scholarly journals INFLUENCE OF VISCOSITY MODIFYING AGENT ON SOME RHEOLOGICAL PROPERTIES, SEGREGATION RESISTANCE AND COMPRESSIVE STRENGTH OF SELF-COMPACTING CONCRETE

2013 ◽  
Vol 19 (1) ◽  
pp. 1-8 ◽  
Author(s):  
Anna M. Grabiec

Rheological properties of self-compacting concrete mixes containing a viscosity modifying agent (VMA) in their composition were studied. After preliminary studies self-compacting concrete mixes and, particularly, a fluid concrete mix prone to segregation of its ingredients were chosen. VMA was added in various amounts to that concrete mix to check how it performed in fresh and hardened concrete. Main studies focused on the influence of VMA on the following properties of concrete mixes: the slump flow, the flow time into the diameter of 500 mm and the resistance to segregation in the vertical direction. Moreover, the air content of concrete mixes and the 28-day compressive strength of concrete were measured. Test results showed that VMA significantly influenced the rheological properties of concrete mix, stabilised it and reduced the segregation. It was proved, that the concrete mix modified by VMA used in the optimal amount, featured the smallest scatter of concrete strength results. Besides, the Tukey's test showed that a reduction of the concrete compressive strength is possible to be statistically insignificant when compared to the reference level.

1997 ◽  
Vol 1575 (1) ◽  
pp. 92-101
Author(s):  
Richard K. Smutzer ◽  
Sedat Gulen ◽  
Youlanda K. Belew ◽  
Virgil L. Anderson

The Indiana Department of Transportation is involved in preparing statistically sound specifications for strong and durable concrete used in quality assurance programs. Previous laboratory studies relating concrete strength to air content and concrete mix designs dealt with variation in compressive strength. This study searched for a statistically sound relationship between air content, concrete mix designs, and flexural strength. This study also developed a high-pressure method of hardened concrete air content determination. Sixty-four independent batches (combinations) of concrete were produced, each batch was subjected to a total of 24 tests—4 plastic and 20 hardened. The design factors were aggregate type and gradation, plastic air content, cement, and pozzolanic content and testing operator. After plastic testing, three flexural strength beams were cast from each batch of concrete. The experimental design response variables consisted of flexural, compressive, and split tensile strength along with pulse velocity. Analysis of variances, indicated that the optimum flexural strength could be obtained using as-received stone course aggregate and an air content of between 6 percent and 7.9 percent, with no fly ash. A high-pressure air meter, similar to the meter developed by the Army Corps of Engineers, was used. A strong statistical correlation of determination, r2 = 0.94, was obtained between plastic and the hardened concrete air content using this meter.


2018 ◽  
Vol 149 ◽  
pp. 01054
Author(s):  
Nadia Tebbal ◽  
Zine El Abidine Rahmouni ◽  
Lamis Rabiaa Chadi

The objective of this study is to analyze the effect of the air entrainment on the fresh rheological properties as well as on the compressive mechanical resistances of the mortars. The hardened concrete contains a certain amount of randomly spread air, coming either from a drive during kneading or from the evaporation of the mixing water. The air quantity is in the order of 20 l / m3, ie 2% of the volume. However, the presence of a large volume of air bubbles causes the mechanical resistances to fall in compression. On the other hand, the use of air entrainment could improve the rheological properties of fresh concrete. Experimental studies have been carried out to study the effect of air entrainment on compressive strength, density and ingredients of fresh concrete mix. During all the study, water cement ratio (w/c) was maintained constant at 0.5. The results have shown substantial decreasing in water and mortar density followed with decreasing in compressive strength of mortar. The results of this study has given more promising to use it as a guide for mortar mix design to choose the most appropriate concrete mix design economically.


2019 ◽  
Vol 9 (23) ◽  
pp. 5109 ◽  
Author(s):  
Miguel C. S. Nepomuceno ◽  
Luís F. A. Bernardo

Self-compacting concrete (SCC) shows to have some specificities when compared to normal vibrated concrete (NVC), namely higher cement paste dosage and smaller volume of coarse aggregates. In addition, the maximum size of coarse aggregates is also reduced in SCC to prevent blocking effect. Such specificities are likely to affect the results of non-destructive tests when compared to those obtained in NVC with similar compressive strength and materials. This study evaluates the applicability of some non-destructive tests to estimate the compressive strength of SCC. Selected tests included the ultrasonic pulse velocity test (PUNDIT), the surface hardness test (Schmidt rebound hammer type N), the pull-out test (Lok-test), and the concrete maturity test (COMA-meter). Seven sets of SCC specimens were produced in the laboratory from a single mixture and subjected to standard curing. The tests were applied at different ages, namely: 1, 2, 3, 7, 14, 28, and 94 days. The concrete compressive strength ranged from 45 MPa (at 24 h) to 97 MPa (at 94 days). Correlations were established between the non-destructive test results and the concrete compressive strength. A test variability analysis was performed and the 95% confidence limits for the obtained correlations were computed. The obtained results for SCC showed good correlations between the concrete compressive strength and the non-destructive tests results, although some differences exist when compared to the correlations obtained for NVC.


2016 ◽  
Vol 11 (1) ◽  
pp. 35-42 ◽  
Author(s):  
Jerzy Wawrzeńczyk ◽  
Agnieszka Molendowska ◽  
Adam Kłak

The paper presents the results from the research on self-compacting concrete with different steel fibre type addition. The reference self-compacting concrete mix with water/binder = 0.33 was prepared, then modified with steel fibres in the amounts of 0–60 kg/m3 and air entrained with polymer microspheres (40 μm diameter). The major objective of the research was to determine the effect of steel fibre and air content on the self-compacting concrete mix properties and hardened concrete frost durability. The tests also included internal cracking and scaling resistance evaluation for concrete specimens subjected to cyclic freeze-thaw process − two beams were frozen in air and two beams were partially submerged in water and then frozen. The scaling resistance was tested using the slab method on the specimens with sawn surface and on the specimens with natural finished surface. Non-air entrained steel fibrereinforced concretes, despite their high strength class (C55/67–C60/75) and medium absorption (4.34–5.11%), showed unsatisfactory resistance to internal cracking and scaling tests. The beams partially submerged in water failed after 100 freeze-thaw cycles, which confirms a significant influence of water uptake from moist environment during freeze-thaw cycles and the acceleration of the damage process. Test results indicate that air entrainment with polymer microspheres is a very effective method and allows obtaining very good air pore structure parameters and frost resistance results. The specimens with top − finished surface exhibited less damage in the scaling resistance tests in relation to the specimens with sawn surface.


2014 ◽  
Vol 11 (4) ◽  
pp. 323-330 ◽  
Author(s):  
S. Arivalagan

The present day world is witnessing the construction of very challenging and difficult civil engineering structures. Self-compacting concrete (SCC) offers several economic and technical benefits; the use of steel fiber extends its possibilities. Steel fiber acts as a bridge to retard their cracks propagation, and improve several characteristics and properties of the concrete. Therefore, an attempt has been made in this investigation to study the Flexural Behaviour of Steel Fiber Reinforced self compacting concrete incorporating silica fume in the structural elements. The self compacting concrete mixtures have a coarse aggregate replacement of 25% and 35% by weight of silica fume. Totally eight mixers are investigated in which cement content, water content, dosage of superplasticers were all constant. Slump flow time and diameter, J-Ring, V-funnel, and L-Box were performed to assess the fresh properties of the concrete. The variable in this study was percentage of volume fraction (1.0, 1.5) of steel fiber. Finally, five beams were to be casted for study, out of which one was made with conventional concrete, one with SCC (25% silica fume) and other were with SCC (25% silica fume + 1% of steel fiber, 25% silica fume + 1.5% of steel fiber) one with SCC (35% silica fume), and other were SCC (35% Silica fume + 1% of steel fiber, 35% Silica fume + 1.5% of steel fiber). Compressive strength, flexural strength of the concrete was determined for hardened concrete for 7 and 28 days. This investigation is also done to determine the increase the compressive strength by addition of silica fume by varying the percentage.


Materials ◽  
2019 ◽  
Vol 12 (9) ◽  
pp. 1467 ◽  
Author(s):  
Maciej Szeląg ◽  
Bartosz Zegardło ◽  
Wojciech Andrzejuk

The paper describes a new model of concrete production, which contains a glass cullet. A worn-out car side window have been used for the production of recycled glass aggregate (RGA) and its properties were examined. The RGA was used in concrete as a 50% and 100% mass substitute of the traditional aggregate. Basic tests of fresh concrete mix and hardened concrete were carried out. The consistency, the air content in the concrete mix, the density of hardened concrete, water absorption, water resistance, frost resistance, and the compressive strength (after 9, 28, and 90 days) were evaluated. Composite samples were also subjected to microscopic analysis. The results showed that the RGA can be recommended as an aggregate for concretes, and the features of the RGA concrete are more favorable than those of traditional concrete. The microscopic analyses allowed us to identify the reasons for improving the properties of the RGA composites.


2016 ◽  
Vol 22 (4) ◽  
pp. 520-528 ◽  
Author(s):  
Beata ŁAŹNIEWSKA-PIEKARCZYK

The influence of a type of new generation: superplasticizer (SP), anti-foaming admixture (AFA) and viscosity modifying admixture (VMA) on the air-content, workability of high performance self-compacting concrete (HPSCC) is analyzed in the paper. The purpose of this study was to examine the influence of type of the admixtures on porosity of HPSCC in the aspect of the compressive strength. The research results indicated that type of admixtures and its combina­tions result in different strengths of HPSCC, regardless of the total porosity characteristics of HPSCC.


2010 ◽  
Vol 659 ◽  
pp. 517-521
Author(s):  
Viktória Sugár ◽  
Márton Takács ◽  
Vilmos Ovári

Recent research work of the authors is dealing with preparing, investigation and application of high performance concretes (HPC) produced by the mean of results of modern concrete technology. These special types of concrete have one or more outstanding properties conversely the normal concrete. This article is focusing on the results of the experiments regarding self compacting concrete (SCC). During the investigation, effects of the fine-graded fraction was studied, which is indispensable component of the SCC. The effects of bulk density, consistency, air content, compressive strenght were analysed on fresh and hardened concrete.


2019 ◽  
Vol 1 (1) ◽  
pp. 244-250
Author(s):  
Alina Pietrzak

Abstract Due to a constant increase in generating the amount of sewage waste it is necessary to find an alternative method of its use or disposal. One of such methods can be utilization of sewage sludge in construction materials industry, particularly in concrete technology and other materials based on cement. It allows using waste materials as a passive additive (filler) or also as an active additive (replacement of part of bonding material). The article aims at presenting the analysis of the effect of adding slag, achieved from wastewater sludge incineration in sewage treatment plant, on properties and quality of concrete mix and hardened concrete. Using an experimental method, the researcher designed the composition of the control concrete mix, which was then modified by means of slag. For all concrete mixtures determined – air content with the use of pressure method and consistency measured by the use of concrete slump test. For all concrete series the following tests were conducted: compressive strength of concrete after 7, 28 and 56 days of maturing, frost resistance for 100 cycles of freezing and thawing, water absorption. The use of slag, ground once in the disintegrator, causes a decrease of in compressive strength of concrete samples in relation to the control concrete series as well as bigger decrease in compressive strength after frost resistance test.


CONVERTER ◽  
2021 ◽  
pp. 110-117
Author(s):  
Yanxia Huang

To reduce air pollution of straw burning, and also to improve the ratio of straw comprehensive utilization, this paper presents a lightweight concrete with straw based on the mix proportion research. Firstly, the mix proportion of lightweight ceramsite concrete was designed by a volumetric method. Then, a series of lightweight ceramsite concrete mix proportion experiments were conducted to verify the validity of the design and to evaluate the effect of the admixtures on the performance of the concrete. Finally, the lightweight straw ceramsite concrete mix proportion experiments were conducted by adding straw to lightweight ceramsite concrete for studying the impact of the straw amount on the concrete strength and density. The experimental results show that the compressive strength of lightweight straw ceramsite concrete can reach the requirement of engineering application. The concrete strength and density were descended obviously with the increasing of straw amount. It was suggested that the straw amount should be limited in 20% of the concrete volume.


Sign in / Sign up

Export Citation Format

Share Document