scholarly journals Economic Analysis for Residential Solar PV Systems Based on Different Demand Charge Tariffs

Energies ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 3271 ◽  
Author(s):  
Milad Zeraatpisheh ◽  
Reza Arababadi ◽  
Mohsen Saffari Pour

It is well known that the use of photovoltaic (PV) systems helps to preserve the environment, produce lower levels of greenhouse gases (GHGs), and reduce global warming, however, whether it is economically profitable for customers or not is highly debatable. This paper aims to address this issue. To be comprehensive, three different types of buildings are considered as case studies. Then, these three buildings are modeled in EnergyPlus to determine the rate of energy consumption. Afterward, comparisons of various solar system sizes based on economic parameters such as the internal rate of return, the net present value, payback period and profitability indexing for various-sized PV systems are carried out. The results show that by the demand charge tariffs, using PV systems has no economic justification. It has been shown that even with neglecting further costs of the PV system like maintenance, by demand charge tariffs, it is not economically beneficial for customers to use the PV systems. Profitability index of all three buildings with various PV power systems is between 0.2 to 0.8, which are by no means is desirable. Moreover, it was found that bigger solar systems are less cost-effective in the presence of demand charges.

Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3360
Author(s):  
Tefera Mekonnen ◽  
Ramchandra Bhandari ◽  
Venkata Ramayya

Currently, difficulties such as the depletion of fossil fuel resources and the associated environmental pollution have driven the rise of other energy systems based on green energy sources. In this research, modeling and a viability study of grid-connected and islanded photovoltaic (PV) power systems for supplying the residential load in Mekelle City, Ethiopia, were carried out considering the country’s emerging utility tariff plan for 2021 and beyond. The technical viability of the proposed supply option was analyzed using PVGIS, PVWatts and HOMER Pro tool, while the economic and environmental optimization aspects were carried out using HOMER Pro. Sensitivity analyses and output comparisons among the three renewable energy simulation tools are presented. The results showed that under the consideration of an incremental electricity tariff plan (up to 2021), the analyzed cost of energy of the grid/PV system is around 12% lower than the utility grid tariff. Moreover, we also found that by taking the continuous global solar PV cost reduction into account, the cost of energy of the modeled islanded operation of solar PV power units totally broke the grid tariff in Ethiopia after 2029 based on the tariff for 2021 and well before with the expected escalation of the grid tariff on an annual basis. The technical performance of the system realized through PVGIS and PVWatts was almost comparable to the HOMER Pro outputs. Thus, this investigation will offer a clear direction to the concerned target groups and policy developers in the evolution of PV power supply options throughout the technically viable locations in the country.


2019 ◽  
Vol 8 (1) ◽  
pp. 34-52 ◽  
Author(s):  
M. Asif ◽  
Mohammad A. Hassanain ◽  
Kh Md Nahiduzzaman ◽  
Haitham Sawalha

Purpose The Kingdom of Saudi Arabia (KSA) is facing a rapid growth in energy demand mainly because of factors like burgeoning population, economic growth, modernization and infrastructure development. It is estimated that between 2000 and 2017 the power consumption has increased from 120 to 315 TWh. The building sector has an important role in this respect as it accounts for around 80 percent of the total electricity consumption. The situation is imposing significant energy, environmental and economic challenges for the country. To tackle these problems and curtail its dependence on oil-based energy infrastructure, KSA is aiming to develop 9.5 GW of renewable energy projects by 2030. The campus of the King Fahd University of Petroleum and Minerals (KFUPM) has been considered as a case study. In the wake of recently announced net-metering policy, the purpose of this paper is to investigate the prospects of rooftop application of PV in buildings. ArcGIS and PVsyst software have been used to determine the rooftop area and undertake PV system modeling respectively. Performance of PV system has been investigated for both horizontal and tilted installations. The study also investigates the economic feasibility of the PV application with the help of various economic parameters such as benefit cost ratio, simple payback period (SPP) and equity payback periods. An environmental analysis has also been carried out with the help of RETScreen software to determine the savings in greenhouse gas emissions as a result of PV system. Design/methodology/approach This study examines the buildings of the university campus for utilizable rooftop areas for PV application. Various types of structural, architectural and utilities-related features affecting the use of building roofs for PV have been investigated to determine the corrected area. To optimize the performance of the PV system as well as space utilization, modeling has been carried out for both horizontal and tilted applications of panels. Detailed economic and environmental assessments of the rooftop PV systems have also been investigated in detail. Modern software tools such as PVsyst, ArcGIS and RETScreen have also been used for system design calculations. Findings Saudi Arabia is embarking on a massive solar energy program as it plans to have over 200 GW of installed capacity by 2030. With solar energy being the most abundant of the available renewable resource for the country, PV is going to be one of the main technologies in achieving the set targets. The country has, however, unlike global trends, traditionally overlooked the small-scale and building-related application of solar PV, focusing mainly on larger projects. This study explores the prospects of utilization of solar PV on building roofs. Building rooftops are constrained in terms of PV application owing to wide ranging obstacles that can be classified into five types – structural, services, accessibility, maintenance and others. The total building rooftop area in the study zone, calculated through ArcGIS has been found to be 857,408 m2 of which 352,244 m2 is being used as car parking and hence is not available for PV application. The available roof area, 505,165 m2 is further hampered by construction and utilities related features including staircases, HVAC systems, skylights, water tanks and satellite dish antennas. Taking into account the relevant obstructive features, the net rooftop area covered by PV panels has been found to be in the range 25–41 percent depending upon the building typology, with residential buildings offering the least. To optimize both the system efficiency and space utilization, PV modeling has been carried out with the help of PVsyst software for both the tilted and horizontal installations. In terms of output, PV panels with tilt angle of 24° have been found to be 9 percent more efficient compared to the horizontally installed ones. Modeling results provide a net annual output 37,750 and 46,050 MWh from 21.44 and 28.51 MW of tilted and horizontal application of PV panels, sufficient to respectively meet 16 and 20 percent of the total campus electricity requirements. Findings of the economic analysis reveal the average SPP for horizontal and tilted applications of the PV to be 9.2 and 8.4 years, respectively. The benefit cost ratio for different types of buildings for horizontal and tilted application has been found to be ranging between 0.89 and 2.08 and 0.83 and 2.15, respectively. As electricity tariff in Saudi Arabia has been increased this year by as much as 45 percent and there are plans to remove $54bn of subsidy by 2020, the cost effectiveness of PV systems will be greatly helped. Application of PV in buildings can significantly improve their environmental performance as the findings of this study reveal that the annual greenhouse gas emission in the KFUPM campus can be reduced by as much as 40,199 tons carbon dioxide equivalent. Originality/value The PV application on building roof especially from economic perspective is an area which has not been addressed thus far. Khan et al. (2017) studied the power generation potential for PV application on residential buildings in KSA. Asif (2016) also investigated power output potential of PV system in different types of buildings. Dehwas et al. (2018) adopted a detailed approach to determine utilizability of PV on residential building roofs. None of these studies have covered the economics of PV systems. This study attempts to address the gap and contribute to the scholarship on the subject. It targets to determine the power output from different types of building in an urban environment by taking into account building roof conditions. It also provides detailed economic assessment of PV systems. Subsequent environmental savings are also calculated.


Energies ◽  
2018 ◽  
Vol 11 (7) ◽  
pp. 1853 ◽  
Author(s):  
Aldo Barrueto Guzmán ◽  
Rodrigo Barraza Vicencio ◽  
Jorge Ardila-Rey ◽  
Eduardo Núñez Ahumada ◽  
Arturo González Araya ◽  
...  

In the last five years, the Chilean Ministries of Agriculture and Energy developed a national strategy to incorporate renewable energies into various economic sectors. Since 2013, more than 1500 off-grid solar photovoltaic (PV) systems, with power ranging from 1 kW to 3 kW, were installed to drive existing irrigation systems in small and medium-sized farms for the exportation of fresh fruit. A net billing regulation was also implemented in 2014. This study shows a cost-effective methodology for the sizing of solar PV systems for existing irrigation facilities in Chile, in an effort to improve the competitiveness of the fresh-fruit industry. The same methodology may also be implemented in other Latin American countries. The article presents the analysis of four projects (two in the Atacama Region, and two in the Maule Region). The baseline situation of the four units was studied, as well as the energy-efficient actions that may be applied, in addition to the recommended characteristics of the selected PV system to drive the irrigation systems of small fresh-fruit farms. Off-grid and on-grid solar PV systems were analyzed, including some particularities of the Chilean regulations. The required water demand of the irrigation systems and their corresponding pressure heads were also determined. The electricity demand of the system was calculated, and the PV system was designed for an optimal irrigation system. Additionally, an economical assessment was made for two years. In the first year, the cost effectiveness of energy-efficient actions was evaluated for the irrigation system, and it was found that they had paybacks of approximately two years. In the second year, the implementation of a PV system in each demonstrative unit was evaluated. The on-grid solar PV system performed better than the off-grid system, with evaluated paybacks of approximately 12 years. Finally, some recommendations for a well-designed on-grid solar PV system were made on the basis of it lasting over 25 years, with an adequate operation and maintenance plan.


Electronics ◽  
2021 ◽  
Vol 10 (9) ◽  
pp. 1121
Author(s):  
Kamran Ali Khan Niazi ◽  
Yongheng Yang ◽  
Tamas Kerekes ◽  
Dezso Sera

A reconfiguration technique using a switched-capacitor (SC)-based voltage equalizer differential power processing (DPP) concept is proposed in this paper for photovoltaic (PV) systems at a cell/subpanel/panel-level. The proposed active diffusion charge redistribution (ADCR) architecture increases the energy yield during mismatch and adds a voltage boosting capability to the PV system under no mismatch by connected the available PV cells/panels in series. The technique performs a reconfiguration by measuring the PV cell/panel voltages and their irradiances. The power balancing is achieved by charge redistribution through SC under mismatch conditions, e.g., partial shading. Moreover, PV cells/panels remain in series under no mismatch. Overall, this paper analyzes, simulates, and evaluates the effectiveness of the proposed DPP architecture through a simulation-based model prepared in PSIM. Additionally, the effectiveness is also demonstrated by comparing it with existing conventional DPP and traditional bypass diode architecture.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4150
Author(s):  
Lluís Monjo ◽  
Luis Sainz ◽  
Juan José Mesas ◽  
Joaquín Pedra

Photovoltaic (PV) power systems are increasingly being used as renewable power generation sources. Quasi-Z-source inverters (qZSI) are a recent, high-potential technology that can be used to integrate PV power systems into AC networks. Simultaneously, concerns regarding the stability of PV power systems are increasing. Converters reduce the damping of grid-connected converter systems, leading to instability. Several studies have analyzed the stability and dynamics of qZSI, although the characterization of qZSI-PV system dynamics in order to study transient interactions and stability has not yet been properly completed. This paper contributes a small-signal, state-space-averaged model of qZSI-PV systems in order to study these issues. The model is also applied to investigate the stability of PV power systems by analyzing the influence of system parameters. Moreover, solutions to mitigate the instabilities are proposed and the stability is verified using PSCAD time domain simulations.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Ramhari Poudyal ◽  
Pavel Loskot ◽  
Ranjan Parajuli

AbstractThis study investigates the techno-economic feasibility of installing a 3-kilowatt-peak (kWp) photovoltaic (PV) system in Kathmandu, Nepal. The study also analyses the importance of scaling up the share of solar energy to contribute to the country's overall energy generation mix. The technical viability of the designed PV system is assessed using PVsyst and Meteonorm simulation software. The performance indicators adopted in our study are the electric energy output, performance ratio, and the economic returns including the levelised cost and the net present value of energy production. The key parameters used in simulations are site-specific meteorological data, solar irradiance, PV capacity factor, and the price of electricity. The achieved PV system efficiency and the performance ratio are 17% and 84%, respectively. The demand–supply gap has been estimated assuming the load profile of a typical household in Kathmandu under the enhanced use of electric appliances. Our results show that the 3-kWp PV system can generate 100% of electricity consumed by a typical residential household in Kathmandu. The calculated levelised cost of energy for the PV system considered is 0.06 $/kWh, and the corresponding rate of investment is 87%. The payback period is estimated to be 8.6 years. The installation of the designed solar PV system could save 10.33 tons of CO2 emission over its lifetime. Overall, the PV systems with 3 kWp capacity appear to be a viable solution to secure a sufficient amount of electricity for most households in Kathmandu city.


Author(s):  
Rakesh Dalal ◽  
Kamal Bansal ◽  
Sapan Thapar

Rooftop solar photovoltaic(PV) installation in India have increased in last decade because of the flat 40 percent subsidy extended for rooftop solar PV systems (3 kWp and below) by the Indian government under the solar rooftop scheme. From the residential building owner's perspective, solar PV is competitive when it can produce electricity at a cost less than or equal grid electricity price, a condition referred as “grid parity”. For assessing grid parity of 3 kWp and 2 kWp residential solar PV system, 15 states capital and 19 major cities were considered  for the RET screen simulation by using solar isolation, utility grid tariff, system cost and other economic parameters. 3 kWp and 2 kWp rooftop solar PV with and without subsidy scenarios were considered for simulation using RETscreen software. We estimate that without subsidy no state could achieve grid parity for 2kWp rooftop solar PV plant. However with 3 kWp rooftop solar PV plant only 5 states could achieve grid parity without subsidy and with government subsidy number of states increased to 7, yet wide spread parity for residential rooftop solar PV is still not achieved. We find that high installation costs, subsidized utility grid supply to low energy consumer and financing rates are major barriers to grid parity.


2014 ◽  
Vol 60 (4) ◽  
pp. 315-320 ◽  
Author(s):  
Gustaw Mazurek

Abstract Estimation of Global Tilted Irradiation (GTI) is a key to performance assessment of typical solar systems since they usually employ tilted photovoltaic (PV) modules or collectors. Numerous solar radiation databases can deliver irradiation values both on horizontal and tilted plane, however they are validated mostly with horizontal-plane ground measurements. In this paper we have compared GTI estimates retrieved from five Internet databases with results of measurements at two PV systems located in Poland. Our work shows that in spite of good agreement in annual scale, there is a tendency to underestimate GTI in summer and overestimate in winter, when PV modules can receive less than a half of expected irradiation. The latter issue affects sizing of PV system components and implies a correction needed to achieve all-year long operation.


Author(s):  
Mohammad Omar Abdullah ◽  
Voon Chun Yung ◽  
Audra Anak Jom ◽  
Alvin Yeo Wee ◽  
Martin Anyi ◽  
...  

The eBario project has won the eAsia Award and the Mondialogo Engineering Award in 2004 and 2005 respectively for it’s successful implementation of an Information and Telecommunications Technology Center (ICT) and solar renewable energy-incentive rural community project at the Bario Highland of Sarawak, East Malaysia, Borneo (http://www.unimas.my/ebario/). Although solar photovoltaic (PV) energy has been opted for power generation at the ICT Telecenter for the past five years, there is still a need to investigate the cost-effectiveness of the current energy setup as well as to conduct sustainability study taking into account factors such as system efficiency, weather, costs of fuel, operating costs, as well as to explore the feasibility of implementing alternative energy resources for the rural ICT Telecenter. Recent theoretical study conducted has shown that renewable combined power systems are more sustainable in terms of supplying electricity to the ICT Telecenter, and in a more cost-effective way compared to a standalone PV system which is subject to the cloud and the recent dense haze problems. For that purpose, two combined power systems are being put into consideration namely PV-Hydro and PV-Hydro-Fuel Cell, where the total simulated annualized cost for these two system configurations are US$10,847 and US$76,010 respectively as far as the present location is concerned. The PVHydro-Fuel Cell produces electrical energy at the amount of 3,577 kWh/yr while the annual energy consumption is 3,203 kWhr/yr. On the other hand, PV-Hydro produces 3,789 kWhr/yr of electricity annually load which consumes energy at 3,209 kWhr/yr. Results thus obtained has shown that the PVHydro scheme is expected to have advantages over the existing PV standalone system. Firstly, it is more cost-effective. Secondly, it provides the best outcomes for the local indigenous community and the natural highland environments both for now and the future. Thirdly, it also able to relate the continuity of both economic and social aspects of the local society as a whole. As the combined PV-Hydro system had been chosen, plus for completeness purposes, the present paper also discussed the custom design and construction of a small waterwheel breast-shot hydro-generator, suited to the local location and existing water energy resources. Energy saving design calculations and Sankey diagram showing the energy flows for the new combined system are also given herein. Finally, the energy system performance equations and the performance curves introduced in this study provide a new simple method of evaluating renewable energy systems.


2018 ◽  
Vol 8 (4) ◽  
pp. 3168-3171
Author(s):  
F. Mavromatakis ◽  
G. Viskadouros ◽  
H. Haritaki ◽  
G. Xanthos

The latest measure for the development of photovoltaics in Greece utilizes the net-metering scheme. Under this scheme the energy produced by a PV system may be either consumed by the local loads or be injected to the grid. The final cost reported in an electricity bill depends upon the energy produced by the PV system, the energy absorbed from the grid and the energy injected to the grid. Consequently, the actual electricity consumption profile is important to estimate the benefit from the use of this renewable energy source. The state latest statistics in Greece for households reveal that the typical electrical consumption is 3750 kWh while 10244 kWh are consumed in the form of thermal energy. We adopt in our calculations the above amount of electrical energy but assume four different scenarios. These different hourly profiles are examined to study the effects of synchronization upon the final cost of energy. The above scenarios are applied to areas in different climate zones in Greece (Heraklion, Athens and Thessaloniki) to examine the dependence of the hourly profiles and the solar potential upon the financial data with respect to internal rate of return, payback times, net present value and the levelized cost of energy. These parameters are affected by the initial system cost and the financial parameters.


Sign in / Sign up

Export Citation Format

Share Document