Effect of Reinforcements on the Sliding Wear Behavior of Self-Lubricating AZ91D-SiC-Gr Hybrid Composites

Author(s):  
Sandeep Kumar Khatkar ◽  
Rajeev Verma ◽  
Suman Kant ◽  
Narendra Mohan Suri

This article statistically investigates the effect of various parameters such as material factors: silicon carbide (SiC) reinforcement, graphite (Gr) reinforcement and mechanical factors: normal load, sliding distance and speed on the sliding wear rate of vacuum stir cast self-lubricating AZ91D-SiC-Gr hybrid magnesium composites. The sliding wear tests have been performed on pin-on-disc tribometer at 10-50N loads, 1-3m/s sliding speed and 1000-2000m sliding distance. It has been examined that hybrid composites yielded improved wear resistance with reinforcement of SiC and solid lubricant graphite. ANOVA and signal-to-noise ratio investigation indicated that applied load was the most critical factor influencing the wear rate, followed by sliding distance. Further, the AZ91D/5SiC/5Gr hybrid composite has exhibited the best wear properties. From the SEM and EDS analysis of worn surfaces, delamination was confirmed as the dominant wear mechanism for AZ91D-SiC-Gr hybrid composites.

2017 ◽  
Vol 140 (2) ◽  
Author(s):  
Vineet Tirth

AA2218–Al2O3(TiO2) composites are synthesized by stirring 2, 5, and 7 wt % of 1:2 mixture of Al2O3:TiO2 powders in molten AA2218 alloy. T61 heat-treated composites characterized for microstructure and hardness. Dry sliding wear tests conducted on pin-on-disk setup at available loads 4.91–13.24 N, sliding speed of 1.26 m/s up to sliding distance of 3770 m. Stir cast AA2218 alloy (unreinforced, 0 wt % composite) wears quickly by adhesion, following Archard's law. Aged alloy exhibits lesser wear rate than unaged (solutionized). Mathematical relationship between wear rate and load proposed for solutionized and peak aged alloy. Volume loss in wear increases linearly with sliding distance but drops with the increase in particle wt % at a given load, attributed to the increase in hardness due to matrix reinforcement. Minimum wear rate is recorded in 5 wt % composite due to increased particles retention, lesser porosity, and uniform particle distribution. In composites, wear phenomenon is complex, combination of adhesive and abrasive wear which includes the effect of shear rate, due to sliding action in composite, and abrasive effect (three body wear) of particles. General mathematical relationship for wear rate of T61 aged composite as a function of particle wt % load is suggested. Fe content on worn surface increases with the increase in particle content and counterface temperature increases with the increase in load. Coefficient of friction decreases with particle addition but increases in 7 wt % composite due to change in microstructure.


2021 ◽  
Vol 49 (2) ◽  
pp. 414-421
Author(s):  
Manjunath Naik ◽  
L.H. Manjunath ◽  
Vishwanath Koti ◽  
Avinash Lakshmikanthan ◽  
Praveennath Koppad ◽  
...  

Graphene and carbon nanotubes are two carbon based materials known for their unique wear and friction properties. It would be quite interesting to understand the wear behavior of aluminium hybrid composites when these two nanosize reinforcements are incorporated into it. The hybrid composites with varying weight fractions of graphene (1, 2, 3 and 5 wt.%) and fixed CNT content of 2 wt.% were produced using powder metallurgy technique. The effect of varying graphene content on hardness and sliding wear of hybrid composites was studied. The wear tests were done as per ASTM G-99 standard with fixed sliding velocity (2 m/s) and sliding distance (1200 m) but varying applied load (10 - 30 N). Worn surface analysis was conducted using scanning electron microscope to arrive at wear mechanisms responsible for wear of aluminium and its hybrid composites. Increase in graphene content led to increase in bulk hardness with highest value of 61 RHN for hybrid composite with 3 wt.% graphene content. The wear rate of hybrid composites was found to be decreasing with enhancement in graphene content. Lower wear rate in hybrid composites was due to the formation of lubricating layer on the worn surface.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
M. Sudheer ◽  
Ravikantha Prabhu ◽  
K. Raju ◽  
Thirumaleshwara Bhat

This study evaluates the influence of independent parameters such as sliding velocity (A), normal load (B), filler content (C), and sliding distance (D) on wear performance of potassium-titanate-whiskers (PTW) reinforced epoxy composites using a statistical approach. The PTW were reinforced in epoxy resin to prepare whisker reinforced composites of different compositions using vacuum-assisted casting technique. Dry sliding wear tests were conducted using a standard pin on disc test setup following a well planned experimental schedule based on Taguchi’s orthogonal arrays. With the signal-to-noise (S/N) ratio and analysis of variance (ANOVA) optimal combination of parameters to minimize the wear rate was determined. It was found that inclusion of PTW has greatly improved the wear resistance property of the composites. Normal load was found to be the most significant factor affecting the wear rate followed by (C), (D), and (A). Interaction effects of various control parameters were less significant on wear rate of composites.


Author(s):  
Tej Singh ◽  
Gusztáv Fekete

Brake friction composite materials comprising varying proportions of natural (banana) and inorganic (lapinus) fibers were designed, fabricated by compression molding, and characterized for sliding wear performance. The sliding wear properties of the manufactured friction composites have been studied by the Taguchi method. An orthogonal array (L 16) was used to investigate the influence of sliding wear parameters. A series of tests were conducted on a pin-on-disc machine by considering four control parameters: composition, normal load, sliding velocity, and sliding distance, each having four levels. The results showed that the wear in terms of weight loss decreases with increasing banana fiber and increases with increasing lapinus fiber, normal load, sliding velocity, and sliding distance. The results indicate that the normal load emerges as the most significant control parameter affecting wear performance, followed by sliding distance and sliding velocity.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3074
Author(s):  
Kaveh Torkashvand ◽  
Vinod Krishna Selpol ◽  
Mohit Gupta ◽  
Shrikant Joshi

Sliding wear performance of thermal spray WC-based coatings has been widely studied. However, there is no systematic investigation on the influence of test conditions on wear behaviour of these coatings. In order to have a good understanding of the effect of test parameters on sliding wear test performance of HVAF-sprayed WC–CoCr coatings, ball-on-disc tests were conducted under varying test conditions, including different angular velocities, loads and sliding distances. Under normal load of 20 N and sliding distance of 5 km (used as ‘reference’ conditions), it was shown that, despite changes in angular velocity (from 1333 rpm up to 2400 rpm), specific wear rate values experienced no major variation. No major change was observed in specific wear rate values even upon increasing the load from 20 N to 40 N and sliding distance from 5 km to 10 km, and no significant change was noted in the prevailing wear mechanism, either. Results suggest that no dramatic changes in applicable wear regime occur over the window of test parameters investigated. Consequently, the findings of this study inspire confidence in utilizing test conditions within the above range to rank different WC-based coatings.


2009 ◽  
Vol 423 ◽  
pp. 125-130 ◽  
Author(s):  
Alvaro Mestra ◽  
Gemma Fargas ◽  
Marc Anglada ◽  
Antonio Mateo

Duplex stainless steels contain similar amounts of austenite  and ferrite α. This two-phase microstructure leads to an excellent combination of mechanical properties and corrosion resistance. However, there are few works dealing with the wear behaviour of these steels. This paper aims to determine the sliding wear mechanisms of a duplex stainless steel type 2205. In order to do it, three different sliding velocities (0.2, 0.7 and 1.2 m/s) and six sliding distances (500, 1000, 2000, 3000, 4000 and 5000 m) were selected. The results show that wear rate depends on both sliding velocity and sliding distance. The wear mechanisms detected were plowing, microcracking and microcutting (typical mechanisms of fatigue wear). These mechanisms evolve according to sliding velocity and sliding distance, highlighting a transition zone in which wear rate is reduced.


Author(s):  
Mohammad Pourmostafaei ◽  
Mohammad Pourgol-Mohammad ◽  
Mojtaba Yazdani ◽  
Hossein Salimi

In this paper, a new model is proposed for system degradation evaluation under sliding wear failure mechanism. This model estimates the material loss by progression of sliding distance. This model is generated by considering physical and geometrical aspects of system under wear mechanism. Several sets of experimental data are used for validation of the presented model. These experimental data are related to pin-on-disc test of Tungsten Carbide pins. These sets of data include initially conformal and non-conformal contacts. One set of data of pin-on-disc test by ASTM-G99 standard is used for additional validation of the model and for investigation of normal load effects on the parameters of presented model. Finally, uncertainty analysis is done by Monte-Carlo simulation to determine the variations of the predicted wear caused material loss.


An investigational analysis was conducted to study the effect of basalt/curaua hybrid composite focusing on wear properties. The hybrid composites are fabricated by resin transfer molding and the tests are conducted by pin on disk as per ASTM G99. Basalt/Curaua relative fiber weight percentage as 0/100,40/60, 60/40, 100/0 are fabricated and analyzed for abrasion wear resistance. Specimens are tested for the load of 50N at 1 m/s using Pin on Disc wear testing machine by varying abrading distance. Worn out surfaces of the abraded composites are studied by using scanning electron microscopy (SEM) and Fourier- transform infrared spectroscopy (FTIR). Roughness of the worn and pure surfaces is also accounted to measure significance of hybridization on tribological properties of the hybrid composites. Result shows that coefficient of friction is increasing in higher the curaua fiber in hybrid composites. Morphology evident the wear mechanism and internal compatibility of hybrid fibers.


Friction ◽  
2020 ◽  
Author(s):  
Jinjuan Cheng ◽  
Mincong Mao ◽  
Xueping Gan ◽  
Qian Lei ◽  
Zhou Li ◽  
...  

Abstract Alloys used as bearings in aircraft landing gear are required to reduce friction and wear as well as improve the load-carrying capability due to the increased aircraft weights. Cu-15Ni-8Sn-0.8Nb alloy is well known for possessing good mechanical and wear properties that satisfy such requirements. In this study, the microstructure, mechanical properties, and grease-lubricated sliding wear behavior of Cu-15Ni-8Sn-0.8Nb alloy with 0.8 wt% Nb are investigated. The nanoscale NbNi3 and NbNi2Sn compounds can strengthen the alloy through the Orowan strengthening mechanism. A Stribeck-like curve is plotted to illustrate the relationship among friction coefficient, normal load, and sliding velocity and to analyze the grease-lubricated mechanism. The wear rate increases with normal load and decreases with sliding velocity, except at 2.58 m/s. A wear mechanism map has been developed to exhibit the dominant wear mechanisms under various friction conditions. When the normal load is 700 N and the sliding velocity is 2.58 m/s, a chemical reaction between the lubricating grease and friction pairs occurs, resulting in the failure of lubricating grease and an increase in wear.


2021 ◽  
Vol 23 (06) ◽  
pp. 729-741
Author(s):  
Kamalakannan R ◽  
◽  
Somasundram A ◽  

Chromium (Cr), Copper (Cu), Cobalt (Co), Ferrous (Fe) and Nickel (Ni), the HighEntropy Alloys were mixed to form analloy. A die was created using OHNS (OilHardenedNickelSteel).Thealloyed powderwasloadedintothedieandaloadof13KNwas applied. Universal Testing Machine (UTM) was used for the load application. Afterpressing, the specimen was kept inside the Muffle Furnace for heating at 600°C for sintering. After heating, the surface of the specimen was smoothened byroughing. The weight of the specimen was noted, before and after the wear test.The specimen was subjected to wear test in Pin on Disc Machine. Wear rate of thespecimen was calculated. This specimen was used to coat the Single Point Cuttingtool. This coating of tool was done to decrease the wear rate and increase the lifeofthe tool.


Sign in / Sign up

Export Citation Format

Share Document