Revisiting Neumark’s Critical Pressure Coefficient Rule for Aircraft with Finite Wings

2022 ◽  
Author(s):  
Francisco X. Armenta ◽  
Punya Plaban ◽  
Timothy T. Takahashi
2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Yanqi Sun ◽  
Wenquan Niu

The effects of Venturi structural parameters on its hydraulic performance were studied, which provided theoretical basis for the design of Venturi injector. With an inlet diameter of 50 mm, based on the method of computational fluid dynamics (CFD), the effects of the structural parameters (such as throat taper, throat contraction ratio, and throat length) on their hydraulic performance (such as outlet faceted average velocity, minimum pressure, and critical pressure) were studied under different inlet pressures and pressure differences between inlet and outlet. A power function relationship existed between the mean velocity in outlet section and pressure difference, with an approximate flow stance index of 0.53. Minimum pressure occurred in the throat inlet wall and there was a linear relationship between the minimum pressure and the pressure difference at the inlet and outlet. The throat contraction ratio was the main factor on the effect of Venturi injector performance, which was positively correlated with outlet velocity, negatively to critical pressure, the minimal in-tube pressure, coefficient of local head loss, and fertilizer absorption ratio. For designing Venturi injector, contraction ratio should be reasonably selected according to the coefficient of local head loss and fertilizer absorption ratio.


Author(s):  
C.A. Baechler ◽  
W. C. Pitchford ◽  
J. M. Riddle ◽  
C.B. Boyd ◽  
H. Kanagawa ◽  
...  

Preservation of the topographic ultrastructure of soft biological tissues for examination by scanning electron microscopy has been accomplished in the past by using lengthy epoxy infiltration techniques, or dehydration in ethanol or acetone followed by air drying. Since the former technique requires several days of preparation and the latter technique subjects the tissues to great stress during the phase change encountered during air-drying, an alternate rapid, economical, and reliable method of surface structure preservation was developed. Turnbill and Philpott had used a fluorocarbon for the critical point drying of soft tissues and indicated the advantages of working with fluids having both moderately low critical pressures as well as low critical temperatures. Freon-116 (duPont) which has a critical temperature of 19. 7 C and a critical pressure of 432 psi was used in this study.


2021 ◽  
Vol 11 (15) ◽  
pp. 7121
Author(s):  
Shouke Li ◽  
Feipeng Xiao ◽  
Yunfeng Zou ◽  
Shouying Li ◽  
Shucheng Yang ◽  
...  

Wind tunnel tests are carried out for the Commonwealth Advisory Aeronautical Research Council (CAARC) high-rise building with a scale of 1:400 in exposure categories D. The distribution law of extreme pressure coefficients under different conditions is studied. Probability distribution fitting is performed on the measured area-averaged extreme pressure coefficients. The general extreme value (GEV) distribution is preferred for probability distribution fitting of extreme pressure coefficients. From the comparison between the area-averaged coefficients and the value from GB50009-2012, it is indicated that the wind load coefficients from GB50009-2012 may be non-conservative for the CAARC building. The area reduction effect on the extreme wind pressure is smaller than that on the mean wind pressure from the code. The recommended formula of the area reduction factor for the extreme pressure coefficient is proposed in this study. It is found that the mean and the coefficient of variation (COV) for the directionality factors are 0.85 and 0.04, respectively, when the orientation of the building is given. If the uniform distribution is given for the building’s orientation, the mean value of the directionality factors is 0.88, which is close to the directionality factor of 0.90 given in the Chinese specifications.


Author(s):  
Manjunath L Nilugal ◽  
K Vasudeva Karanth ◽  
Madhwesh N

This article presents the effect of volute chamfering on the performance of a forward swept centrifugal fan. The numerical analysis is performed to obtain the performance parameters such as static pressure rise coefficient and total pressure coefficient for various flow coefficients. The chamfer ratio for the volute is optimized parametrically by providing a chamfer on either side of the volute. The influence of the chamfer ratio on the three dimensional flow domain was investigated numerically. The simulation is carried out using Re-Normalisation Group (RNG) k-[Formula: see text] turbulence model. The transient simulation of the fan system is done using standard sliding mesh method available in Fluent. It is found from the analysis that, configuration with chamfer ratio of 4.4 is found be the optimum configuration in terms of better performance characteristics. On an average, this optimum configuration provides improvement of about 6.3% in static pressure rise coefficient when compared to the base model. This optimized chamfer configuration also gives a higher total pressure coefficient of about 3% validating the augmentation in static pressure rise coefficient with respect to the base model. Hence, this numerical study establishes the effectiveness of optimally providing volute chamfer on the overall performance improvement of forward bladed centrifugal fan.


Author(s):  
Jelle Wieme ◽  
Veronique Van Speybroeck

Thermal stress is present in metal–organic frameworks undergoing temperature changes during adsorption and desorption. We computed the thermal pressure coefficient as a proxy for this phenomenon and discuss the impact of thermal expansion mismatch.


2020 ◽  
Vol 12 (1) ◽  
pp. 406-424 ◽  
Author(s):  
Yaoguang Huang ◽  
Aining Zhao ◽  
Tianjun Zhang ◽  
Weibin Guo

AbstractIn order to explore the effective support method for deep broken roadway, based on the in situ stress test results, the analytical and numerical solutions of the stress and the range of plastic failure zone (PFZ) in a circular roadway subjected to non-uniform loads were obtained using analytical and finite difference numerical methods based on the elastoplastic theory, respectively. Their comparison results show that the analytical and numerical methods are correct and reasonable. Furthermore, the high geostress causes the stress and range of PFZ in roadway roof and floor to increase sharply while those in roadway ribs decrease. Moreover, the greater the difference of horizontal geostress in different horizontal directions is, the larger the range of PFZ in roadway roof and floor is. The shape of PFZ in roadway varies with the ratio of horizontal lateral pressure coefficient in x-direction and y-direction. Finally, according to the distribution characteristics of PFZ and range of PFZ under the non-uniformly high geostress, this paper has proposed a combined support scheme, and refined and optimized supporting parameters. The field monitoring results prove that the roadway deformation and fracture have been effectively controlled. The research results of this paper can provide theoretical foundation as well as technical reference for the stability control of deep broken roadway under non-uniformly high geostress.


Aerospace ◽  
2021 ◽  
Vol 8 (8) ◽  
pp. 203
Author(s):  
Yufei Zhang ◽  
Pu Yang ◽  
Runze Li ◽  
Haixin Chen

The unsteady flow characteristics of a supercritical OAT15A airfoil with a shock control bump were numerically studied by a wall-modeled large eddy simulation. The numerical method was first validated by the buffet and nonbuffet cases of the baseline OAT15A airfoil. Both the pressure coefficient and velocity fluctuation coincided well with the experimental data. Then, four different shock control bumps were numerically tested. A bump of height h/c = 0.008 and location xB/c = 0.55 demonstrated a good buffet control effect. The lift-to-drag ratio of the buffet case was increased by 5.9%, and the root mean square of the lift coefficient fluctuation was decreased by 67.6%. Detailed time-averaged flow quantities and instantaneous flow fields were analyzed to demonstrate the flow phenomenon of the shock control bumps. The results demonstrate that an appropriate “λ” shockwave pattern caused by the bump is important for the flow control effect.


Sign in / Sign up

Export Citation Format

Share Document