Failure Analysis Process Flows and Common Failure Mechanisms in Flip-Chip Packaged Device

Author(s):  
Steve Hsiung ◽  
Victer Chan

Abstract With the increasing complexity of packaging technology, especially Flip-chip, package failure analysts face challenges to identify failure root cause. Due to the complex construction of Flip-chip packages, the conventional failure analysis process flow needs to be enhanced. Thus, generating a bench marked failure analysis process flow specifically for Flip-chip packaged devices becomes necessary. In this paper, the failure analysis process flow for Flip-chip package devices along with different failure mechanisms will be discussed and demonstrated. For instance, even in a simple continuity-open failure, instead of cross-sectioning the device as the initial fault identification step, the process flow details how to start from non-destructive C-SAM, TDR, to destructive die removal, polishing and finally cross-sectioning.

Author(s):  
Zhaofeng Wang

Abstract The present paper studies several failure mechanisms at both UBM and Cu substrate side for flip-chip die open contact failures in multi-chip-module plastic BGA-LGA packages. A unique failure analysis process flow, starting from non-disturbance inspection of x-ray, substrate and die level C-SAM, bump x-section followed by a bump interface integrity test including under-fill etching and bump pull test and/or substrate etch has been developed. Four different types of failure mechanism in multiple chip module that are associated with open/intermittent contact, ranging from device layout design, UBM forming process defect, to assembly related bump-substrate interface delamination have been identified. The established FA process has been proved to be efficient and accurate with repeatable result. It has facilitated and accelarated new product qualification processes for a line of high power MCM modules.


Author(s):  
O. Diaz de Leon ◽  
M. Nassirian ◽  
C. Todd ◽  
R. Chowdhury

Abstract Integration of circuits on semiconductor devices with resulting increase in pin counts is driving the need for improvements in packaging for functionality and reliability. One solution to this demand is the Flip- Chip concept in Ultra Large Scale Integration (ULSI) applications [1]. The flip-chip technology is based on the direct attach principle of die to substrate interconnection.. The absence of bondwires clearly enables packages to become more slim and compact, and also provides higher pin counts and higher-speeds [2]. However, due to its construction, with inherent hidden structures the Flip-Chip technology presents a challenge for non-destructive Failure Analysis (F/A). The scanning acoustic microscope (SAM) has recently emerged as a valuable evaluation tool for this purpose [3]. C-mode scanning acoustic microscope (C-SAM), has the ability to demonstrate non-destructive package analysis while imaging the internal features of this package. Ultrasonic waves are very sensitive, particularly when they encounter density variations at surfaces, e.g. variations such as voids or delaminations similar to air gaps. These two anomalies are common to flip-chips. The primary issue with this package technology is the non-uniformity of the die attach through solder ball joints and epoxy underfill. The ball joints also present defects as open contacts, voids or cracks. In our acoustic microscopy study packages with known defects are considered. It includes C-SCAN analysis giving top views at a particular package interface and a B-SCAN analysis that provides cross-sectional views at a desired point of interest. The cross-section analysis capability gives confidence to the failure analyst in obtaining information from a failing area without physically sectioning the sample and destroying its electrical integrity. Our results presented here prove that appropriate selection of acoustic scanning modes and frequency parameters leads to good reliable correlation between the physical defects in the devices and the information given by the acoustic microscope.


Author(s):  
Sebastian Brand ◽  
Matthias Petzold ◽  
Peter Czurratis ◽  
Peter Hoffrogge

Abstract In industrial manufacturing of microelectronic components, non-destructive failure analysis methods are required for either quality control or for providing a rapid fault isolation and defect localization prior to detailed investigations requiring target preparation. Scanning acoustic microscopy (SAM) is a powerful tool enabling the inspection of internal structures in optically opaque materials non-destructively. In addition, depth specific information can be employed for two- and three-dimensional internal imaging without the need of time consuming tomographic scan procedures. The resolution achievable by acoustic microscopy is depending on parameters of both the test equipment and the sample under investigation. However, if applying acoustic microscopy for pure intensity imaging most of its potential remains unused. The aim of the current work was the development of a comprehensive analysis toolbox for extending the application of SAM by employing its full potential. Thus, typical case examples representing different fields of application were considered ranging from high density interconnect flip-chip devices over wafer-bonded components to solder tape connectors of a photovoltaic (PV) solar panel. The progress achieved during this work can be split into three categories: Signal Analysis and Parametric Imaging (SA-PI), Signal Analysis and Defect Evaluation (SA-DE) and Image Processing and Resolution Enhancement (IP-RE). Data acquisition was performed using a commercially available scanning acoustic microscope equipped with several ultrasonic transducers covering the frequency range from 15 MHz to 175 MHz. The acoustic data recorded were subjected to sophisticated algorithms operating in time-, frequency- and spatial domain for performing signal- and image analysis. In all three of the presented applications acoustic microscopy combined with signal- and image processing algorithms proved to be a powerful tool for non-destructive inspection.


Author(s):  
Carlo Grilletto ◽  
Steve Hsiung ◽  
Andrew Komrowski ◽  
John Soopikian ◽  
Daniel J.D. Sullivan ◽  
...  

Abstract This paper describes a method to "non-destructively" inspect the bump side of an assembled flip-chip test die. The method is used in conjunction with a simple metal-connecting "modified daisy chain" die and makes use of the fact that polished silicon is transparent to infra-red (IR) light. The paper describes the technique, scope of detection and examples of failure mechanisms successfully identified. It includes an example of a shorting anomaly that was not detectable with the state of the art X-ray equipment, but was detected by an IR emission microscope. The anomalies, in many cases, have shown to be the cause of failure. Once this has been accomplished, then a reasonable deprocessing plan can be instituted to proceed with the failure analysis.


2011 ◽  
Vol 2011 (1) ◽  
pp. 001078-001083 ◽  
Author(s):  
K. Fahey ◽  
R. Estrada ◽  
L. Mirkarimi ◽  
R. Katkar ◽  
D. Buckminster ◽  
...  

This paper describes the utilization of non-destructive imaging using 3D x-ray microscopy for package development and failure analysis. Four case studies are discussed to explain our methodology and its impact on our advanced packaging development effort. Identifying and locating failures embedded deep inside the package, such as a solder fatigue failure within a flip chip package, without the need for physical cross-sectioning is of substantial benefit because it preserves the package for further analysis. Also of utility is the ability to reveal the structural details of the package while producing superior quality 2D and volumetric images. The technique could be used not only for analysis of defects and failures, but also to characterize geometries and morphologies during the process and package development stage.


Author(s):  
Kai Wang ◽  
Sadia Lone ◽  
Colin Thomas ◽  
Rhys Weaver

Abstract System suppliers in the automotive market have an expectation that their IC suppliers provide products with low defective parts per million (DPPM) and have methodologies in place to drive towards 0ppm (Zero Parts Per Million). IC suppliers to the automotive market have supply chains and test methodologies in place to achieve such low DPPMs, but the systems suppliers will still require root cause analysis on every failure. The IC supplier is expected to demonstrate a containment, corrective action and continuous improvement in a very tight time frame. This additional demand of automotive customers poses a challenge to the quality of IC devices and the concept of cross departmental failure analysis. In this paper, we look at a complex Wi-Fi design with multiple IEEE specific radios, and how to address the few parts that escape the rigorous testing by IC supplier to improve the quality for the automotive IC.


1998 ◽  
Author(s):  
M. Lipschutz ◽  
R. Brannam ◽  
T. Nguyentat

Abstract This article details the results of a failure analysis performed on a Qualification Unit injector for a military satellite thrusters and explains that the failure was initially detected due to a shift in performance during qualification testing. Failure analysis involved non-destructive evaluation on the injector using micro-focus X-ray and scanning electron microscopy. Serial cross-sectional metallography was then performed, with each cross-section documented by optical microscopy and SEM. The failure analysis resulted in three main conclusions: (1) the root cause of the failure was attributed to multiple detonations in or around the damaged orifice; these detonations were likely caused by fuel and/or combustion products condensing in the orifice between pulses and then igniting during a subsequent pulse; (2) multiple damage mechanisms were identified in addition to the ZOT detonations; and (3) the material and platelet manufacturing process met all design parameters.


Author(s):  
E. H. Yeoh ◽  
W. M. Mak ◽  
H. C. Lock ◽  
S. K. Sim ◽  
C. C. Ooi ◽  
...  

Abstract As device interconnect layers increase and transistor critical dimensions decrease below sub-micron to cater for higher speed and higher packing density, various new and subtle failure mechanisms have emerged and are becoming increasingly prevalent. Silicon dislocation is a new failure mechanism that falls in this category and was for the first time, uncovered in submicron multilayered CMOS devices. This mechanism was responsible for a systematic yield problem; identified as the 'centre GFA wafer' functional failure problem. In this paper, several breakthrough failure analysis techniques used to narrow down and identify this new mechanism will be presented. Root cause determination and potential solution to this problem will also be discussed.


2018 ◽  
Author(s):  
Sze Yee Tan ◽  
Chiu Soon Wong ◽  
Chea Wee Lo ◽  
Cin Sheng Goh

Abstract In the back-end assembly process, all of the packages will be tested prior to disposition to the customers in order to filter out any device with failure. For a reject unit with an unknown failure mechanism, it will be subjected to a comprehensive failure analysis (FA) to identify the root cause of the failure. Non-destructive verification, following by front-side decapsulation and internal physical inspection is the common way to visualise and identify the physical defect that usually causes the failure of a device during the back-end assembly process. For certain failures, visualization of the defect might not be straight forward after the decapsulation because the defect may be embedded or buried underneath a layer or wedge bond on the die. In this case, a more complicated FA analysis flow which comprises various precision techniques such as parallel lapping, hotspot localisation and focused-ion-beam (FIB) analyses will be needed to thin down the top layer/wedge bond for a precise localisation of the defect prior to precision analysis by FIB. However, the process to thin down the top layer/wedge bond with an exposed die of a partially decapsulated package is a tricky job as artefacts such as crack/scratches on die are likely to be introduced during the process of polishing. Also it is relatively difficult to control the thickness and levelling of the top layer/wedge bond during the thinning process. In this work, we developed a method that allows the analyst to re-cap the partially decapped package, and also to precisely measure and thin down the top layer to an accuracy of less than < 2um without the introduction of artefacts.


Sign in / Sign up

Export Citation Format

Share Document