scholarly journals Development of a Simulation Model for Controlling and Improving the Productivity of Batch Reactors

2013 ◽  
Vol 15 (1) ◽  
pp. 78-87 ◽  
Author(s):  
Ghania Henini ◽  
Fatiha Souahi ◽  
Ykhlef Laidani

This paper describes the development of a dynamic simulator model for a jacketed batch reactor equipped with a mono-fluid heating/cooling system. The Mono-fluid flows at constant flow-rate through the jacketed reactor. The heating and cooling are assured respectively by electrical resistance and two plate heat exchangers. A detailed description of the equations leading to the development of simulation model is presented. The model is based on writing the equations of the mass balance and the heat balance for the reactor and the thermal loop in unsteady state. To validate the simulation model, we first studied the thermal behavior of the reaction mixture during heating and cooling, using water as the reaction mixture. We then considered the consecutive chemical reaction of the synthesis of cyclopentanediol from cyclopentadiene by studying the yield of this reaction. The results show that heating the reaction mixture increases significantly the yield of this synthesis reaction.

2012 ◽  
Vol 2012 ◽  
pp. 1-10
Author(s):  
Ghania Henini ◽  
Fatiha Souahi ◽  
Ykhlef Laidani

We present the thermal behavior of a batch reactor to jacket equipped with a monofluid heating/cooling system. Heating and cooling are provided respectively by an electrical resistance and two plate heat exchangers. The control of the temperature of the reaction is based on the supervision system. This strategy of management of the thermal devices is based on the usage of the thermal flux as manipulated variable. The modulation of the monofluid temperature by acting on the heating power or on the opening degrees of an air-to-open valve that delivers the monofluid to heat exchanger. The study shows that the application of this method for the conduct of the pilot reactor gives good results in simulation and that taking into account the dynamics of the various apparatuses greatly improves ride quality of conduct. In addition thermal control of an exothermic reaction (mononitration) shows that the consideration of heat generated in the model representation improve the results by elimination any overshooting of the set-point temperature.


2013 ◽  
Vol 19 (4) ◽  
pp. 573-582 ◽  
Author(s):  
Simon Stampar ◽  
Sasa Sokolic ◽  
Gorazd Karer

These days, in times of recession, we are forced by competitiveness and the optimization of production to lower the costs of the temperature control in pharmaceutical batch reactors and increase the quantity and quality of the produced pharmaceutical product (active pharmaceutical substances). Therefore, a control algorithm is needed which provides us rapid and precise temperature control. This paper deals with the development of a control algorithm, where two predictive functional controllers are connected in a cascade for heating and cooling the content of the hybrid batch reactor. The algorithm has to be designed to cope with the constraints and the mixed discrete and continuous nature of the process of heating and cooling. The main goal of the control law is to achieve rapid and exact tracking of the reference temperature, good disturbance rejection and, in particular, a small number of heating and cooling medium switchings. The simulation results of the proposed algorithm give us much better performance compared to a conventional cascade PI algorithm.


2014 ◽  
Vol 472 ◽  
pp. 348-352
Author(s):  
He Chang ◽  
Xiu Min Yu ◽  
Jing Hua Lv ◽  
Ming Zhou ◽  
Ge Li

Cooling module simulation for vehicle has been built according to the heat balance test, and the simulation results are compared with the test data to verify the authenticity of the module. This simulation model provides an effective platform for vehicle thermal management analysis. Module is used to simulate the air conditioning running and to find how different ambient temperaturesto effect the performance of the cooling module. The air conditioning working and ambience temperaturewhichis significantly influence the performance of the cooling system.


2016 ◽  
Vol 20 (4) ◽  
pp. 1121-1133 ◽  
Author(s):  
Annamaria Buonomano ◽  
Francesco Calise ◽  
Maria Vicidomini

In this paper a new simulation model of a novel solar heating and cooling system based on innovative high temperature flat plate evacuated solar thermal collector is presented. The system configuration includes: flat-plate evacuated solar collectors, a double-stage LiBr-H2O absorption chiller, gas-fired auxiliary heater, a closed loop cooling tower, pumps, heat exchangers, storage tanks, valves, mixers and controllers. The novelty of this study lies in the utilization of flat-plate stationary solar collectors, manufactured by TVP Solar, rather than concentrating ones (typically adopted for driving double-stage absorption chillers). Such devices show ultra-high thermal efficiencies, even at very high (about 200?C) operating temperatures, thanks to the high vacuum insulation. Aim of the paper is to analyse the energy and economic feasibility of such novel technology, by including it in a prototypal solar heating and cooling system. For this purpose, the solar heating and cooling system design and performance were analysed by means of a purposely developed dynamic simulation model, implemented in TRNSYS. A suitable case study is also presented. Here, the simulated plant is conceived for the space heating and cooling and the domestic hot water production of a small building, whose energy needs are fulfilled through a real installation (settled also for experimental purposes) built up close to Naples (South Italy). Simulation results show that the investigated system is able to reach high thermal efficiencies and very good energy performance. Finally, the economic analysis shows results comparable to those achieved through similar renewable energy systems.


1986 ◽  
Vol 51 (6) ◽  
pp. 1259-1267
Author(s):  
Josef Horák ◽  
Petr Beránek

A simulation apparatus for the experimental study of the methods of control of batch reactors is devised. In this apparatus, the production of heat by an exothermic reaction is replaced by electric heating controlled by a computer in a closed loop; the reactor is cooled with an external cooler whose dynamic properties can be varied while keeping the heat exchange area constant. The effect of the cooler geometry on its dynamic properties is investigated and the effect of the cooler inertia on the stability and safety of the on-off temperature control in the unstable pseudostationary state is examined.


1982 ◽  
Vol 47 (2) ◽  
pp. 454-464 ◽  
Author(s):  
František Jiráček ◽  
Josef Horák

The effect has been studied of the inertia of the cooling system on the reliability of control of the temperature of the reaction mixture. The study has been made using a mathematical model of the batch reactor with an exothermic reaction. The temperature has been controlled by a two-level controller opening and closing the flow of the coolant. The aim of the control has been to maintain a constant value of the degree of utilization of the cooling capacity of the reactor. The instantaneous value of the degree of utilization has been assessed from the ratio of times for which the cooling system is idle to the time of operation. The reliability of control has been studied for variable activity of the catalyst.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3298
Author(s):  
Gianpiero Colangelo ◽  
Brenda Raho ◽  
Marco Milanese ◽  
Arturo de Risi

Nanofluids have great potential to improve the heat transfer properties of liquids, as demonstrated by recent studies. This paper presents a novel idea of utilizing nanofluid. It analyzes the performance of a HVAC (Heating Ventilation Air Conditioning) system using a high-performance heat transfer fluid (water-glycol nanofluid with nanoparticles of Al2O3), in the university campus of Lecce, Italy. The work describes the dynamic model of the building and its heating and cooling system, realized through the simulation software TRNSYS 17. The use of heat transfer fluid inseminated by nanoparticles in a real HVAC system is an innovative application that is difficult to find in the scientific literature so far. This work focuses on comparing the efficiency of the system working with a traditional water-glycol mixture with the same system that uses Al2O3-nanofluid. The results obtained by means of the dynamic simulations have confirmed what theoretically assumed, indicating the working conditions of the HVAC system that lead to lower operating costs and higher COP and EER, guaranteeing the optimal conditions of thermo-hygrometric comfort inside the building. Finally, the results showed that the use of a nanofluid based on water-glycol mixture and alumina increases the efficiency about 10% and at the same time reduces the electrical energy consumption of the HVAC system.


2013 ◽  
Vol 676 ◽  
pp. 321-324
Author(s):  
Lei Guo ◽  
Qun Zhan Li

Accidents of icing on catenary have great impacts on normal operation of trains. An on-line anti-icing technology used static var generator (SVG) for catenary was proposed, which can prevent icing formation without interrupting trains normal operation. The heat balance equations for catenary were solved, whose results were compared with data provided by TB/T 3111 and testing show the equation was correct. The simulation model based on Matlab was bulit , whose results and analysis show the correctness of the method.


2021 ◽  
pp. 111122
Author(s):  
Michal Krajčík ◽  
Martin Šimko ◽  
Ondřej Šikula ◽  
Daniel Szabó ◽  
Dušan Petráš

Water ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 210
Author(s):  
Tang Liu ◽  
Shufeng Liu ◽  
Shishi He ◽  
Zhichao Tian ◽  
Maosheng Zheng

To explore the main behavior and mechanism of minimizing nitrous oxide (N2O) emission through intermittent aeration during wastewater treatment, two lab-scale sequencing batch reactors operated at intermittently aerated mode (SBR1), and continuously aerated mode (SBR2) were established. Compared with SBR2, the intermittently aerated SBR1 reached not only a higher total nitrogen removal efficiency (averaged 93.5%) but also a lower N2O-emission factor (0.01–0.53% of influent ammonia), in which short-cut nitrification and denitrification were promoted. Moreover, less accumulation and consumption of polyhydroxyalkanoates, a potential endogenous carbon source promoting N2O emission, were observed in SBR1. Batch experiments revealed that nitrifier denitrification was the major pathway generating N2O while heterotrophic denitrification played as a sink of N2O, and SBR1 embraced a larger N2O-mitigating capability. Finally, quantitative polymerase chain reaction results suggested that the abundant complete ammonia oxidizer (comammox) elevated in the intermittently aerated environment played a potential role in avoiding N2O generation during wastewater treatment. This work provides an in-depth insight into the utilization of proper management of intermittent aeration to control N2O emission from wastewater treatment plants.


Sign in / Sign up

Export Citation Format

Share Document