A new technology for locating very low frequency and negative signal-to-noise ratio sound sources

2021 ◽  
Vol 263 (4) ◽  
pp. 2468-2475
Author(s):  
Yazhong Lu ◽  
Sean Wu ◽  
Zeyu Yuan ◽  
Wen He

This paper presents a new technology that enables one to locate multiple sound sources with very a large dynamic range simultaneously, including very low frequency and negative signal-to-noise ration sound sources in a non-ideal environment, where there are random background noise and unknown interfering signals. In particular, spatial resolution of source localization is frequency independent. In other words, spatial resolution remains very high at very low as well as at very high frequencies. The underlying principle of this new technology is a hybrid methodology that includes a passive SODAR (nic etection nd anging), advanced signal processing and least-squares minimization. Using this technology, engineers will be able to visualize sound sources in both real time and post processing in an adversary test environment. Live videos of sound sources localization inside a crowd machine shop are shown, where there are unknown background noise, unspecified sound reflections and reverberation, and interfering signals.

Author(s):  
Antonio Ramos ◽  
Abelardo Ruiz ◽  
Enrique Riera

Ultrasonic imaging & NDE applications can greatly improve their signal-to-noise ratios (SNR) by driving each transducer (composing piezoelectric arrays) with a spike giving pulsed power of k-Watts, repetitively at a PRF = 5000 spikes/s, by using a HV capacitive-discharge generator. However very-high levels, of pulsed intensities (3-10 A) and voltages (300-700 V) must be considered for a rigorous spike modeling. Even though the consumed "average" power will be small, the intensity through each transducer achieves several amperes, so the pulsed powers delivered by each HV generator can attain levels higher than in CW high-power ultrasonic applications: e.g., up to 5 kW / spike. This is concluded here from a transient modeling of the loaded generator. Then, unforeseen phenomena rise: intense brief pulses of driving power & emitted force in transducers, and non-linearities in driver semiconductors, because their characteristic curves only include linear ranges. But fortunately, piezoelectric devices working in this intense regime do not show serious heating problems, because the average power remains being moderate. Intensity, power and voltage, driving a broadband transducer from a HV capacitive pulser, are calculated to drastically improve (in ≅ 40 dB) the ultrasonic net dynamic range available, with emitted forces ≅ 250 Newtons pp and E/R received pulses of 70 V pp.


1995 ◽  
Vol 268 (6) ◽  
pp. H2329-H2335
Author(s):  
M. W. Yang ◽  
T. B. Kuo ◽  
S. M. Lin ◽  
K. H. Chan ◽  
S. H. Chan

We communicated the application of continuous, on-line, real-time power spectral analysis of systemic arterial pressure (SAP) signals during cardiopulmonary bypass when the heart was functionally but reversibly disconnected from the blood vessels. Based on observations from 15 cases of successfully completed coronary artery bypass grafting procedures, we found that the very low (0.00-0.08 Hz), low (0.08-0.15 Hz)-, high (0.15-0.25 Hz)-, and very high (0.80-1.60 Hz) frequency components of SAP signals exhibited differential changes before, during, and after cardiopulmonary bypass. In particular, the very low-frequency component, which purportedly represents the contribution of vasomotor activity to SAP, presented only a mild decrease in power during hypothermic cardioplegia. Interestingly, the total peripheral resistance also manifested only a slight reduction during the same period. On the other hand, the low-, high-, and very high frequency components were essentially eliminated. These results unveiled an active role for the blood vessels in the maintenance of SAP during cardiopulmonary bypass, possibly as a result of a maintained vasomotor tone as reflected by the sustained very low frequency component of the SAP signals.


1997 ◽  
Vol 19 (3) ◽  
pp. 195-208 ◽  
Author(s):  
Faouzi Kallel ◽  
Jonathan Ophir

A least-squares strain estimator (LSQSE) for elastography is proposed. It is shown that with such an estimator, the signal-to-noise ratio in an elastogram ( SNRe) is significantly improved. This improvement is illustrated theoretically using a modified strain filter and experimentally using a homogeneous gel phantom. It is demonstrated that the LSQSE results in an increase of the elastographic sensitivity (smallest strain that could be detected), thereby increasing the strain dynamic range. Using simulated data, it is shown that a tradeoff exists between the improvement in SNRe and the reduction of strain contrast and spatial resolution.


2020 ◽  
Vol 240 ◽  
pp. 07004
Author(s):  
Arpit Gupta ◽  
Seow Kit Hint ◽  
Cao Shangyu ◽  
Hoe Teck Tan

Sudden ionospheric disturbances are transient changes in the ionosphere caused by enhancement in X-ray and EUV fluxes during solar flare events. The Solar Storm Radio Telescope is developed to detect Very Low Frequency (VLF) signals with frequency between 3-30 kHz transmitted from various VLF stations around the Globe. We will also be investigating different methods to reduce the background noise in the data collection. This will help to ensure an accurate hit when there is a sudden ionospheric disturbance.


Author(s):  
The Anh Nguyen Dinh ◽  
Huy Le Xuan ◽  
Tuan Anh Vu ◽  
Duong Bach Gia

This paper presents a status data transmitting system suitable for vessel monitoring. The system consists of four main parts, which are a status data module, a frequency synthesizer, a power amplifier and a horn antenna. The status data module packs information of the identification, longitude, latitude and state of the vessel into data frames. FSK/MSK/GMSK schemes were used to modulate the data. The frequency synthesizer was designed with very high stability over temperature and very low frequency tolerance. The power amplifier provides 130 W output power at S band. The impedance bandwidth of the horn antenna can be controlled using the beveling technique.


2008 ◽  
Vol 18 (1) ◽  
pp. 19-24
Author(s):  
Erin C. Schafer

Children who use cochlear implants experience significant difficulty hearing speech in the presence of background noise, such as in the classroom. To address these difficulties, audiologists often recommend frequency-modulated (FM) systems for children with cochlear implants. The purpose of this article is to examine current empirical research in the area of FM systems and cochlear implants. Discussion topics will include selecting the optimal type of FM receiver, benefits of binaural FM-system input, importance of DAI receiver-gain settings, and effects of speech-processor programming on speech recognition. FM systems significantly improve the signal-to-noise ratio at the child's ear through the use of three types of FM receivers: mounted speakers, desktop speakers, or direct-audio input (DAI). This discussion will aid audiologists in making evidence-based recommendations for children using cochlear implants and FM systems.


2009 ◽  
Vol 23 (4) ◽  
pp. 191-198 ◽  
Author(s):  
Suzannah K. Helps ◽  
Samantha J. Broyd ◽  
Christopher J. James ◽  
Anke Karl ◽  
Edmund J. S. Sonuga-Barke

Background: The default mode interference hypothesis ( Sonuga-Barke & Castellanos, 2007 ) predicts (1) the attenuation of very low frequency oscillations (VLFO; e.g., .05 Hz) in brain activity within the default mode network during the transition from rest to task, and (2) that failures to attenuate in this way will lead to an increased likelihood of periodic attention lapses that are synchronized to the VLFO pattern. Here, we tested these predictions using DC-EEG recordings within and outside of a previously identified network of electrode locations hypothesized to reflect DMN activity (i.e., S3 network; Helps et al., 2008 ). Method: 24 young adults (mean age 22.3 years; 8 male), sampled to include a wide range of ADHD symptoms, took part in a study of rest to task transitions. Two conditions were compared: 5 min of rest (eyes open) and a 10-min simple 2-choice RT task with a relatively high sampling rate (ISI 1 s). DC-EEG was recorded during both conditions, and the low-frequency spectrum was decomposed and measures of the power within specific bands extracted. Results: Shift from rest to task led to an attenuation of VLFO activity within the S3 network which was inversely associated with ADHD symptoms. RT during task also showed a VLFO signature. During task there was a small but significant degree of synchronization between EEG and RT in the VLFO band. Attenuators showed a lower degree of synchrony than nonattenuators. Discussion: The results provide some initial EEG-based support for the default mode interference hypothesis and suggest that failure to attenuate VLFO in the S3 network is associated with higher synchrony between low-frequency brain activity and RT fluctuations during a simple RT task. Although significant, the effects were small and future research should employ tasks with a higher sampling rate to increase the possibility of extracting robust and stable signals.


Sign in / Sign up

Export Citation Format

Share Document