cell monitoring
Recently Published Documents


TOTAL DOCUMENTS

216
(FIVE YEARS 65)

H-INDEX

29
(FIVE YEARS 3)

2021 ◽  
Author(s):  
Yeongseok Jang ◽  
Seungbeom Han ◽  
Chulgyu Song ◽  
Jinmu Jung ◽  
Jonghyun Oh

Abstract In the field of biology, dark field microscopy provides superior insight into cells and subcellular structures. However, most dark field microscopes are equipped with a dark field filter and a light source on a 2D-based specimen, so only a flat sample can be observed in a limited space. We propose a compact cell monitoring system with built-in dark field filter with an optimized incident angle of the light source to provide real-time cell imaging and spatial cell monitoring. 2D/3D projected darkfield images are optimized for 2D/3D samples as they rely on darkfield filters, and incident light. 2D projection imaging was implemented using a modular condenser lens to acquire high-contrast images. This enabled the long-term monitoring of cells, and the real-time monitoring of cell division and death. This system was able to image, by 2D projection, cells on the surface thinly coated with multi-walled carbon nanotubes, as well as living cells that migrated along the surface of glass beads and hydrogel droplets with a diameter of about 160 μm. The Optimal incident light angle-fitted dark field system combines high-contrast imaging sensitivity and high spatial resolution to even image cells on three-dimensional surfaces.


ACS Omega ◽  
2021 ◽  
Author(s):  
Denise Lee ◽  
Sophia S. Y. Chan ◽  
Nemanja Aksic ◽  
Natasa Bajalovic ◽  
Desmond K. Loke

2021 ◽  
Vol 8 (12) ◽  
pp. 204
Author(s):  
Nor Azila Abd. Wahid ◽  
Azadeh Hashemi ◽  
John J. Evans ◽  
Maan M. Alkaisi

Culture platform surface topography plays an important role in the regulation of biological cell behaviour. Understanding the mechanisms behind the roles of surface topography in cell response are central to many developments in a Lab on a Chip, medical implants and biosensors. In this work, we report on a novel development of a biocompatible conductive hydrogel (CH) made of poly (3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) and gelatin with bioimprinted surface features. The bioimprinted CH offers high conductivity, biocompatibility and high replication fidelity suitable for cell culture applications. The bioimprinted conductive hydrogel is developed to investigate biological cells’ response to their morphological footprint and study their growth, adhesion, cell–cell interactions and proliferation as a function of conductivity. Moreover, optimization of the conductive hydrogel mixture plays an important role in achieving high imprinting resolution and conductivity. The reason behind choosing a conducive hydrogel with high resolution surface bioimprints is to improve cell monitoring while mimicking cells’ natural physical environment. Bioimprints which are a 3D replication of cellular morphology have previously been shown to promote cell attachment, proliferation, differentiation and even cell response to drugs. The conductive substrate, on the other hand, enables cell impedance to be measured and monitored, which is indicative of cell viability and spread. Two dimensional profiles of the cross section of a single cell taken via Atomic Force Microscopy (AFM) from the fixed cell on glass, and its replicas on polydimethylsiloxane (PDMS) and conductive hydrogel (CH) show unprecedented replication of cellular features with an average replication fidelity of more than 90%. Furthermore, crosslinking CH films demonstrated a significant increase in electrical conductivity from 10−6 S/cm to 1 S/cm. Conductive bioimprints can provide a suitable platform for biosensing applications and potentially for monitoring implant-tissue reactions in medical devices.


Author(s):  
David Baker ◽  
Amy MacDougall ◽  
Angray S Kang ◽  
Klaus Schmierer ◽  
Gavin Giovannoni ◽  
...  

Abstract Although there is an ever-increasing number of disease-modifying treatments for relapsing multiple sclerosis (MS), few appear to influence COVID-19 severity. There is concern about the use of anti-CD20-depleting monoclonal antibodies, due to the apparent increased risk of severe disease following SARS-CoV-2 infection and inhibition of protective anti-COVID-19 vaccine responses. These antibodies are given as maintenance infusions/injections and cause persistent depletion of CD20+ B cells, notably memory B cell populations that may be instrumental in the control of relapsing MS. However, they also continuously deplete immature and mature/naïve B cells that form the precursors for infection-protective antibody responses, thus blunting vaccine responses. Seroconversion and maintained SARS-CoV-2 neutralizing antibody levels provide protection from COVID-19. However, it is evident that poor-seroconversion occurs in the majority of individuals following initial and booster COVID-19 vaccinations, based on standard 6-monthly dosing intervals. Seroconversion may be optimized in the anti-CD20-treated population by vaccinating prior to treatment-onset or using extended/delayed interval dosing (3-6 month extension to dosing interval) in those established on therapy, with B cell monitoring until (1-3%) B cell repopulation occurs prior to vaccination. Some people will take more than a year to replete and therefore protection may depend on either the vaccine-induced T cell responses that typically occur or may require prophylactic, or rapid post-infection therapeutic, antibody or small molecule anti-viral treatment to optimise protection against COVID-19. Further studies are warranted to demonstrate the safety and efficacy of such approaches and whether or not immunity wanes prematurely as has been observed in the other populations.


2021 ◽  
Vol 2071 (1) ◽  
pp. 012052
Author(s):  
N A Zulkiflli ◽  
M D Shahrulnizahani ◽  
X F Hor ◽  
F A Phang ◽  
M F Rahmat ◽  
...  

Abstract Cell sensing and monitoring using capacitive sensors are widely used in cell monitoring because of the flexible and uncomplicated design and fabrication. Previous work from many different fields of applications has integrated capacitive sensing technique with tomography to produce cross-sectional images of the internal dielectric distribution. This paper carried an investigation on the capabilities of four 16-channel sensor electrodes with different electrode sizes to detect the change in the dielectric distribution of the cultured cells. All three 16-channel sensor electrodes are designed and simulate on COMSOL 6.3a Multiphysics. The pre-processing results obtained from three finite element models (FEM) of ECT sensor configurations in detecting the cell phantom shows that bigger electrodes size are more sensitive to permittivity distribution.


ACS Sensors ◽  
2021 ◽  
Author(s):  
Han Zhao ◽  
Donghan Ma ◽  
Junkai Xie ◽  
Oscar Sanchez ◽  
Fang Huang ◽  
...  

2021 ◽  
Vol 111 ◽  
pp. 106969
Author(s):  
Sonja Stoelzle-Feix ◽  
Krisztina Juhasz ◽  
Michael Skiba ◽  
Joachim Wegener ◽  
Ronald Knox ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document