scholarly journals A Study on the Electromagnetic Shield Structure of High Frequency RF Module for Aircraft

2021 ◽  
Vol 22 (7) ◽  
pp. 572-578
Author(s):  
Sang Hoon Park ◽  
Seung Han Kim
2010 ◽  
Vol 2010 ◽  
pp. 1-5
Author(s):  
Yusuke Kondo ◽  
Yasushi Shimada ◽  
Yoshitaka Hirata ◽  
Kazunori Yamamoto ◽  
Etsuo Watanabe ◽  
...  

Radio Frequency (RF) modules have been miniaturized to meet the demand for smaller and more enhanced handsets for wireless applications such as cellular phones. However, area for passive devices used in RF modules has made further miniaturization difficult. Passives embedded in substrates are now being studied intensively. In addition, circuit simulation technology has been developed that enables efficient designing of RF module circuits. Circuit designers, however, have limited database of organic substrates and embedded passives. Further, optimized thermal designs are required to prevent thermal resistance increase due to miniaturization of substrates. In this paper, we describe the high-frequency properties of the capacitors embedded in the organic substrates and present the equivalent circuit models of the embedded capacitors. We also present the thermal design of organic substrates applicable to RF modules.


2014 ◽  
Vol 2 (3) ◽  
pp. 44 ◽  
Author(s):  
A. Désiré ◽  
A. Kriga ◽  
M. Youssouf ◽  
A. Siblini ◽  
C. M. Jean-Pierre ◽  
...  

This paper presents two fabrication techniques of spiral integrated inductors based on magnetic materials. For the first one, the magnetic core is a thin film deposited by RF magnetron sputtering, for the second technique the magnetic core is a thick layer of YIG obtained by micromachining. The addition of the magnetic material is expected to improve the performances of the integrated structure with electromagnetic shield. Low and high frequency equipment are used to characterize the manufactured components. A good correlation is obtained between the results by simulation and measurements for the two manufacturing techniques. These results show that the inductance increases when the thickness of the magnetic layer increases, we can double the inductance value for a thickness sufficiently high.


2003 ◽  
Vol 783 ◽  
Author(s):  
James J. Logothetis ◽  
Daniel I. Amey ◽  
Timothy P. Mobley

ABSTRACTThis presentation describes the basics of Multi-Mix® and Green Tape™ Low Temperature Cofired Ceramic (LTCC) technologies. The design and performance of a 28 GHz mixer package using a GaAs MMIC and the 943 Green Tape™ LTCC system with embedded capacitance technology is described including the tradeoffs, advantages and compatibility of Multi-Mix® and Green Tape™ technologies. A design approach combining the technologies offers the designer new options to meet the ever-increasing demands of high frequency packaging.


Author(s):  
W. E. Lee ◽  
A. H. Heuer

IntroductionTraditional steatite ceramics, made by firing (vitrifying) hydrous magnesium silicate, have long been used as insulators for high frequency applications due to their excellent mechanical and electrical properties. Early x-ray and optical analysis of steatites showed that they were composed largely of protoenstatite (MgSiO3) in a glassy matrix. Recent studies of enstatite-containing glass ceramics have revived interest in the polymorphism of enstatite. Three polymorphs exist, two with orthorhombic and one with monoclinic symmetry (ortho, proto and clino enstatite, respectively). Steatite ceramics are of particular interest a they contain the normally unstable high-temperature polymorph, protoenstatite.Experimental3mm diameter discs cut from steatite rods (∼10” long and 0.5” dia.) were ground, polished, dimpled, and ion-thinned to electron transparency using 6KV Argon ions at a beam current of 1 x 10-3 A and a 12° angle of incidence. The discs were coated with carbon prior to TEM examination to minimize charging effects.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


2019 ◽  
Vol 28 (1S) ◽  
pp. 209-224 ◽  
Author(s):  
Julia Campbell ◽  
Alison LaBrec ◽  
Connor Bean ◽  
Mashhood Nielsen ◽  
Won So

2020 ◽  
Vol 29 (3) ◽  
pp. 429-435
Author(s):  
Patricia C. Mancini ◽  
Richard S. Tyler ◽  
Hyung Jin Jun ◽  
Tang-Chuan Wang ◽  
Helena Ji ◽  
...  

Purpose The minimum masking level (MML) is the minimum intensity of a stimulus required to just totally mask the tinnitus. Treatments aimed at reducing the tinnitus itself should attempt to measure the magnitude of the tinnitus. The objective of this study was to evaluate the reliability of the MML. Method Sample consisted of 59 tinnitus patients who reported stable tinnitus. We obtained MML measures on two visits, separated by about 2–3 weeks. We used two noise types: speech-shaped noise and high-frequency emphasis noise. We also investigated the relationship between the MML and tinnitus loudness estimates and the Tinnitus Handicap Questionnaire (THQ). Results There were differences across the different noise types. The within-session standard deviation averaged across subjects varied between 1.3 and 1.8 dB. Across the two sessions, the Pearson correlation coefficients, range was r = .84. There was a weak relationship between the dB SL MML and loudness, and between the MML and the THQ. A moderate correlation ( r = .44) was found between the THQ and loudness estimates. Conclusions We conclude that the dB SL MML can be a reliable estimate of tinnitus magnitude, with expected standard deviations in trained subjects of about 1.5 dB. It appears that the dB SL MML and loudness estimates are not closely related.


Sign in / Sign up

Export Citation Format

Share Document