addition, it was modularized and compared with a conventional PV module and a shingled PV module. The results confirmed that the shingled PV module delivered higher shading output than the conventional PV module in less shade, and the result of the shading characteristic simulation of the shingled PV module was confirmed to be accurate within an error of 1%.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2308
Author(s):  
Kamran Ali Khan Niazi ◽  
Yongheng Yang ◽  
Tamas Kerekes ◽  
Dezso Sera

Partial shading affects the energy harvested from photovoltaic (PV) modules, leading to a mismatch in PV systems and causing energy losses. For this purpose, differential power processing (DPP) converters are the emerging power electronic-based topologies used to address the mismatch issues. Normally, PV modules are connected in series and DPP converters are used to extract the power from these PV modules by only processing the fraction of power called mismatched power. In this work, a switched-capacitor-inductor (SCL)-based DPP converter is presented, which mitigates the non-ideal conditions in solar PV systems. A proposed SCL-based DPP technique utilizes a simple control strategy to extract the maximum power from the partially shaded PV modules by only processing a fraction of the power. Furthermore, an operational principle and loss analysis for the proposed converter is presented. The proposed topology is examined and compared with the traditional bypass diode technique through simulations and experimental tests. The efficiency of the proposed DPP is validated by the experiment and simulation. The results demonstrate the performance in terms of higher energy yield without bypassing the low-producing PV module by using a simple control. The results indicate that achieved efficiency is higher than 98% under severe mismatch (higher than 50%).


Author(s):  
Heangwoo Lee ◽  
Xiaolong Zhao ◽  
Janghoo Seo

Recent studies on light shelves found that building energy efficiency could be maximized by applying photovoltaic (PV) modules to light shelf reflectors. Although PV modules generate a substantial amount of heat and change the consumption of indoor heating and cooling energy, performance evaluations carried out thus far have not considered these factors. This study validated the effectiveness of PV module light shelves and determined optimal specifications while considering heating and cooling energy savings. A full-scale testbed was built to evaluate performance according to light shelf variables. The uniformity ratio was found to improve according to the light shelf angle value and decreased as the PV module installation area increased. It was determined that PV modules should be considered in the design of light shelves as their daylighting and concentration efficiency change according to their angles. PV modules installed on light shelves were also found to change the indoor cooling and heating environment; the degree of such change increased as the area of the PV module increased. Lastly, light shelf specifications for reducing building energy, including heating and cooling energy, were not found to apply to PV modules since PV modules on light shelf reflectors increase building energy consumption.


2017 ◽  
Vol 2017 ◽  
pp. 1-19 ◽  
Author(s):  
Vandana Jha ◽  
Uday Shankar Triar

This paper proposes an improved generalized method for evaluation of parameters, modeling, and simulation of photovoltaic modules. A new concept “Level of Improvement” has been proposed for evaluating unknown parameters of the nonlinear I-V equation of the single-diode model of PV module at any environmental condition, taking the manufacturer-specified data at Standard Test Conditions as inputs. The main contribution of the new concept is the improvement in the accuracy of values of evaluated parameters up to various levels and is based on mathematical equations of PV modules. The proposed evaluating method is implemented by MATLAB programming and, for demonstration, by using the values of parameters of the I-V equation obtained from programming results, a PV module model is build with MATLAB. The parameters evaluated by the proposed technique are validated with the datasheet values of six different commercially available PV modules (thin film, monocrystalline, and polycrystalline) at Standard Test Conditions and Nominal Operating Cell Temperature Conditions. The module output characteristics generated by the proposed method are validated with experimental data of FS-270 PV module. The effects of variation of ideality factor and resistances on output characteristics are also studied. The superiority of the proposed technique is proved.


Author(s):  
Mohamad Fakrie Mohamad Ali ◽  
◽  
Mohd Noor Abdullah ◽  

This paper presents the feasibility study of the technical and economic performances of grid-connected photovoltaic (PV) system for selected rooftops in Universiti Tun Hussein Onn Malaysia (UTHM). The analysis of the electricity consumption and electricity bill data of UTHM campus show that the monthly electricity usage in UTHM campus is very high and expensive. The main purpose of this project is to reduce the annual electricity consumption and electricity bill of UTHM with Net Energy Metering (NEM) scheme. Therefore, the grid-connected PV system has been proposed at Dewan Sultan Ibrahim (DSI), Tunku Tun Aminah Library (TTAL), Fakulti Kejuruteraan Awam dan Alam Bina (FKAAS) and F2 buildings UTHM by using three types of PV modules which are mono-crystalline silicon (Mono-Si), poly-crystalline silicon (Poly-Si) and Thin-film. These three PV modules were modeled, simulated and calculated using Helioscope software with the capacity of 2,166.40kWp, 2,046.20kWp and 1,845kWp respectively for the total rooftop area of 190,302.9 ft². The economic analysis was conducted on the chosen three installed PV modules using RETScreen software. As a result, the Mono-Si showed the best PV module that can produce 2,332,327.40 kWh of PV energy, 4.4% of CO₂ reduction, 9.3 years of payback period considering 21 years of the contractual period and profit of RM4,932,274.58 for 11.7 years after payback period. Moreover, the proposed installation of 2,166.40kWp (Mono-SI PV module) can reduce the annual electricity bill and CO2 emission of 3.6% (RM421,561.93) and 4.4% (1,851.40 tCO₂) compared to the system without PV system.


Author(s):  
Nsed Ayip Akonjom ◽  
John Iyang Umuji ◽  
Ukoette Jeremiah Ekah

This central idea of this research is to investigate how voltage, current, power output and efficiency of polycrystalline photovoltaic (PV) modules installed in a Guinea Savanna and Mangrove Swamp is affected by temperature, relative humidity and irradiance. The study locations are Calabar (mangrove swamp) and Ogoja (guinea savanna), in Cross River State, Nigeria. Two polycrystalline PV modules of exact specification mounted on a platform one-metre-high above the ground were used. A digital solar power meter (SM206) and a digital solar flux meter (MS 6616) was used to monitor and measure solar power and solar flux reaching the PV modules. A digital hygrometer and thermometer (KT-908) were used to monitor and measure the relative humidity and ambient temperature level at the height of installation and a digital multimeter (M880C+) accompanied with a temperature sensor was used to monitor voltage, current and panel temperature values from the modules. Analysis of the collected data reveals that the efficiency of the modules were not constant throughout the day. However, a higher voltage production and efficiency level was obtained for the PV module installed in Ogoja than that installed in Calabar under their respective levels of relative humidity, temperature and irradiance.


2019 ◽  
Vol 9 ◽  
pp. 59-69
Author(s):  
Alok Dhaundiyal ◽  
Divine Atsu

This paper presents the modeling and simulation of the characteristics and electrical performance of photovoltaic (PV) solar modules. Genetic coding is applied to obtain the optimized values of parameters within the constraint limit using the software MATLAB. A single diode model is proposed, considering the series and shunt resistances, to study the impact of solar irradiance and temperature on the power-voltage (P-V) and current-voltage (I-V) characteristics and predict the output of solar PV modules. The validation of the model under the standard test conditions (STC) and different values of temperature and insolation is performed, as well as an evaluation using experimentally obtained data from outdoor operating PV modules. The obtained results are also subjected to comply with the manufacturer’s data to ensure that the proposed model does not violate the prescribed tolerance range. The range of variation in current and voltage lies in the domain of 8.21 – 8.5 A and 22 – 23 V, respectively; while the predicted solutions for current and voltage vary from 8.28 – 8.68 A and 23.79 – 24.44 V, respectively. The measured experimental power of the PV module estimated to be 148 – 152 W is predicted from the mathematical model and the obtained values of simulated solution are in the domain of 149 – 157 W. The proposed scheme was found to be very effective at determining the influence of input factors on the modules, which is difficult to determine through experimental means.


Sign in / Sign up

Export Citation Format

Share Document