Angio-CT

1995 ◽  
Vol 1 (1) ◽  
pp. 43-57 ◽  
Author(s):  
G. Grossi ◽  
F. Romanzi ◽  
G. MacChia ◽  
U. Ruffinengo ◽  
S. Calia

After nine months' experience with helical CT (Elscint Twin), we describe an epicrisis in 13 patients with intracranial aneurysms, 12 of whom were referred to us by the emergency room for suspect subarachnoid hemorrhage. After standard CT scan confirming subarachnoid hemorrhage, patients underwent angio-CT with display of the sac responsible for bleeding in all cases. All patients subsequently underwent digital angiography which confirmed the angio-CT findings and in three cases disclosed associated malformations. The sensitivity, specificity and diagnostic accuracy of the technique are assessed in relation to the quality of the images obtained (MIP) in such a short time (15 min on average). The diagnostic information is comparable to that offered by angio-MR with the obvious positive and negative aspects linked to each method. Digital angiography remains the technique of choice in terms of diagnostic accuracy, but carries some risk to the patient.

2020 ◽  
Vol 93 (1109) ◽  
pp. 20190847 ◽  
Author(s):  
Pankaj Gupta ◽  
Varun Bansal ◽  
Praveen Kumar-M ◽  
Saroj K Sinha ◽  
Jayanta Samanta ◽  
...  

Objective: To evaluate the sensitivity, specificity, and diagnostic odds ratio (DOR) of Doppler ultrasound, CT, and MRI in the diagnosis of Budd Chiari syndrome (BCS). Methods: We performed a literature search in PubMed, Embase, and Scopus to identify articles reporting the diagnostic accuracy of Doppler ultrasound, CT, and MRI (either alone or in combination) for BCS using catheter venography or surgery as the reference standard. The quality of the included articles was assessed by using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Results: 11 studies were found eligible for inclusion. Pooled sensitivities and specificities of Doppler ultrasound were 89% [95% confidence interval (CI), 81–94%, I2 = 24.7%] and 68% (95% CI, 3–99%, I2 = 95.2%), respectively. Regarding CT, the pooled sensitivities and specificities were 89% (95% CI, 77–95%, I2 = 78.6%) and 72% (95% CI, 21–96%, I2 = 91.4%), respectively. The pooled sensitivities and specificities of MRI were 93% (95% CI, 89–96%, I2 = 10.6%) and 55% (95% CI, 5–96%, I2 = 87.6%), respectively. The pooled DOR for Doppler ultrasound, CT, and MRI were 10.19 (95% CI: 1.5, 69.2), 14.57 (95% CI: 1.13, 187.37), and 20.42 (95% CI: 1.78, 234.65), respectively. The higher DOR of MRI than that of Doppler ultrasound and CT shows the better discriminatory power. The area under the curve for MRI was 90.8% compared with 88.4% for CT and 86.6% for Doppler ultrasound. Conclusion: Doppler ultrasound, CT and MRI had high overall diagnostic accuracy for diagnosis of BCS, but substantial heterogeneity was found. Prospective studies are needed to investigate diagnostic performance of these imaging modalities. Advances in knowledge: MRI and CT have the highest meta-analytic sensitivity and specificity, respectively for the diagnosis of BCS. Also, MRI has the highest area under curve for the diagnosis of BCS.


2020 ◽  
Vol 40 (3) ◽  
Author(s):  
Qingqing Lu ◽  
Jie Li ◽  
Hui Cao ◽  
Chenlu Lv ◽  
Xiaolin Wang ◽  
...  

Abstract Objective: Midkine (MDK) has been proposed as one of the most promising markers for hepatocellular carcinoma (HCC). This meta-analysis was conducted to compare the diagnostic accuracy of MDK and α-fetoprotein (AFP) for HCC. Methods: We systematically searched PubMed/MEDLINE, Ovid/EMBASE, and the Cochrane Library for all relevant studies up to 18 May 2019. The Revised Quality Assessment for Studies of Diagnostic Accuracy tool (QUADAS-2) was used to assess the methodological quality of the included studies. The sensitivity, specificity, and the area under the curve (AUC) of MDK and AFP for detecting HCC were pooled using random-effects model. Results: Seventeen studies from five articles with a total of 1122 HCC patients and 2483 controls were included. The summary estimates using MDK and AFP for detecting HCC were as follows: sensitivity, 85 vs 52%, specificity, 82 vs 94%, and AUC, 0.90 vs 0.83. The summary estimates using MDK and AFP for detecting hepatitis virus-related HCC as follows: sensitivity, 93 vs 74%, specificity, 85 vs 97%, and AUC, 0.95 vs 0.97. The summary estimates using MDK and AFP for detecting early-stage HCC were as follows: sensitivity, 83.5 vs 44.4%, specificity, 81.7 vs 84.8%, and AUC, 0.87 vs 0.52. The summary estimates using MDK for detecting AFP-negative HCC as follows: sensitivity, 88.5%, specificity, 83.9%, and AUC, 0.91. Conclusion: MDK is more accurate than AFP in diagnosing HCC, especially for early-stage HCC and AFP-negative HCC. Both MDK and AFP had excellent diagnostic performance for hepatitis virus-related HCC.


2015 ◽  
Vol 129 (7) ◽  
pp. 682-687
Author(s):  
P V Kaye ◽  
M Pigera ◽  
M M Khan ◽  
P Hollows ◽  
N Beasley

AbstractObjective:This study aimed to examine the performance of head and neck cytology at Nottingham University Hospitals between 2009 and 2010.Methods:Cases were extracted from the Winpath pathology reporting system and correlations were investigated between results and the histological and clinical outcomes. Specimen adequacy and the sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of the cytology tests were calculated.Results:In all, 19.7 per cent of aspirates were judged to be inadequate. The absolute and relative sensitivities of head and neck cytology were 87.0 per cent and 89.0 per cent, respectively, and the absolute and relative specificities were 99.0 per cent and 97.0 per cent, respectively. The positive predictive values were 99.0 per cent and 96.0 per cent and the negative predictive values were 92.0 per cent and 92.0 per cent for a diagnostic accuracy of 94.5 per cent and 93.0 per cent. The performance was consistent with previous reports and superior to that of a recent UK series. The high rate of inadequate samples is, however, a concern.Conclusion:Head and neck cytology is a robust technique at our institution, although there are certain problem areas. There is room for improvement in the technical quality of fine needle aspiration.


Author(s):  
Ashok Kumar K. ◽  
Sathya P. ◽  
Sreelatha Sampathkumar

Background: Abnormal uterine bleeding in women is the commonest presenting complaint which accounts for one third of all gynecological consultations. It not only causes discomfort, inconvenience to healthy women but also affects their quality of life and impose financial burden on them. This insists the physician to diagnose its etiology and provide appropriate treatment. Hysteroscopy guided biopsy is a simple, safe, reliable procedure in the diagnosis of abnormal uterine bleeding. The objective of the study was to evaluate the uterine pathology in premenopausal women with abnormal uterine bleeding by hysteroscopy.Methods: This prospective study was conducted at ESIC-MC and PGIMSR, Rajajinagar, Bangalore, in 50 premenopausal women with abnormal uterine bleeding over 18 months from Dec 2012 to May 2014. All 50 women were subjected to diagnostic hysteroscopy followed by curettage. The sample was sent to histopathological examination. Data was collected and analyzed.Results: In the present study, abnormal uterine bleeding was more common in 41-45yrs of age. The commonest presenting complaint was heavy menstrual bleeding (menorrhagia) in 54% of cases. The abnormal findings on hysteroscopy were: Hyperplasia 42%, endometrial polyp 22%, sub-mucous myoma 4%, carcinoma endometrium 2%, synechiae 2% and endometritis 2%. Negative hysteroscopic view was seen in 26%. The sensitivity, specificity, positive and negative predictive value of hysteroscopy was 91.89%, 92.31%, 97.14% and 80% respectively. The overall diagnostic accuracy of hysteroscopy was 92%.Conclusions: Hysteroscopy and its directed biopsy renders high diagnostic accuracy in patients with abnormal uterine bleeding and thereby guiding them for further management.


Author(s):  
Ling-Yu Guo ◽  
Phyllis Schneider ◽  
William Harrison

Purpose This study provided reference data and examined psychometric properties for clausal density (CD; i.e., number of clauses per utterance) in children between ages 4 and 9 years from the database of the Edmonton Narrative Norms Instrument (ENNI). Method Participants in the ENNI database included 300 children with typical language (TL) and 77 children with language impairment (LI) between the ages of 4;0 (years;months) and 9;11. Narrative samples were collected using a story generation task, in which children were asked to tell stories based on six picture sequences. CD was computed from the narrative samples. The split-half reliability, concurrent criterion validity, and diagnostic accuracy were evaluated for CD by age. Results CD scores increased significantly between ages 4 and 9 years in children with TL and those with LI. Children with TL produced higher CD scores than those with LI at each age level. In addition, the correlation coefficients for the split-half reliability and concurrent criterion validity of CD scores were all significant at each age level, with the magnitude ranging from small to large. The diagnostic accuracy of CD scores, as revealed by sensitivity, specificity, and likelihood ratios, was poor. Conclusions The finding on diagnostic accuracy did not support the use of CD for identifying children with LI between ages 4 and 9 years. However, given the attested reliability and validity for CD, reference data of CD from the ENNI database can be used for evaluating children's difficulties with complex syntax and monitoring their change over time. Supplemental Material https://doi.org/10.23641/asha.13172129


2006 ◽  
Vol 175 (4S) ◽  
pp. 551-552
Author(s):  
Erich K. Lang ◽  
Richard J. Macchia ◽  
Raju Thomas ◽  
Ronald Davis ◽  
Douglas Slakey ◽  
...  

2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


DeKaVe ◽  
2013 ◽  
Vol 1 (2) ◽  
Author(s):  
Prayanto WH

Magazine is one of the forms of mass media that has fungsikomunikasi to convey information to mass audiences. The cover is an important element because it is through cover / cover one can guess the contents of the magazine, as well as further interested to know further information contained therein. On a magazine cover consists of drawings and writings are arranged in such a way that looks interesting and has meaning Press publications, especially magazines, today's not enough just to rely on the quality of news or manuscript, although verbal aspect is very important. It must be recognized that the visual aspects (design) as the cover / envelope has crucial role to capture the prospective reader. For the cover of a magazine is a window that shows the content information, can be either a text or photographs, illustrations, and design elements. The function of a magazine cover is to attract, dazzle prospective readers, by way influence the thoughts flow in a short time. So it's no wonder much current the magazine publisher who made the cover of such a way as to attract the attention of prospective readers. Thus the task of designers to magazine cover to create designs that attract the attention of the reader becomes increasingly severe. This study tries to analyze a visual on the front cover Magazine Graphic Design 'Concept' birthday inaugural edition by using the Roland Barthes' semiotic approach. As Roland Barthes (1984), any simple "design work (magazine cover)" continue to play in management of the sign. So that will generate a message (image) specific. Design cover, usually contains the elements of the sign in the form of objects, context of the environment, people or other beings who provide meaning to objects, and text (of writing) that reinforce the meaning.Keyword: cover, magazine Concept, semiotics


2020 ◽  
Vol 41 (4) ◽  
pp. 240-247
Author(s):  
Lei Yang ◽  
Qingtao Zhao ◽  
Shuyu Wang

Background: Serum periostin has been proposed as a noninvasive biomarker for asthma diagnosis and management. However, its accuracy for the diagnosis of asthma in different populations is not completely clear. Methods: This meta-analysis aimed to evaluate the diagnostic accuracy of periostin level in the clinical determination of asthma. Several medical literature data bases were searched for relevant studies through December 1, 2019. The numbers of patients with true-positive, false-positive, false-negative, and true-negative results for the periostin level were extracted from each individual study. We assessed the risk of bias by using Quality Assessment of Diagnostic Accuracy Studies 2. We used the meta-analysis to produce summary estimates of accuracy. Results: In total, nine studies with 1757 subjects met the inclusion criteria. The pooled estimates of sensitivity, specificity, and diagnostic odds ratios for the detection of asthma were 0.58 (95% confidence interval [CI], 0.38‐0.76), 0.86 (95% CI, 0.74‐0.93), and 8.28 (95% CI, 3.67‐18.68), respectively. The area under the summary receiver operating characteristic curve was 0.82 (95% CI, 0.79‐0.85). And significant publication bias was found in this meta‐analysis (p = 0.39). Conclusion: Serum periostin may be used for the diagnosis of asthma, with moderate diagnostic accuracy.


2008 ◽  
Vol 47 (01) ◽  
pp. 37-42 ◽  
Author(s):  
T. Pfluger ◽  
V. Schneider ◽  
M. Hacker ◽  
N. Bröckel ◽  
D. Morhard ◽  
...  

SummaryAim: Assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [18F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CECT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for >6 months. Results: Region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/ CE-CT as compared to PET/LD-CT. Conclusion: Overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma.


Sign in / Sign up

Export Citation Format

Share Document