Research of On-Line Large-Size Forging Measurement System Based on LabVIEW

2012 ◽  
Vol 430-432 ◽  
pp. 1577-1580
Author(s):  
Xian Ling Zhao ◽  
Jian Sheng Liu

Forging temperature is usually around 1000°C in free forging scene. Manual measurement leads to large measurement errors. Adopting the non-contact 3D scanning technology, make the laser beam sweep across the forging surface to get three-dimensional coordinates of the points on the forging surface in space. Neighboring scan points separate by less than 0.25mm. The measurement error is less than 6mm. The coordinate,s data are sent to the LabVIEW procedure. The procedure analyzes the coordinates to calculate the size of the large-size forging to realize automatic measurement of the forgings. The procedure can also reconstruct the image of the large-size forging. These make us detect the real-time changes of the forging far from the free forging scene.

1995 ◽  
Vol 117 (1) ◽  
pp. 27-40 ◽  
Author(s):  
Frans C. T. van der Helm ◽  
Gijs M. Pronk

A measurement technique is presented for recording positions of the bones of the shoulder mechanism, i.e., thorax, clavicula, scapula and humerus, in 3-D space, based on palpating and recording positions of bony landmarks. The palpation technique implies that only static positions can be measured. Accuracy of retrieving bony landmarks is checked on-line using rigid body assumptions. The measurement error is calculated afterwards and is comparable with cinegraphic methods. Axial rotation of the clavicula is estimated by minimizing rotations in the acromioclavicular joint. A number of motion definitions is compared by means of interindividual variation and subjective interpretability. Two useful definitions are proposed for describing motions of the shoulder mechanism. Four conditions have been recorded: abduction and anteflexion of the humerus both with and without additional weight in the hand. Abduction and anteflexion result in large differences in scapular and clavicular motions. The effect of additional weight in the hand on the position of the shoulder girdle is negligible.


2013 ◽  
Vol 552 ◽  
pp. 271-275
Author(s):  
Jin Song Wang ◽  
Jian Liu ◽  
Li Juan Li ◽  
Shan Liu ◽  
Zhi Yong An

In this paper a new three-dimensional large-size optical measurement system by laser radar has been proposed in combination of double-optic circuit measuring technology, ultra-high frequency modulation technology and laser intellectual tracing and location technology. The system can measure 3d shape unconnectedly for lager-size object, which has the advantages of high accuracy, automatic measurement and freedom from being influenced by material and light ray.


Author(s):  
Neil Rowlands ◽  
Jeff Price ◽  
Michael Kersker ◽  
Seichi Suzuki ◽  
Steve Young ◽  
...  

Three-dimensional (3D) microstructure visualization on the electron microscope requires that the sample be tilted to different positions to collect a series of projections. This tilting should be performed rapidly for on-line stereo viewing and precisely for off-line tomographic reconstruction. Usually a projection series is collected using mechanical stage tilt alone. The stereo pairs must be viewed off-line and the 60 to 120 tomographic projections must be aligned with fiduciary markers or digital correlation methods. The delay in viewing stereo pairs and the alignment problems in tomographic reconstruction could be eliminated or improved by tilting the beam if such tilt could be accomplished without image translation.A microscope capable of beam tilt with simultaneous image shift to eliminate tilt-induced translation has been investigated for 3D imaging of thick (1 μm) biologic specimens. By tilting the beam above and through the specimen and bringing it back below the specimen, a brightfield image with a projection angle corresponding to the beam tilt angle can be recorded (Fig. 1a).


Author(s):  
W.J. de Ruijter ◽  
Sharma Renu

Established methods for measurement of lattice spacings and angles of crystalline materials include x-ray diffraction, microdiffraction and HREM imaging. Structural information from HREM images is normally obtained off-line with the traveling table microscope or by the optical diffractogram technique. We present a new method for precise measurement of lattice vectors from HREM images using an on-line computer connected to the electron microscope. It has already been established that an image of crystalline material can be represented by a finite number of sinusoids. The amplitude and the phase of these sinusoids are affected by the microscope transfer characteristics, which are strongly influenced by the settings of defocus, astigmatism and beam alignment. However, the frequency of each sinusoid is solely a function of overall magnification and periodicities present in the specimen. After proper calibration of the overall magnification, lattice vectors can be measured unambiguously from HREM images.Measurement of lattice vectors is a statistical parameter estimation problem which is similar to amplitude, phase and frequency estimation of sinusoids in 1-dimensional signals as encountered, for example, in radar, sonar and telecommunications. It is important to properly model the observations, the systematic errors and the non-systematic errors. The observations are modelled as a sum of (2-dimensional) sinusoids. In the present study the components of the frequency vector of the sinusoids are the only parameters of interest. Non-systematic errors in recorded electron images are described as white Gaussian noise. The most important systematic error is geometric distortion. Lattice vectors are measured using a two step procedure. First a coarse search is obtained using a Fast Fourier Transform on an image section of interest. Prior to Fourier transformation the image section is multiplied with a window, which gradually falls off to zero at the edges. The user indicates interactively the periodicities of interest by selecting spots in the digital diffractogram. A fine search for each selected frequency is implemented using a bilinear interpolation, which is dependent on the window function. It is possible to refine the estimation even further using a non-linear least squares estimation. The first two steps provide the proper starting values for the numerical minimization (e.g. Gauss-Newton). This third step increases the precision with 30% to the highest theoretically attainable (Cramer and Rao Lower Bound). In the present studies we use a Gatan 622 TV camera attached to the JEM 4000EX electron microscope. Image analysis is implemented on a Micro VAX II computer equipped with a powerful array processor and real time image processing hardware. The typical precision, as defined by the standard deviation of the distribution of measurement errors, is found to be <0.003Å measured on single crystal silicon and <0.02Å measured on small (10-30Å) specimen areas. These values are ×10 times larger than predicted by theory. Furthermore, the measured precision is observed to be independent on signal-to-noise ratio (determined by the number of averaged TV frames). Obviously, the precision is restricted by geometric distortion mainly caused by the TV camera. For this reason, we are replacing the Gatan 622 TV camera with a modern high-grade CCD-based camera system. Such a system not only has negligible geometric distortion, but also high dynamic range (>10,000) and high resolution (1024x1024 pixels). The geometric distortion of the projector lenses can be measured, and corrected through re-sampling of the digitized image.


1996 ◽  
Vol 33 (1) ◽  
pp. 311-323 ◽  
Author(s):  
A. Witteborg ◽  
A. van der Last ◽  
R. Hamming ◽  
I. Hemmers

A method is presented for determining influent readily biodegradable substrate concentration (SS). The method is based on three different respiration rates, which can be measured with a continuous respiration meter which is operated in a cyclic way. Within the respiration meter nitrification is inhibited through the addition of ATU. Simulations were used to develop the respirometry set-up and decide upon the experimental design. The method was tested as part of a large measurement programme executed at a full-scale plant. The proposed respirometry set-up has been shown to be suitable for a semi-on-line determination of an influent SS which is fully based on the IAWQ #1 vision of the activated sludge process. The YH and the KS play a major role in the principle, and should be measured directly from the process.


2017 ◽  
Vol 928 (10) ◽  
pp. 58-63 ◽  
Author(s):  
V.I. Salnikov

The initial subject for study are consistent sums of the measurement errors. It is assumed that the latter are subject to the normal law, but with the limitation on the value of the marginal error Δpred = 2m. It is known that each amount ni corresponding to a confidence interval, which provides the value of the sum, is equal to zero. The paradox is that the probability of such an event is zero; therefore, it is impossible to determine the value ni of where the sum becomes zero. The article proposes to consider the event consisting in the fact that some amount of error will change value within 2m limits with a confidence level of 0,954. Within the group all the sums have a limit error. These tolerances are proposed to use for the discrepancies in geodesy instead of 2m*SQL(ni). The concept of “the law of the truncated normal distribution with Δpred = 2m” is suggested to be introduced.


2020 ◽  
Vol 13 (12) ◽  
pp. e239286
Author(s):  
Kumar Nilesh ◽  
Prashant Punde ◽  
Nitin Shivajirao Patil ◽  
Amol Gautam

Ossifying fibroma (OF) is a rare, benign, fibro-osseous lesion of the jawbone characterised by replacement of the normal bone with fibrous tissue. The fibrous tissue shows varying amount of calcified structures resembling bone and/or cementum. The central variant of OF is rare, and shows predilection for mandible among the jawbone. Although it is classified as fibro-osseous lesion, it clinically behaves as a benign tumour and can grow to large size, causing bony swelling and facial asymmetry. This paper reports a case of large central OF of mandible in a 40-year-old male patient. The lesion was treated by segmental resection of mandible. Reconstruction of the surgical defect was done using avascular fibula bone graft. Role of three-dimensional printing of jaw and its benefits in surgical planning and reconstruction are also highlighted.


Polymers ◽  
2021 ◽  
Vol 13 (9) ◽  
pp. 1358
Author(s):  
Taihui Wu ◽  
Jianshe Ma ◽  
Chengchen Wang ◽  
Haibei Wang ◽  
Liangcai Cao ◽  
...  

An optical encryption method based on computer generated holograms printing of photopolymer is presented. Fraunhofer diffraction is performed based on the Gerchberg-Saxton algorithm, and a hologram of the Advanced Encryption Standard encrypted Quick Response code is generated to record the ciphertext. The holograms of the key and the three-dimensional image are generated by the angular spectrum diffraction algorithm. The experimental results show that large-size encrypted Quick Response (QR) code and miniature keys can be printed in photopolymers, which has good application prospects in optical encryption. This method has the advantages of high-density storage, high speed, large fault tolerance, and anti-peeping.