Orange Peeling : An Innovative Fixed Tooth Preparation Technique = Orange Peeling : Une Technique Innovante de Préparation des Dents en Prothèses Fixées

2020 ◽  
Vol 11 (1) ◽  
pp. 19-23
Author(s):  
Rayyan , Mohammad ◽  
Maarouf , Rima ◽  
Alarji , Ammar
Author(s):  
Haiyang Yu ◽  
Yuwei Zhao ◽  
Junying Li ◽  
Tian Luo ◽  
Jing Gao ◽  
...  

Abstract By removing a part of the structure, the tooth preparation provides restorative space, bonding surface, and finish line for various restorations on abutment. Preparation technique plays critical role in achieving the optimal result of tooth preparation. With successful application of microscope in endodontics for >30 years, there is a full expectation of microscopic dentistry. However, as relatively little progress has been made in the application of microscopic dentistry in prosthodontics, the following assumptions have been proposed: Is it suitable to choose the tooth preparation technique under the naked eye in the microscopic vision? Is there a more accurate preparation technology intended for the microscope? To obtain long-term stable therapeutic effects, is it much easier to achieve maximum tooth preservation and retinal protection and maintain periodontal tissue and oral function health under microscopic vision? Whether the microscopic prosthodontics is a gimmick or a breakthrough in obtaining an ideal tooth preparation should be resolved in microscopic tooth preparation. This article attempts to illustrate the concept, core elements, and indications of microscopic minimally invasive tooth preparation, physiological basis of dental pulp, periodontium and functions involved in tool preparation, position ergonomics and visual basis for dentists, comparison of tooth preparation by naked eyes and a microscope, and comparison of different designs of microscopic minimally invasive tooth preparation techniques. Furthermore, a clinical protocol for microscopic minimally invasive tooth preparation based on target restorative space guide plate has been put forward and new insights on the quantity and shape of microscopic minimally invasive tooth preparation has been provided.


2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Fusong Yuan ◽  
Yong Wang ◽  
Yaopeng Zhang ◽  
Yuchun Sun ◽  
Dangxiao Wang ◽  
...  

2016 ◽  
Vol 12 (6) ◽  
pp. 290
Author(s):  
Rozafa Dragusha ◽  
Djemal Ibraimi

Today, in restorative and prosthodontic dental treatments, the focus is on aesthetics. This involves meeting the needs and expectations of the patient. Failures occur not only as a result of technical problems, but also as a result of poor communication with the patient. To avoid these scenarios that may obligate us to repeat the restoration from the beginning, we can obtain help by using Mock-up. Despite communication with the diagnostic and treatment planning step, Mock-up enables us to control the function of the end result without even beginning the work. It also enables us to do a minimal invasive tooth preparation. The aim of this study is to use Mock-up to show its effectiveness in communication, planning, and preparation to achieve the demanded aesthetic dental treatment. Materials and Methods: We prepared mock-up according to wax-up in the second meeting- the treatment planning step. We used a minimal invasive, mock-up guided, preparation technique from the Mock-up accepted by us and the patient. Results: This easy and practical method enabled us to avoid the intervention in the ultimate restoration. Our result is in accordance with those of other authors: we had minimal preparation, even some unprepared surfaces and satisfied patient. Conclusions: The use of Mock-up is a simple technique in aesthetic dentistry. Broadly in prosthodontics, it assures us that the work will be functionally and aesthetically successful.


Author(s):  
M. Talianker ◽  
D.G. Brandon

A new specimen preparation technique for visualizing macromolecules by conventional transmission electron microscopy has been developed. In this technique the biopolymer-molecule is embedded in a thin monocrystalline gold foil. Such embedding can be performed in the following way: the biopolymer is deposited on an epitaxially-grown thin single-crystal gold film. The molecule is then occluded by further epitaxial growth. In such an epitaxial sandwich an occluded molecule is expected to behave as a crystal-lattice defect and give rise to contrast in the electron microscope.The resolution of the method should be limited only by the precision with which the epitaxially grown gold reflects the details of the molecular structure and, in favorable cases, can approach the lattice resolution limit.In order to estimate the strength of the contrast due to the void-effect arising from occlusion of the DNA-molecule in a gold crystal some calculations were performed.


Author(s):  
F. Thoma ◽  
TH. Koller

Under a variety of electron microscope specimen preparation techniques different forms of chromatin appearance can be distinguished: beads-on-a-string, a 100 Å nucleofilament, a 250 Å fiber and a compact 300 to 500 Å fiber.Using a standardized specimen preparation technique we wanted to find out whether there is any relation between these different forms of chromatin or not. We show that with increasing ionic strength a chromatin fiber consisting of a row of nucleo- somes progressively folds up into a solenoid-like structure with a diameter of about 300 Å.For the preparation of chromatin for electron microscopy the avoidance of stretching artifacts during adsorption to the carbon supports is of utmost importance. The samples are fixed with 0.1% glutaraldehyde at 4°C for at least 12 hrs. The material was usually examined between 24 and 48 hrs after the onset of fixation.


Author(s):  
Jayesh Bellare

Seeing is believing, but only after the sample preparation technique has received a systematic study and a full record is made of the treatment the sample gets.For microstructured liquids and suspensions, fast-freeze thermal fixation and cold-stage microscopy is perhaps the least artifact-laden technique. In the double-film specimen preparation technique, a layer of liquid sample is trapped between 100- and 400-mesh polymer (polyimide, PI) coated grids. Blotting against filter paper drains excess liquid and provides a thin specimen, which is fast-frozen by plunging into liquid nitrogen. This frozen sandwich (Fig. 1) is mounted in a cooling holder and viewed in TEM.Though extremely promising for visualization of liquid microstructures, this double-film technique suffers from a) ireproducibility and nonuniformity of sample thickness, b) low yield of imageable grid squares and c) nonuniform spatial distribution of particulates, which results in fewer being imaged.


Author(s):  
S.R. Glanvill

This paper summarizes the application of ultramicrotomy as a specimen preparation technique for some of the Materials Science applications encountered over the past two years. Specimens 20 nm thick by hundreds of μm lateral dimension are readily prepared for electron beam analysis. Materials examined include metals, plastics, ceramics, superconductors, glassy carbons and semiconductors. We have obtain chemical and structural information from these materials using HRTEM, CBED, EDX and EELS analysis. This technique has enabled cross-sectional analysis of surfaces and interfaces of engineering materials and solid state electronic devices, as well as interdiffusion studies across adjacent layers.Samples are embedded in flat embedding moulds with Epon 812 epoxy resin / Methyl Nadic Anhydride mixture, using DY064 accelerator to promote the reaction. The embedded material is vacuum processed to remove trapped air bubbles, thereby improving the strength and sectioning qualities of the cured block. The resin mixture is cured at 60 °C for a period of 80 hr and left to equilibrate at room temperature.


Author(s):  
J. C. Barry ◽  
H. Alexander

Dislocations in silicon produced by plastic deformation are generally dissociated into partials. 60° dislocations (Burgers vector type 1/2[101]) are dissociated into 30°(Burgers vector type 1/6[211]) and 90°(Burgers vector type 1/6[112]) dislocations. The 30° partials may be either of “glide” or “shuffle” type. Lattice images of the 30° dislocation have been obtained with a JEM 100B, and with a JEM 200Cx. In the aforementioned experiments a reasonable but imperfect match was obtained with calculated images for the “glide” model. In the present experiment direct structure images of 30° dislocation cores have been obtained with a JEOL 4000EX. It is possible to deduce the 30° dislocation core structure by direct inspection of the images. Dislocations were produced by compression of single crystal Si (sample preparation technique described in Alexander et al.).


Sign in / Sign up

Export Citation Format

Share Document