scholarly journals Oxygen Imaging for Non-Invasive Metastasis Detection

Sensors ◽  
2021 ◽  
Vol 22 (1) ◽  
pp. 237
Author(s):  
Joshua Punnoose ◽  
Henry Nachman ◽  
Shai Ashkenazi

Sentinel lymph node (SLN) biopsy is an integral part of treatment planning for a variety of cancers as it evaluates whether a tumor has metastasized, an event that significantly reduces survival probability. However, this invasive procedure is associated with patient morbidity, and misses small metastatic deposits, resulting in the removal of additional nodes for tumors with high metastatic probability despite a negative SLN biopsy. To prevent this over-treatment and its associated morbidities for patients that were truly negative, we propose a tissue oxygen imaging method called Photoacoustic Lifetime Imaging (PALI) as an alternative or supplementary tool for SLN biopsy. As the hyper-metabolic state of cancer cells significantly depresses tissue oxygenation compared to normal tissue even for small metastatic deposits, we hypothesize that PALI can sensitively and specifically detect metastases. Before this hypothesis is tested, however, PALI’s maximum imaging depth must be evaluated to determine the cancer types for which it is best suited. To evaluate imaging depth, we developed and simulated a phantom composed of tubing in a tissue-mimicking, optically scattering liquid. Our simulation and experimental results both show that PALI’s maximum imaging depth is 16 mm. As most lymph nodes are deeper than 16 mm, ways to improve imaging depth, such as directly delivering light to the node using penetrating optical fibers, must be explored.

2016 ◽  
Vol 16 (3) ◽  
pp. 22-31
Author(s):  
A Kozarova ◽  
E Minarikova ◽  
T Pappova

Abstract High-frequency skin ultrasonography using Dermascan C, manufactured by Cortex Technology, is an important part of modern diagnostic procedure of various skin diseases. It has been used in dermatology since 1979, when it was first used for the measurement of cutaneous thickness. Ultrasonography is a universal, painless, low-risk and non-invasive procedure that can easily be performed and repeated. It provides real-time visual information about the processes in the skin. This technique has grown to become frequent imaging method in dermatology. Skin ultrasonography is usually applied in the assessment of skin tumours, inflammatory or fibrosing skin diseases. The main application of ultrasonography in dermatovenerology is a preoperative thickness measurement of malignant melanoma. There is an excellent correlation between ultrasonographic and histological measurements of melanomas thickness. Moreover, information about the lesion quality and the inner structure can be obtained. In this article authors present the possibility of using high-frequency 20 MHz ultrasonography in dermatovenerology.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 977.1-977
Author(s):  
A. Potapova ◽  
O. Egorova ◽  
O. Alekseeva ◽  
A. Volkov ◽  
S. Radenska-Lopovok

Background:Ultrasound (US) is a non-invasive and safe imaging method that allows in vivo differentiation of the morphological structures of subcutaneous fat (SCF) tissue in in normal and pathology.Objectives:Reveal features of ultrasound changes in SCF in panniculitis (Pn).Methods:57 patients (f – 45, m - 12) aged 18 - 67 years with an initial diagnosis of erythema nodosum and a disease duration of 3.6 ± 1.4 years were examined. In addition to the general clinical examination, a computed tomography of the chest organs and a pathomorphological examination of a skin biopsy from the site of the node were performed. Ultrasound was performed on a MyLabTwice apparatus (ESAOTE, Italy) using a multi-frequency linear transducer (10-18 MHz) with the PD technique, the parameters of which were adapted for recording low-speed flows (PRF 300-600 Hz, low filter, dynamic range - 20-40 dB), the presence of vascularization was assessed not only in the affected area, but also on the contralateral side using high-energy Doppler.Results:33 patients were diagnosed with septal Pn (SPn), 24 - lobular Pn (LPn). In all cases, the diagnosis was verified by histological examination. Ultrasound made it possible to assess the thickness, echoicity and vascularization of the SCF. In 35 patients, significant thickening of the SCF was revealed (as compared to the contralateral side), of which in 14 cases with SPn, in 21 - with LPn. Significant diffuse thickening of the SCF with the contralateral side was observed in 18 patients, incl. in 12 (66%) patients with LPn. Limited thickening was more typical for SPn (73%). A significant increase in the echoicity of the SCF was noted in all forms of Pn. A “lobular” echo pattern with an anechogenic environment was observed in 25 patients, of which 18 (72%) had LPn. An increase in vascularization compared to the contralateral side was recorded in 30 cases (SPn-17, LPn-13).Conclusion:The obtained preliminary results indicate the important role of ultrasound in assessing the depth and prevalence of the inflammatory process at Pn. To clarify the diagnostic value of this method, further studies are needed on a larger sample of patients.Disclosure of Interests:None declared


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 742
Author(s):  
Rima Hajjo ◽  
Dima A. Sabbah ◽  
Sanaa K. Bardaweel ◽  
Alexander Tropsha

The identification of reliable and non-invasive oncology biomarkers remains a main priority in healthcare. There are only a few biomarkers that have been approved as diagnostic for cancer. The most frequently used cancer biomarkers are derived from either biological materials or imaging data. Most cancer biomarkers suffer from a lack of high specificity. However, the latest advancements in machine learning (ML) and artificial intelligence (AI) have enabled the identification of highly predictive, disease-specific biomarkers. Such biomarkers can be used to diagnose cancer patients, to predict cancer prognosis, or even to predict treatment efficacy. Herein, we provide a summary of the current status of developing and applying Magnetic resonance imaging (MRI) biomarkers in cancer care. We focus on all aspects of MRI biomarkers, starting from MRI data collection, preprocessing and machine learning methods, and ending with summarizing the types of existing biomarkers and their clinical applications in different cancer types.


2019 ◽  
Vol 9 (3) ◽  
pp. 381 ◽  
Author(s):  
Lucia Arcarisi ◽  
Licia Di Pietro ◽  
Nicola Carbonaro ◽  
Alessandro Tognetti ◽  
Arti Ahluwalia ◽  
...  

Breast cancer is the most commonly diagnosed cancer in women worldwide. Although targeted screening programs using mammography have facilitated earlier detection and improved treatment has resulted in a significant reduction in mortality, some negative aspects related to cost, the availability of trained staff, the duration of the procedure, and its non-generalizability to all women must be taken into consideration. Breast palpation is a simple non-invasive procedure that can be performed by lay individuals for detecting possible malignant nodules in the breast. It is a simple test, based on the haptic perception of different stiffness between healthy and abnormal tissues. According to a survey we carried out, despite being safe and simple, breast self-examination is not carried by women because they are not confident of their ability to detect a lump. In this study, a non-invasive wearable device designed to mimic the process of breast self-examination using pressure sensing textiles and thus increase the confidence and self-awareness of women is proposed. Combined with other screening methods, the device can increase the odds of early detection for better prognosis. Here, we present the physical implementation of the device and a finite element analysis of the mechanics underlying its working principle. Characterization of the device using models of large and medium breast phantoms with rigid inclusions demonstrates that it can detect nodules in much the same way as does the human hand during breast self-examination.


1997 ◽  
Vol 12 (3) ◽  
pp. 96-99 ◽  
Author(s):  
D. Wertheim ◽  
R. Salaman ◽  
J. Melhuish ◽  
R. Williams ◽  
I. Lane ◽  
...  

Background: It has been suggested that poor healing of wounds may be associated with reduced tissue oxygenation. A non-invasive method of assessing peripheral venous oxygenation has been investigated. Method: Changes in oxyhaemoglobin (O2Hb), deoxyhaemoglobin (HHb), oxidized cytochrome aa3 (cyt aa3) and total haemoglobin (tHb) were monitored in the left lower leg of seven healthy volunteers. A short period of venous occlusion was achieved by rapidly inflating a sphygmomanometer cuff placed around the leg to 60 mmHg. The changes in O2Hb and tHb, with respect to the baseline readings, were evaluated. PSvO2 was calculated from (ΔO2Hb/ΔtHb) × 100%. Results: From 17 sets of readings on the seven volunteers the median PSvO2 calculated was 64% (range 50–86%). Conclusion: This method appears to be a simple means of evaluating PSvO2. A change in cyt aa3 was often seen associated with the venous occlusion.


2017 ◽  
Vol 38 (5) ◽  
pp. 780-792 ◽  
Author(s):  
Nobuyuki Kudomi ◽  
Yukito Maeda ◽  
Hiroyuki Yamamoto ◽  
Yuka Yamamoto ◽  
Tetsuhiro Hatakeyama ◽  
...  

CBF, OEF, and CMRO2 images can be quantitatively assessed using PET. Their image calculation requires arterial input functions, which require invasive procedure. The aim of the present study was to develop a non-invasive approach with image-derived input functions (IDIFs) using an image from an ultra-rapid O2 and C15O2 protocol. Our technique consists of using a formula to express the input using tissue curve with rate constants. For multiple tissue curves, the rate constants were estimated so as to minimize the differences of the inputs using the multiple tissue curves. The estimated rates were used to express the inputs and the mean of the estimated inputs was used as an IDIF. The method was tested in human subjects ( n = 24). The estimated IDIFs were well-reproduced against the measured ones. The difference in the calculated CBF, OEF, and CMRO2 values by the two methods was small (<10%) against the invasive method, and the values showed tight correlations ( r = 0.97). The simulation showed errors associated with the assumed parameters were less than ∼10%. Our results demonstrate that IDIFs can be reconstructed from tissue curves, suggesting the possibility of using a non-invasive technique to assess CBF, OEF, and CMRO2.


2015 ◽  
Vol 3 (2) ◽  
pp. 72 ◽  
Author(s):  
Vishnu Ravi Kumar ◽  
Gayathri Gangadharan

<p>The aim of any invasive procedure is the complete eradication and elimination of the infection and associated necrotic tissue followed by repair and regeneration of the affected tissue. In order to achieve this goal various biological products have been introduced, among which are present the platelet concentrates. Platelet concentrates with their higher concentration of platelets has been used in the field of medicine since the 1990s in the form of the first-generation concentrates-Platelet Rich Plasma, and the second generation concentrated -Platelet Rich Fibrin. Choukroun’s Platelet Rich Fibrin is one such material, which is used by itself and also as an adjunct with grafts. It has been successful as it delivers high doses of growth factors and has anti-inflammatory properties. They have been shown to be of great promise in the field of dentistry, ranging from implantology; Sinuses lift procedures, treating of endodontic and periodontal lesions to regeneration of necrotic pulp. This novel technique has the potential to revolutionize the treatment mode in dentistry and help with reducing patient morbidity. We will be further looking into the specification and implications of this material in this review.</p>


2021 ◽  
Vol 100 (10) ◽  
pp. 1115-1122
Author(s):  
Nina V. Zaitseva ◽  
Tatyana S. Ulanova ◽  
Oleg V. Dolgikh ◽  
Tatyana V. Nurislamova ◽  
Olga A. Kazakova ◽  
...  

Introduction. Nowadays there is very relevant research on the study of the characteristics of the impact on the health of workers of low levels of harmful factors (acrylonitrile) of production during long-term exposure. Aim of the study was to examine peculiarities of immunologic and genetic indices in workers under the long-term exposure to acrylonitrile in low doses. Materials and methods. Our research object was working area air (MPCw.ar.=0.5 mg/m3) and biological media (blood and exhaled air) of workers employed at industrial rubber manufacture. Acrylonitrile was determined via a non-invasive procedure in exhaled air with samples being concentrated on sorption tubes that were then analyzed with capillary gas chromatography. Blood samples were examined to determine contents of malonic dialdehyde, lymphocytes (absolute and relative activated T-lymphocytes CD3+CD25+, absolute and relative activated T-lymphocytes CD3+CD95+), cytokines (VEGF), oncomarkers (PSA), and adrenals hormones; to do that, we applied ELISA tests and flow cytometry. Results. Acrylonitrile was established to occur in working area air in concentrations varying within MPCw.ar. range (0.007-0.015 mg/m3) being 2-3 times higher than in air inside offices at the same enterprise. We obtained statistically significant linear dependence between concentrations of acrylonitrile in the air exhaled by workers (y) and their working experience (x) that was given with the following equation: y=0.00046+0.00027x. According to the results of the laboratory examination of the workers, violations of the antioxidant defense were established. Contents of malonic dialdehyde and steroid hormones including progesterone, estradiol, and hydrocortisone that were pathogenetically linked to each other were authentically up to 3.2 times higher in the test group than in the reference one (p<0.05). Risk for antioxidant protection disorders such as elevated malonic dialdehyde contents in blood plasma might occur in the test group was 1.58 times higher than in the reference one. Conclusion. We revealed certain peculiarities in polymorphism of PPARGC1A Gly482Ser rs8192678 gene, the variability of which contributes to the formation of pathology of the cardiovascular, endocrine systems, oncoproliferative states that increase the likelihood of these undesirable events.


Sign in / Sign up

Export Citation Format

Share Document