Reducing Tyre Hysteresis Losses using CuO Nanoparticles

Author(s):  
H.M. El-Zomor

<p class="5Abstracttext">Tyre is the contact part between the vehicle and road which provides various requirements of performance. Tyres are designed to absorb road irregularities, support vehicle load and provide braking/steering characteristics. An experimental test rig for single tyre test has been designed and constructed to evaluate the tyre performance characteristics under different operating conditions. The tyre load deflection characteristic has been examined by loading and unloading the tested tyre while resting on a hard surface at three inflation pressures. The results showed that the higher hysteresis losses were at tyre inflation pressure 20 psi. Three different percentages of CuO nanoparticles have been used to evaluate their effect on the tyre hysteresis losses. Transmission electron microscopy (TEM) has been performed for the analysis of nanoparticles size. Adding CuO nanoparticle in very small amounts with the enclosed air of the tested tyre can be useful for improving its performance significantly and decreasing the hysteresis losses. This has the potential for making use of the benefits of lower inflation pressure.</p>

Author(s):  
David A. Ansley

The coherence of the electron flux of a transmission electron microscope (TEM) limits the direct application of deconvolution techniques which have been used successfully on unmanned spacecraft programs. The theory assumes noncoherent illumination. Deconvolution of a TEM micrograph will, therefore, in general produce spurious detail rather than improved resolution.A primary goal of our research is to study the performance of several types of linear spatial filters as a function of specimen contrast, phase, and coherence. We have, therefore, developed a one-dimensional analysis and plotting program to simulate a wide 'range of operating conditions of the TEM, including adjustment of the:(1) Specimen amplitude, phase, and separation(2) Illumination wavelength, half-angle, and tilt(3) Objective lens focal length and aperture width(4) Spherical aberration, defocus, and chromatic aberration focus shift(5) Detector gamma, additive, and multiplicative noise constants(6) Type of spatial filter: linear cosine, linear sine, or deterministic


1993 ◽  
Vol 21 (1) ◽  
pp. 23-39 ◽  
Author(s):  
R. W. Scavuzzo ◽  
T. R. Richards ◽  
L. T. Charek

Abstract Tire vibration modes are known to play a key role in vehicle ride, for applications ranging from passenger cars to earthmover equipment. Inputs to the tire such as discrete impacts (harshness), rough road surfaces, tire nonuniformities, and tread patterns can potentially excite tire vibration modes. Many parameters affect the frequency of tire vibration modes: tire size, tire construction, inflation pressure, and operating conditions such as speed, load, and temperature. This paper discusses the influence of these parameters on tire vibration modes and describes how these tire modes influence vehicle ride quality. Results from both finite element modeling and modal testing are discussed.


Author(s):  
S H Mok ◽  
D G Gorman

Maintenance of offshore drilling mud pumps is normally based on running hours. It is generally accepted, however, that time does not provide an accurate means of scheduling maintenance, given the varying operating conditions of the reciprocating mud pumps. The energy expended at the interaction of sliding surfaces is hypothesized to be a better alternative. The effects of operating variables on wear rates are investigated. A Taguchi experimental design was used to identify those factors that significantly affect wear. Within the confines of an experimental test rig, the normal load and abrasive sand content was found to have a significant effect on the specific wear rate of nitrile rubber sliding on steel in drilling fluid.


Author(s):  
B. R. Nichols ◽  
R. L. Fittro ◽  
C. P. Goyne

Many high-speed, rotating machines across a wide range of industrial applications depend on fluid film bearings to provide both static support of the rotor and to introduce stabilizing damping forces into the system through a developed hydrodynamic film wedge. Reduced oil supply flow rate to the bearings can cause cavitation, or a lack of a fully developed film layer, at the leading edge of the bearing pads. Reducing oil flow has the well-documented effects of higher bearing operating temperatures and decreased power losses due to shear forces. While machine efficiency may be improved with reduced lubricant flow, little experimental data on its effects on system stability and performance can be found in the literature. This study looks at overall system performance of a test rig operating under reduced oil supply flow rates by observing steady-state bearing performance indicators and baseline vibrational response of the shaft. The test rig used in this study was designed to be dynamically similar to a high-speed industrial compressor. It consists of a 1.55 m long, flexible rotor supported by two tilting pad bearings with a nominal diameter of 70 mm and a span of 1.2 m. The first bending mode is located at approximately 5,000 rpm. The tiling-pad bearings consist of five pads in a vintage, flooded bearing housing with a length to diameter ratio of 0.75, preload of 0.3, and a load-between-pad configuration. Tests were conducted over a number of operating speeds, ranging from 8,000 to 12,000 rpm, and bearing loads, while systematically reducing the oil supply flow rates provided to the bearings under each condition. For nearly all operating conditions, a low amplitude, broadband subsynchronous vibration pattern was observed in the frequency domain from approximately 0–75 Hz. When the test rig was operated at running speeds above its first bending mode, a distinctive subsynchronous peak emerged from the broadband pattern at approximately half of the running speed and at the first bending mode of the shaft. This vibration signature is often considered a classic sign of rotordynamic instability attributed to oil whip and shaft whirl phenomena. For low and moderate load conditions, the amplitude of this 0.5x subsynchronous peak increased with decreasing oil supply flow rate at all operating speeds. Under the high load condition, the subsynchronous peak was largely attenuated. A discussion on the possible sources of this subsynchronous vibration including self-excited instability and pad flutter forced vibration is provided with supporting evidence from thermoelastohydrodynamic (TEHD) bearing modeling results. Implications of reduced oil supply flow rate on system stability and operational limits are also discussed.


1966 ◽  
Vol 181 (1) ◽  
pp. 53-73 ◽  
Author(s):  
I. K. Csillag

The demand for electric power has doubled in the last decade. The most economical way to meet this demand is by building large-output generating units. The study of the major factors which determine the output of such generators shows that the only effective way to increase the output is by improving the cooling of their windings. For that reason design has progressed from air-cooling to indirect hydrogen-cooling, then to direct hydrogen-cooling. Now the trend is towards direct water-cooling where the water is in direct contact with the copper windings. The introduction of water into the stator winding was established in 1956 (1)† and was in fact directly responsible for the present increase in unit rating. The introduction of water to a rotating winding presents difficult problems in both design and manufacture. The test rig dealt with in this paper was built to study some of these problems and to carry out experimental investigations on a full size model of the special hydraulic features for a water-cooled turbo-generator rotor. The investigations were concentrated around the following five different problems which are dealt with in detail: (1) increase in pressure drop due to rotation; (2) free-rotating seal (inlet seal) (2); (3) vacuum-breaking device (water outlet) (3); (4) loss-distribution in the rotor; (5) measurement of the rotor vibrations in various operating conditions.


Author(s):  
Davide Laera ◽  
Giovanni Campa ◽  
Sergio M. Camporeale ◽  
Edoardo Bertolotto ◽  
Sergio Rizzo ◽  
...  

This paper concerns the acoustic analysis of self–sustained thermoacoustic pressure oscillations that occur in a test rig equipped with full scale lean premixed burner. The experimental work is conducted by Ansaldo Energia and CCA (Centro Combustione Ambiente) at the Ansaldo Caldaie facility in Gioia del Colle (Italy), in cooperation with Politecnico di Bari. The test rig is characterized by a longitudinal development with two acoustic volumes, plenum and combustion chamber, coupled by the burner. The length of both chambers can be varied with continuity in order to obtain instability at different frequencies. A previously developed three dimensional finite element code has been applied to carry out the linear stability analysis of the system, modelling the thermoacoustic combustion instabilities through the Helmholtz equation under the hypothesis of low Mach approximation. The heat release fluctuations are modelled according to the κ-τ approach. The burner, characterized by two conduits for primary and secondary air, is simulated by means of both a FEM analysis and a Burner Transfer Matrix (BTM) method in order to examine the influence of details of its actual geometry. Different operating conditions, in which self–sustained pressure oscillations have been observed, are examined. Frequencies and growth rates of unstable modes are identified, with good agreement with experimental data in terms of frequencies and acoustics pressure wave profiles.


2011 ◽  
Vol 47 (1) ◽  
pp. 73-78 ◽  
Author(s):  
E. Darezereshki ◽  
F. Bakhtiari

In this study CuO nanoparticles were prepared via direct thermal decomposition method using basic copper sulphates as wet chemically synthesized precursor which was calcined in air at 750?C for 2h. Samples were characterized by thermogravimetric (TG-DSC), X-ray diffraction (XRD), energy dispersive spectroscopy (EDS), infrared spectrum (IR), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The XRD, EDS, and IR results indicated that the synthesized CuO particles were pure. The SEM and TEM results showed that the CuO nanoparticles were of approximate spherical shape, and 170?5 nm in size. Using this method, Cuo nanoparticles could be produced without using organic solvent, expensive raw materials, and complicated equipment.


2009 ◽  
Author(s):  
Jan H. Andersen ◽  
Hiroyuki Sada ◽  
Seiji Yamajo

This paper presents the results of an investigation into the theoretical and experimental performance of oil lubricated journal bearings. DNV has developed a new calculation tool for the analysis of journal bearing performance as part of shaft alignment analysis. The results of the calculation tool have been compared to other research and analysis methods under static and dynamic conditions. In addition, white metal bearings were tested with decreasing Sommerfeld number until loss of hydrodynamic lubrication. The experiments were carried out in a bearing test rig and with three different lubricants, normal mineral oil, emulsifying oil, and water-soluble oil. The tests were done with increasing water content in the lubricant. Results from the test were compared with calculation using the DNV analysis tool.


Author(s):  
Sayed Reza Shaffiey ◽  
Sayedeh Fatemeh Shaffiey

Aeromonas hydrophila is a heterotrophic, gram negative bacterium which is primary or secondary cause of ulcers, fin rot, tail rot, and hemorrhagic septicaemia in fish. The treatments for this infection are only restricted to some antibiotics. So, novel materials are being searched for combating with bacterial infections and the resulting consequences. In this chapter, Ag2O/CuO nanocomposites were synthesized chemically and characterized by X-ray diffraction (XRD), scanning electron micrograph (SEM) and transmission electron microscope (TEM). The antimicrobial activities of Ag2O/CuO nanoparticles (NPs), was checked by both well diffusion and turbidometric (spectrophotometric) method. Synthesized nanoparticles exhibited their antimicrobial efficacy in both the standard inhibitory assays; these results thus provide a scope for further research on the application of Ag2O/CuO nanoparticles as disinfectant and/or antibiotic in the fishery industry.


2002 ◽  
Vol 716 ◽  
Author(s):  
Larry Rice

AbstractMicroscopists are faced with many challenges in locating and examining failure sites in the ever-shrinking semiconductor device. The site must be located using electrical characterization techniques like electron beam induced current (EBIC), photo emission microscopy (PEM) or liquid crystal (LC) and then cross-sectioned with a focused ion beam (FIB). Both PEM and LC require the semiconductor circuit to be running near operating conditions which has been observed to locally melt the area of interest, frequently destroying evidence of the failure mechanism. In contrast, EBIC typically can be accomplished at low or no applied voltage eliminating further damage to the circuit. EBIC has been applied to locate leakage sites in high voltage metal oxide semiconductor (MOS) electro static discharge (ESD) reliability failures. In addition to a brief revisit of the basic principles of EBIC and describing a technique to successfully cross section ‘hot spots’ for transmission electron microscopy (TEM) observation, focus will be placed on a case study of the reliability testing failure analysis of ESD power transistors using EBIC, SEM, focused ion beam (FIB), and XTEM.


Sign in / Sign up

Export Citation Format

Share Document