Infuence of Nitrogen Gas Flow Rate on Nitrogenated Amorphous Carbon Film for Solar Cell Applications

2015 ◽  
Vol 1109 ◽  
pp. 138-142
Author(s):  
A. Ishak ◽  
Mohd Firdaus Malek ◽  
Mohamad Hafiz Mamat ◽  
Mohamad Rusop

In this paper, the effect of nitrogen gas flow rate on electrical and electronic properties of nitrogen doped amorphous carbon film (a-C:N) by the use of constant +50 V is presented. The flow-rate of nitrogen gas into the furnace was influenced the resistivity as well as conductivity a-C:N film. The resistivity and conductivity of a-C:N films deposited at high nitrogen flow-rate (200 mL/min) produced low resistivity and high conductivity under deposition condition used. The highest resistivity (4.97x107 Ω.cm) and lowest resistivity (2.81x101 Ω.cm) is found at 0 mL/min (undoped) and 200 mL/min. The fabricated solar cell device with the configuration of Au/n-C:N/p-Si/Au for undoped (0 mL/min) and nitrogen doped (200 mL/min) achieved efficiency (𝜂) 0.00111% and 0.00120 %, respectively.

2015 ◽  
Vol 1734 ◽  
Author(s):  
Kento Nakanishi ◽  
Jun Otsuka ◽  
Masanori Hiratsuka ◽  
Chen Chung Du ◽  
Akira Shirakura ◽  
...  

ABSTRACTDiamond-like carbon (DLC) has widespread attention as a new material for its application to thin film solar cells and other semiconducting devices. DLC can be produced at a lower cost than amorphous silicon, which is utilized for solar cells today. However, the electrical properties of DLC are insufficient for this purpose because of many dangling bonds in DLC. To solve this problem, we investigated the effects of the fluorine incorporation on the structural and electrical properties of DLC.We prepared five kinds of fluorinated DLC (F-DLC) thin film with different amounts of fluorine. Films were deposited by the radio-frequency plasma enhanced chemical vapor deposition (RF-PECVD) method. C6H6 and C6HF5 were used as source gases. The total gas flow rate was constant and the gas flow rate ratio R (=C6H6 / (C6H6 + C6HF5)) was changed from 0 to 1 in 0.25 ratio steps. We also prepared nitrogen doped DLC (F-DLC) on p-Si using N2 gas as a doping gas to form nitrogen doped DLC (F-DLC) / p-Si heterojunction diodes.X-ray photoelectron spectroscopy (XPS) showed that fluorine concentration in the DLC films was controlled. Moreover, the XPS analysis of the C1s spectrum at R=2/4 showed the presence of CF bonding. At R=1, CF2 bonding was observed in addition to CF bonding. The sheet resistivity of the films changed from 3.07×1012 to 4.86×109 Ω. The minimum value was obtained at R=2/4. The current-voltage characteristics indicated that nitrogen doped F-DLC of 2/4 and p-Si heterojunction diode exhibited the best rectification characteristics and its energy conversion efficiency had been maximized. This is because of a decrease of dangling bonds density by ESR analysis and an increase of sp2 structures by Raman analysis. When the fluorine is over certain content, the sheet resistivity increases because chain structures become larger, which is due to the CF2 bonding in F-DLC prevents ring structures. Many C2F4 species were observed and it may become precursors of the chain structure domains, such as (CF2)n.In this study, we revealed effects of fluorine incorporation on DLC and succeeded in increasing its conductivity and improving rectification characteristics of DLC/ p-Si hetero-junction diodes. Our results indicate that DLC fluorination is effective for the semiconducting material, such as solar cell applications.


2020 ◽  
Vol 860 ◽  
pp. 190-195
Author(s):  
Irma Septi Ardiani ◽  
Khoirotun Nadiyyah ◽  
Anna Zakiyatul Laila ◽  
Sarayut Tunmee ◽  
Hideki Nakajima ◽  
...  

Amorphous carbon films have been explored and used in a wide variety of applications. With the n-type and p-type amorphous carbon film, it can be used to make p-n junctions for solar cells. This research aims to study the structure of boron- and nitrogen-doped amorphous carbon (a-C:B and a-C:N) films. This research uses the basic material of bio-product from palmyra sugar to form amorphous carbon. Amorphous carbon was synthesized by heating the palmyra sugar at 250°C. The results of XRD showed that the doped films produce an amorphous carbon phase. PES was used to analyze the bonding state of dopants in the sample. B4C, BC3, and BC2O bonds formed in a-C:B, while pyridine and pyrrolic formed in a-C:N.


MRS Advances ◽  
2018 ◽  
Vol 3 (3) ◽  
pp. 165-170
Author(s):  
Shumpei Ogawa ◽  
Tatsuya Kuroda ◽  
Ryuga Koike ◽  
Hiroki Ishizaki

AbstractRecently, Plasma Assisted Atomic Layer Deposition Technique will easily control the thickness and the composition of semiconductor films. The radical generated by using the plasma techniques, gave the decrease of the defect into the semiconductor films. In this investigation, the relationship between microwave plasma power, nitrogen gas flow rate and concentration of generated nitrogen radical, was evaluated. At the first, Plasma emission spectrum at microwave plasma power (0 to 400W) was measured using a mixed 200sccm argon gas and 10sccm nitrogen gas. Next, the plasma emission spectrum was measured in the mixing of nitrogen gas flow rate (0 to 40sccm) with 200sccm argon gas flow rate. At that time, the microwave plasma power was set to 200W. Nitrogen radical spectrum were identified from all the emission spectrum, and the nitrogen radical intensity was calculated. As a result, the nitrogen radical intensity became the largest at 200sccm argon gas flow rate and 10sccm nitrogen gas flow rate. In addition, the nitrogen radical intensity increased in proportion to the microwave plasma power. The concentration of generated nitrogen radical could be controlled by changing the microwave plasma power and the nitrogen gas flow rate. Mentioned above, nitride thin films will be obtained on Si Substrates by microwave generated remote plasma assisted atomic layer deposition technique.


2016 ◽  
Vol 78 (5-10) ◽  
Author(s):  
Arman Shah ◽  
S. Izman ◽  
M. A. Hassan

Cathodic arc physical vapor deposition (CAPVD) is one of the promising techniques that have a potential to coat titanium nitride (TiN) on biomedical implants due to its good adhesion and high evaporation rate. However, this method emits microdroplets which have the possible detrimental effect on the coating performance. Past studies indicated that micro droplets can be controlled through proper deposition parameters. In the present work, an attempt was made to study the effect of nitrogen gas flow rates (100 to 300 sccm) on TiN coating of the Ti-13Zr-13Nb biomedical alloy. Scanning electron microscopy (SEM) was used to evaluate surface morphology and coating thickness while crystal phase of the coated substrates was determined using X-Ray Diffraction (XRD). Image analysis software was employed to quantify microdroplets counts. Results show that higher nitrogen gas flow rate able to decrease a significant amount of microdroplets and concurrently increase the thickness of TiN coating. A mixed crystal planes of (111) and (220) are obtained on the coated substrates at this setting which exhibits denser structure with higher adhesion strength as compared to substrates coated at the lower N2 gas flow rate.


2015 ◽  
Vol 28 ◽  
pp. 37-44 ◽  
Author(s):  
Ling Wei Low ◽  
Tjoon Tow Teng ◽  
Abbas F.M. Alkarkhi ◽  
Norhashimah Morad ◽  
Baharin Azahari

2008 ◽  
Vol 17 (7-10) ◽  
pp. 1724-1727 ◽  
Author(s):  
Dilip C. Ghimire ◽  
S. Adhikari ◽  
H.R. Aryal ◽  
S.M. Mominuzzamn ◽  
T. Soga ◽  
...  

2010 ◽  
Vol 636-637 ◽  
pp. 965-970
Author(s):  
Mubarak Ali ◽  
E. Hamzah ◽  
I.A. Qazi ◽  
M.R.M. Toff

In the present study, titanium nitride coatings on tool steel were deposited using cathodic arc physical vapour deposition technique. We studied and discussed the effect of various nitrogen gas flow rate on the surface properties of TiN-coated steel. The coating properties investigated in this work include the surface morphology, surface roughness, line profile and fractal dimension analyses using atomic force microscope. Minimum values for surface roughness, line profile and fractal dimension analyses were recorded at nitrogen gas flow rate of 200 sccm. This is mainly because of the reduction in macro-droplets and minimization of the growth defects, usually produced during etching and deposition stages. Critical limit of nitrogen gas flow rate in TiN coatings were identified and considered an important aspect to understand the performance of TiN PVD-coated steel.


2005 ◽  
Vol 12 (04) ◽  
pp. 631-643 ◽  
Author(s):  
ALI MUBARAK ◽  
ESAH BINTI HAMZAH ◽  
MOHD RADZI HJ. MOHD TOFF ◽  
ABDUL HAKIM BIN HASHIM

Cathodic arc evaporation (CAE) is a widely-used technique for generating highly ionized plasma from which hard and wear resistant physical vapor deposition (PVD) coatings can be deposited. A major drawback of this technique is the emission of micrometer-sized droplets of cathode material from the arc spot, which are commonly referred to as "macroparticles." In present study, titanium nitride ( TiN ) coatings on high-speed steel (HSS) coupons were produced with a cathodic arc evaporation technique. We studied and discussed the effect of various nitrogen gas flow rates on microstructural and mechanical properties of TiN -coated HSS coupons. The coating properties investigated in this work included the surface morphology, thickness of deposited coating, adhesion between the coating and substrate, coating composition, coating crystallography, hardness and surface characterization using a field emission scanning electron microscope (FE-SEM) with energy dispersive X-ray (EDX), X-ray diffraction (XRD) with glazing incidence angle (GIA) technique, scratch tester, hardness testing machine, surface roughness tester, and atomic force microscope (AFM). An increase in the nitrogen gas flow rate showed decrease in the formation of macro-droplets in CAE PVD technique. During XRD-GIA studies, it was observed that by increasing the nitrogen gas flow rate, the main peak [1,1,1] shifted toward the lower angular position. Surface roughness decreased with an increase in nitrogen gas flow rate but was higher than the uncoated polished sample. Microhardness of TiN -coated HSS coupons showed more than two times increase in hardness than the uncoated one. Scratch tester results showed good adhesion between the coating material and substrate. Considerable improvement in the properties of TiN -deposited thin films was achieved by the strict control of all operational steps.