scholarly journals In vitro response of THP-1 derived macrophages to antimicrobially effective PHMB-coated Ti6Al4V alloy implant material with and without contamination with S. epidermidis and P. aeruginosa

2022 ◽  
Vol 26 (1) ◽  
Author(s):  
Paula Zwicker ◽  
Thomas Schmidt ◽  
Melanie Hornschuh ◽  
Holger Lode ◽  
Axel Kramer ◽  
...  

Abstract Aim Periprosthetic joint infections are a devastating complication after arthroplasty, leading to rejection of the prosthesis. The prevention of septic loosening may be possible by an antimicrobial coating of the implant surface. Poly (hexamethylene) biguanide hydrochloride [PHMB] seems to be a suitable antiseptic agent for this purpose since previous studies revealed a low cytotoxicity and a long-lasting microbicidal effect of Ti6Al4V alloy coated with PHMB. To preclude an excessive activation of the immune system, possible inflammatory effects on macrophages upon contact with PHMB-coated surfaces alone and after killing of S. epidermidis and P. aeruginosa are analyzed. Methods THP-1 monocytes were differentiated to M0 macrophages by phorbol 12-myristate 13-acetate and seeded onto Ti6Al4V surfaces coated with various amounts of PHMB. Next to microscopic immunofluorescence analysis of labeled macrophages after adhesion on the coated surface, measurement of intracellular reactive oxygen species and analysis of cytokine secretion at different time points without and with previous bacterial contamination were conducted. Results No influence on morphology of macrophages and only slight increases in iROS generation were detected. The cytokine secretion pattern depends on the surface treatment procedure and the amount of adsorbed PHMB. The PHMB coating resulted in a high reduction of viable bacteria, resulting in no significant differences in cytokine secretion as reaction to coated surfaces with and without bacterial burden. Conclusion Ti6Al4V specimens after alkaline treatment followed by coating with 5–7 μg PHMB and specimens treated with H2O2 before PHMB-coating (4 μg) had the smallest influence on the macrophage phienotype and thus are considered as the surface with the best cytocompatibility to macrophages tested in the present study.

2021 ◽  
Vol 6 (6) ◽  
pp. 189-198
Author(s):  
Ahmed Siddiqi ◽  
Zuhdi E. Abdo ◽  
Bryan D. Springer ◽  
Antonia F. Chen

Abstract. Irrigation and debridement in the treatment of periprosthetic joint infection (PJI) serve an integral role in the eradication of bacterial burden and subsequent re-infection rates. Identifying the optimal irrigation agent, however, remains challenging, as there is limited data on superiority. Direct comparison of different irrigation solutions remains difficult because of variability in treatment protocols. While basic science studies assist in the selection of irrigation fluids, in vitro results do not directly translate into clinical significance once implemented in vivo. Dilute povidone iodine, hydrogen peroxide, chlorhexidine gluconate, acetic acid, sodium hypochlorite, hypochlorous acid, and preformed combination solutions all have potential against a broad spectrum of PJI pathogens with their own unique advantages and disadvantages. Future clinical studies are needed to identify ideal irrigation solutions with optimal bactericidal properties and low cytotoxicity for PJI treatment.


2021 ◽  
Vol 11 (12) ◽  
pp. 5324
Author(s):  
Maria Menini ◽  
Francesca Delucchi ◽  
Domenico Baldi ◽  
Francesco Pera ◽  
Francesco Bagnasco ◽  
...  

(1) Background: Intrinsic characteristics of the implant surface and the possible presence of endotoxins may affect the bone–implant interface and cause an inflammatory response. This study aims to evaluate the possible inflammatory response induced in vitro in macrophages in contact with five different commercially available dental implants. (2) Methods: one zirconia implant NobelPearl® (Nobel Biocare) and four titanium implants, Syra® (Sweden & Martina), Prama® (Sweden & Martina), 3iT3® (Biomet 3i) and Shard® (Mech & Human), were evaluated. After 4 h of contact of murine macrophage cells J774a.1 with the implants, the total RNA was extracted, transcribed to cDNA and the gene expression of the macrophages was evaluated by quantitative PCR (qPCR) in relation to the following genes: GAPDH, YWHAZ, IL1β, IL6, TNFα, NOS2, MMP-9, MMP-8 and TIMP3. The results were statistically analyzed and compared with negative controls. (3) Results: No implant triggered a significant inflammatory response in macrophages, although 3iT3 exhibited a slight pro-inflammatory effect compared to other samples. (4) Conclusions: All the samples showed optimal outcomes without any inflammatory stimulus on the examined macrophagic cells.


2021 ◽  
Vol 11 (14) ◽  
pp. 6353
Author(s):  
Vittoria D’Esposito ◽  
Josè Camilla Sammartino ◽  
Pietro Formisano ◽  
Alessia Parascandolo ◽  
Domenico Liguoro ◽  
...  

Background: The aim of this research was to evaluate the effects of three different titanium (Ti) implant surfaces on the viability and secretory functions of mesenchymal stem cells isolated from a Bichat fat pad (BFP-MSCs). Methods: Four different Ti disks were used as substrate: (I) D1: smooth Ti, as control; (II) D2: chemically etched, resembling the Kontact S surface; (III) D3: sandblasted, resembling the Kontact surface; (IV) D4: blasted/etched, resembling the Kontact N surface. BFP-MSCs were plated on Ti disks for 72 h. Cell viability, adhesion on disks and release of a panel of cytokines, chemokines and growth factor were evaluated. Results: BFP-MSCs plated in wells with Ti surface showed a viability rate (~90%) and proliferative rate comparable to cells plated without disks and to cells plated on D1 disks. D2 and D4 showed the highest adhesive ability. All the Ti surfaces did not interfere with the release of cytokines, chemokines and growth factors by BFP-MSCs. However, BFP-MSCs cultured on D4 surface released a significantly higher amount of Granulocyte Colony-Stimulating Factor (G-CSF) compared either to cells plated without disks and to cells plated on D1 and D2. Conclusions: The implant surfaces examined do not impair the BFP-MSCs cell viability and preserve their secretion of cytokines and chemokines. Further in vitro and in vivo studies are necessary to define the implant surface parameters able to assure the chemokines’ optimal release for a real improvement of dental implant osseointegration.


2021 ◽  
Vol 22 (13) ◽  
pp. 7130
Author(s):  
Jeffersson Krishan Trigo-Gutierrez ◽  
Yuliana Vega-Chacón ◽  
Amanda Brandão Soares ◽  
Ewerton Garcia de Oliveira Mima

Curcumin (CUR) is a natural substance extracted from turmeric that has antimicrobial properties. Due to its ability to absorb light in the blue spectrum, CUR is also used as a photosensitizer (PS) in antimicrobial Photodynamic Therapy (aPDT). However, CUR is hydrophobic, unstable in solutions, and has low bioavailability, which hinders its clinical use. To circumvent these drawbacks, drug delivery systems (DDSs) have been used. In this review, we summarize the DDSs used to carry CUR and their antimicrobial effect against viruses, bacteria, and fungi, including drug-resistant strains and emergent pathogens such as SARS-CoV-2. The reviewed DDSs include colloidal (micelles, liposomes, nanoemulsions, cyclodextrins, chitosan, and other polymeric nanoparticles), metallic, and mesoporous particles, as well as graphene, quantum dots, and hybrid nanosystems such as films and hydrogels. Free (non-encapsulated) CUR and CUR loaded in DDSs have a broad-spectrum antimicrobial action when used alone or as a PS in aPDT. They also show low cytotoxicity, in vivo biocompatibility, and improved wound healing. Although there are several in vitro and some in vivo investigations describing the nanotechnological aspects and the potential antimicrobial application of CUR-loaded DDSs, clinical trials are not reported and further studies should translate this evidence to the clinical scenarios of infections.


2013 ◽  
Vol 39 (3) ◽  
pp. 302-307 ◽  
Author(s):  
V. Manju ◽  
T. Sreelal

In an implant-supported overdenture, the optimal stress distribution on the implants and least denture displacement is desirable. This study compares the load transfer characteristics to the implant and the movement of overdenture among 3 different types of attachments (ball-ring, bar-clip, and magnetic). Stress on the implant surface was measured using the strain-gauge technique and denture displacement by dial gauge. The ball/O-ring produces the optimal stress on the implant body and promotes denture stability.


2010 ◽  
Vol 23 (1) ◽  
pp. 14-34 ◽  
Author(s):  
Graeme N. Forrest ◽  
Kimberly Tamura

SUMMARY The increasing emergence of antimicrobial-resistant organisms, especially methicillin-resistant Staphylococcus aureus (MRSA), has resulted in the increased use of rifampin combination therapy. The data supporting rifampin combination therapy in nonmycobacterial infections are limited by a lack of significantly controlled clinical studies. Therefore, its current use is based upon in vitro or in vivo data or retrospective case series, all with major limitations. A prominent observation from this review is that rifampin combination therapy appears to have improved treatment outcomes in cases in which there is a low organism burden, such as biofilm infections, but is less effective when effective surgery to obtain source control is not performed. The clinical data support rifampin combination therapy for the treatment of prosthetic joint infections due to methicillin-sensitive S. aureus (MSSA) after extensive debridement and for the treatment of prosthetic heart valve infections due to coagulase-negative staphylococci. Importantly, rifampin-vancomycin combination therapy has not shown any benefit over vancomycin monotherapy against MRSA infections either clinically or experimentally. Rifampin combination therapy with daptomycin, fusidic acid, and linezolid needs further exploration for these severe MRSA infections. Lastly, an assessment of the risk-benefits is needed before the addition of rifampin to other antimicrobials is considered to avoid drug interactions or other drug toxicities.


2009 ◽  
Vol 1239 ◽  
Author(s):  
Karla Brammer ◽  
Seunghan Oh ◽  
Sungho Jin

AbstractTwo important goals in stem cell research are to control the cell proliferation without differentiation, and also to direct the differentiation into a specific cell lineage when desired. Recent studies indicate that the nanostructures substantially influence the stem cell behavior. It is well known that mesenchymal stem cells (MSCs) are multipotent stem cells that can differentiate into stromal lineages such as adipocyte, chondrocyte, fibroblast, myocyte, and osteoblast cell types. By examining the cellular behavior of MSCs cultured in vitro on nanostructures, some understanding of the effects that the nanostructures have on the stem cell’s response has been obtained. Here we demonstrate that TiO2 nanotubes produced by anodization on Ti implant surface can regulate human mesenchymal stem cell (hMSC) differentiation towards an osteoblast lineage in the absence of osteogenic inducing factors. Altering the dimensions of nanotubular-shaped titanium oxide surface structures independently allowed either augmented human mesenchymal stem cell (hMSC) adhesion at smaller diameter levels or a specific differentiation of hMSCs into osteoblasts using only the geometric cues. Small (˜30 nm diameter) nanotubes promoted adhesion without noticeable differentiation, while larger (˜70 - 100 nm diameter) nanotubes elicited a dramatic, ˜10 fold stem cell elongation, which induced cytoskeletal stress and selective differentiation into osteoblast-like cells, offering a promising nanotechnology-based route for novel orthopaedics-related hMSC treatments. The fact that a guided and preferential osteogenic differentiation of stem cells can be achieved using substrate nanotopography alone without using potentially toxic, differentiation-inducing chemical agents is significant, which can be useful for future development of novel and enhanced stem cell control and therapeutic implant development.


Biomaterials ◽  
2001 ◽  
Vol 22 (8) ◽  
pp. 827-832 ◽  
Author(s):  
M. Werthén ◽  
A. Sellborn ◽  
M. Källtorp ◽  
H. Elwing ◽  
P. Thomsen

2021 ◽  
Vol 9 (2) ◽  
pp. 428
Author(s):  
María Carmen Sánchez ◽  
Andrea Alonso-Español ◽  
Honorato Ribeiro-Vidal ◽  
Bettina Alonso ◽  
David Herrera ◽  
...  

Microbial biofilm modeling has improved in sophistication and scope, although only a limited number of standardized protocols are available. This review presents an example of a biofilm model, along with its evolution and application in studying periodontal and peri-implant diseases. In 2011, the ETEP (Etiology and Therapy of Periodontal and Peri-Implant Diseases) research group at the University Complutense of Madrid developed an in vitro biofilm static model using representative bacteria from the subgingival microbiota, demonstrating a pattern of bacterial colonization and maturation similar to in vivo subgingival biofilms. When the model and its methodology were standardized, the ETEP research group employed the validated in vitro biofilm model for testing in different applications. The evolution of this model is described in this manuscript, from the mere observation of biofilm growth and maturation on static models on hydroxyapatite or titanium discs, to the evaluation of the impact of dental implant surface composition and micro-structure using the dynamic biofilm model. This evolution was based on reproducing the ideal microenvironmental conditions for bacterial growth within a bioreactor and reaching the target surfaces using the fluid dynamics mimicking the salivary flow. The development of this relevant biofilm model has become a powerful tool to study the essential processes that regulate the formation and maturation of these important microbial communities, as well as their behavior when exposed to different antimicrobial compounds.


Sign in / Sign up

Export Citation Format

Share Document