Rapid and Non-Invasive Techniques

2022 ◽  
pp. 41-66
Author(s):  
Muhammad Haseeb Ahmad ◽  
Amna Sahar ◽  
Muhammad Imran ◽  
Muhammad Kamran Khan ◽  
Rabia Shabir Ahmad ◽  
...  

In this modern era of digitalization and consumer awareness regarding food safety issues, it has become important to build proper strategies that can ensure the quality and safety of the food items from farm to forks. People love to eat at restaurants not only during business meetings but also with their family for fun and entertainment. The choice and safety of the food is vital to attract the consumer in this competitive environment. Previously, conventional methods have been employed for assurance of quality and safety parameters of the food. But in this modern era, there are many potential alternatives that can serve the purpose rapidly and non-destructively. Hence, this chapter describes the rapid and non-destructive methodologies such as fluorescence, NIRS, MIR, and Raman spectroscopy that can be used for the food safety evaluations.

Author(s):  
Pedro Dinis Gaspar ◽  
Pedro Dinho da Silva ◽  
Luís Pinto Andrade ◽  
José Nunes ◽  
Christophe Espírito Santo

Food safety and eradication of food waste are current concerns of society and governments due to health, ethics, and sustainable economics. There are multiple technologies for monitoring food safety at different chain stages, among them, time-temperature integrators (TTI). Temperature is a major factor affecting food quality and safety during its life cycle. This parameter can be monitored using TTI devices on food packages, allowing users to know the thermal exposure. This chapter addresses food safety issues, namely factors related to microbial growth responsible for food deterioration. Moreover, TTI monitoring technologies are also described, focusing on features, advantages, disadvantages, applicability, and product examples. Analysis of the current state of TTI and technological evolution, a prediction is provided for future TTI devices designed for more assertive, traceable, safe, and quality food products.


Author(s):  
Pedro Dinis Gaspar ◽  
Pedro Dinho da Silva ◽  
Luís Pinto Andrade ◽  
José Nunes ◽  
Christophe Espírito Santo

Food safety and eradication of food waste are current concerns of society and governments due to health, ethics, and sustainable economics. There are multiple technologies for monitoring food safety at different chain stages, among them, time-temperature integrators (TTI). Temperature is a major factor affecting food quality and safety during its life cycle. This parameter can be monitored using TTI devices on food packages, allowing users to know the thermal exposure. This chapter addresses food safety issues, namely factors related to microbial growth responsible for food deterioration. Moreover, TTI monitoring technologies are also described, focusing on features, advantages, disadvantages, applicability, and product examples. Analysis of the current state of TTI and technological evolution, a prediction is provided for future TTI devices designed for more assertive, traceable, safe, and quality food products.


Foods ◽  
2020 ◽  
Vol 9 (8) ◽  
pp. 1074 ◽  
Author(s):  
Severiano Silva ◽  
Cristina Guedes ◽  
Sandra Rodrigues ◽  
Alfredo Teixeira

In the last decade, there has been a significant development in rapid, non-destructive and non-invasive techniques to evaluate carcass composition and meat quality of meat species. This article aims to review the recent technological advances of non-destructive and non-invasive techniques to provide objective data to evaluate carcass composition and quality traits of sheep and goat meat. We highlight imaging and spectroscopy techniques and practical aspects, such as accuracy, reliability, cost, portability, speed and ease of use. For the imaging techniques, recent improvements in the use of dual-energy X-ray absorptiometry, computed tomography and magnetic resonance imaging to assess sheep and goat carcass and meat quality will be addressed. Optical technologies are gaining importance for monitoring and evaluating the quality and safety of carcasses and meat and, among them, those that deserve more attention are visible and infrared reflectance spectroscopy, hyperspectral imagery and Raman spectroscopy. In this work, advances in research involving these techniques in their application to sheep and goats are presented and discussed. In recent years, there has been substantial investment and research in fast, non-destructive and easy-to-use technology to raise the standards of quality and food safety in all stages of sheep and goat meat production.


2019 ◽  
Vol 19 (2) ◽  
pp. 105-111
Author(s):  
Nadia Shafei ◽  
Mohammad Saeed Hakhamaneshi ◽  
Massoud Houshmand ◽  
Siavash Gerayeshnejad ◽  
Fardin Fathi ◽  
...  

Background: Beta thalassemia is a common disorder with autosomal recessive inheritance. The most prenatal diagnostic methods are the invasive techniques that have the risk of miscarriage. Now the non-invasive methods will be gradually alternative for these invasive techniques. Objective: The aim of this study is to evaluate and compare the diagnostic value of two non-invasive diagnostic methods for fetal thalassemia using cell free fetal DNA (cff-DNA) and nucleated RBC (NRBC) in one sampling community. Methods: 10 ml of blood was taken in two k3EDTA tube from 32 pregnant women (mean of gestational age = 11 weeks), who themselves and their husbands had minor thalassemia. One tube was used to enrich NRBC and other was used for cff-DNA extraction. NRBCs were isolated by MACS method and immunohistochemistry; the genome of stained cells was amplified by multiple displacement amplification (MDA) procedure. These products were used as template in b-globin segments PCR. cff-DNA was extracted by THP method and 300 bp areas were recovered from the agarose gel as fetus DNA. These DNA were used as template in touch down PCR to amplify b-globin gen. The amplified b-globin segments were sequenced and the results compared with CVS resul. Results: The data showed that sensitivity and specificity of thalassemia diagnosis by NRBC were 100% and 92% respectively and sensitivity and specificity of thalassemia diagnosis by cff-DNA were 100% and 84% respectively. Conclusion: These methods with high sensitivity can be used as screening test but due to their lower specificity than CVS, they cannot be used as diagnostic test.


2020 ◽  
Vol 16 (2) ◽  
pp. 138-152
Author(s):  
Bingren Zhang ◽  
Chu Wang ◽  
Chanchan Shen ◽  
Wei Wang

Background: Responses to external emotional-stimuli or their transitions might help to elucidate the scientific background and assist the clinical management of psychiatric problems, but pure emotional-materials and their utilization at different levels of neurophysiological processing are few. Objective: We aimed to describe the responses at central and peripheral levels in healthy volunteers and psychiatric patients when facing external emotions and their transitions. Methods: Using pictures and sounds with pure emotions of Disgust, Erotica, Fear, Happiness, Neutral, and Sadness or their transitions as stimuli, we have developed a series of non-invasive techniques, i.e., the event-related potentials, functional magnetic resonance imaging, excitatory and inhibitory brainstem reflexes, and polygraph, to assess different levels of neurophysiological responses in different populations. Results: Sample outcomes on various conditions were specific and distinguishable at cortical to peripheral levels in bipolar I and II disorder patients compared to healthy volunteers. Conclusions: Methodologically, designs with these pure emotions and their transitions are applicable, and results per se are specifically interpretable in patients with emotion-related problems.


2021 ◽  
Vol 11 (3) ◽  
pp. 1341
Author(s):  
María Higuera ◽  
José M. Perales ◽  
María-Luisa Rapún ◽  
José M. Vega

A review of available results on non-destructive testing of physical systems, using the concept of topological sensitivity, is presented. This mathematical tool estimates the sensitivity of a set of measurements in some given sensors, distributed along the system, to defects/flaws that produce a degradation of the system. Such degradation manifests itself on the properties of the system. The good performance of this general purpose post-processing method is reviewed and illustrated in some applications involving non-destructive testing. These applications include structural health monitoring, considering both elastodynamic ultrasonic guided Lamb waves and active infrared thermography. Related methods can also be used in other fields, such as diagnosis/prognosis of engineering devices, which is also considered.


Animals ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 2200
Author(s):  
Ruben X. G. Silva ◽  
Paulo Cartaxana ◽  
Ricardo Calado

Berghia stephanieae is a stenophagous sea slug that preys upon glass anemones, such as Exaiptasia diaphana. Glass anemones host photosynthetic dinoflagellate endosymbionts that sea slugs ingest when consuming E. diaphana. However, the prevalence of these photosynthetic dinoflagellate endosymbionts in sea slugs appears to be short-lived, particularly if B.stephanieae is deprived of prey that host these microalgae (e.g., during bleaching events impacting glass anemones). In the present study, we investigated this scenario, along with food deprivation, and validated the use of a non-invasive and non-destructive approach employing chlorophyll fluorescence as a proxy to monitor the persistence of the association between sea slugs and endosymbiotic photosynthetic dinoflagellates acquired through the consumption of glass anemones. Berghia stephanieae deprived of a trophic source hosting photosynthetic dinoflagellate endosymbionts (e.g., through food deprivation or by feeding on bleached E. diaphana) showed a rapid decrease in minimum fluorescence (Fo) and photosynthetic efficiency (Fv/Fm) when compared to sea slugs fed with symbiotic anemones. A complete loss of endosymbionts was observed within 8 days, confirming that no true symbiotic association was established. The present work opens a new window of opportunity to rapidly monitor in vivo and over time the prevalence of associations between sea slugs and photosynthetic dinoflagellate endosymbionts, particularly during bleaching events that prevent sea slugs from incorporating new microalgae through trophic interactions.


2021 ◽  
Vol 18 (1) ◽  
Author(s):  
Andy Sombke ◽  
Carsten H. G. Müller

Abstract Background The jointed appendage is a key novelty in arthropod evolution and arthropod legs are known to vary enormously in relation to function. Among centipedes, the ultimate legs always are distinctly different from locomotory legs, and different centipede taxa evolved different structural and functional modifications. In Geophilomorpha (soil centipedes), ultimate legs do not participate in locomotion and were interpret to serve a sensory function. They can be sexually dimorphic and in some species, male ultimate legs notably appear “hairy”. It can be assumed that the high abundance of sensilla indicates a pronounced sensory function. This study seeks for assessing the sensory diversity, however, documents the surprising and unique case of an extensive glandular epithelium in the ultimate legs of three phylogenetically distant species. Results The tightly aggregated epidermal glands with stalked ducts – mistakenly thought to be sensilla – were scrutinized using a multimodal microscopic approach comprising histology as well as scanning and transmission electron microscopy in Haplophilus subterraneus. Hence, this is the first detailed account on centipede ultimate legs demonstrating an evolutionary transformation into a “secretory leg”. Additionally, we investigated sensory structures as well as anatomical features using microCT analysis. Contrary to its nomination as a tarsus, tarsus 1 possesses intrinsic musculature, which is an indication that this podomere might be a derivate of the tibia. Discussion The presence and identity of ultimate leg associated epidermal glands with stalked ducts is a new discovery for myriapods. A pronounced secretory as well as moderate sensory function in Haplophilus subterraneus can be concluded. The set of characters will improve future taxonomic studies, to test the hypotheses whether the presence of these specialized glands is a common feature in Geophilomorpha, and that tarsus 1 may be a derivate of the tibia. As the number of epidermal glands with stalked ducts is sexually dimorphic, their function might be connected to reproduction or a sex-specific defensive role. Our results, in particular the unexpected discovery of ‘glandular hairs’, may account for a striking example for how deceptive morphological descriptions of epidermal organs may be, if based on non-invasive techniques alone.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Supakorn Harnsoongnoen ◽  
Nuananong Jaroensuk

AbstractThe water displacement and flotation are two of the most accurate and rapid methods for grading and assessing freshness of agricultural products based on density determination. However, these techniques are still not suitable for use in agricultural inspections of products such as eggs that absorb water which can be considered intrusive or destructive and can affect the result of measurements. Here we present a novel proposal for a method of non-destructive, non-invasive, low cost, simple and real—time monitoring of the grading and freshness assessment of eggs based on density detection using machine vision and a weighing sensor. This is the first proposal that divides egg freshness into intervals through density measurements. The machine vision system was developed for the measurement of external physical characteristics (length and breadth) of eggs for evaluating their volume. The weighing system was developed for the measurement of the weight of the egg. Egg weight and volume were used to calculate density for grading and egg freshness assessment. The proposed system could measure the weight, volume and density with an accuracy of 99.88%, 98.26% and 99.02%, respectively. The results showed that the weight and freshness of eggs stored at room temperature decreased with storage time. The relationship between density and percentage of freshness was linear for the all sizes of eggs, the coefficient of determination (R2) of 0.9982, 0.9999, 0.9996, 0.9996 and 0.9994 for classified egg size classified 0, 1, 2, 3 and 4, respectively. This study shows that egg freshness can be determined through density without using water to test for water displacement or egg flotation which has future potential as a measuring system important for the poultry industry.


Biosensors ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 189
Author(s):  
David Bamgboje ◽  
Iasonas Christoulakis ◽  
Ioannis Smanis ◽  
Gaurav Chavan ◽  
Rinkal Shah ◽  
...  

Diabetes mellitus (DM) is a chronic disease that must be carefully managed to prevent serious complications such as cardiovascular disease, retinopathy, nephropathy and neuropathy. Self-monitoring of blood glucose is a crucial tool for managing diabetes and, at present, all relevant procedures are invasive while they only provide periodic measurements. The pain and measurement intermittency associated with invasive techniques resulted in the exploration of painless, continuous, and non-invasive techniques of glucose measurement that would facilitate intensive management. The focus of this review paper is the existing solutions for continuous non-invasive glucose monitoring via contact lenses (CLs) and to carry out a detailed, qualitative, and comparative analysis to inform prospective researchers on viable pathways. Direct glucose monitoring via CLs is contingent on the detection of biomarkers present in the lacrimal fluid. In this review, emphasis is given on two types of sensors: a graphene-AgNW hybrid sensor and an amperometric sensor. Both sensors can detect the presence of glucose in the lacrimal fluid by using the enzyme, glucose oxidase. Additionally, this review covers fabrication procedures for CL biosensors. Ever since Google published the first glucose monitoring embedded system on a CL, CL biosensors have been considered state-of-the-art in the medical device research and development industry. The CL not only has to have a sensory system, it must also have an embedded integrated circuit (IC) for readout and wireless communication. Moreover, to retain mobility and ease of use of the CLs used for continuous glucose monitoring, the power supply to the solid-state IC on such CLs must be wireless. Currently, there are four methods of powering CLs: utilizing solar energy, via a biofuel cell, or by inductive or radiofrequency (RF) power. Although, there are many limitations associated with each method, the limitations common to all, are safety restrictions and CL size limitations. Bearing this in mind, RF power has received most of the attention in reported literature, whereas solar power has received the least attention in the literature. CLs seem a very promising target for cutting edge biotechnological applications of diagnostic, prognostic and therapeutic relevance.


Sign in / Sign up

Export Citation Format

Share Document