scholarly journals ADAPTIVE HOUSE DESIGN AND PEOPLE’S HABITS IN ACHIEVING THERMAL COMFORT IN GAYO HIGHLAND ACEH, INDONESIA

2021 ◽  
Vol 8 (1) ◽  
pp. 23
Author(s):  
Erna Meutia ◽  
Laina Hilma Sari

The Gayo Highland is one of the districts in Aceh Province, Sumatra. Due to the topography, this area has a lower  temperature compared than the flat and coastal areas in Aceh. The thermal comfort that is felt is based on a person's mental condition and how he expresses his satisfaction with his thermal environment. In other words, it shows how humans adapt to their thermal environment. Thermal comfort based on human adaptation is known as adaptive thermal comfort. The form of dwelling for the Gayo Highland community has shifted and changed from traditional dwelling to Transitional and Modern forms that influence the Gayo Highland community's adaptation to achieve thermal comfort. Therefore, this paper aims to investigate the house design in Gayo highland in providing warmth to the occupants naturally in the cold environment. Another aim of this study is to investigate the people's habits in warming up the body to deal with the low air temperature in the area.  This study shows how the local people adapt themselves through the house element and daily habit to gain the internal thermal comfort.

Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 696
Author(s):  
Eun Ji Choi ◽  
Jin Woo Moon ◽  
Ji-hoon Han ◽  
Yongseok Yoo

The type of occupant activities is a significantly important factor to determine indoor thermal comfort; thus, an accurate method to estimate occupant activity needs to be developed. The purpose of this study was to develop a deep neural network (DNN) model for estimating the joint location of diverse human activities, which will be used to provide a comfortable thermal environment. The DNN model was trained with images to estimate 14 joints of a person performing 10 common indoor activities. The DNN contained numerous shortcut connections for efficient training and had two stages of sequential and parallel layers for accurate joint localization. Estimation accuracy was quantified using the mean squared error (MSE) for the estimated joints and the percentage of correct parts (PCP) for the body parts. The results show that the joint MSEs for the head and neck were lowest, and the PCP was highest for the torso. The PCP for individual activities ranged from 0.71 to 0.92, while typing and standing in a relaxed manner were the activities with the highest PCP. Estimation accuracy was higher for relatively still activities and lower for activities involving wide-ranging arm or leg motion. This study thus highlights the potential for the accurate estimation of occupant indoor activities by proposing a novel DNN model. This approach holds significant promise for finding the actual type of occupant activities and for use in target indoor applications related to thermal comfort in buildings.


2021 ◽  
Vol 13 (7) ◽  
pp. 3614
Author(s):  
Zeyad Amin Al-Absi ◽  
Mohd Isa Mohd Hafizal ◽  
Mazran Ismail ◽  
Azhar Ghazali

Building sector is associated with high energy consumption and greenhouse gas emissions, which contribute to climate change. Sustainable development emphasizes any actions to reduce climate change and its effect. In Malaysia, half of the energy utilized in buildings goes towards building cooling. Thermal comfort studies and adaptive thermal comfort models reflect the high comfort temperatures for Malaysians in naturally conditioned buildings, which make it possible to tackle the difference between buildings’ indoor temperature and the required comfort temperature by using proper passive measures. This study investigates the effectiveness of building’s retrofitting with phase change materials (PCMs) as a passive cooling technology to improve the indoor thermal environment for more comfortable conditions. PCM sheets were numerically investigated below the internal finishing of the walls. The investigation involved an optimization study for the PCMs transition temperatures and quantities. The results showed significant improvement in the indoor thermal environment, especially when using lower transition temperatures and higher quantities of PCMs. Therefore, the monthly thermal discomfort time has decreased completely, while the thermal comfort time has increased to as high as 98%. The PCM was effective year-round and the optimum performance for the investigated conditions was achieved when using 18mm layer of PCM27-26.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


1987 ◽  
Vol 1 (2) ◽  
pp. 74-77 ◽  
Author(s):  
S C Foo ◽  
WO Phoon

Two hundred and eighty-five Office workers were surveyed and the micro-climatic conditions in which they worked were measured to evaluate their preferred temperature. About 78% of workers considered the natural tropical climate uncomfortable. However, 76% to 87% of workers in airconditioned Offices approved of their thermal environment if its temperature ranged from 21°C to 27°C. Many workers who felt that the temperature produced a neutral thermal sensation in the body as a whole, tended to complain that their heads were too warm and at the same time their limbs too cool. About 60% of workers in airconditioned Offices were exposed to an air temperature of less than 24°C. Present data suggest that an air temperature of 27°C would be comfortable for more than 80% of workers.


2020 ◽  
Vol 4 (3) ◽  
pp. 261
Author(s):  
Abdul Qodir ◽  
Erni Setyowati ◽  
Suryono Suryono

This study examines the effect of the porch on the adaptive thermal comfort of mosques by taking 2 mosques that have different porch shapes with the specific purpose of obtaining data on the neutrality, acceptability and preferences of the mosque respondents' thermal conditions in the framework of developing adaptive thermal comfort standards for Indonesia. Measurement of physical environment variables is done by taking data on temperature, humidity, air velocity, and mean radiant temperature (MRT) at 2 mosques and at the same time the impression and thermal preference questionnaire data are taken, examination of clothing types and activities, and list of thermal environment controls to 40 respondents in each mosque. Data of thermal neutrality and thermal preferences were analyzed by regression analysis using SPSS 19 software, while thermal acceptance was analyzed based on the results of the questionnaire answers. The analysis showed that the neutrality value at Ulul Albab mosque was Tdb = 28.47 OC, ET * = 30.11 OC, SET * = 23.11 OC, TSENS = 1.17, DISC = -1.06, and PMV = -0.65, this data shows that the neutral condition desired by respondents is slightly below the average condition, while the neutrality in Nurul Ilmi mosque at Tdb = 30.27 OC, ET * = 31.65 OC, SET * = 29.05 OC, TSENS = 1.03, DISC = 1.68, and PMV = 1.22, this data also shows that the neutral conditions desired by respondents are slightly below average conditions. While the preference value at Ulul Albab mosque is Tdb = 22.25 OC, ET * = 28.62 OC, SET * = 24.24 OC, TSENS = 0.23, DISC = 0.23, and PMV = -0.60 and preference conditions at Nurul Ilmi mosque at Tdb = 29.11 OC, ET * = 31.17 OC, SET * = 28.50 OC, TSENS = 1.04, DISC = 1.45, and PMV = 1.03. As many as 92% of respondents in the Ulul Albab mosque can accept local thermal conditions in the temperature range of 27oC - 31oC. While 90% of respondents in the Nurul Ilmi mosque can accept local thermal conditions in the temperature range of 27oC-32oC. The results of the neutrality, acceptance and preference analysis show that the Ulul Albab mosque is better than the Nurul Ilmi mosque.


Buildings ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 551
Author(s):  
Zoubayre El Akili ◽  
Youcef Bouzidi ◽  
Abdelatif Merabtine ◽  
Guillaume Polidori ◽  
Amal Chkeir

The thermal comfort requirements of disabled people in healthcare buildings are an important research topic that concerns a specific population with medical conditions impacted by the indoor environment. This paper experimentally investigated adaptive thermal comfort in buildings belonging to the Association of Parents of Disabled Children, located in the city of Troyes, France, during the winter season. Thermal comfort was evaluated using subjective measurements and objective physical parameters. The thermal sensations of respondents were determined by questionnaires adapted to their disability. Indoor environmental parameters such as relative humidity, mean radiant temperature, air temperature, and air velocity were measured using a thermal microclimate station during winter in February and March 2020. The main results indicated a strong correlation between operative temperature, predicted mean vote, and adaptive predicted mean vote, with the adaptive temperature estimated at around 21.65 °C. These findings highlighted the need to propose an adaptive thermal comfort strategy. Thus, a new adaptive model of the predicted mean vote was proposed and discussed, with a focus on the relationship between patient sensations and the thermal environment.


2020 ◽  
Vol 194 ◽  
pp. 05013
Author(s):  
Xiaowei Hong ◽  
Guangjin Zhang ◽  
Yufeng Zhang

Indoor thermal environment of Hui style traditional houses is depended on surrounding environments, building layouts and envelope. Quantitative analysis of the effects of building layouts and envelope on indoor thermal environment is of great significance for preventions of traditional houses and design of new archaized houses. A field investigation was conducted on thirty-six traditional houses from nine villages in Wuyuan, and the typical buildings’ layout and envelope were determined. Four traditional buildings in different location in Wuyuan were selected for continual recording. The four buildings with four types of building layouts and envelope were analyzed by using local adaptive thermal comfort model, and the effects of building layouts and envelope of traditional buildings were clearly revealed. The most crucial way to improve indoor thermal environment in Hui style traditional buildings was raising the indoor air temperature.


Buildings ◽  
2018 ◽  
Vol 9 (1) ◽  
pp. 4 ◽  
Author(s):  
Rajan KC ◽  
Hom Rijal ◽  
Masanori Shukuya ◽  
Kazui Yoshida

A home energy management system (HEMS) shows the energy used indoors so that the energy waste can be easily identified and reduced. Thermal comfort is related to the trend of energy use in buildings. We conducted a survey in a condominium equipped with a HEMS to determine the indoor thermal environment and various behaviors of the occupants taken for thermal comfort adjustment. The results showed that there is a large variation of indoor air temperatures according to season, floor and flat. We categorized families into two groups, one with higher and the other with lower average indoor temperatures. The indoor air temperature of the higher temperature group in summer was found to be higher than the recommended indoor temperature during the summer season in Japan. The higher temperature group tended to adopt behaviors, such as window opening and using a fan more often, than the lower temperature group. Due to the moderately high insulating levels in the building surveyed, the indoor air temperature of both groups was not low in winter. Heating was used less and irregular. The overall results indicate that the groups of families behaved differently to adjust the indoor thermal environment even though they were equipped with the same HEMS system.


2019 ◽  
Vol 15 (2) ◽  
pp. 14-25
Author(s):  
Hom B. Rijal ◽  
Michael A. Humphreys ◽  
J. Fergus Nicol

Office workers use a variety of adaptive opportunities to regulate their indoor thermal environment. The behavioural adaptations such as window opening, clothing adjustments, and use of heating/cooling are important factors for adaptive thermal comfort. It is well-known that they are the most important contributors in the adaptive thermal comfort model. Thus, if we understand the behavioural adaptation properly, we can explain the mechanism of the adaptive model. The indoor thermal environment is often adjusted using the air conditioning in Japanese office buildings to improve thermal comfort and productivity. Thus, it is necessary to conduct research on the behavioural adaptation in the offices because the occupant behavior is different from behaviour in dwellings. In order to record the seasonal differences in behavioural adaptation and to develop an adaptive algorithm for Japanese offices, we measured temperatures in 11 office buildings and conducted the thermal comfort and occupant behaviour survey for over a year. We collected 4,660 samples from about 1,350 people. The proportion of ‘open window’ in the free running mode (neither heating nor cooling being used) is significantly higher than that of the air conditioned mode. The behavioural adaptation is related to the outdoor air temperature. The behavioural adaptations such as window-opening, heating and cooling use predicted by regression analysis are in good agreement with the measured data. These findings can be applied to building thermal simulation to predict the behavioural adaptation and energy use in office buildings.


2021 ◽  
Vol 881 (1) ◽  
pp. 012029
Author(s):  
H Handri ◽  
L H Sari ◽  
A Munir ◽  
A Ariatsyah

Abstract Pesisir Selatan is one of the districts in West Sumatra with a humid tropical climate with temperatures reaching 32°C during the day. The majority of coastal communities work as fishermen and build houses on the beach, such as in fishermen’s housing in South Painan. In this area there are two models of fisherman housing, namely government-assisted fisherman housing and fisherman’s original housing. Housing on the beachfront will be faced with quite extreme climatic conditions such as air velocity, air temperature, and air humidity which are relatively high on average. Therefore, it is necessary to evaluate the level of thermal comfort in the space in both models of fisherman housing to determine the performance of each fisherman’s housing in dealing with the climate. This study uses a quantitative approach by measuring the parameters of thermal comfort, namely air temperature, humidity and air velocity using a thermohygrometer and anemometer. The data collection method uses descriptive quantitative. Comfort level is evaluated based on the Indonesian national standard (SNI 03-6572-2001) and adaptive thermal comfort. Based on the results of the study, the level of thermal comfort in both models of fisherman housing is classified as uncomfortable according to SNI 03-6572-2001 and adaptive thermal comfort.


Sign in / Sign up