Study on Optimization of Operating Parameters for Modified A2/O Process in Changchun Northern Sewage Treatment Plant

2013 ◽  
Vol 409-410 ◽  
pp. 182-186
Author(s):  
Jun Yin ◽  
Jun Xiang Wang ◽  
Jia Ni Li ◽  
Jing Yi Cui

Based on the problem which is water quality instability and high energy consumption in the running of modified A2/O system in Changchun northern sewage treatment plant, we established the optimum parameters and optimized the operation conditions to provide technical support for the stable operation of the wastewater treatment plant by analyzing effect of the system in different conditions Test results showed the best dissolved oxygen concentration in the end of the aerobic tank, sludge recycling ratio and inner recycling ratio should be chosen 1.5~2.5mg/L, 80% and 180%. The operation results with optimal operation conditions showed that COD, ammonia nitrogen, SS, TN and TP removal rate were 89.07%, 80.44%, 95.27%, 61.09% and 89.88%. The process system effect is stable and effluent can satisfy the sewage discharged standards.

2014 ◽  
Vol 522-524 ◽  
pp. 854-860
Author(s):  
Qing Tao Zhang ◽  
Zhi Jian Zhang ◽  
Jiong Ma ◽  
Jiao Xiang

The growth performance of duckweed (Spirodela polyrrhiza) and its removal rate of nitrate and phosphorus in sewages taken from sewage treatment plant with different processes were studied. The experiments were conducted in an environmentally controlled growth chamber. Three kinds of sewages were taken from a grit chamber, a sedimentation tank, and the anoxic pond in a sewage treatment plant, respectively. The fourth kind of sewage was mixed using the sedimentation tank sewage and the anoxic pond sewage in a volumetric ratio 1:1. The weight of duckweed biomass were determined with a balance. Wastewater samples taken from the media were analyzed for total nitrogen (TN), ammonium nitrogen (NH4N), total phosphorus (TP), phosphatephosphorus (PO4P) using AA3 Continous Flow Analyzer. The results showed that Spirodela polyrrhiza grew well in sewages taken from grit chamber and sedimentation tank of a sewage treatment plant, whereas a lot of duckweed fronds were dead in the sewage taken from the anoxic pond due to the high TP (higher than 7.9 mg/L) and TN (higher than 51.6 mg/L). The suitable TN concentration for Spirodela polyrrhiza growth should not be higher than 45 mg/L. Compared with the treatments without duckweed, the NH4N concentrations were reduced more than 60% in ST and GC sewages with duckweed due to the NH4N uptake by duckweed. Spirodela polyrrhiza could remove TN efficiently in sewages with relative low concentration TN (less than 20 mg/L), while duckweed could not remove TN effectively in sewages with high concentration TN (higher than 20 mg/L). The TN concentration in GC sewage decreased greatly in the first four days, which probably brought about anaerobic condition, thus P uptake switched to net release of P, which caused the increase of the TP concentration in the GC sewage without duckweed in the last six days. O2 or oxidant should be provided for sewage treatment system using duckweed to ensure that efficient removal of TN and TP meanwhile. The TP and PO4P concentrations in the mixed sewage with duckweed increased far more than those for no-duckweed treatments, which could be related that the dead duckweed released P into the sewage.


2015 ◽  
Vol 737 ◽  
pp. 649-652
Author(s):  
Ming Li ◽  
Shuai Wang ◽  
De Chen Shan ◽  
Li Wei ◽  
Wen Jia Yin

In this study, IC anaerobic reactor was made to deal with the wastewater with high-concentration sulfate, the sludge from sewage treatment plant was put into two cells of IC reactor to domesticate sulfur-reducing bacteria (SRB), artificial water was made to simulate the wastewater with high-concentration SO42−. In order to remove the SO42− efficiently, two stages were designed in this study: sludge domestication stage and concentration strengthening stage. In sludge domestication stage, SRB could grow normally, the removal rate of SO42− was between 34.14% and 36.2%;in concentration strengthening stage, removal rate of SO42− was between 26% and 26.86%,demonstrating that SRB could grow and remove SO42− in such high-concentration SO42−( 38000 mg/L ) wastewater.


2013 ◽  
Vol 361-363 ◽  
pp. 601-605
Author(s):  
Ji Ku Zhang ◽  
Yang Yang Li ◽  
Chen Zhang ◽  
Yan Bin Yang

By treating the secondary effluent of Sanbaotun sewage treatment plant in Fushun with the CS type UV Sterilizer, the experiment researches the influence on the removal rate which includes the factors of turbidity, chromaticity, initial E.coli concentration of raw water, UV dose. The results show that the turbidity does not influence on UV disinfection efficiency with the turbidity from 1.5NTU to 3.8NTU. In the low-dose UV disinfection process, the influent sewage turbidity should under 4NTU to ensure the disinfection efficiency. Low chromaticity does not affect the UV disinfection efficiency, with the influent sewage chromaticity is under 15 degrees.The initial E. coli has a certain impact on little doses of UV disinfection with the concentration from 175 × 104 A/ L to 230 × 104 A/ L, no impact on high doses of UV disinfection。


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Zarimah Mohd Hanafiah ◽  
Wan Hanna Melini Wan Mohtar ◽  
Hassimi Abu Hasan ◽  
Henriette Stokbro Jensen ◽  
Anita Klaus ◽  
...  

Abstract The fluctuation of domestic wastewater characteristic inhibits the current conventional microbial-based treatment. The bioremediation fungi has received attention and reported to be an effective alternative to treat industrial wastewater. Similar efficient performance is envisaged for domestic wastewater whereby assessed performance of fungi for varying carbon-to-nitrogen ratios in domestic wastewater is crucial. Thus, the performance of pre-grown wild-Serbian Ganoderma lucidum mycelial pellets (GLMPs) was evaluated on four different synthetic domestic wastewaters under different conditions of initial pH (pH 4, 5, and 7) and chemical oxygen demand (COD) to nitrogen (COD/N) ratio of 3.6:1, 7.1:1, 14.2:1, and 17.8:1 (C3.6N1, C7.1N1, C14.2N1, and C17.8N1). The COD/N ratios with a constant concentration of ammonia–nitrogen (NH3–N) were chosen on the basis of the urban domestic wastewater characteristics sampled at the inlet basin of a sewage treatment plant (STP). The parameters of pH, COD, and NH3–N were measured periodically during the experiment. The wild-Serbian GLMPs efficiently removed the pollutants from the synthetic sewage. The COD/N ratio of C17.8N1 wastewater had the best COD and NH3–N removal, as compared to the lower COD/N ratio, and the shortest treatment time was obtained in an acidic environment at pH 4. The highest percentage for COD and NH3–N removal achieved was 96.0% and 93.2%, respectively. The results proved that the mycelium of GLMP has high potential in treating domestic wastewater, particularly at high organic content as a naturally sustainable bioremediation system.


2020 ◽  
Vol 145 ◽  
pp. 02052
Author(s):  
Weijian Zhou ◽  
Wenzhong Liang ◽  
Yining Ding ◽  
Yutao Lei ◽  
Zhihua Pang ◽  
...  

Considering the land shortage features of a given district in Hangzhou city, the High-sludge sedimentation tank + denitrification filtering tank + nitrification filtering tank + cloth media filtering tank process is adopted for purification treatment. When the system (with the treatment scale of 15,000m3/d) runs for 60 days, the average removal rate of COD and ammoniacal nitrogen are 86% and 96% respectively and the effluent quality reach the quasi grade IV standard.


2015 ◽  
Vol 737 ◽  
pp. 635-638
Author(s):  
Ke Zhao ◽  
Zheng Kong

The general existing low temperature problem in winter of north-city sewage treatment plant in the process of waste water treatment seriously affect the efficiency of the work. The research objective of this paper is to conduct investigate in the application of AICS method in Jilin Province, a sewage treatment plant engineering example has been employed to monitor the effluent of the indicators of sewage treatment under the low temperature condition during the winter the winter low temperature under the condition of sewage treatment plant effluent of the indicators; to understand the operation situation of sewage treatment plant, and to study the efficiency of hydrolysis - AICS processing waste-water. The result shows that: hydrolysis - AICS process works well in low temperature condition, the per TN removal rate is 76.79%, average removal rate of NH3 - N is 85.76%, average TP removal rate was 93.4%, the average COD removal rate was 90.6%. The effluent meet the national level A discharge standard requirements of "urban sewage treatment plant pollutant discharge standard". And through the retrenchment of the second pond and other ancillary equipment, Hydrolysis-AICS process could efficiently reduce the costs. Besides, the advantages of Hydrolysis-AICS process also include occupying small area, and operating easily and simply. Therefore Hydrolysis-AICS process is very helpful to achieve the sewage discharging standard in the northern towns.


2014 ◽  
Vol 535 ◽  
pp. 511-514
Author(s):  
Yu Mei Guo ◽  
Si Huang ◽  
Bo Liu ◽  
Fang Guo ◽  
Yan Yan Zhang ◽  
...  

The 3AMBR technology had been put into use in a sewage treatment plant of Kunming in 2010, emission standards at the national level A standard, and running in good condition currently. This paper based on the four seasons along the data of the water plant, the operating principle, situation and existing problems of 3AMBR technology were deeply discussed through analyzing the path parameter data process (DO, ORP, TN, TP, NH3-N, NO3-N, MLSS, COD). The research found that the technology had advantages of effluent in good quality, stable operation and less sludge, at the same time existed some phenomenon of excess aeration, long sludge age and water shortage of carbon source.


2020 ◽  
Vol 165 ◽  
pp. 02026
Author(s):  
Lintang Yu ◽  
Zhongya Tang ◽  
Li Feng ◽  
Junjie Ji

As the raising of environmental protection requirements, the outlet water (tailwater) quality standards of many sewage treatment plants need to be further improved. This paper mainly introduces the advanced treatment of tailwater from sewage treatment plant of vein industrial park by artificial ecological lake. The designed processing amount of this project was 1300 m3/d, the inlet water COD was 30 mg/L, the ammonia nitrogen content was 1.5 mg/L, and the outlet water main index reached the surface water environment quality standard (GB3838-2002) Ⅲ class water quality standard, which had improved the outlet water (tailwater) quality of sewage treatment plants and improved the regional water environment quality. By constructing an artificial landscape lake, the resource utilization of tailwater can be realized.


1992 ◽  
Vol 25 (4-5) ◽  
pp. 59-66 ◽  
Author(s):  
C. Andersson ◽  
M. Tendaj ◽  
M. Rothman

The requirements for purification of the sewage will be more stringent in Sweden. For the three plants in Stockholm - Henriksdal, Bromma and Loudden the proposed limit concentrations for BOD7, total phosphorus and total nitrogen are 10, 0.3 and 15 respectively. A limit value of 0.3 mg/l of phosphorus in the effluent will require a filtration stage. In this paper results are presented from filter tests at Bromma sewage treatment plant. The tests were carried out during almost two years and included operation of different types of sand dual-media downflow filters and an upflow filter. The filters were tested with respect to sludge accumulation capacity, suspended solids removal and phosphorus removal at different operation conditions including chemical precipitation in the filters.


Processes ◽  
2019 ◽  
Vol 7 (11) ◽  
pp. 827 ◽  
Author(s):  
Yong Li ◽  
Siyuan Zhao ◽  
Jiejie Zhang ◽  
Yang He ◽  
Jianqiang Zhang ◽  
...  

The aerobic denitrifying phosphate accumulating bacteria (ADPB) use NO3− as an electron acceptor and remove nitrate by denitrification and concomitant uptake of excessive phosphorus in aerobic conditions. Activated sludge was collected from the A2O aerobic biological pool of the sewage treatment plant at Hezuo Town, Chengdu City. The candidate ADPB strains were obtained by cultivation in the enriched denitrification media, followed by repeated isolation and purification on bromothymol blue (BTB) solid plates. The obtained candidates were further screened for ADPB strains by phosphorus uptake experiment, nitrate reduction test, metachromatic granules staining, and poly-β-hydroxybutyrate (PHB) staining. The 16 sedimentation ribosome deoxyribonucleic acid (16 S rDNA) molecular technique was used to determine their taxonomy. Further, the denitrification and dephosphorization capacities of ADPB strains were ascertained through their growth characteristics in nitrogen-phosphorus-rich liquid media. The results revealed a total of 25 ADPB strains screened from the activated sludge of the A2O aerobic biological pool of the sewage treatment plant at Hezuo Town. These strains belonged to two classes, four orders, and five genera. Among them, the strain SW18NP2 was a potentially new species in the Acinetobacter genus, while the strain SW18NP24 was a potential new species in the Pseudomonas genus at the time of their characterization. The Acinetobacter was the dominant genus. The obtained ADPB strains demonstrated a rich diversity. The ADPB strains had significant variations in denitrification and dephosphorization capacities. Twenty-three strains exhibited a total phosphorus removal rate of above 50%, and 19 strains exhibited a total nitrogen removal rate of above 50%. The strain SW18NP2 showed the best denitrifying phosphorus removal (DPR) capacity, with a dephosphorization rate of 82.32% and a denitrification rate of 73.73%. The ADPB in the A2O aerobic biological pool of the sewage treatment plant at Hezuo Town demonstrated a rich diversity and a strong DPR capacity.


Sign in / Sign up

Export Citation Format

Share Document