scholarly journals Efektivitas pengolahan limbah cair hotel dan implementasi keputusan Menteri Lingkungan Hidup nomor 52/menlh/10/1995 tentang baku mutu limbah cair bagi kegiatan hotel di Kota Pekanbaru

Jurnal Zona ◽  
2017 ◽  
Vol 1 (1) ◽  
pp. 1-8
Author(s):  
Syafri Boy ◽  
Aras Mulyadi ◽  
Sukendi Sukendi

This research aims to determine the effectiveness of the treatment of waste water hotel and see Implemantation Decree of the Minister of Environment No.52/MENLH/10/1995 concerning the Waste water Quality Hotel by five-star hotel in the city of Pekanbaru. The method used in this research is the survey and interview. Based on the analysis we found that the rate of decrease in the content of pollutants in the waste water hotel in reducing the content of pollutants in the waste water for parameters BOD, COD, TSS and pH respectively 72%, 75%, 25% and 16%. IPL Cability levels in the lower levels of waste water sample parameters for the parameters BOD, COD, TSS and pH respectively 60.0%, 30.0%, 50.0% and 87.5%. IPLC analysis results in Pekanbaru compared with the Waste water Quality Standard Hotel, pollutant levels are still above the environmental quality standards.

2020 ◽  
Vol 6 (1) ◽  
pp. 96
Author(s):  
FX Anjar Tri Laksono ◽  
Indra Permanajati ◽  
Rahmat Mualim

In Mohoni Village, East Petasia District, North Morowali Regency there are nickel mining activities that are carried out by PT. Asiamax Mining Indonesia. Several locations were mine out status. Hence, reclamation programs are made to improve environmental conditions before mining. One of these stages is water quality tests to ensure that the reclamation area is worthy to be a habitat for animals and plants. The purpose of this study is to find out the water quality in the reclamation area of the ex-nickel mining in Mohoni Village. The storet method is used to analyze water quality whose test parameters include pH, total suspanded solid (TSS), concentrations of copper (Cu), cadmium (Cd), zinc (Zn), lead (Pb), nickel (Ni), chromium valence 6, iron (Fe), manganese (Mn), and cobalt (Co) once every three months for a year.The quality water check results are compared with the environmental quality standards in accordance with law number 32 of 2009. Based on the average monitoring results show that the water quality is classified as moderately polluted. The conclusion from this study is that reclamation land might be not used as habitat for animals and plants because the availability of water is not suitable for consumption


2016 ◽  
Vol 16 (1) ◽  
pp. 19
Author(s):  
Gorby Corneles Tarima ◽  
Jemmy Abidjulu ◽  
Harry S.J. Koleangan

ANALISIS KUALITAS AIR SUNGAI SARIO KECAMATAN SARIO MANADO  SULAWESI UTARAABSTRAK Penelitian ini dilakukan untuk menganalisis kualitas air sungai Sario berdasarkan sifat fisika dan kimia sesuai dengan PP No 82 Tahun 2001. Penelitian dilakukan di laboratorium Baristand Industri Manado pada bulan November 2015, dengan 4 sampel air yang diambil pada 4 titik dari hulu sampai hilir sungai Sario Kota Manado menggunakan 7 parameter yaitu kekeruhan, pH, nitat, nitrit, BOD, COD dan DO. Hasil penelitian ini menunjukkan bahwa kualitas air sungai Sario yang sesuai dengan ambang baku mutu air berdasarkan PP No. 82 Tahun 2001 hanyalah pada bagian hulu sampai tengah Sungai sebelum memasuki wilayah Kota Manado, sedangkan pada sekitaran hilir sungai Sario telah tercemar yang berhubungan dengan aktivitas masyarakat dengan diindikasikan berdasarkan konsentrasi BOD, COD dan DO yang buruk dan tidak sesuai dengan ambang baku mutu air berdasarkan PP No. 82/2001. Kata kunci : Kualitas Air, Sungai Sario   ANALYSIS OF RIVER WATER QUALITY SARIO DISTRICT MANADO  NORTH SULAWESI ABSTRACT This study was conducted to analyze the Sario river water quality based on physical and chemical properties in accordance with PP No. 82 of 2001. The study was conducted in laboratory Baristand Industry Manado in November 2015, with four water samples taken at 4 points from upstream to downstream Sario City Manado using 7 parameters: turbidity, pH, nitat, nitrite, BOD, COD and DO.  The results of this study indicate that the water quality in accordance with the Sario river water quality standard threshold under PP No. 82 of 2001 only on the upstream side to the middle of the river before entering the city of Manado, whereas the downstream Area Sario river has been polluted related community activities to be indicated by the concentration of BOD, COD and DO poor and not in accordance with the water quality standard threshold based PP No. 82 of 2001. Keywords: Water Quality, River Sario


Author(s):  
Desy Rosarina ◽  
Ellysa Kusuma Laksanawati ◽  
Dewi Rosanti

This paper explained heavy metals and chemical properties from the Cisadane River in Tangerang City. A survey method was used to determine the place for sampling the test material. Water measurement is carried out in situ and laboratory tests. Data retrieval was done by purposive sampling determining three observation stations, namely in the Taman Gajah Tunggal park area (station1), Babakan Cikokol residential area (station 2), and Karawaci paper mill area (station 3). The analysis was carried out exactly using analysis. Namely, analysis carried out in the laboratory. The parameters observed were COD, phosphate, DO, BOD, pH. Results of this study informed the water quality in the Cisadane City river did not meet Class II Water Quality Standards based on Government Regulation Number 82, the year 2001. The COD content only meets class II water quality standards at stations 1 and 3. BOD and phosphate content is high and exceeds class II water quality standards. Heavy metal content still meets the water quality standard threshold with a value of Cd less than 0.01 mg/L, Cu less than 0.02 mg/L, Pb less than 0.03mg/L, and Cr less than 0.05mg/L. Zn content exceeds the water quality standard threshold at station three and meets water quality standards at stations 1 and 2 with a value of less than 0.05mg/L.


2004 ◽  
Vol 8 (4) ◽  
pp. 636-650 ◽  
Author(s):  
D. L. Snook ◽  
P. G. Whitehead

Abstract. A regional overview of the water quality and ecology of the River Lee catchment is presented. Specifically, data describing the chemical, microbiological and macrobiological water quality and fisheries communities have been analysed, based on a division into river, sewage treatment works, fish-farm, lake and industrial samples. Nutrient enrichment and the highest concentrations of metals and micro-organics were found in the urbanised, lower reaches of the Lee and in the Lee Navigation. Average annual concentrations of metals were generally within environmental quality standards although, on many occasions, concentrations of cadmium, copper, lead, mercury and zinc were in excess of the standards. Various organic substances (used as herbicides, fungicides, insecticides, chlorination by-products and industrial solvents) were widely detected in the Lee system. Concentrations of ten micro-organic substances were observed in excess of their environmental quality standards, though not in terms of annual averages. Sewage treatment works were the principal point source input of nutrients, metals and micro-organic determinands to the catchment. Diffuse nitrogen sources contributed approximately 60% and 27% of the in-stream load in the upper and lower Lee respectively, whereas approximately 60% and 20% of the in-stream phosphorus load was derived from diffuse sources in the upper and lower Lee. For metals, the most significant source was the urban runoff from North London. In reaches less affected by effluent discharges, diffuse runoff from urban and agricultural areas dominated trends. High microbiological content, observed in the River Lee particularly in urbanised reaches, was far in excess of the EC Bathing Water Directive standards. Water quality issues and degraded habitat in the lower reaches of the Lee has led to impoverished aquatic fauna but, within the mid-catchment reaches and upper agricultural tributaries, less nutrient enrichment and channel alteration has permitted more diverse aquatic fauna. Keywords: River Lee, River Thames, water quality, nutrients, metals, ecology, hydrology, diffuse and point source pollution


2012 ◽  
Vol 65 (7) ◽  
pp. 1290-1297 ◽  
Author(s):  
Oliver Gabriel ◽  
Katerina Ruzicka ◽  
Norbert Kreuzinger

The new water quality protection approach of the EU combines the control of emissions with instream Environmental Quality Standards (=EQS). Since 1 April 2006 and actually relevant in the version of 2010 in Austria, priority substances from list A of the EUROPEAN DIERECTIVE 76/464 and further EQS of relevant chemical substances (list B), identified by a national risk assessment, have to be reached to achieve a good ecological state in the surface water (Edict for Water Quality Standards, 2006; changes to the Edict for Water Quality Standards 2010). The practical assessment of these substances after point source emissions is prescribed in the Edict, but rarely carried out. In this paper, two substances, namely: (1) ammonium (list B); and (2) nonylphenol, an endocrine disrupting compound (list A) are presented to discuss: (i) the improvement of treatment efficiency due to the upgrade of a large Waste Water Treatment Plant (=WWTP); (ii) the relevance of mixing processes and modelling as a method to control EQS after point source emissions; and (iii) the improvement of water quality in the ambient surface waters. It is shown that the improved treatment in the case of nonylphenol leads to emission values which fall below the EQS, making an assessment unnecessary. In the case of ammonium emission, values are significantly reduced and violation of EQS is avoided, while mixing modelling is shown to be a suitable instrument to address the resulting instream concentrations at different border conditions.


2011 ◽  
Vol 250-253 ◽  
pp. 3941-3944
Author(s):  
Xiao Qiang Chen ◽  
He Li Wang ◽  
Xiao Jing Zhu

As the lake water of Yuyuantan Park of Beijing has became micro-polluted water after the cycles of social landscape and the micro-polluted water run into the Kunyu River, the research adopts a method of manual simulation to treatment the micro-polluted water with a new-type of compound pattern we call landscape-designed ecological barrier which consists of ecological pond and constructed wetland . In order to weak the adverse effects of micro-polluted water on natural water, this new-type of compound pattern forms a landscape-designed ecological barrier. After 5 months experiment, results show that the landscape-designed ecological barrier has a better removal of pollutants. The removal rates of COD, TN and TP respectively reached 65.2% ~ 73.6%, 62.5% ~ 66.0% and 70.0% ~ 80.0%. And the effluent quality can reach III - IV water-quality of environmental quality standards for surface water(GB3838-2002). In Autumn, the concentration of CODCr, TN and TP in effluent sustain at IV water-quality of environmental quality standards for surface water(GB3838-2002), and at the same time create artificial landscape water with environmental aesthetic and ornamental value, bring the benefit of water resources as well as positive ecological environment effects into full play synthetically.


2013 ◽  
Vol 838-841 ◽  
pp. 1698-1702
Author(s):  
Zhi Gang Chen ◽  
Jun Jing Chen ◽  
Han Xiang Chen ◽  
Qing Jie Xie

The water quality of the Jinshan Lake in Zhen Jiang city were evaluated mainly on the basis of forty samples collected from four locations.The purposes of the study were to assess the levels of parameters associated with the demands of the functions of the water body and to compare them with Environmental Quality Standards for Surface Water. Water quality parameters included pH, Temperature, Biological Oxygen Demand (BOD5), Chemical Oxygen Demand (CODMn), permanganate index, Total Nitrogen (TN), Total Phosphorus (TP), and NH3-N were analyzed. These water quality parameters were surveyed in 2012 on a monthly basis.Most of them met the Class Ⅲ level of Environmental Quality Standards for Surface Water excepting the Total Nitrogen and Total Phosphorus.The results show that the phenomenon of eutrophication existed in the the Jinshan Lake in 2012.


2017 ◽  
Vol 14 (1) ◽  
pp. 46
Author(s):  
Meirani Agustina ◽  
Sri Cahyo Wahyono ◽  
Tetti Novalina Manik

The landfills (TPA) Cahaya Kencana is applying system Sanitary Landfill, the landfill system that is done by the garbage dumped and compacted, then covered with dirt as cover and carried out continuously each end of the operation. This research is very important investigate the distribution of leachate contaminated leachate approximately systems Sanitary Landfill based on the resistivity value and the content of chemical elements in the holding pond. Based on the results of data processing 2D geoelectric Wenner configuration on four tracks with each track length of 100 m were processed using Res2dinv, obtainable at a depth of between 0.75 – 11.6 m resistivity values in the leachate is 4.34 – 10.0 Ωm track 2, 3, and 4, but are not on track 1. The results of laboratory test on four samples consecutive for content. BOD leachate from 26.2 - 121.0 mg/l; and COD 132.5 – 276.2 mg/l is not exceeded the limit of waste water quality standard, except for sample 4 with a COD value of 472.9 mg/l while for pH 7.24 - 7.39 mg/l and the concentration of heavy metals in leachate outlet still on the threshold of normal, where Pb <0.0019 mg/l; Cd <0.0019 mg/l; and Cr <0,0035mg/l.


2021 ◽  
Vol 934 (1) ◽  
pp. 012065
Author(s):  
Y Harjoyudanto ◽  
N Asiah

Abstract Kampar River, Siak River, and Rokan River have different watersheds, and the water from these rivers is not interconnected. The results of this study can be used as a basis for managing aquatic resources in the Kampar River, Siak River, and Rokan River, Riau Province, Indonesia. This research was conducted in April 2017 – March 2018. The collection and measurement of water quality for each river consisted of three stations which were carried out based on SNI through the survey method twice, namely in the dry season and rainy season. The observed water quality parameters include physical, chemical, and biological parameters. The results of the next analysis are calculated using the STORET method using a value system from the United State-Environmental Protection Agency (US-EPA) which is adjusted to the Class III Water Quality Standard based on PP. 22 of 2021. The results of the analysis of the rain index value in the highest dry season is a score of -44 on the Rokan River, classified as class D with a score of -31 heavily polluted. The STORET score in the Kampar River and Siak River obtained -24, each classified as Class C, is included in the moderately polluted category. Meanwhile, in the rainy season the pollution index with the same pattern is highest in the Rokan River -40, then Kampar River, and Siak River each -20. The water quality standard used in this study is class III because it still supports fish farming activities. Based on Government Regulation Number 22 of 2021 concerning water quality standards, class III is water whose designation can be used for freshwater fish aquaculture, animal husbandry, and gardens irrigation. The Storet method is carried out by collecting water quality data and measuring data from each water parameter compared to the value of class III water quality standards.


2019 ◽  
Vol 2 (1) ◽  
pp. 29
Author(s):  
Kurniawasyah Kurniawasyah ◽  
Guntar M Saragih

The development of factories influences the quality of the environment, especially palm oil mills, in managing the need for checks on quality standards of environmental quality such as water quality, air quality and noise and quality of wastewater, which play an important role in the sustainable use of natural resources. submission of reports or compliance commitments from palm oil factories in conveying the quality standards of waste produced, from 20 palm oil mills operating in Muaro Jambi on average 90% have submitted periodic reports each semester in the management of environmental quality in terms of water quality, air and noise, and the quality of waste water has met the quality standard requirements in accordance with the Law of the Republic of Indonesia Number 32 of 2009 concerning Protection and Management of the Environment, using univariate analysis methods and application of calculations from SPSS obtained level k compliance from palm oil mills operating in compliance with the requirements in accordance with the quality standards and regulations that apply then in terms of PROPER assessment the average palm oil mill operating in Muaro Jambi Regency received a Gold rating in environmental management.