scholarly journals Pulp tissue dissolution capacity of QMix 2in1 irrigation solution

2015 ◽  
Vol 09 (03) ◽  
pp. 423-427 ◽  
Author(s):  
Dilara Arslan ◽  
Mehmet Burak Guneser ◽  
Alper Kustarci ◽  
Kursat Er ◽  
Seyda Herguner Siso

ABSTRACT Objective: The aim of this study was to evaluate the tissue dissolution efficacy of four root canal irrigation solutions (sodium hypochlorite [NaOCl], chlorhexidine gluconate [CHX], Octenidine [OCT], and QMix 2in1) on bovine pulp tissue. Materials and Methods: Fifty bovine pulp tissue samples, each weighing 6.55 mg, were prepared and randomly divided into four experimental groups and one control group (n = 10) according to the dissolution irrigants used: (1) 5.25% NaOCl group; (2) 2% CHX group; (3) OCT group; (4) QMix 2in1 group; and (5) control group (saline solution). These samples were then placed into special bovine dentin reservoir models and immersed for 1 h with each test solution (0.1 mL of each) at room temperature. The pulp samples were then blotted dry and weighed again. The percentage of weight loss was calculated. Statistically analyzed with one-way analysis of variance and post-hoc Tukey tests (P = 0.05). Results: Saline solution did not dissolve the bovine pulp tissue. All groups, except OCT, dissolved pulp samples more effectively than the control group (P < 0.05). The highest tissue dissolution was observed in 5.25% NaOCl group (P < 0.05). No statistically significant difference was found between the tissue-dissolving effect between QMix 2in1 and those of 2% CHX. Conclusions: Within the limitations of this in vitro study, NaOCl exhibited the best tissue-dissolving effect out of all solutions tested. CHX and QMix 2in1 were able to dissolve pulp tissue but less than NaOCl. OCT and saline solutions could not exhibit significantly tissue-dissolving effectiveness. This study shown that QMix 2in1 has little capacity to dissolve pulp tissue therefore used alone is not sufficient for this purpose.

2017 ◽  
Vol 11 (02) ◽  
pp. 157-161 ◽  
Author(s):  
Bertan Kesim ◽  
Burak Sagsen ◽  
Tugrul Aslan

ABSTRACT Objective: The aim of this study was to compare the incidence of root cracks after root canal instrumentation with thermomechanically processed nickel-titanium (Ni-Ti) files with different instrumentation kinematics. Materials and Methods: A total of 150 extracted mandibular premolars with mature apices and straight root canals were divided into five groups and used in this study. In Group 1, 30 teeth were prepared using hand K-files and assigned to control group, Group 2 was instrumented using K3XF Rotary files (SybronEndo, Glendora, CA, USA) with continuous rotary motion. The teeth in Group 3 were instrumented by ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland) rotary files which make asymmetric rotary motion, In Group 4, teeth were instrumented by RECIPROC (VDW, Munich, Germany) with reciprocation motion and in Group 5, teeth were instrumented by Twisted File (TF) Adaptive (SybronEndo, Orange, CA, USA) files that use combination of continuous rotation and reciprocation motion (n = 30/per group). All the roots were horizontally sectioned 3, 6, and 9 mm from the apex with a low speed saw under water cooling. Then, the slices were examined through a stereomicroscope to determine the presence of dentinal microcracks.Results: For the apical (3-mm) and coronal (9-mm) sections, the ProTaper Next and TF Adaptive produced significantly more cracks than the hand files, RECIPROC, and K3XF (P < 0.05). There was no significant difference between the experimental groups and control group at the 6-mm level (P > 0.05). Conclusions: Within the limitations of this in vitro study, all thermal-treated Ni-Ti instruments and hand files caused microcracks in root canal dentin.


2020 ◽  
Vol 53 (2) ◽  
pp. 71
Author(s):  
Nanik Zubaidah ◽  
Agus Subiwahjudi ◽  
Dinda Dewi Artini ◽  
Karina Erda Saninggar

Background: A successful root canal treatment eliminates pathogenic bacteria from infected root canals. The most common bacteria in root canal infections is Enterococcus faecalis (E. faecalis), due to its resistance to medicament and root canal irrigation. A photodynamic therapy (PDT) is a method of root canal disinfection that uses a combination of photosensitisers and light activation to eliminate bacteria in the root canal. The duration of the PDT irradiation results in the production of singlet oxygen and reactive oxygen species (ROS) to eliminate the E. faecalis bacteria. Purpose: To analyse the differences in the duration exposure of photodynamic therapy against the E. faecalis bacteria. Methods: The E. faecalis bacteria culture was divided into seven eppendorf tubes. Group I was a control group, and group II, III, IV, V, VI and VII were treated using PDT consisting of Toluidine Blue O (TBO) photosensitiser and light source irradiation for ten, 20, 30, 40, 50 and 60 seconds, respectively. After incubation, the number of bacteria was calculated by the Quebec Colony Counter and analysed using the Kruskal–Wallis test and the Mann–Whitney test (p <0.05). Results: There was a significant difference between the number of E. faecalis bacteria colonies in each treatment group (p <0.05). Group VI and VII, which had a longer exposure to PDT, showed a smaller amount of E. faecalis bacteria. Conclusion: The longer exposure of PDT results in a smaller amount of E. faecalis bacteria. The light irradiation of 50 seconds is the most effective to eliminate E. faecalis bacteria.


2018 ◽  
Vol 7 (2) ◽  
pp. 28-31
Author(s):  
Varunjeet Chaudhary ◽  
Sanad Singh Solanki ◽  
Varsha Yadav ◽  
Seema Lahoti

Objective: To evaluate the shear bond strength of stainless steel brackets bonded with fluoride-releasing composite resins, comparing effect of adhesion booster and conventional primer.Materials & Method: Sixty extracted premolars were subjected to bracket bonding with fluoride-releasing composite resin; which were bonded by randomly divided into two groups of bonding agents: Group 1- conventional primer as control group, Group 2- adhesion booster. After bonding, the samples were thermocycled (500 cycles) at 5ºC and 55ºC temperatures. After 48 hours they were subjected to shear bond strength testing in occluso-gingival direction, using an MTS 810 Universal Testing Machine with load speed of 0.5 mm/min.Result: Mean shear bond strength was significantly more in samples bonded with adhesion booster (14.792±3.805 Mpa) as compared to conventional primers (11.327±4.047 Mpa). There was statistically significant difference in shear bond strength between the groups (p=0.001).Conclusion: The use of the adhesion booster significantly increased the bond strength of bracket bonded with fluoride-releasing composite.


2008 ◽  
Vol 02 (02) ◽  
pp. 086-090 ◽  
Author(s):  
Hale Ară ◽  
Nazmiye Dönmez ◽  
Sema Belli

ABSTRACTObjectives: The purpose of this in vitro study was to evaluate the effect of artificial saliva contamination on microtensile bond strength to pulp chamber dentin.Methods: Clearfil SE Bond (SEB) (Kuraray, JAPAN) adhesive system and Clearfil Photo Posterior (CPP) (Kuraray, JAPAN) composite resin were used. Twenty extracted caries-free human molar teeth were randomly distributed into four groups. Apart from a control group without contamination (Group 1), primed dentin surfaces were contaminated with artificial saliva (10 s), rinsed, dried, reprimed and bonded (Group 2), coated with adhesive, contaminated with artificial saliva, rinsed, dried, bonding procedures were repeated (Group 3), coated with adhesive, light cured, contaminated with saliva, rinsed, dried, treated with SE primer (SEP) and SEB (Group 4).After 24 hrs, the teeth were prepared for microtensile bond testing and tensile bond strength was measured (1mm/min). The data was calculated as MPa and analyzed using one-way ANOVA and Duncan test (P<.05).Results: The results indicated that Group 2 showed lowest bond strength when compared to the others (P<.05). No statistically significant difference was found between Groups 3 and 4 (P>.05).Conclusions: It was concluded that contamination during priming procedure has a negative effect on bond strength (P<.05). Although contamination of the uncured adhesive was not critical in this study (P>.05) any kind of contamination of the bonding area should, in principle, be avoided. (Eur J Dent 2008;2:86-90)


Author(s):  
Rathika Rai ◽  
M. A. Easwaran ◽  
K. T. Dhivya

Aim: To evaluate the surface detail reproduction of dental stone this is immersed in different disinfectant solution and studied under stereomicroscope. Methodology: Total number of 30 specimens of dental stone (Type III) were made with measurements of 1.5cm diameter and 1cm height .This samples are divided in to 3 groups group A,B,C. were A is immersed in Distilled water which was taken as control group ;B is immersed in 2% Glutaraldehyde and C is immersed in 5%sodium hypochlorite. Each specimen were immersed in the disinfectant solution for 15 minutes and dried under room temperature for 24 hrs. After 24 hrs each specimens are studied under stereomicroscope for surface details. Result: The results showed no significant difference in the surface irregularities and porosities for a group 1 and group 2 except group 3 which showed significant increase in the porosities, surface irregularities and erosions after disinfection with 5% NaHOCl by immersion method. Conclusion: The surface detail reproduction capacity of die stone was adversely affected when 5% Sodium hypochlorite was used as disinfectant solution when compare d to control group and 2% Glutaraldehyde


2019 ◽  
Vol 36 (01) ◽  
pp. 046-050
Author(s):  
Alireza Taghdisi ◽  
Sajjad Hejazi

Introduction Increasing the immune system's function of fighting infectious diseases is very important in the poultry industry. Ginger, scientifically known as Zingiber officinale, belongs to the Zingiberaceae family. The use of ginger in the diet of poultry increases serum levels of superoxide dismutase enzymes and glutathione peroxidase, which are considered to be important antioxidant enzymes. The main objective of the present study is to evaluate the effect of ginger on the spleen tissue of broiler chickens. Material and Methods The specimens comprised 2 groups of 20 Ross breed broiler chicks, for 42 days and were then, examined and tested. The diet was supplemented with 1 g/kg of ginger powder from the beginning of the rearing period. Blood samples of the chicks were randomly collected to measure the levels of hemagglutination (HI). The removed spleens were fixed with 10% formalin buffer. The specimens were cut in 5-micron diameters and stained with hematoxylin and eosin. Results and Conclusion There was a statistically significant difference in the mean of HI blood titers between the chicks in the growth period and final period groups (p < 0.05). The white-pulp tissue samples were more clearly seen in the treatment group than in the control group, and also, it was observed that the wall of the central artery of the white pulp was thicker in the ginger-treated group as compared with the control group. The nutritional value of ginger may vary. Thus, it is necessary to investigate the effect of this plant final on weight gain; the serum factors associated with the metabolic chart, and the response of the immune system to this plant.


2015 ◽  
Vol 85 (6) ◽  
pp. 920-926 ◽  
Author(s):  
Ricardo Carvalho Bueno ◽  
Roberta Tarkany Basting

ABSTRACT Objective:  To evaluate the proliferation and morphology of human osteoblasts cultured on two brands of mini-implants after 24, 48, and 72 hours, in addition to the chemical composition found on their surface. Materials and Methods:  Two brands of mini-implant (Morelli and Neodent) were evaluated; polystyrene was used as a control group (n  =  3). Osteoblasts were cultured on the surface of sterilized mini-implants in a CO2 incubator at different time periods (24, 48, and 72 hours). Osteoblast proliferation was quantified by scanning electron microscopy using up to 5000× magnification, and cell morphology was analyzed by a single observer. For the chemical analysis, spectroscopy X-ray fluorescence was used to identify and quantify chemical components on the surface of the mini-implants. Results:  Two-way ANOVA showed no significant interaction between the factors studied (P  =  0.686). A Tukey test revealed no significant difference in osteoblast proliferation between the mini-implants at all studied periods; however, a difference in cell proliferation was detected between the Neodent and the control group (P  =  .025). For all groups, time had a direct and positive effect on osteoblast proliferation (P &lt; .001). The significant elements present in both brands of mini-implants were titanium, aluminum, vanadium, and iron. Conclusions:  Osteoblast proliferation was present on the mini-implants studied, which increased over time; however, no significant difference between brands was observed. No difference was seen between the mini-implants evaluated in terms of chemical composition. Cell adhesion after 72 hours suggests that areas of bone remodeling can be achieved, thus initiating the process of mini-implant anchorage.


2020 ◽  
Vol 11 (2) ◽  
pp. 160-166
Author(s):  
Mohammad Javad Moghaddas ◽  
Horieh Moosavi ◽  
Sara Yaghoubirad ◽  
Nasim Chiniforush

Introduction: The purpose of this study was to compare the effect of the bioactive glass, the glass ionomer, and the Erbium YAG laser as liners on the remineralization of the affected dentin. Methods: The present study was conducted on 64 healthy extracted human molars divided into 4 groups, 1 control group and 3 experimental groups. After artificially inducing dentinal caries lesions, each of the experimental groups was applied to the cavity floor and then restored with a composite. The samples were stored after thermocycling in an incubator for two months. Finally, the hardness of the cavity floor was measured at 3 depths of 20, 50 and 100 μm by the Vickers microhardness tester. The dentin conditions underneath the liners were also evaluated with FESEM. Statistical analysis was performed by two-way ANOVA and the post-hoc Games-Howell test (P<0.05). Results: Among the groups, the lowest microhardness value was in the control group (P<0.05) except at a depth of 100 μm; therefore, there was no significant difference between the control group and the bioactive glass (P>0.05). The laser group had the highest microhardness value, which was significantly different from the control group (P<0.05). There was a significant difference between the laser and bioactive glass (P<0.05), except at a depth of 20 μm. The laser and glass ionomer had only a significant difference at a depth of 100 μm (P<0.05). The microhardness value induced by glass ionomer was higher than bioactive glass, which in no depth was significant (P>0.05). Partial dentinal tubule occlusion was observed with FESEM in each of the experimental groups as compared to the control group. Conclusion: The microhardness values were higher in all groups than in the control group. The laser might be more successful in remineralization than the other ones.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Francesca Cattoni ◽  
Giulia Teté ◽  
Alessandro Mauro Calloni ◽  
Fabio Manazza ◽  
Giorgio Gastaldi ◽  
...  

Abstract Background Aesthetic porcelain veneers proved to be a long-term reliable prosthetic solution, ensuring minimal invasiveness. The use of veneers requires an adhesive cementation technique, so maintaining as much enamel as possible is to ensure lasting success. A diagnostic mock-up is a key tool that allows a preview of the outcome of the aesthetic restoration: it is obtainable both in an analog and digital way. With the recent developments in impression technology and the ever so fast growing use of CAD-CAM technologies it is useful to understand the pros and cons of either one of these techniques (analog and digital) in order to identify the easier and more convenient workflow in aesthetic dentistry. Methods After taking pictures and impressions of the dental arcs of a patient in need of aesthetic rehabilitation, 52 resin models were produced and a digital drawing of the smile was outlined. Both an analog and a digital wax-up were obtained from two of the 52 models: the latter was obtained using digital impressions and a dedicated software. The analog wax-up was then used to produce 25 matrices that have later been used to mould 25 resin mock-ups using a traditional moulding protocol (Control Group - CG). The digital wax-up was used to mill 25 PMMA mock-ups. Each mock-up, both milled and moulded (total 50), was then laid on the other 50 resin models as a digital impression of it was taken. The STL. files of the milled mock-ups were compared with the 3D CAD wax-up made using a specific software. The STL. files of the analog printed mock-ups were compared with the traditional wax-up design. A statistical analysis was carried out to evaluate the difference between the groups. Results The statistical analysis showed a significant difference (P > 0.01) between the mean value of the distance between the points of the overlapping STL. meshes in GC (0.0468 mm) and in TG (Test Group - TG) (0,0109 mm). Conclusions The study showed a difference in accuracy between traditional moulded and milled mock-ups compared to their original wax-up. The data analysis reports that the digital method allows for greater accuracy. Within the limitations of this study, a fully digital workflow is to considered more reliable when it come to creating an esthetic mockup: the digital procedure has been shown to be more accurate than the one made manually which is much more operator dependent and it brings an increase to the chance of error, and that could ultimately affect the final result.


2017 ◽  
Vol 11 (02) ◽  
pp. 221-225
Author(s):  
La-ongthong Vajrabhaya ◽  
Vanida Sangalungkarn ◽  
Ratchapin Srisatjaluk ◽  
Suwanna Korsuwannawong ◽  
Chareerut Phruksaniyom

ABSTRACT Objectives: This is an in vitro study to develop a formulation of a hypochlorite solution for root canal irrigation that lacks a chlorinated odor. The antibacterial effect, tissue dissolution efficacy, and the cytotoxicity of the solution were assessed in cell culture and were compared with those of commercial sodium hypochlorite (NaOCl) solutions. Materials and Methods: Trichloroisocyanuric acid (TCA) was used as the source of hypochlorite ions in solution. All required properties of the NaOCl irrigant were evaluated and compared with those of original 2.5% NaOCl solutions currently in use. Results: Our results revealed that a TCA 3.5% + 1/6 Buffer-1 solution passed the short-term stability test. Moreover, no odor of chlorine gas was detected by three independent observers. The hypochlorite ion content and pH were stable over an incubation period of 4 weeks. The new solution did not differ from commercial products in terms of the dissolution property on bovine pulpal tissue (P > 0.05). Moreover, the antibacterial effect of this solution on Enterococcus faecalis did not differ from that of the commercial products (P > 0.05). In addition, our biocompatibility analysis demonstrated no difference among the tested solutions (P > 0.05). Conclusions: According to the results of all properties tested, TCA 3.5% + 1/6 Buffer-1 could be considered an option for NaOCl irrigation with the benefit of no detectable chlorine odor.


Sign in / Sign up

Export Citation Format

Share Document