scholarly journals Spectrogram Analysis of Complete Dentures with Different Thickness and Palatal Rugae Materials on Speech Production

2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Hamada Zaki Mahross ◽  
Kusai Baroudi

Objective. To investigate the influence of reproduction of different thickness and palatal rugae materials on complete dentures speech using Computerized Speech Lab (CSL) (spectrogram).Materials and Methods. Three completely edentulous male patients (aged 50–60 years) were selected for reading a paragraph. Twelve upper dentures were constructed, four for each patient. The patients’ speech groups were divided into five groups, Group I: patients without dentures; Group II: patients rehabilitated with conventional acrylic dentures; Group III: patients with conventional acrylic dentures with rugae reproduction; Group IV: patients with dentures with metallic framework of minimal thickness and direct ragged metallic palatal surface at rugae area; Group V: patients with dentures with palatal rugae constructed from resilient acrylic resin material with thickness less than conventional denture. Speech samples were recorded after insertion of each denture for groups using Computerized Speech Lab (CSL) (spectrogram). The sounds selected were lingopalatal /s/z/sh/t/d/ and /l/.Results. Group III produced high mean significant difference with /sh/t/ sound. For Group IV, the difference was noticed with /s/z/sh/t/ and /d/ sounds, while for Group V the difference was shown with /z/l/ sound (P<0.05).Conclusion. It is recommended to reproduce the rugae area in complete denture because the phonetic quality of complete denture with rugae is superior to the conventional denture.

2017 ◽  
Vol 1 (1) ◽  
pp. 20-25
Author(s):  
Pooja Kabra

ABSTRACT Aim The purpose of this study was to evaluate the fracture strength of roots instrumented with the self-adjusting file (SAF; ReDent-Nova, Ra'anana, Israel) and the Reciproc reciprocating file and that were and were not obturated using the warm vertical lateral compaction technique. Materials and methods In total, 75 mandibular premolar teeth were sectioned at or below the cementoenamel junction to obtain roots 13 mm in length. The roots were balanced with respect to buccolingual and mesiodistal diameters and weight. They were distributed into four experimental groups and one control group (n = 15): No instrumentation (group I), instrumentation with SAF files but no obturation (group II), instrumentation with SAF files and obturated with warm vertical lateral compaction (group III), instrumentation with Reciproc File but no obturation (group IV), and instrumentation with Reciproc File and obturated with warm vertical lateral compaction (group V). AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) was used along with gutta-percha points. One week later, a vertical load was applied to the specimen's canal until fracture occurred. Data were statistically analyzed using one-way analysis of variance (p = 0.05). Results The mean fracture load was 312.83 N for group I, 297.35 N for group II, 359.15 N for group III, 231.51 N for group IV, and 275.81 N for group V. Conclusion The fracture resistances exhibited a statistically significant difference between all the groups. Teeth instrumented by SAF exhibited a better fracture resistance. How to cite this article Tyagi S, Choudhary E, Kabra P, Chauhan R. An in vitro comparative Evaluation of Fracture Strength of Roots Instrumentated with Self-adjusting File and Reciproc Reciprocating File, with and without Obturation. Int J Clin Dent Res 2017;1(1):20-25.


2015 ◽  
Vol 09 (02) ◽  
pp. 224-227 ◽  
Author(s):  
Shenbagakuttalam Anand ◽  
Ambrose Vedamanickam Rajesh Ebenezar ◽  
Nirupa Anand ◽  
Kothandaraman Rajkumar ◽  
Sekar Mahalaxmi ◽  
...  

ABSTRACT Objectives: To comparatively assess the micro shear bond strength (MSBS) of dentin bonded surface pre-treated zirconia ceramics. Materials and Methods: Zirconia blocks were sectioned into 50 cubical blocks. The blocks were further categorized into five groups (n = 10 each). Group I: No treatment was performed on zirconia samples; Group II: The zirconia samples were sand-blasted; Group III: Group II + etched with 9.8% of hydrofluoric (HF) acid for 60 s; Group IV: The sandblasted zirconia samples were selectively infiltrated with low fusing porcelain; and Group V: Group IV + etched using 9.8% HF acid gel. The zirconia specimens were then bonded to dentin samples, and the samples were tested for MSBS evaluation using universal testing machine. Results: The MSBS of all the four experimental groups shows greater value than group I. Among the experimental groups, group V and group IV do not show any statistical significant difference, whereas the mean MSBS of groups IV and V were statistically greater than group III and group II. However, groups I, II, and III do not show any statistical significant difference in mean MSBS values between them. Conclusion: Selective infiltration etching of zirconia ceramics provides the highest bond strength with resin cement.


2010 ◽  
Vol 04 (03) ◽  
pp. 257-262 ◽  
Author(s):  
Oral Sokucu ◽  
Seyda Herguner Siso ◽  
Firat Ozturk ◽  
Ruhi Nalcaci

Objectives: The aim of this study was to compare the shear bond strength (SBS) of two different light sources under different thermal cycle frequencies.Methods: Ninety human premolar teeth were divided into six groups, in which three groups consisted of halogen groups – Group I was cured with halogen without thermocycle, Group II cured with halogen with 500 thermocycles, and Group III cured with halogen with 10,000 thermocycles. The other three groups consisted of Plasma arc (PAC) group – Group IV was cured with PAC without thermocycle, Group V cured with PAC thermocycled 500 cycles, and Group VI cured with PAC thermocycled 10,000 cycles. Two way ANOVA was used to compare the SBS between the groups, and chi squaretest was used to compare the bond failure of ARI scores among the groups.Results: A significant difference was found for curing lights (P<.001) and thermocycling (P<.01). However, there was no interaction between light curing and thermocycling (P=.177). The halogen groups demonstrated higher mean SBS than the PAC groups. Both groups showed a significant reduction between no cycles and 10,000 cycles (P<.05).Conclusions: Both light sources showed favorable SBS performance without the thermocycle procedure. Thermocycling significantly decreased the SBS values of both groups. (Eur J Dent 2010;4:257- 262)


2015 ◽  
Vol 1 (2) ◽  
pp. 72
Author(s):  
Wahdah Norsiah

Examination of hemoglobin levels influenced leukocytosis sianmethemoglobin method that causes increased absorbance measurements of hemoglobin levels increased significantly and the false blood sample that has been diluted with a solution Drabkins in centrifugation at 3000 rpm for 10 minutes and then the absorbance of the supernatant was measured with a photometer at λ 546 nm. This study aimed to analyze the differences in hemoglobin level examination siamethemoglobin method with and without centrifugation at sample leukocytosis. This type of research is observational research laboratory. The study design was cross-sectional study. Samples were taken from the remaining blood samples of patients who have been examined leukositnya number more than 20,000 / uL with Hematology Analyzer (CEL-DYN Ruby) February-April 2014, and were divided into 4 groups based on criteria that group 1. leukocyte count of 20,000 / uL-29 999 / mL, group II. 30,000 / uL-39 999 / uL, the group III. 40,000 / uL-49,999 / uL, the group IV. More than 50,000 / uL. The number of samples taken were 20 samples of each group, a total sample of 80 samples. The analysis showed no significant difference in hemoglobin levels siamethemoglobin method with and without centrifugation at sample leukocytosis with a value of p = 0.000 less than 0.05 α. Leukocytosis Turbidity affects the difference in hemoglobin levels with and without centrifugation, the higher the number the greater the difference in leukocyte levels of hemoglobin, hemoglobin level examination results of the study based on the criteria of the number of leukocytes obtained by the difference in hemoglobin levels with and without centrifugation in group I. 0.22 ± 0.07 g / dL, group II 0.40 ± 0.22 g / dL, a group III. 0.44 ± 0.14 g / dL, Group IV. 0.85 ± 0.41 g / dL. The level of hemoglobin in the sample sianmethemoglobin method leukocytosis with more than 20,000 / uL need a centrifuge so that appropriate hemoglobin levels over the patient's clinical condition.


2021 ◽  
Vol 9 (1) ◽  
pp. 5-9
Author(s):  
Samarla Aruna Kumari ◽  
Averneni Prema Latha Prema Latha ◽  
Naveen Reddy ◽  
Rohit Sharma ◽  
Mahesh Melkundi ◽  
...  

Aim: Capability of lithium disilicate glass ceramics to reproduce the A2 shade and to mask A4 substrates.Materials and Method: 32 lithium disilicate ceramic specimens were classified materials into 8 groupsof 4 each. Group I- III high translucency (HT) monolayer discs, group IV- VI had low translucency (LT)monolayer discs, group VII- VIII had medium translucency (MO) bilayer discs. A2 shade tab shade guide(VITA classical A1-D4) was used for CIE L*a*b* measurements of control. Color differences using thresholdswas as follows: for imperceptible (?E < 1.0), perceptible (1.0 < ?E < 3.3), and clinically unacceptable (?E> 3.3) differences.Results: ?E in group IV exhibited highest (9.92±0.21) and group III lowest (8.08± 0.25) value. When thecomplex was compared to the A4 substrate, significant difference among all groups (p < 0.05) was found.?E values when the complex was compared to the A2 shade tab, group III exhibited highest (4.82±0.16)and group V lowest (0.72±0.06) value. In groups I specimens had acceptable differences, group II hadperceptible differences, group III had perceptible differences, group IV had acceptable differences, group Vhad imperceptible differences, group VI and VII had acceptable differences and group VIII had imperceptibledifferences.Conclusion: Authors suggested to use LT ceramics with less thickness in the range of 0.5 mm- 0.7 mm tomask discoloration.


2017 ◽  
Vol 2 (01) ◽  
pp. 43-46
Author(s):  
Dinesh Mahto

A total of 50 cross bred repeat breeder cattle were selected and grouped into 4 treatment and one control group which belonging to organized farms around, K. V. K. Gandhar, Jehanabad. Hydroxyprogesterone caproate (500 mg) was administered I.M. on day 4 post A. I. in group I, In group II, 500mg progesterone was administered I M on day 4 and again on day 10. Evatocin (40 I.U.) was administered I.M. 5 minutes before A.I. to animals belonging to group III. The same drug was used through Intra vulvo-submucosal route (15 I.U.) to animals of group IV. Group V animals received no treatment and served as control. Pregnancy diagnosis was done by rectal palpation D 45-60 after artificial insemination. In group I, the conception rate was found to be 60% as against 20 % in the control (Non-significant), Gr II, the conception rate improved from 20% in control animals to 70% in treated animals (Significant) and Gr III, the C.R. 60% than control(20%) where as Gr IV, C.R. 40% . The difference in conception rate of treatment and control group animals was non-significant.


2021 ◽  
pp. 39-45
Author(s):  
Nura I. Al-Zail ◽  
Salah F. Kamies

Pyrethroid cyhalothrin (PC) is an insecticide that is used worldwide for pest control in agriculture and household use. Samoa extract (SE) is a potent antioxidant protecting cells from oxidative stress. The present study investigates the protective and therapeutic effect of SE on PC-induced changes in sperm quality in male rats. Fifty adult male albino rats were divided into five groups: group I: served as control; group II: received PC i.p. only (6.2 mg/kg b.wt.); group III: received SE only (100 mg/kg b.wt., p.o.) for eight weeks; group IV: received SE as a protective agent daily for eight weeks, then followed by the administration of PC (i.p.) three times a week for two weeks; group V: exposed to PC (i.p.) three times a week for two weeks, then treated with the SE daily for 8 weeks. Results showed that PC caused markedly impaired sperm quality (a count, viability, motility, and abnormality). Compared to PC-treated animals, SE in the protective group markedly restored the alteration of sperm indices. However, SE in the curative group was found to be less effective in restoring PC-induced alterations. In conclusion, the data of this study revealed that the SE as a protective agent is more effective than as a therapeutic agent. Keywords: Samoa; Pyrethroid; Sperm quality; Rat


1994 ◽  
Vol 267 (5) ◽  
pp. F703-F708 ◽  
Author(s):  
M. Giordano ◽  
P. Castellino ◽  
E. L. McConnell ◽  
R. A. DeFronzo

We evaluated the dose-response relationship between the plasma amino acid (AA) concentration and renal hemodynamics in eight normal subjects. After an overnight fast, a balanced 10% AA solution was infused for 180 min at five separate infusion rates: 0.5 (group I), 1.0 (group II), 2.0 (group III), 4.0 (group IV), and 6.0 (group V) ml.kg-1.min-1 on separate days. Basal plasma AA concentration was 1.87 +/- 0.1 mmol/l and increased to 2.26 +/- 0.1 (group I), 2.66 +/- 0.2 (group II), 3.79 +/- 0.5 (group III), 5.81 +/- 0.4 (group IV), and 7.41 +/- 0.4 mmol/l (group V). Basal glomerular filtration rate (GFR) and renal plasma flow (RPF) averaged 95 +/- 4 and 476 +/- 29 ml.1.73 m-2.min-1, respectively, and rose to 98 +/- 5 and 506 +/- 40 (group I) [P = not significant (NS)], 102 +/- 3 and 533 +/- 30 (group II) (P < 0.05 vs. basal), 110 +/- 4 and 567 +/- 29 (group III), 115 +/- 7 and 610 +/- 55 (group IV), and 117 +/- 7 and 614 +/- 66 ml.1.73 m-2.min-1 (group V) (P = NS vs. group IV). Basal plasma glucagon concentration averaged 68 +/- 10 pg/ml and increased to 74 +/- 10 (group I), 83 +/- 11 (group II) (P < 0.05 vs. basal), 100 +/- 14 (group III), 121 +/- 14 (group IV), and 229 +/- 35 pg/ml (group V) (P < 0.01 vs. basal). Increases in plasma growth hormone (GH) and insulin levels were observed only during groups IV and V.(ABSTRACT TRUNCATED AT 250 WORDS)


2020 ◽  
Vol 5 (1) ◽  
pp. 153-155
Author(s):  
Sanjay Melville Masih ◽  
Rakesh Kumar Gupta

Background: The present study was conducted to assess the outcome of intrathecal analgesia in multiparous women undergoing vaginal delivery. Subjects and Methods: The present study was conducted among 80 multiparous women ages ranged 18- 40 years. All patients received 0.5 ml of intrathecal injection of 2.5 mg bupivacaine 0.5% and 1 ml dexamethasone 4 mg plus a 0.5 ml adjuvant. The adjuvants in group I patients were 100 μg morphine, 25 μg fentanyl in group II, 5 μg dexmedetomidine in group III and normal saline in group IV (control group). The primary and secondary outcome was the duration of pain relief, the analgesia onset time, the maximum level of sensory block, the visual analogue scale (VAS) was recorded. Results: The mean duration of analgesia in group I was 182.4 minutes, in group II was 170.5 minutes, in group III was 200.4 minutes and in group, IV was 140.2 minutes. The onset of analgesia was 3.9 minutes, 2.8 minutes, 2.7 minutes and 4.5 minutes in group I, II, III and IV respectively. S1 sensory regression time (minutes) was 181.4, 157.4, 185.3 and 130.6 in group I, II, III and IV respectively. Modified Bromage scale 5 minutes, 15 minutes and 30 minutes after IT in all groups was 0.0. VAS was 1.3, 1.6, 1.6 and 3.1 with significant differences in all groups (P< 0.05). There was non- significant difference in mean age, weight, height and gestational age between all groups (P> 0.05). There was a non- significant difference in APGAR 1, 5, umbilical pH immediately after delivery, neonatal HR after 5minute, 15 minutes and 30 minutes in all groups (P> 0.05). Conclusion: The authors found that dexmedetomidine is a safe and effective adjuvant to intrathecal bupivacaine-dexamethasone in multiparous women undergoing normal vaginal delivery.


2013 ◽  
Vol 14 (1) ◽  
pp. 56-60 ◽  
Author(s):  
S Nagalaxmi Reddy ◽  
DN Jayashankar ◽  
Mohanthomas Nainan

ABSTRACT Aim Aim of this study was to compare class II composite restoration using flowable composites as lining with various thickness and curing techniques by evaluating cervical marginal microleakage. Materials and methods Fifty intact molars, each prepared with two box-only class II cavities, were randomly divided into five groups: Group I, P60 filling alone; group II, ultrathin flowable composite lining (0.5-1mm) cocured with overlying composite; group III, thin lining (1-1.5) cocured with overlying composite; group IV, ultrathin lining (0.5-1 mm) precured and group V, thin lining (1-1.5) precured. The teeth were then thermocycled for 1500 cycles (between 5 and 60 °C) and immersed in dye for 24 hours. Cervical microleakage was measured as the extent of dye penetration. Results Cocured specimens (groups II and III) showed least microleakage and control specimens (group I) showed maximum microleakage. On comparison of curing techniques, cocured specimens (groups II and III) showed less microleakage than precured (groups IV and V). On comparison of lining thickness and type of curing, group IV showed less microleakage than group V. Groups II and III were statistically not significant. Conclusion It was concluded from the results that ultrathin cocured flowable composite lining specimens improved the marginal sealing with decreased microleakage. Clinical significance In this study, the application of additional flowable composite lining with various thicknesses presented different influences in marginal quality of class II box only composite restorations. A new technique applying an ultrathin flowable composite lining with cocuring technique improved the marginal sealing with decreased microleakage. Restorations with thin lining presented reduced marginal integrity after thermocycling. How to cite this article Reddy SN, Jayashankar DN, Nainan M, Shivanna V. The Effect of Flowable Composite Lining Thickness with Various Curing Techniques on Microleakage in Class II Composite Restorations: An in vitro Study. J Contemp Dent Pract 2013;14(1):56-60.


Sign in / Sign up

Export Citation Format

Share Document