scholarly journals Resolution of Spurious Immunonephelometric IgG Subclass Measurement Discrepancies by LC-MS/MS

2018 ◽  
Vol 64 (4) ◽  
pp. 735-742 ◽  
Author(s):  
Grace van der Gugten ◽  
Mari L DeMarco ◽  
Luke Y C Chen ◽  
Alex Chin ◽  
Mollie Carruthers ◽  
...  

Abstract BACKGROUND The Binding Site immunonephelometric (IN) IgG subclass reagents (IgG1, IgG2, IgG3, IgG, BSIN) are used for assessment of both immunodeficiency and IgG4-related disease (IgG4-RD). In our laboratory, suspected analytic errors were noted in patients with increases in IgG4: The sum of the individual IgG subclasses was substantially greater than the measured total IgG concentrations (unlike samples with normal IgG4), and the IgG4 concentration was always less than the IgG2 concentration. METHODS We developed a tryptic digest LC-MS/MS method to quantify IgG1, IgG2, IgG3, and IgG4 in serum. Samples with IgG4 concentrations ranging from <0.03 g/L to 32 g/L were reanalyzed by LC-MS/MS, and a subset was also reanalyzed by Siemens IN (SIN) subclass measurements. RESULTS Multivariate linear regression identified 3 subclass tests with multiple predictors of the measured subclass concentration. For these 3 subclasses, the predominant predictors were (in terms of LC-MS/MS IgG subclass measurement coefficients) BSIN IgG1 = 0.89·IgG1 + 0.4·IgG4; BSIN IgG2 = 0.94·IgG4 + 0.89·IgG2; and SIN IgG2 = 0.72·IgG2 + 0.24·IgG4. CONCLUSIONS There is apparent IgG4 cross-reactivity with select IN subclass measurements affecting tests from both vendors tested. These findings can be explained either by direct cross-reactivity of the IN reagents with the IgG4 subclass or unique physicochemical properties of IgG4 that permit nonspecific binding of IgG4 heavy chain to other IgG immunoglobulin heavy chains. Irrespective of the mechanism, the observed intermethod discrepancies support the use of LC-MS/MS as the preferred method for measurement of IgG subclasses when testing patients with suspected IgG4-RD.

2018 ◽  
Vol 56 (8) ◽  
pp. 1319-1327 ◽  
Author(s):  
Olivier Grunewald ◽  
Benjamin Lopez ◽  
Séverine Brabant ◽  
Stéphanie Rogeau ◽  
Antoine Deschildre ◽  
...  

Abstract Background: Immunoglobulin G (IgG) and IgG subclass assays are indicated in patients with suspected primary immunodeficiency (PID). Commercially available assays for IgG subclass determination are calibrated against various preparations, and so specific reference values are required for each of them. Using Optilite® reagents from The Binding Site Group Ltd., we sought to determine the pediatric IgG and IgG subclass reference intervals with respect to the ERM-DA470k certified reference material. Methods: Levels of IgG and IgG subclasses were analyzed in serum samples collected from a large cohort of PID-free children and adolescents. Reference intervals were calculated for previously published age groups (6–12 months, 12–18 months, 18 months–2 years, 2–3 years, 3–4 years, 4–6 years, 6–9 years, 9–12 years and 12–18 years), according to the Clinical and Laboratory Standards Institute’s C28-A3c protocol. Results: A total of 456 serum samples were analyzed. The correlation between the total IgG and the sum of the IgG subclasses was good (r2=0.96). No statistically significant gender-specific differences were observed. Our results for the changes over time in IgG and IgG subclass levels are consistent with previous reports. The differences between our lower/upper reference limits and those in the literature are probably due to variations in calibration. Conclusions: Our present results provide a reliable basis for the diagnosis of PIDs in childhood and for the accreditation of laboratories using Optilite® immunoturbidimetric reagents for IgG subclass measurement. Laboratory scientists and clinicians should be aware of the need for manufacturer-specific IgG subclass reference intervals.


PLoS ONE ◽  
2021 ◽  
Vol 16 (9) ◽  
pp. e0248444
Author(s):  
Dayu Zhang ◽  
Tianyang Xu ◽  
Eric Chu ◽  
Aiguo Zhang ◽  
Jinwei Du ◽  
...  

The pandemic of novel coronavirus disease COVID-19 is rapidly expanding across the world. A positive result of antibody tests suggests that the individual has potentially been exposed to SARS-CoV-2, thus allowing to identify asymptomatic infections and determine the seroprevalence in a given population. The aim of this study was to evaluate the performances of a newly developed high throughput immunoassay for anti-SARS-CoV-2 IgM antibody detection on the Luminex MAGPIX platform. Clinical agreement studies were performed in 42 COVID-19 patient serum samples and 162 negative donor serum/plasma samples. Positive percent agreement (PPA) was 42.86% (95% CI: 9.90% to 81.59%), 71.43% (95% CI: 29.04% to 96.33%), and 28.57% (95% CI: 13.22% to 48.67%) for samples collected on 0–7 days, 8–14 days, and 2–8 weeks from symptom onset, respectively. Negative Percent Agreement (NPA) was 97.53% (95% CI: 93.80% to 99.32%). There was no cross-reactivity with the SARS-CoV-2 IgG antibody. Hemoglobin (200 mg/dL), bilirubin (2 mg/dL), triglyceride (250 mg/dL) and EDTA (10 mM) showed no significant interfering effect on this assay. In conclusion, an anti-SARS-CoV-2 IgM antibody assay with high sensitivity and specificity has been developed. With the high throughput, this assay will speed up the anti-SARS-CoV-2 IgM testing.


2021 ◽  
Author(s):  
Dayu Zhang ◽  
Tianyang Xu ◽  
Eric Chu ◽  
Aiguo Zhang ◽  
Jinwei Du ◽  
...  

ABSTRACTThe pandemic of novel coronavirus disease COVID-19 is rapidly expanding across the world. A positive result of antibody tests suggests that the individual has potentially been exposed to SARS-CoV-2, thus allowing to identify asymptomatic infections and determine the seroprevalence in a given population. The aim of this study was to evaluate the performances of a newly developed high throughput immunoassay for anti-SARS-CoV-2 IgM antibody detection on the Luminex MAGPIX platform. Clinical agreement studies were performed in 42 COVID-19 patient serum samples and 162 negative donor serum/plasma samples. Positive percent agreement (PPA) was 42.86% (95% CI: 9.90% to 81.59%), 71.43% (95% CI: 29.04% to 96.33%), and 28.57% (95% CI: 13.22% to 48.67%) for samples collected on 0-7 days, 8-14 days, and 2-8 weeks from symptom onset, respectively. Negative Percent Agreement (NPA) was 97.53% (95% CI: 93.80% to 99.32%). There was no cross-reactivity with the SARS-CoV-2 IgG antibody Hemoglobin (200 mg/dL), bilirubin (2 mg/dL), triglyceride (250 mg/dL) and EDTA (10 mM) showed no significant interfering effect on this assay. In conclusion, an anti-SARS-CoV-2 IgM antibody assay with high sensitivity and specificity has been developed. With the high throughput, this assay will speed up the anti-SARS-CoV-2 IgM testing.


Biosensors ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 157
Author(s):  
Bárbara V. M. Silva ◽  
Marli T. Cordeiro ◽  
Marco A. B. Rodrigues ◽  
Ernesto T. A. Marques ◽  
Rosa F. Dutra

Zika virus (ZIKV) is a mosquito-borne infection, predominant in tropical and subtropical regions causing international concern due to the ZIKV disease having been associated with congenital disabilities, especially microcephaly and other congenital abnormalities in the fetus and newborns. Development of strategies that minimize the devastating impact by monitoring and preventing ZIKV transmission through sexual intercourse, especially in pregnant women, since no vaccine is yet available for the prevention or treatment, is critically important. ZIKV infection is generally asymptomatic and cross-reactivity with dengue virus (DENV) is a global concern. An innovative screen-printed electrode (SPE) was developed for amperometric detection of the non-structural protein (NS2B) of ZIKV by exploring the intrinsic redox catalytic activity of Prussian blue (PB), incorporated into a carbon nanotube–polypyrrole composite. Thus, this immunosensor has the advantage of electrochemical detection without adding any redox-probe solution (probe-less detection), allowing a point-of-care diagnosis. It was responsive to serum samples of only ZIKV positive patients and non-responsive to negative ZIKV patients, even if the sample was DENV positive, indicating a possible differential diagnosis between them by NS2B. All samples used here were confirmed by CDC protocols, and immunosensor responses were also checked in the supernatant of C6/36 and in Vero cell cultures infected with ZIKV.


2021 ◽  
Vol 6 (2) ◽  
pp. 84
Author(s):  
Dyah Ayu Widiasih ◽  
Johanna Frida Lindahl ◽  
Wayan T. Artama ◽  
Adi Heru Sutomo ◽  
Pande Made Kutanegara ◽  
...  

Leptospirosis is a zoonotic disease occurring worldwide with reproductive symptoms and production losses in livestock, while humans can suffer fatal renal failure. In Yogyakarta Special Province, Indonesia, there have been several outbreaks with high case fatality, demonstrating the public health importance, but there is limited understanding of the epidemiology. This study used an EcoHealth approach to ensure transdisciplinarity and community participation. Seroprevalence of Leptospira in animals was studied between October 2011 and May 2013 in 15 villages. Serum samples from 1404 cattle and 60 small ruminants were screened by a Microscopic Agglutination Test (MAT), first in pools, and then the individual positive samples were identified. Focus group discussions including farmers, village officials, and official stakeholders were used to explore knowledge and behavior of zoonotic diseases, particularly leptospirosis. Two small ruminants were seropositive for Leptospira icterohemorrhagiae. From the cattle, 3.7% were seropositive, and the most common serovars were Leptospira hardjo, followed by L. icterohemorrhagiae. Out of all farms, 5.6% had at least one positive cattle. Risk factor analyses showed that the risk of the farm being seropositive increased if the farmer used water from an open source, or if farming was not the main occupation. This study showed the presence of Leptospira spp. in ruminants in Yogyakarta and identified use of open water as a risk factor for the livestock. We also observed that the knowledge related to leptospirosis was low, and risky farm management practices were commonly employed.


Viruses ◽  
2021 ◽  
Vol 13 (3) ◽  
pp. 507
Author(s):  
Long Pham-Thanh ◽  
Thang Nguyen-Tien ◽  
Ulf Magnusson ◽  
Vuong Bui-Nghia ◽  
Anh Bui-Ngoc ◽  
...  

Diseases caused by flaviviruses, including dengue fever and Japanese encephalitis, are major health problems in Vietnam. This cross-sectional study explored the feasibility of domestic dogs as sentinels to better understand risks of mosquito-borne diseases in Hanoi city. A total of 475 dogs serum samples from 221 households in six districts of Hanoi were analyzed by a competitive enzyme-linked immunosorbent assay (cELISA) for antibodies to the pr-E protein of West Nile virus and other flaviviruses due to cross-reactivity. The overall flavivirus seroprevalence in the dog population was 70.7% (95% CI = 66.4–74.8%). At the animal level, significant associations between seropositive dogs and district location, age, breed and keeping practice were determined. At the household level, the major risk factors were rural and peri-urban locations, presence of pigs, coil burning and households without mosquito-borne disease experience (p < 0.05). Mosquito control by using larvicides or electric traps could lower seropositivity, but other measures did not contribute to significant risk mitigation of flavivirus exposure in dogs. These results will support better control of mosquito-borne diseases in Hanoi, and they indicate that dogs can be used as sentinels for flavivirus exposure.


2007 ◽  
Vol 15 (2) ◽  
pp. 297-302 ◽  
Author(s):  
Olga Sánchez Negrette ◽  
Fernando J. Sánchez Valdéz ◽  
Carlos D. Lacunza ◽  
María Fernanda García Bustos ◽  
María Celia Mora ◽  
...  

ABSTRACT Serological tests are the main laboratory procedures used for diagnosis during the indeterminate and chronic stages of Chagas' disease. A serological regression to negativity is the main criterion used to define parasitological cure in treated patients. The aim of this work was to monitor the individual specificities of antibody levels for 3 years posttreatment in 18 adult patients. Conventional serological techniques (hemagglutination assays and enzyme-linked immunosorbent assay [ELISA]) were modified by using recombinant antigens to detect early markers of treatment effectiveness. For this purpose, serum samples were taken before and during treatment and every 6 months after treatment for at least 3 years. When hemagglutination assays were used, a decrease in antibody levels was observed in only one patient. When ELISA with serum dilutions was used, antibody clearance became much more apparent: in 77.7% (14/18) of the patients, antibody titers became negative with time. This was observed at serum dilutions of 1/320 and occurred between the 6th and the 30th months posttreatment. The immune response and the interval for a serological regression to negativity were different for each patient. For some of the recombinant antigens, only 50% (9/18) of the patients reached the serological regression to negativity. Recombinant antigen 13 might be a good marker of treatment effectiveness, since 66.6% (six of nine) of the patients presented with an early regression to negativity for specific antibodies to this antigen (P = 0.002).


2011 ◽  
Vol 18 (7) ◽  
pp. 1183-1186 ◽  
Author(s):  
Pieter G. M. van Gageldonk ◽  
Christina von Hunolstein ◽  
Fiona R. M. van der Klis ◽  
Guy A. M. Berbers

ABSTRACTA nonspecific binding of antibodies to diphtheria toxin, especially in adult serum samples, was observed in our diphtheria-tetanus-pertussis multiplex immunoassay (DTaP4 MIA). This can be significantly reduced by the use of diphtheria toxoid, achieving a good correlation with the Vero cell neutralization test and the toxin binding inhibition assay.


2020 ◽  
Author(s):  
Beatriz Araujo Oliveira ◽  
Lea Campos de Oliveira ◽  
Franciane Mendes de Oliveira ◽  
Geovana Maria Pereira ◽  
Regina Maia de Souza ◽  
...  

AbstractBackgroundCOVID-19 disease (Coronavirus disease 2019) caused by SARS-CoV-2 (Severe acute respiratory syndrome coronavirus 2) is widespread worldwide, affecting more than 11 million people globally (July 6th, 2020). Diagnostic techniques have been studied in order to contain the pandemic. Immunochromatographic (IC) assays are feasible and low cost alternative for monitoring the spread of COVID-19 in the population.MethodsHere we evaluate the sensitivity and specificity of eleven different immunochromatographic tests in 98 serum samples from confirmed cases of COVID-19 through RT-PCR and 100 negative serum samples from blood donors collected in February 2019. Considering the endemic situation of Dengue in Brazil, we also evaluated the cross-reactivity with Dengue using 20 serum samples from patients with confirmed diagnosis for Dengue collected in early 2019 through four different tests.ResultsOur results demonstrated agreement between immunochromatographic assays and RT-PCR, especially after 10 days since the onset of symptoms. The evaluation of IgG and IgM antibodies combined demonstrated a strong level of agreement (0.85) of IC assays and RT-PCR. It was observed cross-reactivity between Dengue and COVID-19 using four different IC assays for COVID-19 diagnosis. The specificity of IC assays to detected COVID-19 IgM antibodies using Dengue serum samples varied from 80% to 85%; the specificity of IgG detection was 100% and total antibody was 95%.ConclusionsWe found high sensitivity, specificity and good agreement of IC assays, especially after 10 days onset of symptoms. However, we detected cross-reactivity between Dengue and COVID-19 mainly with IgM antibodies demonstrating the need for better studies about diagnostic techniques for these diseases.HighlightsImmunochromatographic assays demonstrated high sensitivity and specificity and good agreement with the gold-standard RT-PCR;Increase in sensitivity and specificity of assays using samples collected after the 10th day of symptoms;Cross-reaction with Dengue serology in evaluation of IgM.


2021 ◽  
Vol 12 ◽  
Author(s):  
Bochao Liu ◽  
Ze Wu ◽  
Chaolan Liang ◽  
Jinhui Lu ◽  
Jinfeng Li ◽  
...  

Since December 2019, a novel coronavirus (SARS-CoV-2) has resulted in a global pandemic of coronavirus disease (COVID-19). Although viral nucleic acid test (NAT) has been applied predominantly to detect SARS-CoV-2 RNA for confirmation diagnosis of COVID-19, an urgent need for alternative, rapid, and sensitive immunoassays is required for primary screening of virus. In this study, we developed a smartphone-based nanozyme-linked immunosorbent assay (SP-NLISA) for detecting the specific nucleocapsid phosphoprotein (NP) of SARS-CoV-2 in 37 serum samples from 20 COVID-19 patients who were diagnosed by NAT previously. By using SP-NLISA, 28/37 (75.7%) serum samples were detected for NP antigens and no cross-reactivity with blood donors’ control samples collected from different areas of China. In a control assay using the conventional enzyme-linked immunosorbent assay (ELISA), only 7/37 (18.91%) serum samples were detected for NP antigens and no cross-reactivity with control samples. SP-NLISA could be used for rapid detection of SARS-CoV-2 NP antigen in primary screening of SARS-CoV-2 infected individuals.


Sign in / Sign up

Export Citation Format

Share Document