scholarly journals Effects of Artificial Tooth Brushing and Hydrothermal Aging on the Mechanical Properties and Color Stability of Dental 3D Printed and CAD/CAM Materials

Materials ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6207
Author(s):  
Na-Eun Nam ◽  
Seung-Ho Shin ◽  
Jung-Hwa Lim ◽  
June-Sung Shim ◽  
Jong-Eun Kim

This study analyzed the surface roughness and waviness, Vickers hardness (VHN), and color changes of six types of 3D printed resins and computer-aided design/computer-aided manufacturing (CAD/CAM) materials after artificial toothbrushing. The average surface roughness height (Ra) change of Formlabs denture teeth A2 resin (FMLB) was not significant between after artificial toothbrushing (0.17 ± 0.02 μm and 0.17 ± 0.05 μm, respectively; mean ± standard deviation). However, the Ra value increased significantly in all remaining groups. Regarding waviness, polymethylmethacrylate (PMMA) had the largest increases in average waviness height (Wa) and maximum surface waviness height (Wz) between, before (0.43 ± 0.23 μm and 0.08 ± 0.02 μm), and after (8.67 ± 4.03 μm, 1.30 ± 0.58 μm) toothbrushing. There were no significant changes in Wa for Formlabs denture teeth A2 resin (FMLB) and NextDent C&B (NXT). After artificial toothbrushing, the dispersed-filler composite (DFC) group had the largest color difference (ΔE, of 2.4 ± 0.9), and the remaining materials had smaller changes than the clinical acceptance threshold of ΔE = 2.25. The VHN of FMLB and NXT were 9.1 ± 0.4 and 15.5 ± 0.4, respectively, and were not affected by artificial toothbrushing. The flexural strengths of the 3D printed materials were 139.4 ± 40.5 MPa and 163.9 ± 14.0 MPa for FMLB and NXT, respectively, which were similar to those of the polycarbonate and PMMA groups (155.2 ± 23.6 MPa and 108.0 ± 8.1 MPa, respectively). This study found that the evaluated 3D printed materials had mechanical and optical properties comparable to those of CAD/CAM materials and were stable even after artificial toothbrushing and hydrothermal aging.

Materials ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 5359
Author(s):  
Ji-Won Shin ◽  
Jong-Eun Kim ◽  
Young-Jin Choi ◽  
Seung-Ho Shin ◽  
Na-Eun Nam ◽  
...  

Recent advances in three-dimensional (3D) printing have introduced new materials that can be utilized for dental restorations. Nonetheless, there are limited studies on the color stability of restorations using 3D-printed crowns and bridge resins. Herein, the color stability of conventional computer-aided design/computer-aided manufacturing (CAD/CAM) blocks and 3D-printing resins was evaluated and assessed for their degrees of discoloration based on material type, colorant types (grape juice, coffee, curry, and distilled water (control group)), and storage duration (2, 7, and 30 days) in the colorants. Water sorption, solubility, and scanning electron microscope (SEM) analyses were conducted. A three-way ANOVA analysis showed that all three factors significantly affected the color change of the materials. Notably, the discoloration (ΔE00) was significantly higher in all 3D printing resins (4.74–22.85 over the 30 days) than in CAD/CAM blocks (0.64–4.12 over the 30 days) following immersion in all colorants. 3D-printing resins showed color differences above the clinical limit (2.25) following storage for 7 days or longer in all experimental groups. Curry was the most prominent colorant, and discoloration increased in almost all groups as the storage duration increased. This study suggests that discoloration must be considered when using 3D printing resins for restorations.


Author(s):  
Bilge ERSÖZ ◽  
Serpil Karaoğlanoğlu ◽  
Elif Aybala Oktay ◽  
Numan Aydın

Purpose: This study investigated discoloration and surface roughness (Ra) of resin-based computer aided design (CAD)/computer aided manufacturing (CAM) blocks and direct and indirect resin composites after staining with coffee. Materials & Methods: Using a Teflon mold, 60 disc shaped specimens (8×2 mm2) were fabricated from direct (Estelite Asteria and GrandioSO) and indirect (Gradia Plus) resin composites, and 30 resin CAD/CAM specimens (12×14×2 mm3) were prepared from resin composite CAD/CAM blocks (Vita Enamic, Brilliant Crios, and Cerasmart) (n=10). A contact type profilometer was used to determine the Ra of all 60 polished samples. All specimens were thermocycled between 5 and 55°C for 3000 cycles, and immersed in coffee solution (37°C) for 1 and 7 days. A spectrophotometer was used to determine the color change (∆E00) with the CIEDE2000 formula after the specimens were re-polished. One-way analysis of variance (ANOVA) and Tukey multiple comparison test was performed to analyze the data (p<0.05). Results: The lowest degree of discoloration among the materials tested was found in Vita Enamic resin CAD/CAM block (p<0.001), whereas the highest degree of discoloration was found in the Gradia Plus indirect composite (p<0.001). There was no significant difference was seen between the initial surface roughness values (Ra) among the groups (p=0.249). No significant improvement was observed in the color of the groups except for the Cerasmart resin block after after polishing. Conclusion: Direct resin composites have a higher discoloration potential over resin-based CAD/CAM blocks, whereas they are less prone to discoloration than indirect resin composites


2022 ◽  
Author(s):  
eaeldwakhly not provided

This study was conducted to assess the surface characteristics in terms of roughness of two CAD/CAM (Computer-Aided-Design/Computer-Aided Manufacturing)restorative material spre and post chewing simulation exposure. Methods: Specimens were prepared from two CAD/CAM ceramic materials: Cerec Blocs C and IPS e-max ZirCAD. A total of 10 disks were prepared for each study group. 3D optical noncontact surface profiler was used to test the surface roughness (ContourGT, Bruker, Campbell, CA, USA). A silicone mold was used to fix the individual samples using a self-curing resin. Surface roughness (SR) was examined pre and post exposure to chewing simulation. 480,000 simulated chewing cycles were conducted to mimic roughly two years of intraoral clinical service. The results data was first tested for normality and equal variance (Levene’s test >0.05) then examined with paired and independent sample t-test at a significance level of (p < 0.05). Results:The two CAD-CAM materials tested exhibited increased surface roughness from baseline. The highest mean surface roughness was observed in Cerec blocs C group after chewing simulation (2.34 µm± 0.62 µm). Whereas the lowest surface roughness was observed in IPS e.max ZirCAD group before chewing simulation (0.42 µm± 0.16 µm). Both study groups exhibited significantly different surface roughness values (p< 0.05). There was a statistically higher surface roughness values after the chewing simulation in Cerec blocs C when compared to IPS e.max ZirCAD groups (p = 0.000).Conclusion:Even though both tested CAD/CAM materials differ in recorded surface roughness values, results were within clinically accepted values.


2021 ◽  
Author(s):  
CA Jurado ◽  
A Tsujimoto ◽  
H Watanabe ◽  
NG Fischer ◽  
JA Hasslen ◽  
...  

SUMMARY Objective: The purpose of this study was to evaluate the effectiveness of five different polishing systems on a computer-aided design and computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic-network restoration with nanoscale assessment using atomic force microscopy (AFM) and visual assessment performed by dental school senior students and faculty members. Method: Forty-eight full coverage crowns were milled out of polymer-infiltrated ceramic-network CAD/CAM blocks (Vita Enamic) for polishing with one company proprietary, two ceramic and two composite polishing systems. The prepared crowns were divided into six groups: (1) no polishing (control); (2) polishing with Vita Enamic Polishing Kit (VEna); (3) polishing with Shofu Porcelain Laminate Polishing Kit (SCer); (4) polishing with Brasseler Dialite Feather lite All- Ceramic Adjusting & Polishing System (BCer); (5) polishing with Shofu Composite Polishing Kit (SCom); and (6) polishing with Brasseler Composite Polishing Kit (BCom). The polished crown surface topography was observed, and surface roughness and area were measured with AFM. In addition, polished crowns were visually assessed by 15 senior dental students and 15 dental school faculty members. Results: All polishing treatments significantly reduced the surface roughness and area of the crown compared with the control. SCom and BCom showed significantly higher surface area than VEna, and the SCer and BCer groups were intermediate, showing no significant difference from either VEna or SCom and BCom. There were no significant differences in surface roughness between any of the systems. Dental students and faculty members classified the groups polished with VEna, SCer, and BCer groups as clinically acceptable, and they selected BCer group as the best polished restorations and the control group as the least polished restorations. Conclusions: Ceramic and composite polishing systems produced similar polishing results as that observed using a company proprietary polishing system. However, effectiveness for polishing using a company proprietary and ceramic polishing system tends to be higher than composite polishing systems.


2021 ◽  
Author(s):  
RG Fonseca ◽  
RC Peńa ◽  
R Simóes ◽  
AC Ramos ◽  
LN Dovigo

SUMMARY Little is known about the impact of bleaching on the optical properties of computer-aided design and computer-aided manufactured (CAD-CAM) monolithic materials. The aim of the present study was to evaluate the effect of one session of in-office bleaching on stain removal, staining susceptibility, translucency, and whiteness variations of CADCAM monolithic materials. Disks were fabricated from Lava Ultimate (LU), Vita Enamic (VE), Vita Suprinity (VS), and IPS e.max CAD (IPS). A spectrophotometer was used to register Commission Internationale de l’Eclairage L*a*b* coordinates. For stain removal, 80 specimens from each material were assessed at baseline (R0) and after immersion in deionized water or coffee for 365 days followed or not by bleaching with 40% hydrogen peroxide (R1). For staining susceptibility, 80 specimens from each material were analyzed at baseline (R0’), and after having been bleached or not and immersed in deionized water or coffee (R1’). Both analyses were calculated as the color difference (ΔE00) between R1-R0 and R1’-R0’, respectively. Differences in translucency (ΔTP00) and whiteness (ΔWID) between R1-R0 and R1’-R0’ were also calculated. Data were analyzed by three-way ANOVA and the Games-Howell post hoc test (α=0.05). Clinical significance was based on 50%:50% perceptibility and acceptability thresholds for ΔE00, ΔTP00 and ΔWID, respectively. Surfaces were analyzed by scanning electron microscopy. Coffee increased ΔE00 in LU, VE, and VS, and decreased their translucency and whiteness, whereas the IPS had only its whiteness affected. Bleaching after immersion in coffee decreased ΔE00 in LU and VE, and increased translucency and whiteness of LU, VE, and VS. No effect was observed on IPS. Bleaching before immersion in coffee decreased translucency of LU, but within the acceptable interval, while VE exhibited lower ΔE00, and became more translucent and less dark. Both VS and IPS were not affected. One session of in-office bleaching benefited optical properties of the previously stained LU, VE, and VS, without increasing their susceptibility to staining or adversely providing clinically unacceptable variations in their translucency and whiteness. All variations exhibited by the IPS were below the perceptible threshold.


Materials ◽  
2019 ◽  
Vol 12 (14) ◽  
pp. 2252 ◽  
Author(s):  
Yin ◽  
Jang ◽  
Lee ◽  
Bae

This study compares the mechanical properties and wear ability of five CAD/CAM (computer-aided design/computer-aided manufacturing) millable dental blocks. All the discs, including Amber Mill Hybrid, Vita Enamic, Katana Avencia, Lava Ultimate, and Amber Mill, were cut in dimensions of 1.2 mm in thickness and 12 mm in diameter, polished to a machined surface, and immersed in distilled water for seven days. Vickers hardness was measured and the indentations were observed using microscope. The discs were brushed under a 150 g load. Mean surface roughness (Ra) and topography were determined after 100,000 cycles. Finally the biaxial flexure strength of the discs was measured and the broken surfaces were observed using scanning electron microscopy (SEM). The data was subjected to Weibull analysis. All data were analyzed by one-way analysis (ANOVA). The results of Vickers hardness are shown as: Amber Mill > Vita Enamic > Amber Mill Hybrid > Lava Ultimate > Katana Avencia. Katana Avencia showed the highest volume percentage reduction and the roughest surface after toothbrushing. The biaxial flexural strength is shown as: Amber Mill > Katana Avencia > Lava Ultimate > Amber Mill Hybrid > Vita Enamic. All the tested materials exhibited varying degrees of mass loss and surface roughness. The properties of the composite materials are related to the filler content, filler volume, and polymerization methods.


2021 ◽  
Vol 9 (11) ◽  
pp. 486-497
Author(s):  
Mohamed A. Abuheikal ◽  
◽  
Sherihan M. Eissa ◽  
Hisham S. El Gabry ◽  
◽  
...  

Background: Computer-aided design and computer-aided manufacturing (CAD-CAM) techniques have lately become a popular treatment option for complete dentures fabrication. The two principal CAD-CAM techniques milling and 3D printing used in complete dentures construction have been approved and documented in showing clinically good results. Surface characteristics of dentures fabricated by these new techniques have a great effect on microbiological adherence to denture fitting surfaces. Aim: As other clinical trials and/or in-vitro studies evaluating the microbiological effect and its correlation with the surface roughness of the two advanced manufacturing techniques and comparing it with the conventional technique are lacking. Thus, this study aimed to further assess the microbiological and surface properties of different widely used denture base materials. Methodology: Thirty-six completely edentulous patients were selected and divided randomly into three groups Group I patients received conventional complete denture, Group II patients received CAD/CAM milled complete dentures and Group III patients received 3D printed complete dentures. All denture`s surface roughness were evaluated, also all patients were recalled after 3, 9 & 12 months respectively to evaluate the microbiological adherence. Results: Microbiological count significantly increased (P < 0.05) after 12 months in all groups, after 12 months there was a significant difference (P < 0.05) between three groups as group II (Milled) was significantly the lowest, then the group I (conventional), while group III (3D printed) was significantly the highest. Regarding surface roughness of group II (milled) was significantly the lowest, while group III (3D printed) was significantly the highest. Finally, there was a strong positive significant correlation between microbiological adherence and surface roughness in all groups as (r > 0.5). Conclusion: Group II (Milled) appeared to be the best regarding microbiological adherence and surface roughness followed by the group I (conventional) and finally group III (3D printed). Furthermore, it was evident that surface roughness has a great effect on microbiological adherence regardless of the fabrication technique utilized.


2019 ◽  
Vol 9 (12) ◽  
pp. 1745-1750
Author(s):  
Laila Al Deeb ◽  
Khold Al Ahdal ◽  
Ghaith Alotaibi ◽  
Abdullah Alshehri ◽  
Bader Alotaibi ◽  
...  

The aim was to investigate the marginal fit, internal adaptation and compressive strength of SLA provisionals (SLA) in comparison to CAD-CAM and conventional (CONV) interim fixed partial dentures (FPDs). Thirty interim FPDs were fabricated using CAD-CAM technology (CAD-CAM blocks Ceramill TEMP, PMMA), conventional molding technique (CONV) (TrimPlus, PMMA) and Stereolithography (SLA) method (Form 2, Formlabs, PMMA) (n = 10). Internal adaptation (occlusal, coronal, middle and cervical) and marginal integrity (inner and outer edge) was assessed using micro-computerized tomography (Micro-CT). The failure and compressive strength was assessed by application of a static load at a crosshead speed of 1 mm/min until fracture. Data was analysed using ANOVA and multiple comparisons test. The maximum and minimum marginal mis-fit was for CONV (283.3± 98.6 nm) and CAD-CAM (68.2± 18.1 m) groups. CAD-CAM (68.2± 18.1 m) and SLA (84.7± 27.5 m) provisionals showed comparable marginal mis-fit (p > 0.05). The mean failure load was significantly higher (p < 0.05) in CAD-CAM (687.86± 46.72 N), compared to SLA (534.8± 46.1 N) and CONV (492.7± 61.8 N) samples. Compressive strength for CAD-CAM (2.44± 0.27 MPa) samples was significantly higher (p < 0.05) than SLA (1.80± 0.15 MPa) and CONV (1.65± 0.20 MPa) groups. Marginal fit and internal adaptation of SLA printed FPDs was comparable to CAD-CAM interims. Compressive strength of the SLA interims FPDs can withstand intra-oral loads.


Prosthesis ◽  
2020 ◽  
Vol 2 (4) ◽  
pp. 325-332
Author(s):  
Kelly M. Suralik ◽  
Jie Sun ◽  
Chia-Yu Chen ◽  
Sang J. Lee

There has been an increase in utilizing 3D printers in dental restorations. The purpose of the study is to compare mechanical properties of 3D-printed prostheses to those of self-cured and/or computer-aided design-computer-aided manufacturing (CAD-CAM) restorations. A metal master typodont was prepared for the mandibular left sextant with implant analogs embedded at the first premolar and first molar positions with a missing second premolar. Three-unit provisional fixed dental prosthesis (FDP) was designed utilizing the 3Shape tooth library and forty-five uniform specimens were fabricated with different materials: self-cured poly(methyl methacrylate) (PMMA) (N = 15), milled PMMA CAD-CAM blocks (N = 15) and 3D-printed resin (N = 15). All specimens were tested using an Instron machine at a crosshead speed of 0.5 mm/min by an axial load on the occlusal surface of the second premolar pontic site. Statistical analysis was completed with Shapiro-Wilk, ANOVA and Tukey post-hoc tests. Mean fracture force was 300.61 N, 294.64 N and 408.49 N for self-cured PMMA, milled PMMA and 3D-printed resin, respectively. Mean force at FDP fracture of 3D-printed resin was significantly greater than the mean fracture force of either self-cured (p = 0.016, 95% CI [17.86, 197.91]) or milled (p = 0.010, 95% CI [23.83, 203.88]) PMMA.


Medicina ◽  
2020 ◽  
Vol 56 (5) ◽  
pp. 234
Author(s):  
Mohammed M. Al Moaleem ◽  
Rashad AlSanosy ◽  
Nasser M. Al Ahmari ◽  
Mansoor Shariff ◽  
Abdulkhaliq A. Alshadidi ◽  
...  

Background and Objectives: Khat chewing is considered as a daily habit that is practiced by more than five million people globally. The effect of khat chewing on the surface roughness and the color stability of natural teeth and the material used in the fabrication of dental prosthesis remains unknown. This study was conducted to explore and compare the effect of khat homogenate (KH) on the surface roughness (Ra) and the average color changes (ΔE*) amongst natural teeth and selected shades from different porcelain types, namely, feldspathic metal ceramic (MC) VM13, computer-aided design/computer assisted manufacture (CAD/CAM) feldspathic (Vitablocs Mark II), and multilayer zirconia (Ceramill Zolid PS) porcelains. Materials and Methods: Seventy samples were prepared from natural teeth, feldspathic MC, CAD/CAM Vitablocs Mark II, and zirconia porcelain. The Ra values were measured using a profilometer and expressed in micrometers, whereas the ΔE* values were measured using VITA Easyshade® V spectrophotometer for all samples before and after frequent immersion and thermocycling in KH for 30 days. The surface topography was used to assess the materials surfaces (glazed or polished) after KH immersion by using a white light interferometry machine. Results: Results revealed that the Ra and the ΔE* values of the different types of tested porcelain were influenced by KH. The order of surface roughness values was glazed or polished MC > polished Zircon > polished Vitablocs Mark II > natural teeth. The lowest ΔE* values were recorded for glazed Vitablocs Mark II and MC, and the values could be arranged as polished zircon > natural teeth > glazed zircon > polished MC > polished Vitablocs Mark II. P values were significantly varied (<0.001) among all the tested groups, except the zircon group (>0.05) for both Ra and ΔE*. Conclusions: KH significantly affected both surface parameter and color of glazed or polished porcelain materials and natural teeth.


Sign in / Sign up

Export Citation Format

Share Document