scholarly journals Scalable Preparation of Low-Defect Graphene by Urea-Assisted Liquid-Phase Shear Exfoliation of Graphite and Its Application in Doxorubicin Analysis

Nanomaterials ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 267 ◽  
Author(s):  
Chang-Seuk Lee ◽  
Su Jin Shim ◽  
Tae Hyun Kim

The mass production of graphene is of great interest for commercialization and industrial applications. Here, we demonstrate that high-quality graphene nanosheets can be produced in large quantities by liquid-phase shear exfoliation under ambient conditions in organic solvents, such as 1-methyl-2-pyrrolidinone (NMP), with the assistance of urea as a stabilizer. We can achieve low-defect graphene (LDG) using this approach, which is relatively simple and easily available, thereby rendering it to be an efficient route for the mass production of graphene. We also demonstrate the electrochemical sensing of an LDG-modified electrode for the determination of doxorubicin (DOX). The sensor shows an enhanced electrocatalytic property towards DOX, leading to a high sensitivity (7.23 × 10−1 μM/μA) with a detection limit of 39.3 nM (S/N = 3).

2019 ◽  
Vol 97 (2) ◽  
pp. 140-146
Author(s):  
Tian Gan ◽  
Zhikai Wang ◽  
Mengru Chen ◽  
Wanqiu Fu ◽  
Haibo Wang ◽  
...  

In this work, the Ag@Cu particles with yolk–shell nanostructure was prepared by facile solvothermal method, which was modified on glassy carbon electrode (GCE) to fabricate electrochemical sensor for the convenient and fast determination of p-aminobenzoic acid (PABA). The surface morphology and electrochemical properties of the as-prepared Ag@Cu nanocomposite modified electrode were characterized by scanning electron microscopy, transmission electron microscopy, chronocoulometry, and electrochemical impedance spectroscopy. Further, the electrochemical sensing of PABA was performed on the Ag@Cu/GCE using cyclic voltammetry and differential pulse voltammetry techniques, showing high catalytic activity. Under the optimal conditions, the sensor exhibited a wide linear range, high sensitivity, and low detection limit of 0.315 μmol/L for PABA. The developed sensor was also successfully applied for PABA detection in anesthetic and cosmetics with satisfactory results.


2008 ◽  
Vol 130 (6) ◽  
Author(s):  
M. Fernandino ◽  
T. Ytrehus

Stratified flows are encountered in many industrial applications. The determination of the flow characteristics is essential for the prediction of pressure drop and holdup in the system. The aim of this study is to gain insight into the interaction of a gas and a liquid phase flowing in a stratified regime, with especial focus on the effect of interfacial waves on the turbulence structure of the liquid phase. Measurements of mean velocities and turbulent intensities in the liquid phase of a stratified air-water duct flow are performed. Mean velocity profiles and turbulence structure are affected differently for different wave amplitudes. The effect of small amplitude waves is restricted to the near-interface region, resembling the effect of increasing shear rate on a flat interface. On the other hand, large amplitude waves modify the flow structure throughout the whole liquid depth. The mean velocity is greatly enhanced, resulting in a higher bulk velocity. Turbulent intensities are also significantly enhanced especially in the interface region. This big difference in flow structure is not observed after the appearance of the first waves but rather when a certain critical wave amplitude is triggered, indicating that the prediction of this critical wave type turns out to be more important than the determination of the transition from a smooth to a stratified wavy regime.


2011 ◽  
Vol 64 (3) ◽  
pp. 684-692 ◽  
Author(s):  
Chinagarn Kunacheva ◽  
Shuhei Tanaka ◽  
Shigeo Fujii ◽  
Suwanna Kitpati Boontanon ◽  
Chanatip Musirat ◽  
...  

Perfluorinated compounds (PFCs), especially perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA), are fully fluorinated organic compounds, which have been used in many industrial applications. These chemicals have contaminated surface water all over the world even in developing countries like Thailand. The previous study showed the contamination in Chao Phraya River in 2006 and 2007. The purposes of this field study were to determine the solid and liquid phase of PFCs contamination in Chao Phraya River and to compare the changes of PFC concentration in 2008. Surveys were conducted in the lower reach of Chao Phraya River in the industrialized area. A solid phase extraction (SPE) coupled with HPLC-ESI-MS/MS were used for the analysis for ten PFCs. Ten PFCs were analyzed to identify the contamination in both solid and liquid phases. PFCs were detected in both the solid and liquid phase in every sample. PFOA was the most dominant PFC while PFPA and PFOS were also highly detected in most samples. The average loadings of PFPA, PFOA and PFOS in Chao Phraya River were 94.3, 284.6 and 93.4 g/d, respectively. PFOS concentrations did not show differences between 2006 and 2008. However, PFOA concentrations were higher in 2008/5/26, while comparing other samplings. The ratio of solid : liquid PFPA (2.1 : 1.0) [(ng/g)/(ng/L)] was lower than PFOA (13.9 : 1.0) [(ng/g)/(ng/L)] and PFOS (17.6 : 1.0) [(ng/g)/(ng/L)]. The shorter chain (more hydrophilic) PFC was better to dissolve in water rather than adsorb onto suspended solids. PFOS also showed more potential to attach in the suspended solids than PFOA.


2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
Abd-Elgawad Radi ◽  
Nadia Abd El-Ghany ◽  
Tarek Wahdan

A novel electrochemical sensing approach, based on electropolymerization of a molecularly imprinted polypyrrole (MIPpy) film onto a glassy carbon electrode (GCE) surface, was developed for the detection of flunixin (FXN). The sensing conditions and the performance of the constructed sensor were assessed by cyclic, differential pulse and (DPV) square wave voltammetry (SWV). The sensor exhibited high sensitivity, with linear responses in the range of 5.0 to 50.0 µM with detection limits of 1.5 and 1.0 µM for DPV and SWV, respectively. In addition, the sensor showed high selectivity towards FXN in comparison to other interferents. The sensor was successfully utilized for the direct determination of FXN in buffalo raw milk samples.


2019 ◽  
Vol 85 (2) ◽  
pp. 12-16
Author(s):  
I. V. Saunina ◽  
E. N. Gribanov ◽  
E. R. Oskotskaya

The sorption of Hg (II), Cd (II), and As (III) by natural aluminosilicate is studied. It is shown that the mineral absorbs those toxicants in a rather wide pH range, quantitative extraction of analytes being achieved in a neutral or close to neutral medium (pH values range within 7.0 - 8.0; 6.3 - 7.5; 7.4 - 8.5 for Hg (II), As (III), and Cd (II), respectively). The effect of the time of phase contact on the degree of extraction of elements is shown. The sorption capacity of the mineral in optimal conditions of the medium acidity (0.06 mmol/g for mercury, 0.31 mmol/g for cadmium, and 0.52 mmol/g for arsenic) is determined. The distribution coefficients attain values of aboutnX 103-nX 104. A new combined method for determination of Hg (II), Cd (II), and As (III) in natural and waste water is developed and tested. The method consists in a preliminary group sorption concentration of the analytes by aluminosilicate, desorption of the analytes from the surface of the mineral and their subsequent atomic absorption determination. The correctness of the method is verified in analysis of spiked samples. The method is easy to use and exhibits high sensitivity, reproducibility and accuracy of analyte determination. The relative standard deviation does not exceed 0.13. Economic availability and possibility of using domestic sorption materials are the important advantages of the proposed procedure which can be used in the practice of laboratories monitoring the quality and safety of environmental objects.


2020 ◽  
Vol 23 (10) ◽  
pp. 1010-1022
Author(s):  
Emrah Dural

Aim and scope: Due to the serious toxicological risks and their widespread use, quantitative determination of phthalates in cosmetic products have importance for public health. The aim of this study was to develop a validated simple, rapid and reliable high-performance liquid chromatography (HPLC) method for the determination of phthalates which are; dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP), di-n-butyl phthalate (DBP), di(2- ethylhexyl) phthalate (DEHP), in cosmetic products and to investigate these phthalate (PHT) levels in 48 cosmetic products marketing in Sivas, Turkey. Materials and Methods: Separation was achieved by a reverse-phase ACE-5 C18 column (4.6 x 250 mm, 5.0 μm). As the mobile phase, 5 mM KH2PO4 and acetonitrile were used gradiently at 1.5 ml min-1. All PHT esters were detected at 230 nm and the run time was taking 21 minutes. Results: This method showed the high sensitivity value the limit of quantification (LOQ) values for which are below 0.64 μg mL-1 of all phthalates. Method linearity was ≥0.999 (r2). Accuracy and precision values of all phthalates were calculated between (-6.5) and 6.6 (RE%) and ≤6.2 (RSD%), respectively. Average recovery was between 94.8% and 99.6%. Forty-eight samples used for both babies and adults were successfully analyzed by the developed method. Results have shown that, DMP (340.7 μg mL-1 ±323.7), DEP (1852.1 μg mL-1 ± 2192.0), and DBP (691.3 μg mL-1 ± 1378.5) were used highly in nail polish, fragrance and cream products, respectively. Conclusion: Phthalate esters, which are mostly detected in the content of fragrance, cream and nail polish products and our research in general, are DEP (1852.1 μg mL-1 ± 2192.0), DBP (691.3 μg mL-1 ± 1378.5) and DMP (340.7 μg mL-1 ±323.7), respectively. Phthalates were found in the content of all 48 cosmetic products examined, and the most detected phthalates in general average were DEP (581.7 μg mL-1 + 1405.2) with a rate of 79.2%. The unexpectedly high phthalate content in the examined cosmetic products revealed a great risk of these products on human health. The developed method is a simple, sensitive, reliable and economical alternative for the determination of phthalates in the content of cosmetic products, it can be used to identify phthalate esters in different products after some modifications.


2019 ◽  
Vol 20 (5) ◽  
pp. 390-400 ◽  
Author(s):  
Nabil N. AL-Hashimi ◽  
Amjad H. El-Sheikh ◽  
Rania F. Qawariq ◽  
Majed H. Shtaiwi ◽  
Rowan AlEjielat

Background: The efficient analytical method for the analysis of nonsteroidal antiinflammatory drugs (NSAIDs) in a biological fluid is important for determining the toxicological aspects of such long-term used therapies. Methods: In the present work, multi-walled carbon nanotubes reinforced into a hollow fiber by chitosan sol-gel assisted-solid/ liquid phase microextraction (MWCNTs-HF-CA-SPME) method followed by the high-performance liquid chromatography-diode array detection (HPLC–DAD) was developed for the determination of three NSAIDs, ketoprofen, diclofenac, and ibuprofen in human urine samples. MWCNTs with various dimensions were characterized by various analytical techniques. The extraction device was prepared by immobilizing the MWCNTs in the pores of 2.5 cm microtube via chitosan sol-gel assisted technology while the lumen of the microtube was filled with few microliters of 1-octanol with two ends sealed. The extraction device was operated by direct immersion in the sample solution. Results: The main factors influencing the extraction efficiency of the selected NSAIDs have been examined. The method showed good linearity R2 ≥ 0.997 with RSDs from 1.1 to 12.3%. The limits of detection (LODs) were 2.633, 2.035 and 2.386 µg L-1, for ketoprofen, diclofenac, and ibuprofen, respectively. The developed method demonstrated a satisfactory result for the determination of selected drugs in patient urine samples and comparable results against reference methods. Conclusion: The method is simple, sensitive and can be considered as an alternative for clinical laboratory analysis of selected drugs.


Sign in / Sign up

Export Citation Format

Share Document