scholarly journals PERFORMANCE OF AXIALLY LOADED TAPERED CONCRETE-FILLED STEEL COMPOSITE SLENDER COLUMNS

2013 ◽  
Vol 19 (5) ◽  
pp. 705-717 ◽  
Author(s):  
Alireza Bahrami ◽  
Wan Hamidon Wan Badaruzzaman ◽  
Siti Aminah Osman

This paper focuses on the performance of a special kind of tapered composite columns, namely tapered concrete-filled steel composite (TCFSC) slender columns, under axial loading. These efficient TCFSC columns are formed by the increase of the mid-height depth and width of straight concrete-filled steel composite (CFSC) slender columns, that is, by the enhancement of the tapered angle (from 0° to 2.75°) of the tapered composite columns from their top and bottom to their mid-height. To investigate the performance of the columns, finite element software LUSAS is employed to carry out the nonlinear analyses. Comparisons of the nonlinear finite element results with the existing experimental results uncover the reasonable accuracy of the proposed modelling. Nonlinear analyses are extensively performed and developed to study effects of different variables such as various tapered angles, steel wall thicknesses, concrete compressive strengths, and steel yield stresses on the performance of the columns. It is concluded that increasing each of these variables considerably enhances the ultimate axial load capacity. Also, enhancement of the tapered angle and/or steel wall thickness significantly improves the ductility. Moreover, confinement effect of the steel wall on the performance of the columns is evaluated. Failure modes of the columns are also presented.

2019 ◽  
Vol 8 (3) ◽  
pp. 3639-3648

In this research, response of steel beam-to-column bolted connections to blast loading is investigated. Nonlinear analyses of the connections are performed using the finite element software ABAQUS. In order to demonstrate the accuracy of the finite element modelling, an experimental test of a steel beam-to-column bolted connection is modelled. Comparison of the obtained result from the modelling with that of the corresponding experimental test verifies the modelling. Then, a 5-storey steel building is designed using ETABS software from which a beam-to-column connection of the ground floor is selected for the nonlinear analysis in ABAQUS. Thereafter, the components of the selected connection are designed. Finally, the connection is nonlinearly analysed considering parameters as the distance from the blast centre (2.5 m, 5 m, and 10 m) and blast power (500 kg, 1000 kg, and 2000 kg TNT equivalent mass of explosive). Effects of these parameters on the response of the connection are evaluated. Failure modes of the connections are assessed, too.


2019 ◽  
Vol 29 (2) ◽  
pp. 101-116
Author(s):  
Peyman Beiranvand ◽  
Matin Abdollahifar ◽  
Ahmad Moradpour ◽  
Saeideh Sadeghi Golmakani

Abstract In this study, a column with section IPE and different lengths, completely embedded in concrete, is modelled by finite element software ABAQUS. Columns under different bi-axial loading were used and graphs of axial force-axial deformation, interaction axial force, and bending moment and column curve were mapped. The results show that the load capacity of the column, with increasing length and also increasing eccentricity of the axial load, will be reduced. With increasing length, the effect of an increased eccentricity of the reduced load capacity was increased. Equations for the design of the column are also presented. The results of the presented equations were compared with the values obtained from finite element and building national institute 10th topic.


2013 ◽  
Vol 19 (3) ◽  
pp. 433-446 ◽  
Author(s):  
Alireza Bahrami ◽  
Wan Hamidon Wan Badaruzzaman ◽  
Siti Aminah Osman

This paper is concerned with the investigation of concrete-filled steel composite (CFSC) stub columns with bar stiffeners. In order to study the behaviour of the columns, the finite element software LUSAS is used to conduct the non-linear analyses. Results from the non-linear finite element analysis and the corresponding experimental test are compared which reveal the reasonable accuracy of the three-dimensional finite element modelling. A special arrangement of bar stiffeners in the columns with various number, spacing and diameters of the bar stiffeners are developed and studied using the non-linear finite element method. Effects of various variables such as different number and spacing of the bar stiffeners and also steel wall thicknesses on the ultimate axial load capacity and ductility of the columns are examined. Moreover, effects of different diameters of the bar stiffeners, concrete compressive strengths and steel yield stresses on the ultimate axial load capacity of the columns are evaluated. It is concluded from the study that the variables significantly influence the behaviour of the columns. The obtained results from the finite element analyses are compared with those predicted values by the design code EC4 and suggested equations of the previous researches.


Author(s):  
Nicholas Haritos ◽  
Anil Hira ◽  
Priyan Mendis ◽  
Rob Heywood ◽  
Armando Giufre

VicRoads, the road authority for the state of Victoria, Australia, has been undertaking extensive research into the load capacity and performance of cast-in-place reinforced concrete flat slab bridges. One of the key objectives of this research is the development of analytical tools that can be used to better determine the performance of these bridges under loadings to the elastic limit and subsequently to failure. The 59-year-old Barr Creek Bridge, a flat slab bridge of four short continuous spans over column piers, was made available to VicRoads in aid of this research. The static testing program executed on this bridge was therefore aimed at providing a comprehensive set of measurements of its response to serviceability level loadings and beyond. This test program was preceded by the performance of a dynamic test (a simplified experimental modal analysis using vehicular excitation) to establish basic structural properties of the bridge (effective flexural rigidity, EI) and the influence of the abutment supports from identification of its dynamic modal characteristics. The dynamic test results enabled a reliably tuned finite element model of the bridge in its in-service condition to be produced for use in conjunction with the static testing program. The results of the static testing program compared well with finite element modeling predictions in both the elastic range (serviceability loadings) and the nonlinear range (load levels taken to incipient collapse). Observed collapse failure modes and corresponding collapse load levels were also found to be predicted well using yield line theory.


2019 ◽  
Vol 16 (1) ◽  
pp. 14-22
Author(s):  
Sampath S. ◽  
Chithirai Pon Selvan M. ◽  
Mohamed Ameen K. ◽  
Mohamed Amin I.

PurposeThe purpose of this paper is to present the design and development of transfer seat system which aids the disabled drivers to get in and out of the car without outside help thereby reducing physical effort. The design of the model is carried out taking into account the vehicle specification and the weight of the person. After careful measurement and analysis, the required seat system parameters were estimated. The three movements associated with the system are satisfied with motors controlled by switches. The design calculations and the tests carried out are validated using the ANSYS finite element software.Design/methodology/approachThe whole process begins with the definition of the problem of eliminating the support of an additional person to help people with disabilities enter and leave a car, making it feasible and economical for the patients. Literature review includes and develops information from different sources. The research gap is identified and a necessary improvement is proposed. Design and analysis involves optimum design and calculation that achieves the efficiency, reliability and comfortable movement of the system. It also involves validation to support stress analysis in the system that is performed using ANSYS. The material supply includes the required materials taking into account factors such as strength, durability and availability. Manufacturing selects appropriate manufacturing techniques taking into account design, materials and space limitation. Operations such as welding, cutting, drilling and grinding are considered. The tests consist of performing a physical test to check the approximate load capacity of the system for a gentle, comfortable and secure comfort. Validation ensures that the results of the test coincide with the existing results of the supporting documentation. This process also involves taking corrective action and re-doing the design process to achieve the desired results.FindingsThe results that are plotted suggest that with the increase in downward force, the power required to balance it is greater. Similarly, the speed increases with increasing power. ANSYS analysis can be performed for the support structure and for obtaining deformation. The entire work can be implemented on the actual vehicle, and the time required for the patient to enter and exit could be calculated. The entire transfer system that operates by the engine can be modified, and a hydraulic system can be used to make the movements possible. The section of the rail can also be modified accordingly, and the comparison of the possible results can be carried out with the present system.Research limitations/implicationsThe entire system can be improvised by working on the mechanism which reduces the overall operating time without causing discomfort to the user when entering and exiting the car. Furthermore, the safety feature must be considered in the car to prevent the mechanism from altering the seating position of the seat, for which a mooring system can be inserted with a switch to hold it in place and release it. A powerful motor can be integrated into the mechanism to improvise the second movement, which is the deployment of the legs on the ground with the motorized wheels. The set of cast iron rails is used to support more weight without failure.Practical implicationsThe main objective is to design a system that allows a disabled person to enter and exit easily without the support or assistance of a second person. The design process had to be modified, and various methods were tried to incorporate this flawless movement onto the chassis of the car. Necessary changes have been made in the case of the material used and of the yarn to obtain the desired movement at the desired speed at the desired time. By performing these three movements, the secondary objective had to be integrated into the system to automate the door to facilitate the entry and exit of the car and to open the door simply by pressing a button. These results were taken into account to make the engine speed changes and the speed at which the chair will descend and move horizontally to ensure a safe design.Social implicationsThe developed transfer seat system can be widely used in healthcare sectors which greatly helps the movement of disabled persons.Originality/valueThe design calculations and tests carried out are validated using the ANSYS®, a finite element software.


2011 ◽  
Vol 306-307 ◽  
pp. 733-737
Author(s):  
Xu Dan Dang ◽  
Xin Li Wang ◽  
Hong Song Zhang ◽  
Jun Xiao

In this article the finite element software was used to analyse the values for compressive strength of X-cor sandwich. During the analysis, the failure criteria and materials stiffness degradation rules of failure mechanisms were proposed. The failure processes and failure modes were also clarified. In the finite element model we used the distributions of failure elements to simulate the failure processes. Meanwhile the failure mechanisms of X-cor sandwich were explained. The finite element analysis indicates that the resin regions of Z-pin tips fail firstly and the Z-pins fail secondly. The dominant failure mode is the Z-pin elastic buckling and the propagation paths of failure elements are dispersive. Through contrast the finite element values and test results are consistent well and the error range is -7.6%~9.5%. Therefore the failure criteria and stiffness degradation rules are reasonable and the model can be used to predict the compressive strength of X-cor sandwich.


Author(s):  
Gurumurthy Kagita ◽  
Gudimella G. S. Achary ◽  
Mahesh B. Addala ◽  
Balaji Srinivasan ◽  
Penchala S. K. Pottem ◽  
...  

Abstract Mechanical damage in subsea pipelines in the form of local dents / buckles due to excessive bending deformation may severely threaten their structural integrity. A dent / buckle has two significant effects on the pipeline integrity. Notably, residual stresses are set up as result of the plastic deformation and stress concentrations are created due to change in pipe geometry caused by the denting / buckling process. To assess the criticality of a dent / buckle, which often can be associated with strain induced flaws in the highly deformed metal, integrity assessment is required. The objective of this paper is to evaluate the severity of dent / buckle in a 48” subsea pipeline and to make the rerate, repair or replacement decision. This paper presents a Level 3 integrity assessment of a subsea pipeline dent / buckle with metal loss, reported in in-line inspection (ILI), in accordance with Fitness-For-Service Standard API 579-1/ASME FFS-1. In this paper, the deformation process that caused the damage (i.e. dent / buckle) with metal loss is numerically simulated using ILI data in order to determine the magnitude of permanent plastic strain developed and to evaluate the protection against potential failure modes. For numerical simulation, elastic-plastic finite element analyses (FEA) are performed considering the material as well as geometric non-linearity using general purpose finite element software ABAQUS/CAE 2017. Based on the numerical simulation results, the integrity assessment of dented / buckled subsea pipeline segment with metal loss has been performed to assess the fitness-for-service at the operating loads.


2018 ◽  
Vol 27 (1) ◽  
pp. 096369351802700
Author(s):  
Xiong Xueyu ◽  
Wang Yiqingzi ◽  
Xue Rongjun ◽  
Lu Xuanxing

As Chinese architecture masterpiece, ancient Hui-style architecture is the admiration for Chinese and foreign master builders. According to the bending test, the theoretical calculations and Abaqus finite element analysis on 5 Hui-style architecture beams, this paper points out the differences between un-reinforced beams and reinforced beams on ultimate bearing capacity, deflection and other performance indicators. The reinforcement methods of embedding steel bars, embedding CFRP bars and pasting CFRP plate can respectively improve the ultimate bearing capacity by 20.2%, 32.6% and 37.0%. Based on the plane section assumption and considering thereduction of tensile strength causedby wood knots and defects in tension zone, this paper predicts failure modes of the test beams may occur, and gives the ultimate bearing capacity of different failure modes. In addition, this paper uses the Abaqus finite element software for simulating test beams, and the development trend of load-deflectioncurve between the test and numerical simulation are in good agreement, providing reference for further research of Hui-style architecture.


2012 ◽  
Vol 568 ◽  
pp. 125-128
Author(s):  
Yu Zhuo Jia ◽  
Li Zhao

In the multiple-circuit on same tower UHV and large crossing transmission tower,The main material of towers usually using a composite section in the form of the dual-angle and four steel angle. Dual-angle and four steel angle connections are inevitable. 500KV Jianbi - Danfeng four circuit transmission line project for the background, Using the finite element software ANSYS10.0, Composite Joints three-dimensional nonlinear finite element simulation. Clear the path of force transferor the node, Mechanical behavior of gusset plate and node failure modes. The results show that: node failure modes for the strength failure, The ultimate bearing capacity of the node is about three times the load of the node design, Node design is relatively conservative, By reducing the thickness of the gusset plate to lower node weight.


Sign in / Sign up

Export Citation Format

Share Document