scholarly journals Numerical Analysis of the Seismic Response of Tunnel Composite Lining Structures across an Active Fault

2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
Zude Ding ◽  
Mingrong Liao ◽  
Nanrun Xiao ◽  
Xiaoqin Li

The mechanical properties of high-toughness engineering cementitious composites (ECC) were tested, and a damage constitutive model of the materials was constructed. A new aseismic composite structure was then built on the basis of this model by combining aseismic joints, damping layers, traditional reinforced concrete linings, and ECC linings. A series of 3D dynamic-response numerical models considering the composite structure-surrounding rock-fault interaction were established to explore the seismic response characteristics and aseismic performance of the composite structures. The adaptability of the structures to the seismic intensity and direction was also discussed. Results showed that the ECC material displays excellent tensile and compressive toughness, with respective peak tensile and compressive strains of approximately 300- and 3-fold greater than those of ordinary concrete at the same strength grade. The seismic response law of the new composite lining structure was similar to that of the conventional composite structure. The lining in the fault zone and adjacent area showed obvious acceleration amplification responses, and the stress and displacement responses were fairly large. The lining in the fault zone was the weak part of the composite structures. Compared with the conventional aseismic composite structure, the new composite lining structure effectively reduced the acceleration amplification and displacement responses in the fault area. The damage degree of the new composite structure was notably reduced and the damage area was smaller compared with those of the conventional composite structure; these findings demonstrate that the former shows better aseismic effects than the latter. The intensity and direction of seismic waves influenced the damage of the composite structures to some extent, and the applicability of the new composite structure to lateral seismic waves is significantly better than that to axial waves. More importantly, under the action of different seismic intensities and directions, the damage degree and distribution area of the new composite structure were significantly smaller than those of the conventional composite lining structure.

2020 ◽  
Vol 92 (6) ◽  
pp. 59-65
Author(s):  
G.P. TONKIH ◽  
◽  
D.A. CHESNOKOV ◽  
◽  

Most of Russian research about composite structure fire resistance are dedicated to the composite slab behavior. The composite beams fire resistance had been never investigated in enough volume: the temperature evaluation within the scope of the actual Russian design codes leads to the significant reduction in the shear connection strength. Meanwhile, there no correlation between the strength decreasing and type of the shear connection. The article provides an overview of the relevant researches and offers some approaches which could take into account bearing capacity reduction of the shear connectors within composite structures design.


Materials ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1685
Author(s):  
Hang Zhang ◽  
Zihao Chen ◽  
Yaoyao He ◽  
Xin Guo ◽  
Qingyu Li ◽  
...  

The conventional method of preparing metal–ceramic composite structures causes delamination and cracking defects due to differences in the composite structures’ properties, such as the coefficient of thermal expansion between metal and ceramic materials. Laser-directed energy deposition (LDED) technology has a unique advantage in that the composition of the materials can be changed during the forming process. This technique can overcome existing problems by forming composite structures. In this study, a multilayer composite structure was prepared using LDED technology, and different materials were deposited with their own appropriate process parameters. A layer of Al2O3 ceramic was deposited first, and then three layers of a NbMoTa multi-principal element alloy (MPEA) were deposited as a single composite structural unit. A specimen of the NbMoTa–Al2O3 multilayer composite structure, composed of multiple composite structural units, was formed on the upper surface of a φ20 mm × 60 mm cylinder. The wear resistance was improved by 55% compared to the NbMoTa. The resistivity was 1.55 × 10−5 Ω × m in the parallel forming direction and 1.29 × 10−7 Ω × m in the vertical forming direction. A new, electrically anisotropic material was successfully obtained, and this study provides experimental methods and data for the preparation of smart materials and new sensors.


2021 ◽  
Author(s):  
Tan Li ◽  
Guangbo Chen ◽  
Zhongcheng Qin ◽  
Qinghai Li

Abstract The stability of coal-rock composite structures is of great significance to coal mine safety production. To study the stability and deformation failure characteristics of the coal-rock composite structure, the uniaxial cyclic loading tests of the coal-rock composite structures with different coal-rock height ratios were carried out. Lithology and coal-rock height ratio play an important role in the energy dissipation of coal-rock composite structures. The higher the coal-rock height ratio, the greater the average elastic energy and dissipated energy produced per cycle of coal-rock composite structures, the smaller the total elastic energy and dissipated energy produced in the process of cyclic loading. Based on the difference of damage variables calculated by dissipative energy method and acoustic emission method, a more sensitive joint calculation method for calculating damage variable was proposed. The joint damage variable calculation method can more accurately and sensitively reflect the damage of coal-rock composite structure under cyclic loading. The macroscopic crack first appears in the coal specimen in the coal-rock composite structure, the degree of broken coal specimens in the composite structure is inversely proportional to the coal-rock height ratio. The strength and deformation characteristics of the coal-rock composite structure are mainly affected by coal sample in the composite structure.


2018 ◽  
Vol 2018 ◽  
pp. 1-11
Author(s):  
Chen Xia ◽  
Chengzhi Qi ◽  
Xiaozhao Li

Transmitting boundaries are important for modeling the wave propagation in the finite element analysis of dynamic foundation problems. In this study, viscoelastic boundaries for multiple seismic waves or excitations sources were derived for two-dimensional and three-dimensional conditions in the time domain, which were proved to be solid by finite element models. Then, the method for equivalent forces’ input of seismic waves was also described when the proposed artificial boundaries were applied. Comparisons between numerical calculations and analytical results validate this seismic excitation input method. The seismic response of subway station under different seismic loads input methods indicates that asymmetric input seismic loads would cause different deformations from the symmetric input seismic loads, and whether it would increase or decrease the seismic response depends on the parameters of the specific structure and surrounding soil.


2020 ◽  
Vol 10 (4) ◽  
pp. 375-386 ◽  
Author(s):  
Jiankai Zhu ◽  
Xiangxian Wang ◽  
Yuan Wu ◽  
Yingwen Su ◽  
Tianxu Jia ◽  
...  

Abstract In this paper, we propose two kinds of composite structures based on the one- and two-dimensional (1D&2D) gold grating on a gold film for plasmonic refractive index sensing. The resonance modes and sensing characteristics of the composite structures are numerically simulated by the finite-difference time-domain method. The composite structure of the 1D gold semi-cylinder grating and gold film is analyzed first, and the optimized parameters of the grating period are obtained. The sensitivity and figure of merit (FOM) can reach 660RIU/nm and 169RIU−1, respectively. Then, we replace the 1D grating with the 2D gold semi-sphere particles array and find that the 2D grating composite structure can excite strong surface plasmon resonance intensity in a wider period range. The sensitivity and FOM of the improved composite structure can reach 985RIU/nm and 298 RIU−1, respectively. At last, the comparison results of the sensing performance of the two structures are discussed. The proposed structures can be used for bio-chemical refractive index sensing.


Author(s):  
Ankit Kumar

Abstract: This study examines the composite structure that is increasing commonly in developing countries. For medium-rise to high-rise building construction, RCC structures is no longer economical due to heavy dead weight, limited span, low natural frequency and hazardous formwork. The majority of commercial buildings are designed and constructed with reinforced concrete, which largely depends on the existence of the constituent materials as well as the quality of the necessary construction skills, and including the usefulness of design standards. Conventional RCC structure is not preferred nowadays for high rise structure. However, composite construction, is a recent development in the construction industry. Concrete-steel composite structures are now very popular due to some outstanding advantages over conventional concrete and steel structures. In the present work, RCC and steel-concrete composite structure are being considered for a Dynamic analysis of a G+25-storey commercial building of uniform and optimized section, located at in seismic zone IV. Response Spectrum analysis method is used to analyze RCC and composite structure, CSI ETABS v19 software is used and various results are compared such as time period, maximum storey displacement, maximum storey stiffness. Maximum storey shear and maximum stoey overturning moment. Keywords: RCC Structure, Composite Structure, Uniform Section, Optimized Section, Shear Connector, Time Period, Storey Displacement, Storey Shear, Storey Stiffness, Response Spectrum method, ETABS


Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 499
Author(s):  
Olaf Dudek ◽  
Wojciech Klein ◽  
Damian Gąsiorek ◽  
Mariusz Pawlak

3D printing of a composite structure with shape memory materials requires a special approach to the subject, at the stage of the design and printing process. This paper presents the design steps during the development of a 3D-printed composite structure with shape memory material. The connection points between the SMA fibers and the printer filament are developed in the MATLAB environment. Finite element method is used to simulate the shortening of the shape memory material under the influence of temperature and its effect on the printed polymer material is presented. In the MATLAB environment, evolutionary algorithms were used to determine the shape of the SMA fiber alignment. This work demonstrates the use of shape memory effect in 3D printed smart composite structures, where the component takes a predetermined shape. The structure obtained as a result of such printing changes with the heat generated by the current voltage, making it the desired fourth dimension.


2021 ◽  
pp. 875529302110513
Author(s):  
Eleftheria Efthymiou ◽  
Alfredo Camara

The definition of the spatial variability of the ground motion (SVGM) is a complex and multi-parametric problem. Its effect on the seismic response of cable-stayed bridges is important, yet not entirely understood to date. This work examines the effect of the SVGM on the seismic response of cable-stayed bridges by means of the time delay of the ground motion at different supports, the loss of coherency of the seismic waves, and the incidence angle of the seismic waves. The focus herein is the effect of the SVGM on cable-stayed bridges with various configurations in terms of their length and of design parameters such as the pylon shape and the pylon–cable system configuration. The aim of this article is to provide general conclusions that are applicable to a wide range of canonical cable-stayed bridges and to contribute to the ongoing effort to interpret and predict the effect of the SVGM in long structures. This work shows that the effect of the SVGM on the seismic response of cable-stayed bridges varies depending on the pylon shape, height, and section dimensions; on the cable-system configuration; and on the response quantity of interest. Furthermore, the earthquake incidence angle defines whether the SVGM is important to the seismic response of the cable-stayed bridges. It is also confirmed that the SVGM excites vibration modes of the bridges that do not contribute to their seismic response when identical support motion is considered.


2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Guoqing Liu ◽  
Yanhong Zhang ◽  
Ming Xiao

In order to explore the influence of internal water on the seismic response of hydraulic tunnel, the combined mechanical analysis models of multimaterial including surrounding rock, lining structure, and internal water are built. Based on the explicit central difference method, the dynamic finite element analysis methods for rock, lining, and water are discussed, respectively. The dynamic contact force method is used to simulate the rock-lining contact interaction, and the arbitrary Lagrange-Euler (ALE) method is used to simulate the lining-water coupling interaction. Then a numerical simulation analysis method for combined seismic response of rock-lining-water system in hydraulic tunnel is proposed, and the detailed solving steps are given. This method is used to study the seismic stability characteristics of the water diversion tunnel in a hydropower station, and the displacement, stress, and damage failure characteristics of the lining structure under the conditions of no water, static water, and dynamic water are comparatively analyzed. The results show that the hydrostatic pressure restricts the seismic response of the lining, while the hydrodynamic pressure exacerbates its seismic response and leads to damage, separation, and slip failure appearing on the haunch, which can provide a scientific reference for the seismic design of hydraulic tunnel with high water head and large diameter.


Sign in / Sign up

Export Citation Format

Share Document