scholarly journals Marginal Fit of Temporary Restorations Fabricated by the Conventional Chairside Method, 3D Printing, and Milling

Author(s):  
Mahsa Mohajeri ◽  
Sara Khazaei ◽  
Fariborz Vafaee ◽  
Farnaz Firouz ◽  
Somayeh Ghorbani Gholiabad ◽  
...  

Objectives: This study aimed to compare the marginal fit of temporary restorations fabricated by the conventional chairside method, 3D printing, and milling. Materials and Methods: In this in vitro, experimental study, 14 temporary restorations were conventionally fabricated over an implant abutment and analog that had been mounted in a phantom model at the site of canine tooth, using auto-polymerizing acrylic resin and putty index. In digital manufacturing, the original model was scanned, and the final restoration was designed. Fourteen temporary restorations were milled out of polymethyl methacrylate (PMMA) blocks, and 14 others were printed by a 3D printer. Temporary crowns were placed on the abutment, and images were obtained from specific areas under a stereomicroscope at x100 magnification to measure the amount of marginal gap. Data were analyzed using one-way ANOVA and Tukey’s test (α=0.05). Results: The mean marginal gap values for the temporary crowns in the 3D printing, milling, and chairside groups were 91.40, 75.28 and 51.23 µm, respectively. The crowns that were conventionally fabricated chairside exhibited the lowest marginal gap, and the difference in this respect was significant among the three groups (P<0.05). Conclusion: Temporary crowns fabricated by the chairside method showed significantly smaller marginal gap; however, the marginal gap of all three groups was within the clinically acceptable range.

2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
F. D. Oz ◽  
S. Bolay

Objective. The aim of this in vitro study was to evaluate marginal adaptation and fracture strength of inlays produced by CEREC Omnicam using different types of blocs and heat-pressed technique. Methods: Seventy-five extracted human mandibular molars were divided randomly into 5 groups (n=15). 60 molars in four groups received MOD inlay preparations. Experimental groups were CO: Intact teeth, EC: IPS e.max CAD and CEREC, LU: Lava Ultimate and CEREC, EL: IPS Empress CAD and CEREC, EP: IPS Empress Esthetic ingots and heat-pressed technique. Marginal gap measurements were taken with a stereomicroscope. Restorations were cemented with Variolink N and stored in distilled water at 37°C for 24 hours. All samples were subjected to thermocycling. The fracture strength of specimens was determined at a 0.5 mm/min crosshead speed until fracture. Fracture modes were determined. Statistical analyses were performed using one-way analysis of variance for fracture strength data and Kruskal–Wallis for marginal gap data (p=0.05). Results. The mean marginal gap size of EC, LU, EL, and EP were 33.54 µm, 33.77 µm, 34.23 µm, and 85.34 µm, respectively. EP had statistically higher values than other groups. The fracture strength values were significantly higher in the intact teeth group (3959,00 ± 1279,79 N) than those of restored groups EC (2408,00 ± 607,97 N), LU (2206,73 ± 675,16), EL (2573.27 ± 644,73) ve EP (2879,53 ± 897,30). Conclusion. Inlays fabricated using CEREC Omnicam demonstrated better marginal adaptation than inlays produced with heat-pressed technique, whereas fracture strength values of inlays fabricated with different type of blocks using CEREC Omnicam exhibited similarity to those fabricated with heat-pressed technique.


Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1234
Author(s):  
António Sérgio Silva ◽  
Aurora Carvalho ◽  
Pedro Barreiros ◽  
Juliana de Sá ◽  
Carlos Aroso ◽  
...  

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.


Author(s):  
Eisha Imran ◽  
Faisal Moeen ◽  
Beenish Abbas ◽  
Bakhtawar Yaqoob ◽  
Mehreen Wajahat ◽  
...  

Abstract Objectives The study aimed to evaluate and compare various commercially available local anesthetic solutions. Materials and Methods A total of 150 commercially available local anesthetic cartridges of similar composition (2% lidocaine with epinephrine 1:100,000) were randomly collected and divided into 3 groups. The designations of groups were selected from their product names such that each group consisted of 60 cartridges. Group S (Septodont, France) Group M (Medicaine, Korea) and Group H (HD-Caine, Pakistan). The samples were divided into five sub-groups, each consisting of 10 cartridges from each group to investigate each parameter. Results The acquired data was statistically analyzed and compared (using SPSS version 12). Compositional analysis revealed a non-significant (P>0.05) difference when the three Groups were compared with standard lidocaine and epinephrine solutions. The mean pH values of samples from group S, M and H respectively fell within the range of pH values of commercially available solutions. Non-significant difference in EPT values of Group S and H was found when efficacy was compared (p = 0.3), however a significant difference (p < 0.01) was observed in contrast to Group M. Anti-bacterial activity was observed in all the group and a non-significant difference in cell viability values of Group S and M was found (p = 0.6), while the difference was significant in comparison to Group H. Conclusion Within the limitations of these investigations, it appears that the properties of different manufacturers fall within the recommended ranges as mentioned in literature and do not appear to be statistically different in the variables we have tested.


2019 ◽  
Vol 218 (9) ◽  
pp. 2841-2853 ◽  
Author(s):  
Claire Strothman ◽  
Veronica Farmer ◽  
Göker Arpağ ◽  
Nicole Rodgers ◽  
Marija Podolski ◽  
...  

Dynamic organization of microtubule minus ends is vital for the formation and maintenance of acentrosomal microtubule arrays. In vitro, both microtubule ends switch between phases of assembly and disassembly, a behavior called dynamic instability. Although minus ends grow slower, their lifetimes are similar to those of plus ends. The mechanisms underlying these distinct dynamics remain unknown. Here, we use an in vitro reconstitution approach to investigate minus-end dynamics. We find that minus-end lifetimes are not defined by the mean size of the protective GTP-tubulin cap. Rather, we conclude that the distinct tubulin off-rate is the primary determinant of the difference between plus- and minus-end dynamics. Further, our results show that the minus-end–directed kinesin-14 HSET/KIFC1 suppresses tubulin off-rate to specifically suppress minus-end catastrophe. HSET maintains its protective minus-end activity even when challenged by a known microtubule depolymerase, kinesin-13 MCAK. Our results provide novel insight into the mechanisms of minus-end dynamics, essential for our understanding of microtubule minus-end regulation in cells.


2012 ◽  
Vol 06 (02) ◽  
pp. 163-168 ◽  
Author(s):  
Gulce Subasi ◽  
Nilgun Ozturk ◽  
Inan Ozgur ◽  
Nalan Bozogullari

ABSTRACTObjectives: This in-vitro study investigated the marginal fit of two all-ceramic copings with 2 finish line designsMethods: Forty machined stainless steel molar die models with two different margin designs (chamfer and rounded shoulder) were prepared. A total of 40 standardized copings were fabricated and divided into 4 groups (n=10 for each finish line-coping material). Coping materials tested were IPS e.max Press and Zirkonzahn; luting agent was Variolink II. Marginal fit was evaluated after cementation with a stereomicroscope (Leica MZ16). Two-way analysis of variance and Tukey-HSD test were performed to assess the influence of each finish line design and ceramic type on the marginal fit of 2 all-ceramic copings (α =.05) Results: Two-way analysis of variance revealed no statistically significant differences for marginal fit relative to finish lines (P=.362) and ceramic types (P=.065)Conclusion: Within the limitations of this study, both types of all-ceramic copings demonstrated that the mean marginal fit was considered acceptable for clinical application (≤120 μm). (Eur J Dent 2012;6:163-168)


2007 ◽  
Vol 330-332 ◽  
pp. 1409-1412
Author(s):  
O.E. Puntsag ◽  
E.K. Bae ◽  
Jae Hoon Lee ◽  
Keun Woo Lee

This study evaluated the marginal fit of CAD-CAM Zirconia cores with different proximal height. Thirty Zirconia cores and ten metal ceramics crowns were used to evaluate the marginal gap. The marginal fit was determined to be perpendicular to the tooth axis between the most apical point on the coping margin (core) and the reference marks on the mesial, distal, labial, and palatal surfaces of the die at several key stages of crown fabrication; before porcelain built-up, after body porcelain built-up, and after glazing. Additionally, an opaque stage for the metal ceramic copings was compared as well. Each measurement was carried out with a microscope. The means of gaps among the groups were 58±27 -m, 69±23 -m, 89±29 -m and 80±28 -m, groups I, II, III and IV, respectively. In relation to the proximal and labiopalatal surfaces there were no statistical difference among the groups, except group I. No significant differences were observed in firing stages of all groups. The findings of this study showed that the mean marginal gap of Zirconia cores with different proximal heights fell well within the acceptable clinical ranges.


1989 ◽  
Vol 68 (9) ◽  
pp. 1308-1312 ◽  
Author(s):  
J. Li ◽  
R.P. Ellen

The study was designed to compare the adherence of several Bacteroides species to A. viscosus. Using 3H, we labeled 24 laboratory strains, including 13 Bacteroides species and I I fresh clinical isolates of three Bacteroides species. Their adherence to A. viscosus bound to a saliva-coated mineral surface was quantified by liquid scintillation. Adherence relative to a standard strain, B. gingivalis 2561, was compared. Among the lab bacteroides, those of B. gingivalis (eight strains) were the greatest binders (mean, 80.5 ± 12.4%). Strains of other lab bacteroides bound less well (mean, 33.4 ± 6.3%). The difference in means was statistically significant (p<0.01). The mean for B. gingivalis strains was also significantly greater than that for strains of B. intermedius (51.7 ± 6.2%). Attachment of B . gingivalis was saturable in experiments in which either input concentration or time was the independent variable, indicating that B. gingivalis cells do not accumulate in this in vitro simulation of plaque formation by binding to each other. Subculture did not seem to affect the degree of binding.


Author(s):  
Larissa Gomes ◽  
Renata Almeida-Pedrin ◽  
Victor Ladewig ◽  
Victor Didier ◽  
Joel Santiago ◽  
...  

O objetivo deste estudo consistiu em comparar a degradação de força de cinco cores diferentes de elásticos corrente, a fim de buscar parâmetros clínicos para o uso desses elásticos nas terapias ortodônticas. Foram avaliados 10 segmentos com 6 elos de elásticos corrente de força média da marca Morelli, das cores preto, cinza, azul, rosa e transparente, provenientes de embalagens seladas e dentro do prazo de validade. Os elásticos foram distendidos até o dobro de seu comprimento e mantidos por dispositivos simples com duas pontas de metal, simulando o uso contínuo dos elásticos por parte dos pacientes. Esses dispositivos foram submersos em saliva artificial a 370C dentro de recipientes mantidos em estufa.  As forças dos segmentos de elásticos foram mensuradas com um dinamômetro ortodôntico de precisão ao início e nos intervalos de 1, 7,14, 21 e 30 dias após a imersão, e a média de força para cada grupo e tempo foi calculada. A Análise de variância (ANOVA) a dois critérios (tempo e grupos) e o teste de Tukey foram utilizados para a análise dos dados. Em todos os testes estatísticos foi adotado um nível de significância de 5%. Todas as cores de elásticos degradaram com o tempo, sendo a porcentagem média de degradação após 1 dia de 40,4%; 7 dias 48,2%; 14 dias 56,8%; 21 dias 65% e 81% após 30 dias. Entretanto, há diferença de degradação de força entre as cores dos elásticos. Os elásticos Transparente e Azul apresentaram menor degradação da força, sendo que após 30 dias o elástico Transparente se mostrou mais efetivo, seguido do Azul, Cinza, Preto e Rosa. Mesmo com a diferença na degradação de força entre as cores dos elásticos, esses dados não apresentam relevância clínica se utilizados por até 14 dias, após esse período seria melhor a utilização do elástico Transparente.   Palavras-chave: Ortodontia. Látex. Elasticidade   Abstract The aim of this study was to compare the force degradation of five different colors of elastomeric chains, in order to achieve clinical parameters for the use of these elastics in orthodontic therapies. The sample was composed by 10 segments with 6 links (medium force) for each color of elastomeric chain (Morelli); black, gray, blue, pink and transparent, from sealed packages and within the expiration date. The elastics were stretched twice their length and maintained by simple devices with two metal tips, simulating the continuous use of the elastics by the patients. These devices were submerged in artificial saliva at 370C to simulate the oral environment. The  elastic segments strengths were measured with a precision orthodontic dynamometer at the beginning and at intervals of 1, 7, 14, 21 and 30 days after immersion, and the mean strength for each group and time was calculated. Analysis of variance (ANOVA) with two criteria (time and groups) and the Tukey test were used for data analysis. In all statistical tests, a significance level of 5% was adopted. All the  elastics colors degraded over time, with the average  degradation percentage after 1 day being 40.4%; 7 days 48.2%; 14 days 56.8%; 21 days 65% and 81% after 30 days. However, there is a difference in force degradation among the  elastics colors. The Transparent and Blue elastics showed less force degradation, and after 30 days the Transparent elastic was more effective, followed by Blue, Gray, Black and Pink. Even with the difference in force degradation among the  elastics colors, these data are not clinically relevant they are used for up to 14 days, after that period it would be better to use the Transparent elastic.   Keywords: Orthodontics. Latex. Elasticity


2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Rhoodie Garrana ◽  
Govindrau Mohangi ◽  
Paulo Malo ◽  
Miguel Nobre

Background. Endotoxin initiates osteoclastic activity resulting in bone loss. Endotoxin leakage through implant abutment connections negatively influences peri-implant bone levels.Objectives. (i) To determine if endotoxin can traverse different implant-abutment connection (IAC) designs; (ii) to quantify the amount of endotoxins traversing the IAC; (iii) to compare the in vitro comportments of different IACs.Materials and Methods. Twenty-seven IACs were inoculated withE. coliendotoxin. Six of the twenty-seven IACs were external connections from one system (Southern Implants) and the remaining twenty-one IACs were made up of seven internal IAC types from four different implant companies (Straumann, Ankylos, and Neodent, Southern Implants).Results. Of the 27 IACs tested, all 6 external IACs leaked measurable amounts of endotoxin. Of the remaining 21 internal IACs, 9 IACs did not show measurable leakage whilst the remaining 12 IACs leaked varying amounts. The mean log endotoxin level was significantly higher for the external compared to internal types (p=0.015).Conclusion. Within the parameters of this study, we can conclude that endotoxin leakage is dependent on the design of the IAC. Straumann Synocta, Straumann Cross-fit, and Ankylos displayed the best performances of all IACs tested with undetectable leakage after 7 days. Each of these IACs incorporated a morse-like component in their design. Speculation still exists over the impact of IAC endotoxin leakage on peri-implant tissues in vivo; hence, further investigations are required to further explore this.


1987 ◽  
Vol 57 (2) ◽  
pp. 223-233 ◽  
Author(s):  
T. Hazell ◽  
I. T. Johnson

1. Plant foods were digested in vitro and the proportion of iron which diffused across a ssemi-permeable membrane was used as an index of Fe availability.2. The mean (with SEM) Fe diffusibility from a group of eighteen cereals, legumes and nuts was very low, 2.1 (0.25)%, whereas from a group of sixteen fruits and vegetables it was high, 13.7 (1.09)%. The difference between the two food groups was highly significant (P< 0.001).3. The results for Fe diffusibility correlated well with literature values for the in vivo absorption of Fe from similar foods (r0.84,P< 0.01).4. When phytate, citrate and ascorbate were added to selected foods in amounts corresponding to endogenous levels, only phytate and citrate gave the expected effects on Fe diffusibility. Ascorbate only enhanced Fe diffusibility to the expected extent when it was added in much larger amounts, not normally found in foods.5. When added to cereal foods, orange juice was found to enhance greatly Fe diffusibility even when its content of ascorbate was completely destroyed by boiling followed by prolonged storage. When citrate and ascorbate were added to cereal foods in amounts equivalent to those found in fresh orange juice, both enhanced Fe diffusibility but citrate was far more effective.6. It is concluded that phytate is a major inhibitor of Fe diffusibility in cereals, legumes and nuts. However, citrate rather than ascorbate would appear to be the major enhancer of Fe diffusibility from many fruits and vegetables.7. The implications of the present results are discussed in relation to the relative influence of phytate, citrate and ascorbate on dietary Fe availability.


Sign in / Sign up

Export Citation Format

Share Document