Test Analysis of Stiffened T-Stub Connections

2015 ◽  
Vol 744-746 ◽  
pp. 319-322
Author(s):  
Chang Chun Dong ◽  
Wei Zhao

To investigate the effect of stiffener on the stiffness and strength of T-stubs, 3 T-stub connections without stiffeners and 6 stiffened T-stub connections with varied shape and thickness of stiffeners were tested monotonically. The load carrying capacity, relative deformations of endplates and strains on the stiffeners and endplates were measured. The load-deformation curves of the connections and load-strain curves were presented. The test results showed that the commonly used stiffeners in current Chinese practice often yield or/and buckle prematurely. And the stiffener designed by the method can meet the requirement in CECS102-2002, which demands that the stiffener should be able to force the extended portion of endplates from clamped-free boundary to plates fixed on two adjacent boundaries.

1987 ◽  
Vol 2 (3) ◽  
pp. 77-80 ◽  
Author(s):  
Marvin R. Pyles ◽  
Joan Stoupa

Abstract In order to quantify the stump anchor capacity of small second-growth Douglas-fir (Pseudotsuga menziesii [Mirb]. Franco) trees, load tests to failure were conducted on 18 stumps from trees 7 to 16.5 in dbh. The tests produced ultimate loads that varied as the square of the tree diameter. However, the ultimate load typically occurred at stump system deformations that were far in excess of that which would be considered failure of a stump anchor. A hyperbolic equation was used to describe the load-deformation behavior of each stump tested and was generalized to describe all the test results. West. J. Appl. For. 2(3):72-80, July 1987.


2019 ◽  
Vol 22 (13) ◽  
pp. 2755-2770
Author(s):  
Fuyun Huang ◽  
Yulong Cui ◽  
Rui Dong ◽  
Jiangang Wei ◽  
Baochun Chen

When casting wet concrete into hollow steel tubular arch during the construction process of a concrete-filled steel tubular arch bridge, an initial stress (due to dead load, etc.) would be produced in the steel tube. In order to understand the influence of this initial stress on the strength of the concrete-filled steel tubular arch bridge, a total of four single tubular arch rib (bare steel first) specimens (concrete-filled steel tubular last) with various initial stress levels were constructed and tested to failure. The test results indicate that the initial stress has a large influence on the ultimate load-carrying capacity and ductility of the arch structure. The high preloading ratio will reduce significantly the strength and ductility that the maximum reductions are over 25%. Then, a finite element method was presented and validated using the test results. Based on this finite element model, a parametric study was performed that considered the influence of various parameters on the ultimate load-carrying capacity of concrete-filled steel tubular arches. These parameters included arch slenderness, rise-to-span ratio, loading method, and initial stress level. The analysis results indicate that the initial stress can reduce the ultimate loading capacity significantly, and this reduction has a strong relationship with arch slenderness and rise-to-span ratio. Finally, a method for calculating the preloading reduction factor of ultimate load-carrying capacity of single concrete-filled steel tubular arch rib structures was proposed based on the equivalent beam–column method.


Geofluids ◽  
2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Xuezeng Liu ◽  
Yunlong Sang ◽  
Shuang Ding ◽  
Guiliang You ◽  
Wenxuan Zhu ◽  
...  

Cracks and other diseases may occur in the long-term operation of highway tunnels and reduce the structural load-carrying capacity. Strengthening using carbon fiber reinforced polymer (CFRP) sheets and other materials could extend the service time of the tunnels. However, the process of strengthening tunnels is remarkably different from the process of strengthening aboveground structures because of the secondary load. In order to understand the development of stress and deformation of strengthened tunnels under secondary load, a 1 : 10 scaled model was tested to simulate the tunnel strengthened with CFRP under different damage states. The test results show that CFRP strengthening improved the stiffness of the structure and inhibited the propagation of the existing cracks. The peeling of the CFRP sheets made the strengthened structure quickly lose its load-carrying capacity, causing the instability of the structure. The failure loads of the structures strengthened at different damage states were essentially the same, with an average value of 184% of the original failure load. Nevertheless, the early strengthening helped control the structural deformation. The test results also demonstrate that the bonding strength between the CFRP and the lining is essential for strengthening effectiveness. This study provides a theoretical basis for similar engineering reinforcement designs.


Materials ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 5525
Author(s):  
Antonin Lokaj ◽  
Pavel Dobes ◽  
Oldrich Sucharda

This article presents the results of static tests on bolted connections in squared and round timber with inserted steel plates. The experiment evaluates structural timber connections with different distances between the fastener and the loaded end at different moisture contents. Specimens were loaded by tension parallel to the grain and load–deformation diagrams were recorded. Fifty-six specimens with three different distances between the fastener and the loaded end, at different moisture contents, were tested. The results were statistically evaluated using regression analysis, complemented with load–deformation curves, and compared with calculations according to the valid standard for design of timber structures. A decrease in the evaluated load-carrying capacity with increasing moisture content was confirmed experimentally. A slight increase in the evaluated load-carrying capacity with increasing fastener distance from the loaded end was found.


2015 ◽  
Vol 816 ◽  
pp. 461-468 ◽  
Author(s):  
Pavel Lekomtsev ◽  
Pavol Božek ◽  
Alexander Romanov ◽  
Andrey Abramov ◽  
Ivan Abramov ◽  
...  

Test results of axial shift of “technical ceramics - glass” parts in taper interference fit joint under axial loading are presented. The load-carrying capacity was tested under normal conditions; a servo press was used to load the test samples. The tested samples were assembled by thermal method.


1986 ◽  
Vol 108 (1) ◽  
pp. 127-134 ◽  
Author(s):  
Y. Terauchi ◽  
H. Nadano ◽  
M. Kohno

In trying to clarify the effect of molybdenum disulfide film on the scoring resistance and the wear characteristics of gears, various tests on balls and gears coated with MoS2 film have been run. From the test results obtained with a four-ball machine and a power-circulating gear machine it was found that the effect of the MoS2 film was small on the seizure load of the balls. In contrast, the effect of the MoS2 film on the scoring resistance of the gears was significant, and the development of the gears of which the load-carrying capacity against scoring is considerably large could be made.


2020 ◽  
Vol 11 (1) ◽  
pp. 105
Author(s):  
In-Rak Choi ◽  
Chang-Soo Kim

To investigate the behavior of various steel anchors, push-out tests were performed for 13 test specimens. Test parameters included the geometry of beams (wide-flange beams and composite beams) and the type of steel anchors (stud anchors and Z- and C-channel anchors with full- or partial-length welding). Test results showed that the performance of test specimens strongly depends on the types of steel anchors rather than the geometry of steel beams. The specimens with C-channel anchors showed the highest load-carrying capacity but the most drastic load reduction after the peak load. The specimens with Z-channel anchors showed a similar behavior to those with C-channel anchors but the load reduction occurred at a slightly slower rate. The load-carrying capacity was increased with the length of the Z- and C-channel anchors. The specimens with stud anchors reached the peak load at a slow rate and showed the most ductile behavior. The test results were compared with predictions by various design equations for steel anchors available in the literature, and the existing design equations for channel anchors with partial-length welding were considered applicable to design.


Author(s):  
Eva-Maria Mautner ◽  
Werner Sigmund ◽  
Johann-Paul Stemplinger ◽  
Karsten Stahl

Within a research project, experimental investigations of large-sized worm gears (pairing steel worm with bronze worm wheel) with centre distance a = 315 mm are carried out. The primary aim is to gain verified knowledge regarding load-carrying capacity and efficiency for this worm gear size. The paper describes the conducted tests in detail and shows basic examples of experimental test results. In the course of these investigations, an overall worm gearbox efficiency of up to η = 96% is measured.


2008 ◽  
Vol 2 (1) ◽  
pp. 065-078
Author(s):  
Marta Słowik

Slightly reinforced concrete members are the members made by concrete with reinforcement less than minimum given in codes for reinforced concrete ones. Plain concrete and slightly reinforced concrete members in bending are treated in the same way during the dimensioning and the influence of longitudinal reinforcement on the load carrying capacity is not taken into account. The mechanism of work and crack formation in slightly reinforced concrete members is not completely recognized. The author’s own research program was made. The experiment was aimed at the determination of cracking moment and load carrying capacity of slightly reinforced concrete beams with different reinforcement ratio. Also plain concrete beams and the typical reinforced concrete beam were tested. The analysis of the obtained values of maximum bending moment and crack’s widths was made according to the reinforcement ratio. The analysis of test results shows how the presence of longitudinal steel bars in concrete members, even when reinforcement ratio is low, changes cracking process and influences the value of cracking moment in flexural members. On the basis of test results, the method how to calculate the load carrying capacity of slightly reinforced concrete elements in bending has been proposed.


2019 ◽  
Vol 26 (1) ◽  
pp. 9-19
Author(s):  
Mazin B. Abdulrahman ◽  
Husham M. Rashid

In modern buildings, transverse openings are often used beams for the purpose of supplying and service pipes. Due to the presence of the openings in the concrete beams lead to the formation of cracks around the openings due to the stresses concentration in a small area above and below of the opening. The repairing, maintenance, and upgrading of structural members, are maybe one of the most pivotal problems in civil engineering applications. In this research, an experimental work is conducted to study the behavior of the reinforced RPC T-beams that containing openings and repair this beams using CFRP strips. The Experimental program of the present study includes two parts, the first part includes testing of seven reinforced reactive powder concrete RPC T-beams, which casted and tested, one beam is without opening as a reference beam and the rest, were provided with an opening. and these beams are divided into two groups. The first group was used to study the effect of the openings shape (circular and square) and the second group was used to study the effect of the openings locations, which consists three locations (Lc/2, Lc/3 and Lc/4).These are measured from the support center to the openings center. While the second part including a repaired all beams in the first part the using carbon fiber polymer. The test results indicated that the presence of openings in the beams web caused a reduction in the reinforced RPC T-beams ultimate load carrying capacity with about (10-55)%, Also lead to increasing in deflection compared to control beam before repairing at same loading. Studying the shape effect showed that the beams with square openings have average ultimate load carrying capacity lower by 36% compared with the control beams.While beams with containing circular openings have average ultimate load carrying capacity lower 29%. From the test results, it could be concluded that the presence of the openings in the shear region led to a decrease in ultimate load carrying capacity a about 38% to 49% for opening of opening at (Lc/3 and Lc/4) respectively. While the presence of openings in the flexural region led to a decrease in the ultimate load carrying capacity rate of 11%. Related to the repairing study part it was found that the average ultimate load carrying capacity for repairing beams was 103% compared with the not repaired beams.


Sign in / Sign up

Export Citation Format

Share Document