Computational Investigation of Heat Transfer of Nanofluids in Domestic Water Heat Exchanger

2014 ◽  
Vol 695 ◽  
pp. 423-427
Author(s):  
Nor Azwadi Che Sidik ◽  
Lee Yoke Keen ◽  
Alireza Fazeli

Recent development of nanotechnology led to the concept of using suspended nanoparticles in the heat transfer fluids to improve the heat transfer properties of the base fluids. The heat transfer enhancement by nanofluids is the significant concerns in the efficiency of domestic water heat exchanger system. A computational investigation of the heat transfer in a domestic water heat exchanger is conducted on the water and water-based nanofluids. Copper (Cu) nanoparticle and Alumina (Al2O3) nanoparticle are selected in the water-based nanofluids. Volume fraction of nanoparticle in the nanofluids is set at 0.5 %, 1.0 %, 1.5 %, 2.0 %, 2.5 %, and 3.0 %. Heat exchanger has been invented for the heat transfer from one medium to another medium in many heat transfer systems. Domestic water heat exchanger can be used in a heat pump domestic water heating system. The density, the thermal conductivity, and the dynamic viscosity of the water base fluid are increased while the specific heat capacity of the water base fluid is reduced with the addition of copper as well as alumina nanoparticle. Addition of copper nanoparticle into the water-based heat transfer fluid significantly increases the domestic hot water temperature. The efficiency of domestic water heat exchanger system is optimum when 1.5 % copper or alumina nanoparticle is added into the water-based heat transfer fluid.

2021 ◽  
Vol 21 (2) ◽  
pp. 148-163
Author(s):  
Mawj K. Qasim ◽  
Hadi O. Basher ◽  
Mohammed D. Salman

This study aims to enhancement of heat transfer in double pipe heat exchanger by improving the thermal properties of base fluid which is water by adding AL2O3-Fe2O3 nanoparticles to the water. Al2O3-Fe2O3/water hybrid Nanofluid were examined experimentally and numerically at different flow rates ranging between (3 -7) Lpm at temperature of 25°C in an external tube while there was a hot water at a temperature of 60°C and a flow rate ranged between (3 – 5) Lpm running in the central tube of a double pipe counter heat exchanger. Also, the effect of various concentrations ranged between (0.05, 0.1, 0.15, 0.2, 0.25 and 0.3%) of Al2O3-Fe2O3 nanoparticles dispersed in water on the rate of heat transfer, friction coefficient were verified experimentally and numerically . The ratio of Al2O3-Fe2O3 is 0.5:0.5. The experimental and numerical study indicated that with the rate of heat transfer increases when the concentration of suspended nanoparticles in the base fluid increases , but on the other hand, the skin friction coefficient and pressure drop increases as well with increasing the concentration of nanoparticles. The maximum enhancement in heat transfer for AL2O3-Fe2O3 is about 6 % . The results from the experimental study were largely consistent with the numerical results.


Heat transfer augmentation of a heat exchanger with a multi-heat pipe has been investigated with the influence of gravity assistance. The working fluids used to analyse the performance are methanol and acetone. Water is used as a heat transfer fluid. In which, the analysis is carried out with the gravity-assisted angles of 0º, 45º and 90º. In this work, various parameters such as temperatures of hot water ranges 50ºC, 60ºC, 70ºC, and cold water temperature are observed as 32.5ºC throughout the investigation. Hot water mass flow rates as 40 LPH to 120 LPH with an increase of 20 LPH, cold water as 20 LPH to 60 LPH with an increase of 10 LPH. The result reveals that increase in effectiveness occurs at an angle of 0º for Acetone with 60ºC and 100 LPH is 71.5% of an increase in effectiveness is achieved than methanol for optimum said conditions.


2020 ◽  
Vol 851 ◽  
pp. 38-46
Author(s):  
Avita Ayu Permanasari ◽  
Fadel Fadillah ◽  
Poppy Puspitasari ◽  
Sukarni Sukarni

Nanofluid is an efficient fluid when used in heat exchanger system because of its larger thermal conductivity compared to conventional fluids such as water, oil, and ethylene glycol (EG). This research used MnFe2O4 nanoparticle due to its higher magnetic sensitivity compared to other ferrite nanoparticles and larger thermal conductivity than TiO2. This research used the MnFe2O4 nanoparticle with a combination of EG-Water base fluids in ratios of 40:60, 60:40, and 80:20. MnFe2O4 nanofluid mixed with EG-Water base fluids was made using the two-step method with 0.05% MnFe2O4 volume fraction in each base fluid ratio. This research used shell and tube type heat exchanger with heat temperature of 60°C and cold temperature of 26°C that were carried out at volumetric flowrate in each base fluid ratio for 0.22 l/m, 0.44 l/m, and 0.66 l/m. This research aimed to find the best combination ratio of EG-Water in thermophysical (thermal conductivity, specific heat, density, and viscosity) and to find the effect of volumetric flowrate variations on the heat exchange characteristics (the Reynold number, the Nusselt number, ∆T LMTD, convection coefficient, heat transfer, and overall heat transfer coefficient). The results of this research were that the sample of EG-Water with 40:60 ratio had the best heat transfer characteristics compared to samples with 60:40 and 80:20 ratios. Meanwhile, for the volumetric flow rate, a higher volumetric flow rate resulted in a larger result.


2018 ◽  
Vol 280 ◽  
pp. 36-42 ◽  
Author(s):  
H. Haiza ◽  
I.I. Yaacob ◽  
Ahmad Zahirani Ahmad Azhar

Magnetic magnetite, Fe3O4 nanoparticles produced by Massart’s procedure were used to prepare water based magnetite, Fe3O4 ferrofluids without addition of any stabilizing agent or surfactant. The thermal properties and suspension stabilization of the ferrofluids were investigated by varying the magnetite, Fe3O4 nanoparticles concentration in the ferrofluids prepared. The thermal conductivity of water based ferrofluids prepared using five different volume fraction of magnetite, Fe3O4 suspension (0.1, 0.05, 0.02, 0.01 and 0.005) were measured at five different temperature, 25°C, 30°C, 40°C, 50°C and 60°C in order to evaluate its potential application as heat transfer fluid. The results shows that the thermal conductivity of the ferrofluids are higher than the base fluid, and the thermal conductivity of the ferrofluids increased as the magnetite concentration in the ferrofluids decreased however reached its optimum for ferrofluids prepared using 0.01 volume fraction of magnetite suspension over 0.99 volume fraction of water. Accordingly, the thermal conductivity of the ferrofluids significantly increased as the temperature increased where 49.4% enhancement with respect to water were observed at temperature 60°C.


2018 ◽  
Vol 6 (3) ◽  
pp. 1-12
Author(s):  
Kamil Abdul Hussien

Abstract-The present work investigates the enhancement of heat transfer by using different number of circular fins (8, 10, 12, 16, and 20) in double tube counter flow heat exchanger experimentally. The fins are made of copper with dimensions 66 mm OD, 22 mm ID and 1 mm thickness. Each fin has three of 14 mm diameter perforations located at 120o from each to another. The fins are fixed on a straight smooth copper tube of 1 m length, 19.9 mm ID and 22.2 mm OD. The tube is inserted inside the insulated PVC tube of 100 mm ID. The cold water is pumped around the finned copper tube, inside the PVC, at mass flow rates range (0.01019 - 0.0219) kg/s. The Reynold's number of hot water ranges (640 - 1921). The experiment results are obtained using six double tube heat exchanger (1 smooth tube and the other 5 are finned one). The results, illustrated that the heat transfer coefficient proportionally with the number of fin. The results also showed that the enhancement ratio of heat transfer for finned tube is higher than for smooth tube with (9.2, 10.2, 11.1, 12.1 13.1) times for number of fins (8, 10, 12, 16 and 20) respectively.


2014 ◽  
Vol 18 (suppl.1) ◽  
pp. 189-200 ◽  
Author(s):  
Primoz Ternik ◽  
Rebeka Rudolf

The present work deals with the natural convection in a square cavity filled with the water-based Au nanofluid. The cavity is heated on the vertical and cooled from the adjacent wall, while the other two horizontal walls are adiabatic. The governing differential equations have been solved by the standard finite volume method and the hydrodynamic and thermal fields were coupled together using the Boussinesq approximation. The main objective of this study is to investigate the influence of the nanoparticles? volume fraction on the heat transfer characteristics of Au nanofluids at the given base fluid?s (i.e. water) Rayleigh number. Accurate results are presented over a wide range of the base fluid Rayleigh number and the volume fraction of Au nanoparticles. It is shown that adding nanoparticles in a base fluid delays the onset of convection. Contrary to what is argued by many authors, we show by numerical simulations that the use of nanofluids can reduce the heat transfer rate instead of increasing it.


2017 ◽  
Vol 6 (4) ◽  
pp. 83 ◽  
Author(s):  
Gaurav Thakur ◽  
Gurpreet Singh

The thermal performance of shell and tube heat exchangers has been enhanced with the use of different techniques. Air bubble injection is one such promising and inexpensive technique that enhances the heat transfer characteristics inside shell and tube heat exchanger by creating turbulence in the flowing fluid. In this paper, experimental study on heat transfer characteristics of shell and tube heat exchanger was done with the injection of air bubbles at the tube inlet and throughout the tube with water based Al2O3 nanofluids i.e. (0.1%v/v and 0.2%v/v). The outcomes obtained for both the concentrations at two distinct injection points were compared with the case when air bubbles were not injected. The outcomes revealed that the heat transfer characteristics enhanced with nanoparticles volumetric concentration and the air bubble injection. The case where air bubbles were injected throughout the tube gave maximum enhancement followed by the cases of injection of air bubbles at the tube inlet and no air bubble injection. Besides this, water based Al2O3 nanofluid with 0.2%v/v of Al2O3 nanoparticles gave more enhancement than Al2O3nanofluid with 0.1%v/v of Al2O3 nanoparticles as the enhancement in the heat transfer characteristics is directly proportional to the volumetric concentration of nanoparticles in the base fluid. The heat transfer rate showed an enhancement of about 25-40% and dimensionless exergy loss showed an enhancement of about 33-43% when air bubbles were injected throughout the tube. Moreover, increment in the heat transfer characteristics was also found due to increase in the temperature of the hot fluid keeping the flow rate of both the heat transfer fluids constant.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


2021 ◽  
Author(s):  
praveen math

Abstract Shell and Tube heat exchangers are having special importance in boilers, oil coolers, condensers, pre-heaters. They are also widely used in process applications as well as the refrigeration and air conditioning industry. The robustness and medium weighted shape of Shell and Tube heat exchangers make them well suited for high pressure operations. The aim of this study is to experiment, validate and to provide design suggestion to optimize the shell and tube heat exchanger (STHE). The heat exchanger is made of acrylic material with 2 baffles and 7 tubes made of stainless steel. Hot fluid flows inside the tube and cold fluid flows over the tube in the shell. 4 K-type thermocouples were used to read the hot and cold fluids inlet and outlet temperatures. Experiments were carried out for various combinations of hot and cold water flow rates with different hot water inlet temperatures. The flow conditions are limited to the lab size model of the experimental setup. A commercial CFD code was used to study the thermal and hydraulic flow field inside the shell and tubes. CFD methodology is developed to appropriately represent the flow physics and the procedure is validated with the experimental results. Turbulent flow in tube side is observed for all flow conditions, while the shell side has laminar flow except for extreme hot water temperatures. Hence transition k-kl-omega model was used to predict the flow better for transition cases. Realizable k- epsilon model with non-equilibrium wall function was used for turbulent cases. Temperature and velocity profiles are examined in detail and observed that the flow remains almost uniform to the tubes thus limiting heat transfer. Approximately 2/3 rd of the shell side flow does not surround the tubes due to biased flow contributing to reduced overall heat transfer and increased pressure loss. On the basis of these findings an attempt has been made to enhance the heat transfer by inducing turbulence in the shel l side flow. The two baffles were rotated in opposite direction to each other to achieve more circulation in the shell side flow and provide more contact with tube surface. Various positions of the baffles were simulated and studied using CFD analysis and th e results are summarized with respect to heat transfer and pressure loss.


Sign in / Sign up

Export Citation Format

Share Document