scholarly journals Pedicle screw placement in the lumbar spine: effect of trajectory and screw design on acute biomechanical purchase

2015 ◽  
Vol 22 (5) ◽  
pp. 503-510 ◽  
Author(s):  
Steven Wray ◽  
Ronnie Mimran ◽  
Sasidhar Vadapalli ◽  
Snehal S. Shetye ◽  
Kirk C. McGilvray ◽  
...  

OBJECT Low bone mineral density in patients undergoing lumbar spinal surgery with screws is an especially difficult challenge because poor bone quality can severely compromise the maximum achievable purchase of the screws. A relatively new technique, the cortical bone screw trajectory, utilizes a medialized trajectory in the caudocephalad direction to engage a greater amount of cortical bone within the pars interarticularis and pedicle. The objectives of this cadaveric biomechanical study were to 1) evaluate a cortical screw system and compare its mechanical performance to the traditional pedicle screw system; 2) determine differences in bone quality associated with the cortical screw trajectory versus the normal pedicle screw insertion technique; 3) determine the cortical wall breach rate with both the cortical and traditional screw trajectories; and 4) determine the performance of the traditional screw in the cortical screw trajectory. METHODS Fourteen fresh frozen human lumbar spine sections (L1–5) were used in this study (mean age 57 ± 19 years). The experimental plan involved drilling and tapping screw holes for 2 trajectories under navigation (a traditional pedicle screw and a cortical screw) in both high-and low-quality vertebrae, measuring the bone quality associated with these trajectories, placing screws in the trajectories, and evaluating the competence of the screw purchase via 2 mechanical tests (pullout and toggle). The 3 experimental variants were 1) traditional pedicle screws placed in the traditional pedicle screw trajectory, 2) traditional pedicle screws placed in the cortical screw trajectory, and 3) cortical screws placed in the cortical screw trajectory. RESULTS A statistically significant increase in bone quality was observed for the cortical trajectories with a cortical screw (42%; p < 0.001) and traditional pedicle screw (48%; p < 0.001) when compared to the traditional trajectory with a traditional pedicle screw within the high-quality bone group. These significant differences were also found in the lowquality bone cohort. All mechanical parameter comparisons (screw type and trajectory) between high-quality and lowquality samples were significant (p < 0.01), and these data were all linearly correlated (r ≥ 0.65) to bone mineral density. Not all mechanical parameters determined from pullout and toggle testing were statistically significant between the 3 screw/trajectory combinations. The incidence of cortical wall breach with the cortical or traditional pedicle screw trajectories was not significantly different. CONCLUSIONS The data demonstrated that the cortical trajectory provides denser bone that allows for utilization of smaller screws to obtain mechanical purchase that is equivalent to long pedicle screws placed in traditional pedicle screw trajectories for both normal- and low-quality bone. Overall, this biomechanical study in cadavers provides evidence that the cortical screw trajectory represents a good option to obtain fixation for the lumbar spine with low-quality bone.

2020 ◽  
Vol 14 (3) ◽  
pp. 265-272
Author(s):  
Atsushi Ikeura ◽  
Taketoshi Kushida ◽  
Kenichi Oe ◽  
Yoshihisa Kotani ◽  
Muneharu Ando ◽  
...  

Study Design: Biomechanical study.Purpose: To assess the correlation between the computed tomography (CT) values of the pedicle screw path and screw pull-out strength.Overview of Literature: The correlation between pedicle screw pull-out strength and bone mineral density has been well established. In addition, several reports have demonstrated a correlation between bone mineral density and CT values. However, no previous biomechanical studies investigated the correlation between CT values and pedicle screw pull-out strength.Methods: Sixty fresh-frozen lumbar vertebrae from 6-month-old pigs were used. Before screw insertion, the CT values of the screw path were obtained for each sample. Specimens were then randomly divided into three equal groups. Each group had one of three pedicle screws inserted: 4.0-mm LEGACY (4.0-LEG), 4.5-mm LEGACY (4.5-LEG), or 4.5-mm SOLERA (4.5-SOL) (all from Medtronic Sofamor Danek Inc., Memphis, TN, USA). Each screw had a consistent 30-mm thread length. Axial pull-out testing was performed at a rate of 1.0 mm/min. Correlations between the CT values and pedicle screw pull-out strength were evaluated using Pearson’s correlation coefficient analysis.Results: The correlation coefficients between the CT values of the screw path and pedicle screw pull-out strength for the 4.0-LEG, 4.5-LEG, and 4.5-SOL groups were 0.836 (<i>p</i> <0.001), 0.780 (<i>p</i> <0.001), and 0.873 (<i>p</i> <0.001), respectively. Greater CT values were associated with greater screw pull-out strength.Conclusions: The CT values of the screw path were strongly positively correlated with pedicle screw pull-out strength, regardless of the screw type and diameter, suggesting that the CT values could be clinically useful for predicting pedicle screw pull-out strength.


2021 ◽  
Vol 11 (22) ◽  
pp. 10583
Author(s):  
Kuo-Chih Su ◽  
Kun-Hui Chen ◽  
Chien-Chou Pan ◽  
Cheng-Hung Lee

Cortical bone trajectory (CBT) is increasingly used in spinal surgery. Although there are many biomechanical studies, the biomechanical effect of CBT in combination with traditional pedicle screws is not detailed. Therefore, the purpose of this study was to investigate the effects of the traditional pedicle screw and CBT screw implantation on the lumbar spine using finite element methods. Based on the combination of the traditional pedicle screw and the CBT system implanted into the lumbar spine, four finite element spinal lumbar models were established. The models were given four different load conditions (flexion, extension, lateral bending, and axial rotation), and the deformation and stress distribution on the finite element model were observed. The results show that there was no significant difference in the structural stability of the lumbar spine model between the traditional pedicle screw system and the CBT system. In addition, CBT may reduce stress on the endplate. Different movements performed by the model may have significant biomechanical effects on the spine and screw system. Clinical spinal surgeons may also consider using the CBT system in revision spinal surgery, which may contribute to smaller wounds.


2016 ◽  
Vol 25 (6) ◽  
pp. 727-732 ◽  
Author(s):  
Jeffrey P. Mullin ◽  
Breanna Perlmutter ◽  
Eric Schmidt ◽  
Edward Benzel ◽  
Michael P. Steinmetz

OBJECTIVE In 2009, Santoni and colleagues described a novel technique of posterior instrumentation; the cortical bone trajectory (CBT) was described as a caudocephalad and medial-to-lateral trajectory. Reported indications for CBT fixation include patients with osteoporosis, single-level degenerative disease, or adjacent-segment disease (ASD). In cases of revision surgery, it is technically possible and beneficial to place a traditional pedicle screw and a CBT screw at the same spinal level and side. It remains unclear as to the feasibility of placing both a traditional and a CBT screw at all levels of the lumbar spine and with varying trajectories of the preexisting traditional pedicle screws. Therefore, the authors conducted a study to radiographically assess the feasibility of using CBT and traditional pedicle screws at the same level in a large patient population. METHODS Using a 3D Spine Navigation WorkStation, the authors assessed 47 lumbar spine CT scans. These images were obtained from 2 disparate groups of patients: those who had previously undergone traditional pedicle instrumentation (prior surgery group) and those who had not (no prior surgery group). The authors virtually placed traditional pedicle and CBT screws at each lumbar level bilaterally. It was then determined if the dual trajectories were feasible, as defined by the presence or absence of a collision of the screw trajectories based on 3D imaging. RESULTS Overall, the authors evaluated 47 patients and were able to successfully plan dual trajectories in 50% of the pedicles. The no prior surgery group, compared with the prior surgery group, had a significantly greater success rate for dual trajectories. This difference was most significant in the lower lumbar levels (L3–5) where the prior instrumented group had success rates lower than 40% compared with the no prior surgery group's success rate, which was greater than 70%. There was a significant difference between each lumbar level in the lower spine. CONCLUSIONS There is a significant difference in the feasibility of planning CBT screws in patients who have undergone prior pedicle instrumentation compared with placing CBT and traditional pedicle screws simultaneously, but dual trajectory pedicle screws are a feasible option for posterior lumbar spinal instrumentation, especially as a de novo option in osteoporotic patients or in patients with ASD who underwent previous pedicle instrumentation. Ultimately, the practical clinical utility and biomechanical effects on the spine and instrumentation construct would require additional study.


2022 ◽  
Vol 11 (2) ◽  
pp. 330
Author(s):  
Alicia R. Jones ◽  
Koen Simons ◽  
Susan Harvey ◽  
Vivian Grill

Individuals with primary hyperparathyroidism (PHPT) have reduced bone mineral density (BMD) according to dual X-ray absorptiometry at cortical sites, with relative sparing of trabecular BMD. However, fracture risk is increased at all sites. Trabecular bone score (TBS) may more accurately describe their bone quality and fracture risk. This study compared how BMD and TBS describe bone quality in PHPT. We conducted a retrospective cross-sectional study with a longitudinal component, of adults with PHPT, admitted to a tertiary hospital in Australia over ten years. The primary outcome was the TBS at the lumbar spine, compared to BMD, to describe bone quality and predict fractures. Secondary outcomes compared changes in TBS after parathyroidectomy. Of 68 included individuals, the mean age was 65.3 years, and 79% were female. Mean ± SD T-scores were −1.51 ± 1.63 at lumbar spine and mean TBS was 1.19 ± 0.12. Only 20.6% of individuals had lumbar spine BMD indicative of osteoporosis, while 57.4% of TBS were ≤1.20, indicating degraded architecture. There was a trend towards improved fracture prediction using TBS compared to BMD which did not reach statistical significance. Comparison of 15 individuals following parathyroidectomy showed no improvement in TBS.


2019 ◽  
Vol 9 (8) ◽  
pp. 1525 ◽  
Author(s):  
Shen ◽  
Kim ◽  
Kang ◽  
Yeom

Although dual-threaded pedicle screws have been developed, the advantages over single-threaded screws remain controversial. We aimed to investigate the biomechanical performance of two types of dual-threaded pedicle screw by comparing their pullout strength with that of a single-threaded screw in relation to bone quality. Four types of pedicle screw with different thread patterns were designed. Type I: single-threaded screw; Type II: double-threaded screw; Type III: dual-threaded screw; Type IV: a newly designed double dual-threaded screw. Five types of polyurethane foams simulating various degrees of bone quality were used. These were: Type A: cancellous bone; Type B: cancellous bone with cortical bone in the upper margin; Type C: osteoporotic cancellous bone; Type D: osteoporotic cancellous bone with cortical bone in the upper margin; and Type E: osteoporotic bone with cortical bone in the upper and lower margins. A comparison of the pullout strength of Type I, II, and III screws in Type A, B, C and D bone specimens was performed. Type C and E bone specimens were used for comparisons among Type I, II, and IV screws. Compared to the single-threaded screw, the dual-threaded pedicle screws exhibited higher pullout strength in normal-quality bone and significantly lower pullout strength in compromised osteoporotic bone. However, the double dual-threaded screw exhibited better pullout biomechanics in osteoporotic bone with bi-cortical bone.


2009 ◽  
Vol 11 (1) ◽  
pp. 28-33 ◽  
Author(s):  
Mario J. Cardoso ◽  
Anton E. Dmitriev ◽  
Melvin D. Helgeson ◽  
Frederick Stephens ◽  
Victoria Campbell ◽  
...  

Object Transpedicular instrumentation at C-7 has been well accepted, but salvage techniques are limited. Lamina screws have been shown to be a biomechanically sound salvage technique in the proximal thoracic spine, but have not been evaluated in the lower cervical spine. The following study evaluates the anatomical feasibility of lamina screws at C-7 as well as their bone-screw interface strength as a salvage technique. Methods Nine fresh-frozen C-7 cadaveric specimens were scanned for bone mineral density using dual energy x-ray absorptiometry. Prior to testing, all specimens were imaged using CT to obtain 1-mm axial sections. Caliper measurements of both pedicle width and laminar thickness were obtained. On the right side, pedicle screws were first inserted and then pulled out. Salvage intralaminar screws were inserted into the left lamina from the right spinous process/lamina junction and then pulled out. All screws were placed by experienced cervical spine surgeons under direct fluoroscopic visualization. Pedicle and lamina screws were 4.35- and 3.5-mm in diameter, respectively. Screws sizes were chosen based on direct and radiographic measurements of the respective anatomical regions. Insertional torque (IT) was measured in pounds per inch. Tensile loading to failure was performed in-line with the screw axis at a rate of 0.25 mm/sec using a MiniBionix II system with data recorded in Newtons. Results Using lamina screws as a salvage technique generated mean pullout forces (778.9 ± 161.4 N) similar to that of the index pedicle screws (805.3 ± 261.7 N; p = 0.796). However, mean lamina screw peak IT (5.2 ± 2.0 lbs/in) was significantly lower than mean index pedicle screw peak IT (9.1 ± 3.6 lbs/in; p = 0.012). Bone mineral density was strongly correlated with pedicle screw pullout strength (r = 0.95) but less with lamina screw pullout strength (r = 0.04). The mean lamina width measured using calipers (5.7 ± 1.0 mm) was significantly different from the CTmeasured mean lamina width (5.1 ± 0.8 mm; p = 0.003). Similarly, the mean pedicle width recorded with calipers (6.6 ± 1.1 mm) was significantly different from the CT-measured mean pedicle width (6.2 ± 1.3 mm; p = 0.014). The mean laminar width measured on CT at the thinnest point ranged from 3.8 to 6.8 mm, allowing a 3.5-mm screw to be placed without difficulty. Conclusions These results suggest that using lamina screws as a salvage technique at C-7 provides similar fixation strength as the index pedicle screw. The C-7 lamina appears to have an ideal anatomical width for the insertion of 3.5-mm screws commonly used for cervical fusions. Therefore, if the transpedicular screw fails, using intralaminar screws appear to be a biomechanically sound salvage technique.