scholarly journals Experimental Quantification on the Residual Seismic Capacity of Damaged RC Column Members

Author(s):  
Chien-Kuo Chiu ◽  
Hsin-Fang Sung ◽  
Kai-Ning Chi ◽  
Fu-Pei Hsiao

Abstract To quantify the post-earthquake residual seismic capacity of reinforced concrete (RC) column members, experimental data for 6 column specimens with flexural, flexural–shear and shear failure modes are used to derive residual seismic capacity of damaged RC column members for specified damage states in this work. Besides of the experiment data, some related researches are also investigated to suggest the reduction factors of strength, stiffness and energy dissipation capacity for damaged RC column members, respectively. According to the damage states of RC columns, their corresponding seismic reduction factors are suggested herein. Taking an RC column with the flexural–shear failure for an example, its reductions factors of strength, stiffness and energy dissipation capacity are 0.5, 0.6 and 0.1, respectively. This work also proposes the seismic performance assessment method for the residual seismic performance of earthquake-damaged RC buildings. In the case study, this work selects one actual earthquake-damaged school building to demonstrate the post-earthquake assessment of seismic performance for a damaged RC building.

2018 ◽  
Vol 22 (6) ◽  
pp. 1312-1328 ◽  
Author(s):  
Jianyang Xue ◽  
Rui Guo ◽  
Liangjie Qi ◽  
Dan Xu

The majority of existing ancient timber structures have different degrees of damage. The looseness of mortise-tenon joints is a kind of typical damage type. In order to study the influence of looseness on the seismic performance of mortise-tenon joints, six through-tenon joints and six dovetail-tenon joints with scale 1:3.2 were fabricated according to the requirements of the engineering fabrication method of Chinese Qing Dynasty. Each type of joints consisted of one intact joint and five artificial loose joints, and the artificial defect was made to simulate looseness by cutting the tenon sectional dimension. Based on experiments of two types of joints under low-cyclic reversed loading, the seismic behaviors of joints such as failure modes, hysteretic loops and skeleton curves, strength and stiffness degradation, and energy dissipation capacity were studied. Moreover, the comparative analyses of seismic performance between two types of joints were carried out. The variation tendency of seismic behaviors of two types of joints has similarities, and there are some differences due to their different structural styles. The results indicate that squeeze deformation between tenon and mortise of two types of joints occurred. The shape of hysteretic loops of two types of joints is reverse-Z-shape, and the pinching effect of hysteretic loops becomes more obvious with the increase in looseness, among which of through-tenon joints is more obvious than that of dovetail-tenon joints. The carrying capacity, stiffness, and energy dissipation capacity of loose joints are significantly lower than that of the intact one, and the energy dissipation capacity of dovetail-tenon joints is better than that of through-tenon joints. The rotation angles of two types of joints can reach 0.12 rad, and the loose joints still have great deformation capacity.


2013 ◽  
Vol 790 ◽  
pp. 247-251
Author(s):  
Li Ting Dong ◽  
Yan Wang

Based on node test and finite element analysis results of four different structural form enhanced nodes,failure modes,hysteretic behavior,bearing capacity,ductility and energy dissipation capacity of nodes are analyzed comprehensively and comparatively for more in-depth exploration about the seismic performance of symmetric enhanced nodes.The results showed that all the symmetric enhanced nodes have full hysteretic curve and energy dissipation capacity. On the whole,The flange-plate reinforced node exhibit better seismic performance.


2020 ◽  
pp. 136943322098272
Author(s):  
Hui Su ◽  
Wei Chen ◽  
Dongyue Wu ◽  
Qing Wu ◽  
Shiling Wang ◽  
...  

The seismic performance of the precast shear wall was improved by using a newly developed reinforced tenon to strengthen the precast joint, which is used to bear the shear force of the precast joint and reduce the effect of dowel action on the vertical connecting steel bars. The vertical connecting steel bars were only used to bear tensile and compressive stress and consume seismic energy. The seismic performance of reinforced tenon precast shear wall was investigated by quasi-static tests on one reinforced tenon precast shear wall specimen and one ordinary flat seam precast shear wall specimen. This study investigated the crack distribution and failure modes, precast joint slip of the two specimens, and the seismic performance parameters such as bearing capacity, stiffness degradation, ductility performance and energy dissipation capacity. The test results demonstrated that the reinforced tenon effectively reduced the slip of the joint surface and exhibited good ductility and energy dissipation capacity than that of the ordinary flat seam specimen, while the failure mode, bearing capacity, and stiffness were similar to that of the flat seam specimen.


2022 ◽  
pp. 136943322110572
Author(s):  
Xun Chong ◽  
Pu Huo ◽  
Linlin Xie ◽  
Qing Jiang ◽  
Linbing Hou ◽  
...  

A new connection measure between the precast concrete (PC) cladding panel and PC frame structure is proposed to realize a new kind of isostatic frame-cladding system. Three full-scale PC wall-frame substructures were tested under the quasi-static load. These substructures included a bare wall-frame specimen, a specimen with a cladding panel that has no opening, and a specimen with a cladding panel that has an opening in it. The damage evolution, failure mode, load-bearing capacity, deformation capacity, and energy dissipation capacity of three specimens were compared. The results indicated that the motions of the cladding panels and the main structures were uncoupled through the relative clearance of the bottom connections, and three specimens exhibited approximately identical failure modes and seismic performance. Thus, the reliability of this new isostatic system was validated.


2015 ◽  
Vol 9 (1) ◽  
pp. 295-307 ◽  
Author(s):  
Edelis del V. Marquez A. ◽  
William Lobo-Q ◽  
Juan C. Vielma

A comparative study has been done to analyze the behavior of regular steel building structures of 4, 6, 8 and 10 stories, located in seismic zone 5 and soil type S1. The structures were upgraded with different brace configurations according to current Venezuelan codes. A total number of 24 numerical models were analyzed considering non-linear static and incremental dynamic analysis (IDA). The buildings were initially designed as moment resisting frames, and upgraded with six different bracing configurations: concentric braces in “X” and inverted “V”; eccentric braces inverted "V" with horizontal links, inverted “Y” and “X” with vertical links. Short length links were used to ensure a shear failure. The used methodology is based on obtaining the capacity, IDA curves, and bilinear approximations of these curves that allow the determination of yield and ultimate capacity points, in order to estimate important parameters of seismic response: overstrength and ductility; and considering these areas under the curves to estimate elastic deformation energy, energy dissipated by hysteretic damping and equivalent damping. According to the results, the cases with no brace enhancement showed the lowest lateral strength and lateral stiffness and high deformation capacity. On the other hand, the concentric bracing cases, resulted with the highest stiffness and strength and the lowest deformation capacity, therefore they have low ductility and energy dissipation capacity under seismic loading. Structures with links showed intermediate stiffness and strengths, resulting in the best performance in terms of ductility and energy dissipation capacity. The present study provides a better understanding of the benefits of eccentrically braced systems.


2019 ◽  
Vol 2019 ◽  
pp. 1-14
Author(s):  
Zhen-chao Teng ◽  
Tian-jia Zhao ◽  
Yu Liu

In traditional building construction, the structural columns restrict the design of the buildings and the layout of furniture, so the use of specially shaped columns came into being. The finite element model of a reinforced concrete framework using specially shaped columns was established by using the ABAQUS software. The effects of concrete strength, reinforcement ratio, and axial compression ratio on the seismic performance of the building incorporating such columns were studied. The numerical analysis was performed for a ten-frame structure with specially shaped columns under low reversed cyclic loading. The load-displacement curve, peak load, ductility coefficient, energy dissipation capacity, and stiffness degradation curve of the specially shaped column frame were obtained using the ABAQUS finite element software. The following three results were obtained from the investigation: First, when the strength of concrete in the specially shaped column frame structure was increased, the peak load increased, while the ductility and energy dissipation capacity weakened, which accelerated the stiffness degradation of the structure. Second, when the reinforcement ratio was increased in the specially shaped column frame structure, the peak load increased and the ductility and energy dissipation capacity also increased, which increased the stiffness of the structure. Third, when the axial compression ratio was increased in the structure, the peak load increased, while ductility and energy dissipation capacity reduced, which accelerated the degradation of structural stiffness.


Materials ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 2716 ◽  
Author(s):  
Shiming Liu ◽  
Xinxin Ding ◽  
Xiaoke Li ◽  
Yongjian Liu ◽  
Shunbo Zhao

This paper studies the effect of high-strength steel fiber reinforced concrete (SFRC) on the axial compression behavior of rectangular-sectional SFRC-filled steel tube columns. The purpose is to improve the integrated bearing capacity of these composite columns. Nine rectangular-sectional SFRC-filled steel tube columns and one normal concrete-filled steel tube column were designed and tested under axial loading to failure. The compressive strength of concrete, the volume fraction of steel fiber, the type of internal longitudinal stiffener and the spacing of circular holes in perfobond rib were considered as the main parameters. The failure modes, axial load-deformation curves, energy dissipation capacity, axial bearing capacity, and ductility index are presented. The results identified that steel fiber delayed the local buckling of steel tube and increased the ductility and energy dissipation capacity of the columns when the volume fraction of steel fiber was not less than 0.8%. The longitudinal internal stiffening ribs and their type changed the failure modes of the local buckling of steel tube, and perfobond ribs increased the ductility and energy dissipation capacity to some degree. The compressive strength of SFRC failed to change the failure modes, but had a significant impact on the energy dissipation capacity, bearing capacity, and ductility. The predictive formulas for the bearing capacity and ductility index of rectangular-sectional SFRC-filled steel tube columns are proposed to be used in engineering practice.


2013 ◽  
Vol 680 ◽  
pp. 234-238
Author(s):  
Jin Li Qiao ◽  
Wen Ling Tian ◽  
Ming Jie Zhou ◽  
Fang Lu Jiang ◽  
Kun Zhao

In order to validate the seismic performance of reinforced concrete grid-mesh frame wall , four grid frame walls in half size is made with different height-width ratios and different grid forms in the paper. Two of them are filling with cast-in-place plaster as filling material. According to the experimental results of these four walls subjected to horizontal reciprocating loads, we know that the grid-mesh frame wall's breaking form are in stages and multiple modes, and the main influencing factors are height-width ratio and grid form, what's more, with cast-in-place plaster as fill material, could not only improve the level of the wall bearing capacity and stiffness, but also improve the ductility and seismic energy dissipation capacity.


2013 ◽  
Vol 479-480 ◽  
pp. 1170-1174
Author(s):  
Hee Cheul Kim ◽  
Dae Jin Kim ◽  
Min Sook Kim ◽  
Young Hak Lee

The purpose of this study was to evaluate seismic performance of rehabilitated beam-column joint using FRP sheets and Buckling Restrained Braces (BRBs) and provide test data related to rehabilitated beam-column joints in reinforced concrete structures. The seismic performance of total six beam-column specimens is evaluated under cyclic loadings in terms of shear strength, effective stiffness, energy dissipation and ductility. The test results showed wrapping FRP sheets can contribute to increase the effect of confinement and the crack delay. Also retrofitting buckling restrained braces (BRBs) can improve the stiffness and energy dissipation capacity. Both FRP sheets and BRBs can effectively improve the strength, stiffness and ductility of seismically deficient beam-column joints.


2019 ◽  
Vol 6 (4) ◽  
pp. 181965 ◽  
Author(s):  
Jia Suizi ◽  
Cao Wanlin ◽  
Liu Zibin

This study developed a low-energy consumption composite wall structure constructed with a pre-fabricated lightweight steel frame that is suitable for houses in villages and towns and evaluated its anti-seismic performance. A low-reversed cyclic-loading test was conducted on four full-scale pre-fabricated structure specimens, including a lightweight, concrete-filled steel tube (CFST) column frame specimen (abbreviated as SFCF), a lightweight CFST column frame composite wall specimen (abbreviated as SFCFW), an H-steel column frame specimen (abbreviated as HSCF) and an H-steel column frame composite wall specimen (abbreviated as HSCFW). The failure characteristics, hysteretic behaviour, strength, rigidity, ductility and energy dissipation capacity of each specimen were compared and analysed. The results demonstrated that the pre-fabricated, double L-shaped beam–column joint with a stiffener rib which was proposed in this study worked reliably and exhibited good anti-seismic performance. The yield, ultimate and frame yield loads of the specimen SFCFW were 1.72, 1.80 and 2.03 times higher than those of specimen SFCF. The yield load, ultimate load and frame yield loads of specimen HSCFW were 1.27, 1.68 and 1.82 times higher than those of specimen HSCF. This indicates that the embedded composite wall contributed significantly to the horizontal bearing capacities of the SFCF and HSCF specimens. The embedded composite wall was divided into multiple strip-shaped composite panels during failure and achieved a stable support for the frame in the later stages of elastoplastic deformation. The horizontal strips of the tongue-and-groove connection between the strip-shaped composite panels produced reciprocating bite displacements, and ultimately improved the structure's energy dissipation capacity significantly.


Sign in / Sign up

Export Citation Format

Share Document