scholarly journals The Effect of Cement Aging on the Stability of a Cement-in-Cement Revision Construct

2021 ◽  
Vol 11 (6) ◽  
pp. 2814
Author(s):  
Mareike Schonhoff ◽  
Therese Bormann ◽  
Kevin Knappe ◽  
Tobias Reiner ◽  
Linda Stange ◽  
...  

A revision surgery can be a complicated procedure. The prevention of the removal of a well-integrated cement mantle can minimize intraoperative complications. With the cement-in-cement technique, the implant will be fixated with a layer of bone cement onto the remaining cement mantle. In our experimental in vitro study, we investigated the effect of cement aging of a cement-in-cement revision construct and regular cement mantle on the bending strength. Two different types of bone cement were tested at four different stages of aging. The Palacos cement showed no significant difference in bending strength at any aging point, regardless of whether it was used primarily or as a cement-in-cement revision. In contrast, the SmartSet MV cement showed a significant difference between the primary and cement-in-cement applications depending on cement aging time. The comparison of the two cement-in-cement structures investigated showed significant differences between the manufacturers depending on the cement aging.

2018 ◽  
Vol 6 (02/03) ◽  
pp. 106-111
Author(s):  
Ramandeep Kaur ◽  
Manjit Kumar ◽  
Shailesh Jain ◽  
Neha Jindal

Abstract Statement of Problem The adhesion of impression material to impression tray is very important. Tray adhesive plays a major role in making accurate impression. Although manufactures recommend the use of particular tray adhesives, comparison of their affective adhesiveness has not been reported. The effect of use of tray adhesives on dimensional accuracy of dies has not been established. Purpose The aim of this study was to compare the dimensional accuracy of dies using different tray adhesives at different time intervals. Materials and Methods First part of study comprised 120 samples in six groups with 20 samples in each group. First group comprised samples with no tray adhesive, and in other five groups, different types of tray adhesives were applied. The dies obtained were evaluated for upper diameter, lower diameter, and occlusogingival height. In the second part, there were a total of 125 samples in five groups with 25 samples in each group. Five different types of tray adhesive were applied for five different time intervals 5, 10, 15, 20, and 25 minutes, respectively. The specimens were tested in tensile mode for its debonding force at a crosshead speed of 5 mm/min, until separation failure occurred. Results Significant difference was seen for upper and lower diameters when compared with the group without any tray adhesive. The maximum bond strength was found in the group in which tray adhesive was applied for 20 minutes.


Materials ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3205 ◽  
Author(s):  
Seen-Young Kang ◽  
Ji-Min Yu ◽  
Hyoung-Sik Kim ◽  
Jun-Seok Lee ◽  
Chan-Mi Yeon ◽  
...  

This study aims to compare the torque values for various lengths of the titanium-based orthodontic anchor screw (OAS), different anchorage methods and varying artificial bone densities after predrilling. Furthermore, the effects of these parameters on bone stability are evaluated. A total of 144 OASs were prepared with a diameter of 1.6 mm and heights of 6, 8 and 10 mm. Artificial bones were selected according to their density, corresponding to Grades 50, 40 and 30. Torque values for the automatic device and manual anchorage methods exhibited a statistically significant difference for the same-sized OAS, according to the bone density of the artificial bones (p < 0.05). However, when insertion torque was at the maximum rotations, there was no significant difference in the torque values for the Grade 30 artificial bone (p > 0.05). When the torque values of both anchorage methods were statistically compared with the mean difference for each group, the results of the manual anchorage method were significantly higher than those of the automatic device anchorage method (p < 0.05). A statistically significant difference was observed in the bone stability resulting from different OAS anchorage methods and artificial bone lengths. These findings suggest that the automatic anchorage method should be used when fixing the OAS.


Author(s):  
Aparna Dwivedi ◽  
Kavita Maru ◽  
Aakash Sharma

Introduction. The interocclusal registration materials record the occlusal relationship between the natural and /or artificial teeth for planning an occlusal rehabilitation in removable and fixed partial dentures. Aim and objectives. The aim of this in vitro study was to evaluate and compare the accuracy and the three dimensional stability offered by three different types of interocclusal recording materials at storage time intervals of 1 hour and 24 hours. Methods. Three commercially available interocclusal recording materials were used - Group I - Polyether bite registration paste (Ramitec), Group II- Polyvinylsiloxane bite registration material (Imprint), Group III- Bite registration wax (Maarc).The test was carried out using an epoxy resin model. A total of 30 samples were made with each group consisting of ten samples. Three dimensional measurements were carried out by using 3D-Coordinate measuring machine (CMM) at time intervals of 0-1 hour and 0-24 hours in X, Y and Z- axis.   Results. Twelve readings were obtained for three axes (4 readings for each sample at 1 axis) and the averages of these four values were noted for a particular axis (X/Y/Z). Statistical analysis was performed using analysis of variance (ANOVA) for comparison among the groups and then Tukey’s honestly significant difference (HSD) tests was performed for comparison among groups at the 0.05 level of significance. Conclusion. Polyvinylsiloxane was dimensionally the most stable material followed by polyether and finally bite registration wax. Dimensional accuracy and stability is influenced by both “material” and “time” factors.


Materials ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 2345 ◽  
Author(s):  
Bruna Sinjari ◽  
Gianmaria D’Addazio ◽  
Martina Bozzi ◽  
Renato Celletti ◽  
Tonino Traini ◽  
...  

The aim of this in vitro study was to evaluate the alterations of a titanium surface after treatment with two different types of ultrasonic tips: conventional steel versus an innovative copper alloy silver-plated one. Twenty smooth-surface, grade IV unalloyed titanium discs were divided into two groups. The discs were ultrasonically instrumented and the scaler was connected with a loading machine. The surface morphology was examined using scanning electron microscopy (SEM) and fractal analysis of lacunarity was calculated to highlight the alteration of the surface using the two different tips. The SEM analysis showed different degrees of surface roughness between the two types of scaler tips. Moreover, these observations demonstrated that the new tip showed fewer irregularities on the disc’s surface than the conventional steel tip. The statistical and fractal analysis showed a statistically significant difference between the two groups. Surface alterations of titanium induced by the conventional ultrasonic tips were much greater than those made by copper alloy silver plated tips. The presented results suggest that the use of this new ultrasonic tip may reduce the alterations on the implant surface during its use in dental practice.


2019 ◽  
Vol 9 (19) ◽  
pp. 4197
Author(s):  
Shahabe Saquib ◽  
AlQarni Abdullah ◽  
Das Gotam ◽  
Naqash Talib ◽  
Sibghatullah Muhammad ◽  
...  

Splinting of the mobile teeth is a critical part of periodontal management to improve the prognosis and longevity of stable results of periodontally compromised teeth with increased mobility. Different types of splints are used in the dental field based on their mechanical and physical properties.The objective of the current in vitro study was to evaluate the flexure strength and flexural modulus of different types of splinting materials, such as: composite block, ligature wire, Ribbond®, InFibra®, and F-splint-Aid® bonded utilizing Flowable composites resin material. Seventy-five bar specimens were prepared with the dimensions of 25 × 4 × 2 mm, utilizing split metallic mold. Specimens were divided equally (n = 15) into five groups (one control group, four test groups). Different layers of splinting material were placed in between the layers of composite before curing. All the specimens were subjected to a three-point bending test by using a universal testing machine to calculate the flexural strength and flexural modulus. The entire data was subjected to statistical tests to evaluate the significance. Specimens from composite block groups showed the least mean value for flexural strength (89.15 ± 9.70 MPa) and flexural modulus (4.310 ± 0.912 GPa). Whereas, the highest mean value for flexural strength (168.04 ± 45.95 MPa) and flexural modulus (5.861 ± 0.501 GPa) were recorded by Ribbond® specimens. Inter group comparison of flexural strength showed statistically significant differences (P-value < 0.05), whereas comparison of flexural modulus showed non-significant difference among the groups (P-value > 0.05). Within the limitation of the present study, it was concluded that the Ribbond® exhibits maximum flexural strength and flexural modulus, whereas the composite blocks recorded the least values. Still, the decision making depends on the clinical scenario and the unique characteristic of each splint material.


Author(s):  
Arda Ozdiler ◽  
suleyman dayan ◽  
Burc Gencel ◽  
Gulbahar Isık-Ozkol

This in vitro study evaluated the influence of taper angles on the internal conical connections of implant systems and of the application of chlorhexidine gel as an antibacterial agent or a polyvinyl siloxane (PVS) sealant on the reverse torque values of abutment screws after dynamic loading. The current study tested four implant systems with different taper angles (5.4°, 12°, 45°, and 60°). Specimens were divided into three groups: control (neither chlorhexidine gel filled nor silicone sealed), 2% chlorhexidine gel-filled or silicone-sealed group, and group subjected to a dynamic load of 50 N at 1 Hz for 500,000 cycles prior to reverse torque measurements. Quantitative positive correlation was observed between the taper angle degree and the percentage of tightening torque loss. However, this correlation was significant only for the 60° connection groups except in the group in which a sealant was applied ( p = 0.013 for the control group, p = 0.007 for the chlorhexidine group). Percentages of decrease in the torque values of the specimens with silicone sealant application were significantly higher compared with both the control and chlorhexidine groups ( p = 0.001, p = 0.002, p = 0.001, and p = 0.002, respectively, according to the increasing taper angles); the percentage of decrease in torque values due to chlorhexidine application was statistically insignificant when compared with the control group. The application of gel-form chlorhexidine as an antibacterial agent does not significantly affect the stability of the implant–abutment connection under dynamic loads. PVS sealants may cause screw loosening under functional loads.


Author(s):  
Rathika Rai ◽  
M. A. Easwaran ◽  
K. T. Dhivya

Aim: To evaluate the surface detail reproduction of dental stone this is immersed in different disinfectant solution and studied under stereomicroscope. Methodology: Total number of 30 specimens of dental stone (Type III) were made with measurements of 1.5cm diameter and 1cm height .This samples are divided in to 3 groups group A,B,C. were A is immersed in Distilled water which was taken as control group ;B is immersed in 2% Glutaraldehyde and C is immersed in 5%sodium hypochlorite. Each specimen were immersed in the disinfectant solution for 15 minutes and dried under room temperature for 24 hrs. After 24 hrs each specimens are studied under stereomicroscope for surface details. Result: The results showed no significant difference in the surface irregularities and porosities for a group 1 and group 2 except group 3 which showed significant increase in the porosities, surface irregularities and erosions after disinfection with 5% NaHOCl by immersion method. Conclusion: The surface detail reproduction capacity of die stone was adversely affected when 5% Sodium hypochlorite was used as disinfectant solution when compare d to control group and 2% Glutaraldehyde


Polymers ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 1660
Author(s):  
Sevda Mihailova Yantcheva

The development of composite materials is subject to the desire to overcome polymerization shrinkage and generated polymerization stress. An indicator characterizing the properties of restorative materials, with specific importance for preventing secondary caries, is the integrity and durability of marginal sealing. It is a reflection of the effects of polymerization shrinkage and generated stress. The present study aimed to evaluate and correlate marginal integrity and micropermeability in second-class cavities restored with three different types of composites, representing different strategies to reduce polymerization shrinkage and stress: nanocomposite, silorane, and bulk-fill composite after a ten-month ageing period. Thirty standardized class ΙΙ cavities were prepared on extracted human molars. Gingival margins were 1 mm apical to the cementoenamel junction. Cavities were randomly divided into three groups, based on the composites used: FiltekUltimate-nanocomposite; Filtek Silorane LS-silorane; SonicFill-bulk-fill composite. All specimens were subjected to thermal cycles after that, dipped in saline for 10-mounds. After ageing, samples were immersed in a 2% methylene blue. Thus prepared, they were covered directly with gold and analyzed on SEM for assessment of marginal seal. When the SEM analysis was completed, the teeth were included into epoxy blocks and cut longitudinally on three slices for each cavity. An assessment of microleakage on stereomicroscope followed. Results were statistically analyzed. For marginal seal evaluation: F.Ultimate and F.Silorane differ statistically with more excellent results than SonicFill for marginal adaptation to the gingival margin, located entirely in the dentin. For microleakage evaluation: F.Ultimate and F.Silorane differ statistically with less microleakage than SonicFill. Based on the results obtained: a strong correlation is found between excellent results for marginal adaptation to the marginal gingival ridge and micropermeability at the direction to the axial wall. We observe a more significant influence of time at the gingival margin of the cavities. There is a significant increase in the presence of marginal fissures (p = 0.001). A significant impact of time (p < 0.000) and of the material (p < 0.000) was found in the analysis of the microleakage.


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


2002 ◽  
Vol 28 (1) ◽  
pp. 95-99 ◽  
Author(s):  
Carole Burillon ◽  
Laurent Kodjikian ◽  
Gérard Pellon ◽  
Annie Martra ◽  
Jean Freney ◽  
...  