scholarly journals Inter-rater reliability of an exercise adherence measurement tool: Measurement Of adherence Via Exercise Demonstration (MOVED)

Author(s):  
Kerry Peek

Objective: To explore the inter-rater reliability of the Measurement Of adherence Via Exercise Demonstration (MOVED) adherence tool. Design: Reliability study of a patient adherence measurement tool.Setting: Simulated physiotherapist-patient consultations. Participants: Sixteen experienced physiotherapists rated patient adherence to exercise. Interventions: N/A Main Outcome Measure: Inter-rater reliability of MOVED.Methods: The MOVED tool consists of two parts. Part one asks patients to self-report their adherence to exercise dose (including number of completed sessions, sets and repetitions in the last seven days). Part two asks patients to demonstrate each exercise. Component scores are totalled to give an overall level of patient adherence to each exercise.Participants were provided with a copy of five physiotherapist-prescribed exercises. Participants were then shown five corresponding video vignettes of simulated physiotherapist-patient consultations where patients were asked to self-report exercise frequency, sets and repetitions and demonstrate each exercise within the context of a consultation. Participants were asked to rate the level of patient adherence to each of the five exercises using the MOVED tool. Inter-rater reliability of MOVED scores was assessed using Intraclass Correlation Coefficient (ICC) and 95% Confidence Intervals. Results: The ICC of part one (self-report) was .90 (95%CI .74-.98), part two (demonstration) was .98 (95%CI .94-.99) and total score was .96 (95%CI .88-.99), demonstrating excellent inter-rater reliability. Conclusion: The MOVED tool, which can highlight whether patients are adhering to exercise technique as well as exercise dose, may provide clinicians and researchers with a more robust measure of exercise adherence when compared with other measures currently available.

2013 ◽  
Vol 10 (4) ◽  
pp. 607-613 ◽  
Author(s):  
Karyn Tappe ◽  
Ellen Tarves ◽  
Jayme Oltarzewski ◽  
Deirdra Frum

Background:Predictive modeling for physical activity behavior has included many different psychological components, including planning, motivation, personality, and self-efficacy. However, habit formation in exercise maintenance has not been well explored and lacks reliable measurement tools. The current study explores novel survey questions that examine behavioral components of exercise habit, including frequency, environmental cuing, and temporal constancy of behavior. We then relate these concepts to an established psychological measure of habit, the Self-Report Habit Inventory (SRHI).Methods:One hundred and seventy-four exercisers were surveyed at 2 private fitness clubs. A single questionnaire was administered that included the SRHI and the novel behavioral questions developed from habit formation concepts.Results:Habit formation was reported by many of the exercisers. Participants scoring higher on the SRHI also reported higher frequency of physical activity and a higher probability of environmental cuing. Exercise frequency did not correlate well with environmental cuing.Conclusions:Habit formation appears relevant to the physical activity patterns of many regular exercisers. However, wide variation in response styles was evident suggesting further development and exploration of the novel questionnaire is warranted. The ultimate goals are to include habit in predictive models of physical activity, and then to inform interventions to increase exercise adherence.


2019 ◽  
Vol 22 (5) ◽  
pp. e25304 ◽  
Author(s):  
Rachel C Vreeman ◽  
Michael L Scanlon ◽  
Wanzhu Tu ◽  
James E Slaven ◽  
Carole I McAteer ◽  
...  

Author(s):  
Lisa Jasper ◽  
Lauren A. Beaupre ◽  
John C. Spence ◽  
C. Allyson Jones

Few validated tools exist for measuring physical activity following total knee arthroplasty (TKA) despite the importance of returning to sufficient levels of physical activity post-TKA to achieve health benefits. This study examined the validity of two clinical measures—the Fitbit, a commercially available personal activity monitor, and the Community Healthy Activities Model Program for Seniors (CHAMPS), a self-report questionnaire—compared with a reference standard accelerometer, the SenseWearTM Armband (SWA). At 6-month post-TKA, 47 participants wore the Fitbit and SWA for 4 days and then completed the CHAMPS. Moderate-to-good correlation was observed between the Fitbit and SWA for steps (intraclass correlation coefficient [ICC] = .79), energy expenditure (ICC = .78), and energy expenditure <3 METS (ICC = .79). Poor-to-moderate correlation was observed between the CHAMPS and SWA (ICC = .43) with the questionnaire reporting lower daily energy expenditures than the SWA. Results showed that Fitbit may be a reasonable measurement tool to measure steps and energy expenditures in older adults following TKA.


Author(s):  
Blanca De-la-Cruz-Torres ◽  
Emmanuel Navarro-Flores ◽  
Daniel López-López ◽  
Carlos Romero-Morales

Background: the aim of this study was to compare the echotexture of patients with soleus muscle injury and age matched controls. Methods: a sample of 62 athletes was recruited at the private clinic and was divided in two group: a healthy group (n = 31) and a soleus pathology group whose athletes had soleus muscle injury, located in the central tendon (n = 31). The muscle thickness (MTh), echointensity (EI) and echovariation (EV) were analyzed. An intra-rater reliability test (Intraclass Correlation Coefficient-ICC) was performed in order to analyze the reliability of the values of the measurements. Results: Sociodemographic variables did not show statistically significant differences (p > 0.05). Ultrasound imaging measurements who reported statistically significant differences were EI (p = 0.001) and standard deviation (SD) (p = 0.001). MTh and EV variables did not show statistically significant differences (p = 0.381 and p = 0.364, respectively). Moreover, reliability values for the MTh (ICC = 0.911), EI (ICC = 0.982), SD (ICC = 0.955) and EV (ICC = 0.963). Based on these results the intra-rater reliability was considered excellent. Conclusion: Athletes with a central tendon injury of soleus muscle showed a lower EI when they were compared to healthy athletes. The echogenicity showed by the quantitative ultrasound imaging measurement may be a more objective parameter for the diagnosis and follow-up the soleus muscle injuries.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Nora Bakaa ◽  
Lu Hsi Chen ◽  
Lisa Carlesso ◽  
Julie Richardson ◽  
Luciana Macedo

Abstract Objective The aim of this study was to evaluate the completeness of reporting of exercise adherence and exercise interventions delivered as part of clinical trials of post-operative total knee replacement (TKA) rehabilitation. Design: Scoping review Literature search A literature search was conducted in PubMed, EMBASE, AMED, CINAHL, SPORTDiscus and Cochrane Library. Study selection criteria All randomized controlled trials (RCT) that examined post-operative exercise-based interventions for total knee arthroplasty were eligible for inclusion. Studies that were multifactorial or contained exercise interventions for both hip and knee arthroplasty were also included. Data synthesis The definition, type of measurement used and outcome for exercise adherence were collected and analyzed descreptively. Quality of reporting of exercise interventions were assessed using the Consensus for Exercise Reporting Tool (CERT) and the Cochrane Risk of Bias Tool. Results There were a total of 112 RCTs included in this review. The majority of RCTs (63%, n = 71) did not report exercise adherence. Only 23% (n = 15) of studies provided a definition of adherence. RCTs were of poor quality, with 85% (n = 95) of studies having high or unclear risk of bias. Reporting of exercise interventions was poor, with only 4 items (of 19) (21%) of the CERT adequately reported (88–99%), with other items not fulfilled on at least 60% of the RCTs. There were no RCTs that had fulfilled all the criteria for the CERT. Conclusion The RCTs included in this study poorly reported exercise adherence, as well as description of the post-operative TKA rehabilitation intervention. Future RCTs should use valid and reliable measures of adherence and a proper tool for reporting of exercise interventions (e.g., CERT, TiDER). Pre-registration OSF:https://osf.io/9ku8a/


Author(s):  
Aida Carballo-Fazanes ◽  
Ezequiel Rey ◽  
Nadia C. Valentini ◽  
José E. Rodríguez-Fernández ◽  
Cristina Varela-Casal ◽  
...  

The Test of Gross Motor Development (TGMD) is one of the most common tools for assessing the fundamental movement skills (FMS) in children between 3 and 10 years. This study aimed to examine the intra-rater and inter-rater reliability of the TGMD—3rd Edition (TGMD-3) between expert and novice raters using live and video assessment. Five raters [2 experts and 3 novices (one of them BSc in Physical Education and Sport Science)] assessed and scored the performance of the TGMD-3 of 25 healthy children [Female: 60%; mean (standard deviation) age 9.16 (1.31)]. Schoolchildren were attending at one public elementary school during the academic year 2019–2020 from Santiago de Compostela (Spain). Raters scored each children performance through two viewing moods (live and slow-motion). The ICC (Intraclass Correlation Coefficient) was used to determine the agreement between raters. Our results showed moderate-to-excellent intra-rater reliability for overall score and locomotor and ball skills subscales; moderate-to-good inter-rater reliability for overall and ball skills; and poor-to-good for locomotor subscale. Higher intra-rater reliability was achieved by the expert raters and novice rater with physical education background compared to novice raters. However, the inter-rater reliability was more variable in all the raters regardless of their experience or background. No significant differences in reliability were found when comparing live and video assessments. For clinical practice, it would be recommended that raters reach an agreement before the assessment to avoid subjective interpretations that might distort the results.


2015 ◽  
Vol 24 (2) ◽  
pp. 164-176 ◽  
Author(s):  
Eva van Leer ◽  
Nadine P. Connor

PurposePatient adherence to voice therapy is an established challenge. The purpose of this study was (a) to examine whether adherence to treatment could be predicted from three social–cognitive factors measured at treatment onset: self-efficacy, goal commitment, and the therapeutic alliance, and (b) to test whether the provision of clinician, self-, and peer model mobile treatment videos on MP4 players would influence the same triad of social cognitive factors and the adherence behavior of patients.MethodForty adults with adducted hyperfunction with and without benign lesions were prospectively randomized to either 4 sessions of voice therapy enhanced by MP4 support or without MP4 support. Adherence between sessions was assessed through self-report. Social cognitive factors and voice outcomes were assessed at the beginning and end of therapy. Utility of MP4 support was assessed via interviews.ResultsSelf-efficacy and the therapeutic alliance predicted a significant amount of adherence variance. MP4 support significantly increased generalization, self-efficacy for generalization, and the therapeutic alliance. An interaction effect demonstrated that MP4 support was particularly effective for patients who started therapy with poor self-efficacy for generalization.ConclusionAdherence may be predicted and influenced via social–cognitive means. Mobile technology can extend therapy to extraclinical settings.


Author(s):  
Henriëtte A. W. Meijer ◽  
Maurits Graafland ◽  
Miryam C. Obdeijn ◽  
Marlies P. Schijven ◽  
J. Carel Goslings

Abstract Purpose To determine the validity of wrist range of motion (ROM) measurements by the wearable-controlled ReValidate! wrist-rehabilitation game, which simultaneously acts as a digital goniometer. Furthermore, to establish the reliability of the game by contrasting ROM measurements to those found by medical experts using a universal goniometer. Methods As the universal goniometer is considered the reference standard, inter-rater reliability between surgeons was first determined. Internal validity of the game ROM measurements was determined in a test–retest setting with healthy volunteers. The reliability of the game was tested in 34 patients with a restricted range of motion, in whom the ROM was measured by experts as well as digitally. Intraclass-correlation coefficients (ICCs) were determined and outcomes were analyzed using Bland–Altman plots. Results Inter-rater reliability between experts using a universal goniometer was poor, with ICCs of 0.002, 0.160 and 0.520. Internal validity testing of the game found ICCs of − 0.693, 0.376 and 0.863, thus ranging from poor to good. Reliability testing of the game compared to medical expert measurements, found that mean differences were small for the flexion–extension arc and the radial deviation-ulnar deviation arc. Conclusion The ReValidate! game is a reliable home-monitoring device digitally measuring ROM in the wrist. Interestingly, the test–retest reliability of the serious game was found to be considerably higher than the inter-rater reliability of the reference standard, being healthcare professionals using a universal goniometer. Trial registration number (internal hospital registration only) MEC-AMC W17_003 #17.015.


2021 ◽  
Vol 11 (9) ◽  
pp. 3947
Author(s):  
Marco Farronato ◽  
Gianluca M. Tartaglia ◽  
Cinzia Maspero ◽  
Luigi M. Gallo ◽  
Vera Colombo

Clinical use of portable optical tracking system in dentistry could improve the analysis of mandibular movements for diagnostic and therapeutic purposes. A new workflow for the acquisition of mandibular kinematics was developed. Reproducibility of measurements was tested in vitro and intra- and inter-rater repeatability were assessed in vivo in healthy volunteers. Prescribed repeated movements (n = 10) in three perpendicular directions of the tracking-device coordinate system were performed. Measurement error and coefficient of variation (CV) among repetitions were determined. Mandibular kinematics of maximum opening, left and right laterality, protrusion and retrusion of five healthy subjects were recorded in separate sessions by three different operators. Obtained records were blindly examined by three observers. Intraclass correlation coefficient (ICC) was calculated to estimate inter-rater and intra-rater reliability. Maximum in vitro measurement error was 0.54 mm and CV = 0.02. Overall, excellent intra-rater reliability (ICC > 0.90) for each variable, general excellent intra-rater reliability (ICC = 1.00) for all variables, and good reliability (ICC > 0.75) for inter-rater tests were obtained. A lower score was obtained for retrusion with “moderate reliability” (ICC = 0.557) in the inter-rater tests. Excellent repeatability and reliability in optical tracking of primary movements were observed using the tested portable tracking device and the developed workflow.


2021 ◽  
Author(s):  
Yoon-Soo Seo ◽  
Ki-Hun Jo ◽  
Jun-Sang CHA ◽  
Joo-Yeon Kim ◽  
Jae-Hwan Kwon

Abstract Background: This study investigates and compare the reliability and reproducibility of two facial anthropometric methods about external nasal angles, 3D imaging and conventional 2D photography. Methods: 2D photograph images and 3D images about external nose of 30 volunteers were taken using digital camera and Morpheus 3D scanner. To evaluate intra-rater reliability, each images were taken over two different days for each subject by the same researcher. To evaluate inter-rater reliability, another researcher took each images for each subject on the first day. The reliability of each method for measuring 4 external nasal angle is obtained using intraclass correlation coefficient (ICC) and compared.Results: Inter-rater and intra-rater reliability of both 3D imaging and 2D photography had excellent agreement in all 4 nasal angles. In the nasofacial angular parameter, Inter-rater ICC, 2D photography was significantly higher than 3D imaging. Result of intra-rater ICC also showed both 3D imaging and 2D photography had good reliability in all 4 nasal angles. Similar to those of inter-rater ICC, nasofacial angular parameter showed statistically significant differences between 3D imaging and 2D photography.Conclusion: In terms of reliability, both 2D and 3D showed appropriate anthropometric results and considering its own advantage, each methods can be used complementarily.


Sign in / Sign up

Export Citation Format

Share Document