scholarly journals Mathematical modeling of energy loss reduction in gear boxes of oil and gas technological transport

2021 ◽  
Vol 101 (3) ◽  
pp. 70-80
Author(s):  
I. Mykytiy ◽  

The work is aimed at solving the problem of reducing energy losses in transmission units of hoisting machines for repairing wells. Method of rapid heating and maintaining the optimal temperature in the transmission units of lifting units by using the heat of the exhaust gases was proposed. Analysis of features of a design of transmissions of lifting installations for repair of wells is carried out. Studies of viscosity-temperature characteristics of modern transmission oils and temperature regime in transmission units have been performed. A mathematical model of energy release in transmission units during the operation of lifting units is proposed. Installed energy consumption for friction in the gears of the transmission units. Friction energy losses in bearings of transmission mechanisms of lifting units are determined. A method for reducing energy losses in transmission units of hoisting installations for well repair is proposed. Experimental studies of the implementation of the proposed method of reducing energy losses in transmission units. Dependence of power losses in the gearbox of lifting units depending on the temperature and grade of transmission oil is established. The dependence of power losses in the gearbox of the lifting unit of the UPA 60 / 80 A model depending on the temperature and grade of transmission oil is obtained. The results of calculations of fuel consumption in the gearbox of the lifting unit of the UPA 60 / 80A model with different power drives and at different temperatures of transmission oil are given

2011 ◽  
Vol 1295 ◽  
Author(s):  
X. H. Sang ◽  
A. Kulovits ◽  
J. Wiezorek

ABSTRACTAccurate Debye-Waller (DW) factors of chemically ordered β-NiAl (B2, cP2, ${\rm{Pm}}\bar 3 {\rm{m}}$) have been measured at different temperatures using an off-zone axis multi-beam convergent beam electron diffraction (CBED) method. We determined a cross over temperature below which the DW factor of Ni becomes smaller than that of Al of ~90K. Additionally, we measured for the first time DW factors and structure factors of chemically ordered γ1-FePd (L10, tP2, P4/mmm) at 120K. We were able to simultaneously determine all four anisotropic DW factors and several low order structure factors using different special off-zone axis multi-beam convergent beam electron diffraction patterns with high precision and accuracy. An electron charge density deformation map was constructed from measured X-ray diffraction structure factors for γ1-FePd.


Author(s):  
S.V. Matsenko ◽  
◽  
V.M. Minko ◽  
A.A. Koshelev ◽  
V.Yu. Piven ◽  
...  

Violation of industrial safety rules during the operation of offshore facilities for the production, storage and transportation of the hydrocarbon raw materials leads in the most cases to pollution of the marine environment with oil and its components. The works on localization and elimination of such pollution are carried out with the help of vessels of the technical support fleet and booms. When developing oil spill response plans at such facilities, a calculated determination of the technical characteristics of vessels and booms is required that are sufficient to carry out the planned activities. The basic design principles for determining the towing capacity of the technical fleet vessels involved in the localization and elimination of oil and oil product spills by trawling methods are given in the article. The calculation is based on theoretical studies performed by the authors of the physical processes occurring during the movement of objects of a mobile trawling order in the sea area. The results obtained during the course of theoretical studies were confirmed by the experimental studies carried out by the authors personally using the real pieces of equipment in the actual development of tasks for training spill containment by trawling. As a result, the empirical dependencies were obtained and experimentally confirmed, which can be used to calculate technical characteristics of the ships as part of the mobile orders and anchor systems as part of stationary orders intended for the localization and elimination of oil pollution. These results can be used, among other things, for the calculated substantiation of the technical characteristics of the technical fleet vessels designed to ensure safety of the offshore facilities for production, storage, and transportation of the hydrocarbon raw materials.


2021 ◽  
Author(s):  
Bagus Muliadi Nasution ◽  
Andrew Yonathan ◽  
Muthi Abdillah ◽  
Wang Zhen

Abstract Organic acid has been widely applied for inorganic scale treatment in oil and gas industry including well stimulation and scale inhibitor. Thanks to its low corrosivity and slower reaction rate with rock, organic acid is considered to offer better performance comparing to strong acid - Hydrochloric Acid (HCl). Yet, proper treatment requires vigorous analysis and experiment in order to meet foremost expectations. Besides, mistreatment of scale could result in formation damage including clay precipitation. Pre-treatment experiments were performed on Zelda field at South East Sumatera block, that has faced with scale problem for ages. Water sample was taken from flowing Zelda A-08 well to be analyzed for mineral's saturation level. Scale was extracted from three sources including tubing, sand bailer, and Electrical Submersible Pump (ESP) of Zelda A-08. Those scale were treated in X-Ray Powder Diffraction (XRD) for mineral composition, and solubility test that utilized two types of acid system - formic acid (HCOOH) and hydrochloric acid (HCl) for comparison. Anti-swelling test and corrosion test were performed to examine the effectiveness of clay stabilizer and corrosion inhibitor. As for carbonate analysis, both formic acid 9% and HCl 15% have comparable solubility (98.17% vs 98% for tubing's scale, 91.86% vs 82.79% for ESP's scale, and 70.30% vs 68.07% for sand bailer's scale). Yet, longer reaction is carried out by formic acid 9% (1 hour) comparing to HCl 15% (18 minutes). For silicate analysis, HF-formic acid provided the higher solubility than HF-HCl (8.34% vs 5.67% for ESP's scale and 30.48% vs 25.68% for sand bailer's scale). On anti-swelling test, by reducing swelling tendency up to 62.6%, it proves that examined clay stabilizer works perfectly against swelling potential of clay, despite of high swelling tendency of sand bailer's scale (25.8%). On corrosion test, adding on corrosion inhibitor (pyridine-based) into solution results in regular HCl 15% has corrosion rate 26.279 g/m2.h which is much higher (300%) than HF-HCl (7.977 g/m2.h) and HF-formic acid (8.229 g/m2.h). Based on pre-treatment test, formic acid 9% together with examined corrosion inhibitor and clay stabilizer, can be used as an alternative to regular HCl 15% for stimulation purpose where more areas will be covered that previously left unreachable by regular acid 15%. In addition, potentially more effective squeezed scale inhibitor using organic acid can also be achieved by performing further experiments. The method presented in this paper for pre-treatment experimental studies of organic acid can provide engineers with intensive guide to meet the best result of organic acid treatment.


2021 ◽  
Author(s):  
Khidir Mansum Ibragimov ◽  
Nahide Ismat Huseinova ◽  
Aliabas Alipasha Gadzhiev

Abstract For controlling the oil field development proposed an economically efficient express calculation and visualization method of the hydrodynamic parameters current values distribution in the productive formation. The presented report shows the results of applying this technique for determining the injected water propagation direction into the productive formation (X horizon) at the «Neft Dashlary» field. Based on the calculated results, the current distribution of the injected water was visualized in the selected section of the formation. High accuracy of the calculation was confirmed by comparing obtained results with the results of a simultaneous tracer study conducted in the field conditions. During tracer studies it was tested a new tracer material, more effective than its analogs. According to laboratory and experimental studies, the addition of 0.003% of this indicator substance to the volume of injected water is the optimal amount for its recognition in the well's product. At the allocated area of the "Neft Dashlari" field, the benefits from the use of the calculation method amounted to 62.9 thousand manats. Based on the obtained satisfying results of the new method for calculating hydrodynamic parameters and the use of a tracer indicator application at the «Neft Dashlary» oilfield, it is recommended to apply these developments in other oil and gas fields for mass diagnostic of the reservoir fluid distribution in a selected area of productive formations.


2021 ◽  
Vol 2021 ◽  
pp. 164-170
Author(s):  
H.K. Güler ◽  
F.C. Çallıoğlu

In this study, it was achieved that crosslinking of PVP/GEL nanofibers with two-steps. Crosslinking is a process highly important for water-soluble polymers in terms of application areas and mechanical properties. Firstly, crosslinking of PVP polymers experimental studies were carried out via heat treatment at different temperatures and times. Then, GEL polymers were crosslinked with GTA vapour at different times. Morphological analysis was carried out via SEM images and chemical characteristics were determined via FT-IR analysis. Moreover, after the crosslinking process, SD and WL values were calculated. All results showed that before crosslinking of SEM images, nanofibers were smooth, fine and without beads. The average fiber diameter is 196 nm and the fiber diameter distribution is quite uniform. After crosslinking of SEM images, it is expected that all nanowebs will turn from fibrous surfaces to membranous. Generally, SD and WL values decrease with crosslinking time increase. According to all of the SEM images, SD and WL values, optimum conditions were determined for PVP as 4 hours at 180oC and for GEL as 24 hours. Lastly, the presence of PVP and GEL polymers in the nanofiber structure was verified chemically with FT-IR analysis.


2021 ◽  
Vol 2 (1(58)) ◽  
pp. 40-43
Author(s):  
Sergey Goolak ◽  
Viktor Tkachenko ◽  
Svitlana Sapronova ◽  
Oleksandr Spivak ◽  
Ievgen Riabov ◽  
...  

The object of research is a pulsating current traction motor. To improve the accuracy of its mathematical model, it is necessary to use the values of the parameters that are determined in experimental studies of the electric motor. In particular, it is important to use in the model of the electric motor inductance obtained experimentally. A method is proposed for calculating the inductance of the armature winding, main poles, additional poles and compensation winding and the total inductance of the traction motor armature circuit. The calculations are based on the results of the indirect inductance measurement method, in which the electrical values of various modes of power supply of the electric motor windings are directly measured, and the inductances are determined by auxiliary calculations. The inductances of the traction motor armature circuit have a non-linear dependence on the current flowing through them. The main difference of the study is that the measurements of the electrical parameters required for calculating the inductance are carried out over the entire range of operating currents of the windings. The essence of the proposed technique is to measure the active power in the armature winding, the winding of the main and additional poles, and the compensation winding, as well as in the armature circle as a whole when they are supplied with alternating current. According to the obtained values of active power losses and phase displacement, the corresponding reactive power losses are determined, with the help of which the inductances of the motor windings are calculated. Approbation of the methodology for calculating the conduction inductance for an electric motor of a pulsating current NB-418K6 (country of origin Russia), is used on electric locomotives of the VL80T and VL80k series (country of origin Russia). A scheme for measuring electrical parameters necessary for calculating inductance is proposed. The graphical dependences of the inductance on the armature current, built on the basis of calculations, confirmed the hypothesis about the nonlinear dependence of these inductances on the armature current. For further application of the results obtained in the simulation of the operation of the traction electric motor NB-418K6, a polynomial approximation of the total inductance of the armature circuit was performed.


2021 ◽  
Vol 15 (1) ◽  
pp. 7628-7636
Author(s):  
D. Belakhal ◽  
Kouider Rahmani ◽  
Amel Elkaroui Elkaroui ◽  
Syrine Ben Haj Ayech ◽  
Nejla Mahjoub Saïd ◽  
...  

In the current investigation, numerical study of a thermal jet of asymmetric (rectangular and elliptical) and axisymmetric (circular) geometry was investigated with variable density to verify the impact of the ratio of density and geometry on the generation of entropy. The central jet was brought to different temperatures (194, 293 and 2110 K) to obtain density ratios (0.66, 1 and 7.2) identical to a mixture jet ((Air-CO2), (Air-Air) and (Air-He)), respectively. Solving the three-dimensional numerical resolution of the Navier Stocks for turbulent flow permanent enclosed on the turbulence model K-εstandard was made. The results acquired are compared with that carried out in previous experimental studies, where it was concluded that, the axisymmetric (circular) geometry increases the entropy generation.


Author(s):  
Pablo Cesar Trejo ◽  
Jose Renato M.S. Oliveira ◽  
Márcio S.S. Almeida ◽  
Maria C.F. Almeida ◽  
Mario A. Vignoles

The development of new offshore oil and gas fields is continuously expanding to ultra-deep waters. This tendency and the necessity of reducing project costs have been stimulating the development of new technologies as well as the enhancement of floating production systems. In this regard, pipelines and flexible riser systems have been getting more attention due to its low cost of installation and operation. In order to project a pipeline system, it is important to understand the pipe-soil interaction mechanisms and quantify the influence of soil behaviour on pipe response caused by lateral movement such as thermal buckling. The loads that a pipeline is subjected have been a topic of many experimental studies that aim to reproduce those loads in a realistic manner. This present study concerns the analysis of lateral clay-pipe interaction associated with large deformations and berm formation process at the leading edge of the pipe during movement at given burial depths. A series of centrifuge tests was conducted to assess the relationship between horizontal force and lateral pipe displacement. The breakout force experimental results were compared with different literature proposals, showing a good agreement. A procedure was also proposed to evaluate the normalized lateral force through the combination of two different approaches. The results showed a good comparison with the centrifuge experimental data.


Innotrans ◽  
2021 ◽  
pp. 38-43
Author(s):  
Konstantin L. Kostyuchenko ◽  
◽  
Alexander V. Zinin ◽  
Vladimir A. Ryabov ◽  
Alexey A. Zinin ◽  
...  

The article studies the possibility of reducing the transition resistance of demountable electrical contact joints in laboratory conditions by using multicomponent gallium alloys. The relevance of the chosen topic is attributed to the need for reducing energy losses and improve the reliability of a contact network.


Sign in / Sign up

Export Citation Format

Share Document