New chrysophycean stomatocysts (Chrysophyceae) for Russia from the Omsk Priirtyshye waterbodies

2021 ◽  
Vol 55 (1) ◽  
pp. 7-18
Author(s):  
O. P. Bazhenova ◽  
D. A. Kapustin

Eight new morphotypes of chrysophycean stomatocysts for Russia were recorded from the plankton of the Omsk Priirtyshye waterbodies. Their descriptions based on the electron microscopical observations as well as original illustrations are given. The differences of the observed specimens from the type ones are discussed. It was shown that presence/absence of lacunae and their diameter are rather variable features.

Author(s):  
F.W. Van Leeuwen

In order to obtain specific and optimal ultrastructural localization of vasopressin and oxytocin in the hypothalamo-neurohypophyseal system of the rat, 2 staining procedures and several tissue treatments were evaluated using neurohypophyseal tissue. It appeared from these studies that post-embedding staining with the unlabeled antibody enzyme method developed by Sternberger allows greater dilution of the first antibody (anti-vasopressin, 1:4800) than the indirect procedure (1:320) using a peroxidase conjugate as second antibody. Immersion fixation with 4% formalin during 24 hours gave better results (general ultrastructure, immunoreactivity) than those obtained by perfusion fixation with 2.5% glutaraldehyde-1% paraformaldehyde or freeze substitution.Since no reliable specificity tests were performed at the electron microscopical level, tests were developed for antibodies against both vasopressin and oxytocin. For anti-vasopressin plasma neural lobes of homozygous Brattleboro rats, that are lacking vasopressin by a genet- ical defect, were used. For antibodies against both hormones serial sections were used that were alternately incubated with the antibodies.


Author(s):  
P. Bonhomme ◽  
A. Beorchia

We have already described (1.2.3) a device using a pockel's effect light valve as a microscopical electron image converter. This converter can be read out with incoherent or coherent light. In the last case we can set in line with the converter an optical diffractometer. Now, electron microscopy developments have pointed out different advantages of diffractometry. Indeed diffractogram of an image of a thin amorphous part of a specimen gives information about electron transfer function and a single look at a diffractogram informs on focus, drift, residual astigmatism, and after standardizing, on periods resolved (4.5.6). These informations are obvious from diffractogram but are usualy obtained from a micrograph, so that a correction of electron microscope parameters cannot be realized before recording the micrograph. Diffractometer allows also processing of images by setting spatial filters in diffractogram plane (7) or by reconstruction of Fraunhofer image (8). Using Electrotitus read out with coherent light and fitted to a diffractometer; all these possibilities may be realized in pseudoreal time, so that working parameters may be optimally adjusted before recording a micrograph or before processing an image.


Author(s):  
J. A. Traquair ◽  
E. G. Kokko

With the advent of improved dehydration techniques, scanning electron microscopy has become routine in anatomical studies of fungi. Fine structure of hyphae and spore surfaces has been illustrated for many hyphomycetes, and yet, the ultrastructure of the ubiquitous soil fungus, Geomyces pannorus (Link) Sigler & Carmichael has been neglected. This presentation shows that scanning and transmission electron microscopical data must be correlated in resolving septal structure and conidial release in G. pannorus.Although it is reported to be cellulolytic but not keratinolytic, G. pannorus is found on human skin, animals, birds, mushrooms, dung, roots, and frozen meat in addition to various organic soils. In fact, it readily adapts to growth at low temperatures.


Author(s):  
Virgil Peck ◽  
W. L. Carter

Any electron microscopical study of the morphology of bulk polymers has throughout the years been hampered by the lack of any real ability to produce meaningful surface variations for replication. True etching of polymers should show crystalline and amorphous regions in some form of relief. The use of solvents, acids, organic vapors, and inert ion bombardment to etch samples has proved to be useful only in limited applications. Certainly many interpretations of these results are subject to question.The recent use of a radiofrequency (R. F.) plasma of oxygen to degrade and remove organic material with only minor heating has opened a new possibility for etching polymers. However, rigid control of oxygen flow, time, current, and sample position are necessary in order to obtain reproducible results. The action is confined to surface layers; the molecular weight of the polymer residue after heavy etching is the same as the molecular weight of the polymer before attack, within the accuracy of measurement.


Author(s):  
James Cronshaw

Long distance transport in plants takes place in phloem tissue which has characteristic cells, the sieve elements. At maturity these cells have sieve areas in their end walls with specialized perforations. They are associated with companion cells, parenchyma cells, and in some species, with transfer cells. The protoplast of the functioning sieve element contains a high concentration of sugar, and consequently a high hydrostatic pressure, which makes it extremely difficult to fix mature sieve elements for electron microscopical observation without the formation of surge artifacts. Despite many structural studies which have attempted to prevent surge artifacts, several features of mature sieve elements, such as the distribution of P-protein and the nature of the contents of the sieve area pores, remain controversial.


Author(s):  
S. Lehner ◽  
H.E. Bauer ◽  
R. Wurster ◽  
H. Seiler

In order to compare different microanalytical techniques commercially available cation exchange membrane SC-1 (Stantech Inc, Palo Alto), was loaded with biologically relevant elements as Na, Mg, K, and Ca, respectively, each to its highest possible concentration, given by the number concentration of exchangeable binding sites (4 % wt. for Ca). Washing in distilled water, dehydration through a graded series of ethanol, infiltration and embedding in Spurr’s low viscosity epoxy resin was followed by thin sectioning. The thin sections (thickness of about 50 nm) were prepared on carbon foils and mounted on electron microscopical finder grids.The samples were analyzed with electron microprobe JXA 50A with transmitted electron device, EDX system TN 5400, and on line operating image processing system SEM-IPS, energy filtering electron microscope CEM 902 with EELS/ESI and Auger spectrometer 545 Perkin Elmer.With EDX, a beam current of some 10-10 A and a beam diameter of about 10 nm, a minimum-detectable mass of 10-20 g Ca seems within reach.


Author(s):  
Hilton H. Mollenhauer

Many factors (e.g., resolution of microscope, type of tissue, and preparation of sample) affect electron microscopical images and alter the amount of information that can be retrieved from a specimen. Of interest in this report are those factors associated with the evaluation of epoxy embedded tissues. In this context, informational retrieval is dependant, in part, on the ability to “see” sample detail (e.g., contrast) and, in part, on tue quality of sample preservation. Two aspects of this problem will be discussed: 1) epoxy resins and their effect on image contrast, information retrieval, and sample preservation; and 2) the interaction between some stains commonly used for enhancing contrast and information retrieval.


Author(s):  
A.D. Hyatt

Bluetongue virus (BTV) is the type species os the genus orbivirus in the family Reoviridae. The virus has a fibrillar outer coat containing two major structural proteins VP2 and VP5 which surround an icosahedral core. The core contains two major proteins VP3 and VP7 and three minor proteins VP1, VP4 and VP6. Recent evidence has indicated that the core comprises a neucleoprotein center which is surrounded by two protein layers; VP7, a major constituent of capsomeres comprises the outer and VP3 the inner layer of the core . Antibodies to VP7 are currently used in enzyme-linked immunosorbant assays and immuno-electron microscopical (JEM) tests for the detection of BTV. The tests involve the antibody recognition of VP7 on virus particles. In an attempt to understand how complete viruses can interact with antibodies to VP7 various antibody types and methodologies were utilized to determine the physical accessibility of the core to the external environment.


Author(s):  
Morten H. Nielsen ◽  
Lone Bastholm

During the last 5 years the diameter of the gold probes used for immuno-cytochemical staining at the electron microscopical (EM) level has been decreased. The advantage of small diameter gold probes is an overall increased labelling density. The disadvantage is a lower detectability due to the low electron density of smaller gold particles consequently an inconvenient high primary magnification needed for EM examination. Since 1 nm gold particles are barely visible by conventional EM examination the need for enlargement by silverenhancement of the gold particles has increased.In the present study of ultrathin cryosectioned material the results of immunostaining using 5 nm gold conjugated antibody and 1 nm gold conjugated antibodies are compared after silverenhancement of the 1 nm gold particles.Slices of freshly isolated mouse pituitary gland were immersion fixed for 20 min in 2 % glutaraldehyde /2 % paraformaldehyde. Blocks cryoprotected with 2.3 M sucrose were frozen in liquid nitrogen and ultra-cryosectioned on a RMC cryoultra-microtome.


Author(s):  
P. Moine ◽  
G. M. Michal ◽  
R. Sinclair

Premartensitic effects in near equiatomic TiNi have been pointed out by several authors(1-5). These include anomalous contrast in electron microscopy images (mottling, striations, etc. ),diffraction effects(diffuse streaks, extra reflections, etc.), a resistivity peak above Ms (temperature at which a perceptible amount of martensite is formed without applied stress). However the structural changes occuring in this temperature range are not well understood. The purpose of this study is to clarify these phenomena.


Sign in / Sign up

Export Citation Format

Share Document