scholarly journals A Neural Network for Monitoring and Characterization of Buildings with Environmental Quality Management, Part 1: Verification under Steady State Conditions

Energies ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 3469 ◽  
Author(s):  
Marek Dudzik ◽  
Anna Romanska-Zapala ◽  
Mark Bomberg

Introducing integrated, automatic control to buildings operating with the environmental quality management (EQM) system, we found that existing energy models are not suitable for use in integrated control systems as they poorly represent the real time, interacting, and transient effects that occur under field conditions. We needed another high-precision estimator for energy efficiency and indoor environment and to this end we examined artificial neural networks (ANNs). This paper presents a road map for design and evaluation of ANN-based estimators of the given performance aspect in a complex interacting environment. It demonstrates that in creating a precise representation of a mathematical relationship one must evaluate the stability and fitness under randomly changing initial conditions. It also shows that ANN systems designed in this manner may have a high precision in characterizing the response of the building exposed to the variable outdoor climatic conditions. The absolute value of the relative errors ( M a x A R E ) being less than 1.4% for each stage of the ANN development proves that our objective of monitoring and EQM characterization can be reached.

2019 ◽  
Vol 282 ◽  
pp. 02068
Author(s):  
Anna Romanska-Zapala ◽  
Mark Bomberg

The concept of environmental quality management has been described in papers [1 - 4] that looked at the next generation of low energy buildings from the point of view of the occupant. Optimizing energy use is difficult for a few reasons: presence of dramatic changes in the manner we design and operate buildings, change in the role of an architect who must be a leader of interacting team, often quality management is biased towards the design more than on performance of the finished product and finally the need for integrated monitoring and modeling in the occupancy stage. Effectively, we are integrating heating/cooling and ventilation with the structure at the same time as we verify the appropriateness of the new methods to evaluate performance of these systems. In this process we require double controls, one by the occupant and the other by the computerized (smart) control system. The traditional approaches to modify human behavior generally failed because occupants were not given enough control over their environment. Thus, a major part of the trend to a low-carbon, climate resilient future will be focused on methodology to include path from a complex field testing of building performance to simplified testing that combined with simple monitoring and data from utilities would allow assessment of the energy and carbon emission in a district of a city. Our experience shows that preliminary design must be optimized during the period of service for all more complex buildings such as large residential, office or commercial buildings. In this context the artificial neural network approach appears to have significant advantages. Yet, traditionally ANN requires large data set to establish functional relations during the learning stage and therefore the first question is how precise can the control of temperature be when the heat exchanger is subjected to different climatic conditions.


2004 ◽  
Vol 155 (7) ◽  
pp. 284-289 ◽  
Author(s):  
Pietro Stanga ◽  
Niklaus Zbinden

The retrospective study based on aerial photos (1971–2001) of the Canton Tessin made it possible to measure and analyze the evolution of the vegetation of eleven Alpine zones. The analysis shows a strong expansion of the arborescent vegetation and, at the same time, a decrease in other forms of ground cover (bush, shrub, meadow and unproductive spaces). Analysis of the data gives rise to the conjecture that the strong evolutionary dynamism evidenced by the areas under investigation is a result of the vast clearings carried out in past centuries to create pastures. Following the subsequent decrease in human pressure, nature today is attempting to rebalance the level of the biomass. These processes manifest themselves in different ways and with various intensity, depending on the interaction of numerous factors (e.g. climatic conditions, site fertility, initial conditions, evolution of anthropological pressure, etc.).


2021 ◽  
Author(s):  
Syed Abdul Rehman Khan ◽  
Danish Iqbal Godil ◽  
Muhammad Umer Quddoos ◽  
Zhang Yu ◽  
Muhammad Hanif Akhtar ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4388
Author(s):  
Esmail Mahmoudi Saber ◽  
Issa Chaer ◽  
Aaron Gillich ◽  
Bukola Grace Ekpeti

Natural ventilation is gaining more attention from architects and engineers as an alternative way of cooling and ventilating indoor spaces. Based on building types, it could save between 13 and 40% of the building cooling energy use. However, this needs to be implemented and operated with a well-designed and integrated control system to avoid triggering discomfort for occupants. This paper seeks to review, discuss, and contribute to existing knowledge on the application of control systems and optimisation theories of naturally ventilated buildings to produce the best performance. The study finally presents an outstanding theoretical context and practical implementation for researchers seeking to explore the use of intelligent controls for optimal output in the pursuit to help solve intricate control problems in the building industry and suggests advanced control systems such as fuzzy logic control as an effective control strategy for an integrated control of ventilation, heating and cooling systems.


2006 ◽  
Vol 50 (01) ◽  
pp. 63-84
Author(s):  
Young-Woo Lee ◽  
Leigh McCue ◽  
Michael Obar ◽  
Armin Troesch

The dynamics and hydrodynamics of ship capsizing include strong nonlinearities, transient effects, and physical phenomena that have not been fully identified or studied. This paper presents a study of some of the various mechanisms associated with this extreme behavior. A quasi-nonlinear three degree of freedom numerical model is employed to examine the effects of initial conditions on the ultimate state of a box barge model. The numerical results are then used to provide structure and understanding to otherwise seemingly inconsistent and ambiguous experiments.


IEEE Access ◽  
2018 ◽  
Vol 6 ◽  
pp. 57324-57333 ◽  
Author(s):  
Siguang Chen ◽  
Jiasheng Zhou ◽  
Xiaoyao Zheng ◽  
Xiukai Ruan

2020 ◽  
Vol 9 (3) ◽  
pp. 443
Author(s):  
Saeed Hussein Alhmoud ◽  
Çiğdem Çağnan ◽  
Enis Faik Arcan

As the wave of sustainability is sweeping across the major countries and cities of the world, the effect of the inevitable change is finding its way through to the health sector as well. Since the main functions of the hospital include healing the patient, it aims to provide adequate health services to people. Hospitals managers should strive to realize facilities that meet a certain level of demand. This study aims to present the interior environmental quality (IEQ) of bedrooms in Jordanian hospitals and propose a solution to improve indoor environment quality using sustainable design principles. A qualitative research methodology is used in this study. A comparative analysis is made between the original set up of the hospital buildings and the present conditions in which they are in. During the research, it was found that the design to be applied for a hospital should be following the healing environmental characteristics. Besides, the design of hospitals should be made with the climatic conditions of the area in mind. In the advanced countries of the world, hospitals are generally built with extensive research and important factors such as temperature, wind direction and humidity are taken into consideration. The design for a hospital building should be assessed according to the German Green Building Assessment (DGNB) criteria. It has been found that the one-bedroom is ideal for patients because it provides the necessary privacy and also greatly reduces the spread of the disease. In hygienic practices, there should be a first-class healing environment with evidence-based medical research. It was concluded that the practices involving the use of sustainable designs can be followed with the hints received from hospitals in the advanced countries of the world. Keywords: Jordan hospital; IEQ; bedroom; interior design; healthcare; green building assessment; DGNB


Vestnik MGSU ◽  
2021 ◽  
pp. 486-492
Author(s):  
Oleg D. Samarin

Introduction. It is noted that the improvement of the technology for calculating the thermal regime of premises in the conditions of automation of climate systems is still relevant. The aim of the work is to find a universal dependence of the air temperature in the building premises on time in conditions of a jump in heat access or heat loss for the integral law of regulating the compensatory heat flow from microclimate systems. In the form of a scientific hypothesis, we consider the statement about the power nature of such a dependence with the presence of a maximum and an asymptotic tendency to zero. Materials and methods. The study involves the use of basic equations that relate the most significant components of heat flows in rooms serviced by microclimate systems equipped with integrated controllers under conditions of abrupt changes in thermal disturbances. The method of dimension analysis is used to identify dimensionless complexes that are essential for obtaining engineering dependencies, as well as software calculation of sums of infinite series with a given accuracy, numerical solution of nonlinear equations, and the method of power series economization. Results. An analytical expression is found for changes in room temperature under integrated control of climate equipment under conditions of a jump in heat availability, which has the form of an infinite series in degrees of a dimensionless parameter that characterizes the properties of the room and the automation system. A simplified expression for the deviation of air temperature is obtained and a formula for the required control time is derived, as well as its estimation is given on the example of one residential building in the climatic conditions of Moscow. Conclusions. It is shown that the dependence of the air temperature in a room serviced by microclimate systems with integrated controllers on time is represented in a universal dimensionless form, suitable for any objects regardless of their specific characteristics. The previously discovered relationships for the moment of maximum deviation and the value of the dynamic control error depending on the air exchange of the room, the transmission coefficient of the controller and the room’s own heat stability are confirmed and refined.


Sign in / Sign up

Export Citation Format

Share Document