Advanced Powder Feeding Device for Use in Gas/Solid Plasma Synthesis and Processing Applications

1987 ◽  
Vol 98 ◽  
Author(s):  
F. W. Giacobbe

ABSTRACTA series of powder feeders, developed during the course of an experimental study involving the synthesis of carbon monoxide from pure carbon and carbon dioxide, have been described in detail. The most efficient and reliable of these powder feeders was capable of continuously producing uniform mixtures of powdered carbon entrained in carbon dioxide gas. This device was also capable of producing a relatively wide range of solid/ gas mixture ratios (from about 0.8 to 3.2 g/l) at carbon dioxide gas flow rates between 75 and 200 1/min. In addition, it was relatively easy to vary and control solid/gas mixture ratios and gas flow rates using this powder feeder. Similar powder feeders may be useful in other thermal plasma synthesis or processing applications as well as in other applications requiring accurately blended mixtures of gases and powdered solids

Author(s):  
M. Nuckols ◽  
S. Kolaczkowski ◽  
S. Awdry ◽  
T. Smith ◽  
D. Thomas

Traditional CO2 absorption methods for underwater life support equipment use alkali metal hydroxide chemical beds — mostly calcium hydroxide — that have been shown to have poor absorption efficiencies at cold temperatures, and must be replaced at considerable trouble and expense on a frequent basis. With chemical utilizations as low as 20% in water temperatures of 2°C, these hydroxides do not lend themselves to applications requiring extended durations in cold water due to the inability to carry sufficient quantities of expendables. A joint research effort between Duke University and the University of Bath has verified the feasibility in laboratory trials of an alternative carbon dioxide removal method that intimately mixes seawater with breathing circuit gases within a packed bed of Dixon rings. Based on the results of these laboratory trials, two multi-path scrubber prototypes were designed and fabricated for unmanned testing. In March 2013, the hyperbaric performance of these prototype scrubbers was characterized over a wide range of gas and water flow rates when operating the scrubbers in counter-current (water flowing in the opposite direction as gas flow) and co-current (water flowing in the same direction as gas flow) fashion. Significant findings from these tests included the following: • Both scrubber prototypes were found to be capable of delivering exit CO2 levels below 0.5 vol% (surface equivalent) at respiratory rates up to 22.5 liters per minute and at depths ranging from 0 to 40 meters of seawater (MSW). • Negligible collateral O2 absorption was observed at surface pressure (exit O2 levels were typically above 20.2 vol%), and exit O2 levels were typically above 18.4% during testing at 10 MSW. • At surface pressure, both prototypes had significantly lower breathing resistances than design goals established by the U. S. Navy.


1997 ◽  
Vol 31 (4) ◽  
pp. 337-346 ◽  
Author(s):  
William Smith ◽  
Stephen B. Harrap

Our results showed more rapid falls in pulse rate and blood pressure in rats euthanized in a chamber precharged with carbon dioxide (CO2), when compared with rats euthanized more slowly, but death still took over 5 min in the former group. There was no behavioural evidence of pain or distress in either group during euthanasia. Initial ataxia and dyspnoea was punctuated by a lag before death, thus separating euthanasia into three clearly defined phases. All visual signs of death preceded complete vascular collapse by about 1 min in both groups, so we recommend that gas flow be maintained for at least 1 min after apparent death.


2009 ◽  
Vol 131 (5) ◽  
Author(s):  
Chungpyo Hong ◽  
Yutaka Asako ◽  
Jae-Heon Lee

The estimation of the gaseous leak flow rates through a narrow crack is important for a leak-before-break analysis as a method of nondestructive testing. Therefore, the methodology to estimate the gaseous leak flow rates in a narrow crack for a wide range of flow conditions, from no-slip to slip flow and from unchoked to choked flow, by using f⋅Re (the product of friction factor and Reynolds number) correlations obtained for a microchannel, was developed and presented. The correlations applied here were proposed by the previous study (Hong, et al., 2007, “Friction Factor Correlations for Gas Flow in Slip Flow Regime,” ASME J. Fluids Eng., 129, pp. 1268–1276). The detail of the calculation procedure was appropriately documented. The fourth-order Runge–Kutta method was employed to integrate the nonlinear ordinary differential equation for the pressure, and the regular-Falsi method was employed to find the inlet Mach number. An idealized crack, whose opening displacement ranges from 2 μm to 50 μm, with the crack aspect ratio of 200, 1000, and 2000, was chosen for sample estimation. The present results were compared with both numerical simulations and available experimental measurements. The results were in excellent agreement. Therefore, the gaseous leak flow rates can be correctly predicted by using the proposed methodology.


Author(s):  
Hélène Chaumat ◽  
Anne-Marie Billet ◽  
Henri Delmas

A detailed investigation of local hydrodynamics in a pilot plant bubble column has been performed using various techniques, exploring both axial and radial variations of the gas hold-up, bubble average diameter and frequency, surface area. A wide range of operating conditions has been explored up to large gas and liquid flow rates, with two sparger types. Two main complementary techniques were used: a quasi local measurement of gas hold-up via series of differential pressure sensors to get the axial variation and a double optic probe giving radial variations of gad hold-up, bubble average size and frequency and surface area.According to axial evolutions, three zones, where radial evolutions have been detailed, have been separated: at the bottom the gas injection zone, the large central region or column bulk and the disengagement zone at the column top. It was found that significant axial and radial variations of the two phase flow characteristics do exist even in the so called homogeneous regime. The normalized profiles of bubble frequency appear sparger and gas velocity independent contrary to bubble diameter, gas hold-up and interfacial area normalized profiles. In any case bubbles are larger in the sparger zone than elsewhere.The main result of this work is the very strong effect of liquid flow on bubble column hydrodynamics at low gas flow rate. First the flow regime map observed in batch mode is dramatically modified with a drastic reduction of the homogeneous regime region, up to a complete heterogeneous regime in the working conditions (uG> 0.02 m/s). On the contrary, liquid flow has limited effects at very high gas flow rates.A large data bank is provided to be used for example in detailed comparison with CFD calculations.


2019 ◽  
Author(s):  
Mohammad Ismail ◽  
Alsubheen A Sana'a ◽  
Angela Loucks-Atlinson ◽  
Matthew Atkinson ◽  
Liam P Kelly ◽  
...  

Objective: Indirect calorimetry (IC) systems measure the fractions of expired carbon dioxide (FECO2) and oxygen (FEO2) recorded at the mouth in order to estimate whole body energy production (EP). The fundamental principal of IC relates to oxidative mechanisms, expressed as rate of oxygen uptake (V̇O2) and carbon dioxide production (V̇CO2). From these volumes we calculate energy production and respiratory exchange ratio which is used to estimate substrate utilization rates. The accuracy of IC systems is critical to detect small changes in respiratory gas exchanges. The aim of this technical report was to assess the accuracy and linearity of IC systems using multiple propane gas flow rates procedure. Approach: A series of propane gas with different flow rates and ventilation rates were run on three different IC systems. The actual experimental V̇O2 and V̇CO2 were calculated and compared to stoichiometry theoretical values. Results: showed a linear relationship between gas volumes (V̇O2 and V̇CO2) and propane gas flows (99.6%, 99.2%, 94.8% for the Sable, Moxus, and Jaeger metabolic carts, respectively). In terms of system error, Jaeger system had significantly (p < 0.001) greater V̇O2 (M = -0.057, SE = 0.004), and V̇CO2 (M = -0.048, SE = 0.002) error compared to either the Sable (V̇O2, M = 0.044, SE = 0.004; V̇CO2, M = 0.024, SE = 0.002) or the Moxus (V̇O2, M = 0.046, SE = 0.004; V̇CO2, M = 0.025, SE = 0.002) metabolic carts. There were no significant differences between the Sable or Moxus metabolic carts. Conclusion: The multiple flow rates approach permitted the assessment of linearity of IC systems in addition to determining the accuracy of fractions of expired gases.


2008 ◽  
Vol 45 (5) ◽  
pp. 39-47
Author(s):  
A. Falade ◽  
A. Olaberinjo ◽  
M. Oyewola ◽  
F. Babalola ◽  
S. Adaramola

KPIM of Gas Transportation: Robust Modification of Gas Pipeline Equations Studies of the flow conditions of natural gases in pipelines have led to the development of complex equations for relating the volume transmitted through a gas pipeline to the various factors involved, thus deciding the optimum pressures and pipeline dimensions to be used. From equations of this type, various combinations of pipe diameter and wall thickness for a desired rate of gas throughput can be calculated. This research work presents modified forms of the basic gas flow equation for horizontal flow developed by Weymouth and the basic gas flow equation for inclined flow developed by Ferguson. The modified equations incorporate non-iterative forms of the Colebrook-White friction factor into the original forms of the Weymouth's and Ferguson's equations. These modified equations thus eliminate the need for iteration in predicting the flow rate of gas through pipelines as is the case with their original forms when the Colebrook-White friction factor is used. The modified equations also have a wider range of application since the Colebrook-White friction factor is valid for turbulent gas flow as well as for gas flow in a transition zone. On comparing the results it can be seen that the modified Ferguson's equation gives a more accurate prediction of gas flow rates because it takes the pipeline elevation into account. Lower deviations from measured gas flow rates were observed with the modified Ferguson's equation than with the modified basic gas flow equation. The deviations observed using the modified Ferguson equation were found to range from -0.16% to +3.21%. Conclusively, these less cumbersome newly developed equations with high degree reliability will be useful in predicting the rates of gas flow for a wide range of its conditions, pipeline elevation and pipeline lengths.


Author(s):  
M. Ellis ◽  
C. Kurwitz ◽  
F. Best

In the microgravity environment experienced by space vehicles, liquid and gas do not naturally separate as on Earth. This behavior presents a problem for two-phase space systems, such as environment conditioning, waste water processing, and power systems. Furthermore, with recent renewed interest in space nuclear power systems, a microgravity Rankine cycle is attractive for thermal to electric energy conversion and would require a phase separation device. Responding to this need, researchers have conceived various methods of producing phase separation in low gravity environments. These separator types have included wicking, elbow, hydrophobic/hydrophilic, vortex, rotary fan separators, and combinations thereof. Each class of separator achieved acceptable performance for particular applications and most performed in some capacity for the space program. However, increased integration of multiphase systems requires a separator design adaptable to a variety of system operating conditions. To this end, researchers at Texas A&M University (TAMU) have developed a Microgravity Vortex Separator (MVS) capable of handling both a wide range of inlet conditions as well as changes in these conditions with a single, passive design. Currently, rotary separators are recognized as the most versatile microgravity separation technology. However, compared with passive designs, rotary separators suffer from higher power consumption, more complicated mechanical design, and higher maintenance requirements than passive separators. Furthermore, research completed over the past decade has shown the MVS more resistant to inlet flow variations and versatile in application. Most investigations were conducted as part of system integration experiments including, among others, propellant transfer, waste water processing, and fuel cell systems. Testing involved determination of hydrodynamic conditions relating to vortex stability, inlet quality effects, accumulation volume potential, and dynamic volume monitoring. In most cases, a 1.2 liter separator was found to accommodate system flow conditions. This size produced reliable phase separation for liquid flow rates from 1.8 to 9.8 liters per minute, for gas flow rates of 0.5 to 180 standard liters per minute, over the full range of quality, and with fluid inventory changes up to 0.35 liters. Moreover, an acoustic sensor, integrated into the wall of the separation chamber, allows liquid film thickness monitoring with an accuracy of 0.1 inches. Currently, application of the MVS is being extended to cabin air dehumidification and a Rankine power cycle system. Both of these projects will allow further development of the TAMU separator.


Blood ◽  
1978 ◽  
Vol 51 (4) ◽  
pp. 703-709 ◽  
Author(s):  
FW Fales

Abstract Plasma urea and protein determinations proved suitable for measuring changes in total diffusible water and plasma volume in whole blood. Deoxygenation by saturation with carbon dioxide at 25 degrees C caused no change in plasma urea, but a significant increase in plasma protein concentration was induced with both normal and sickle-cell (HbSS) blood. Thus in HbSS blood there was no binding or trapping of water as a result of sickling and there was a normal influx of water into the cells (Bohr effect) despite the polymerization of the hemoglobin molecules with sickling. Consistent with this observation was the finding that the deoxygenation induced a similar increase in concentration of the plasma cations, sodium plus potassium. HbSS erythrocytes neither lost nor gained water under the more physiologic conditions of deoxygenation with a 95% nitrogen, 5% carbon dioxide gas mixture.


Author(s):  
Y.N. Wang ◽  
J.M. Pfotenhauer ◽  
X.Q. Zhi ◽  
L.M. Qiu ◽  
J.F. Li

Sign in / Sign up

Export Citation Format

Share Document