scholarly journals Effectiveness of endoscopic intranasal incision reduction for nasal fractures

Author(s):  
Shu Yan ◽  
Yan Jiang ◽  
Yan Wang ◽  
Kaixuan Chen ◽  
Xudong Yan ◽  
...  

Abstract Purpose To report our experience using endoscopic intranasal incision reduction (EIIR) for nasal fractures and to assess effectiveness of the method. Methods 30 patients who underwent EIIR were retrospectively analysed. All the patients were examined by three-dimensional computed tomography (3D CT), acoustic rhinometry and rhinomanometry, preoperatively and postoperatively at 1 month. The visual analogue scale (VAS) was used to assess the preoperative aesthetics and nasal airflow satisfaction and at 1, 3 and 6 months postoperatively. VAS aesthetic satisfaction was also scored by two junior doctors. Results 3D CT showed that the fracture fragments fitted well in 30 patients postoperatively at 1 month. VAS aesthetics and nasal airflow scores were significantly improved postoperatively at 1, 3 and 6 months compared with preoperative scores (P < 0.01). The VAS aesthetic scores from the two surgeons were also significantly improved (P < 0.01). The minimal cross-sectional area increased from 0.39 ± 0.13 to 0.64 ± 0.13 (P < 0.001), the nasal volume increased from 4.65 ± 0.86 to 6.37 ± 0.94 (P < 0.001) and the total inspiratory airway resistance of the bilateral nasal cavity median decreased from 0.467 Pa/mL/s to 0.193 Pa/mL/s (P < 0.001). There were no technique-related intraoperative complications. Conclusion EIIR was a practical choice, and the aesthetics and nasal airflow were significantly improved in patients with overlapped and displaced bone fragments, patients with fractures of the frontal process of the maxilla (FFPM), patients who underwent failed CR and patients beyond the optimal temporal window.

2003 ◽  
Vol 14 (3) ◽  
pp. 203-208 ◽  
Author(s):  
Adriana Paula de Andrade da Costa e Silva ◽  
José Leopoldo Ferreira Antunes ◽  
Marcelo Gusmão Paraiso Cavalcanti

Computed tomography (CT) has been increasingly used in the examination of patients with craniofacial trauma. This technique is useful in the examination of the temporomandibular joint and allows the diagnosis of fractures of the mandibular condyle. Aiming to verify whether the three-dimensional reconstructed images from CT (3D-CT) produce more effective visual information than the two-dimensional (2D-CT) ones, we evaluated 2D-CT and 3D-CT examinations of 18 patients with mandibular condyle fractures. We observed that 2D-CT and 3D-CT reconstructed images produced similar information for the diagnosis of fractures of the mandibular condyle, although the 3D-CT allowed a better visualization of the position and displacement of bone fragments, as well as the comminution of fractures. These results, together with the possibility of refining and manipulating perspectives in 3D images, reinforce the importance of its use in the surgical planning and evaluation of treatment. We concluded that 3D-CT presented supplementary information for a more effective diagnosis of mandibular condyle fractures.


2021 ◽  
Vol 20 ◽  
pp. e219912
Author(s):  
Victor Nogueira Moura ◽  
Emerson Nogueira ◽  
Ewerton Daniel Rocha Rodrigues ◽  
Caio Gonçalves Silva ◽  
Ricardo José De Holanda Vasconcellos

Aim: Evaluation of the reliability of 3D computed tomography (3D-CT) in the diagnosis of mandibular fractures. Methods: A cross-sectional, quantitative and qualitative study was carried out, through the application of a questionnaire for 70 professionals in the area of Oral and Maxillofacial Surgery and Radiology. 3D-CT images of mandibular fractures were delivered to the interviewees along with a questionnaire. Participants answered about the number of traces, the region and the type of fracture. The correct diagnosis, that is, the expected answer, was based on the reports of a specialist in oral and maxillofacial radiology after viewing the images in the axial, sagittal and coronal sections. The resulting data from the interviewees was compared with the expected answer and then, the data was analyzed statistically. Results: In the sample 56.9% were between 22 and 30 years old, 52.8% were oral and maxillofacial surgeons (OMF), 34.7% were residents in OMF surgery and 12.5% OMF radiologists. Each professional answered 15 questions (related to five patients) and 50.8% of the total of these was answered correctly. Specialists in Oral and Maxillofacial Surgery and Traumatology correctly answered 53.9%. Interviewees with experience between 6 and 10 years correctly answered 58.2%. In identifying fracture traces, 46.1% of the questions were answered correctly. In terms of location, 5.6% of interviewees answered wrongly while 14.2% answered wrongly regarding classification. Conclusion: 3D computed tomography did not prove to be a reliable image for diagnosing mandibular fractures when used alone. This made necessary an association with axial, sagittal and coronal tomographic sections.


Author(s):  
Zi Fen Lim ◽  
Parvathy Rajendran ◽  
Muhamad Yusri Musa ◽  
Chih Fang Lee

AbstractA numerical simulation of a patient’s nasal airflow was developed via computational fluid dynamics. Accordingly, computerized tomography scans of a patient with septal deviation and allergic rhinitis were obtained. The three-dimensional (3D) nasal model was designed using InVesalius 3.0, which was then imported to (computer aided 3D interactive application) CATIA V5 for modification, and finally to analysis system (ANSYS) flow oriented logistics upgrade for enterprise networks (FLUENT) to obtain the numerical solution. The velocity contours of the cross-sectional area were analyzed on four main surfaces: the vestibule, nasal valve, middle turbinate, and nasopharynx. The pressure and velocity characteristics were assessed at both laminar and turbulent mass flow rates for both the standardized and the patient’s model nasal cavity. The developed model of the patient is approximately half the size of the standardized model; hence, its velocity was approximately two times more than that of the standardized model.


2018 ◽  
Vol 64 (5) ◽  
pp. 645-650
Author(s):  
Olga Kravets ◽  
Yelena Romanova ◽  
Oleg Kozlov ◽  
Mikhail Nechushkin ◽  
A. Gavrilova ◽  
...  

We present our results of 3D CT/MRI brachytherapy (BT) planning in 115 patients with locally advanced cervical cancer T2b-3bN0-1M0. The aim of this study was to assess the differences in the visualization of tumor target volumes and risk organs during the 3D CT/MRI BT. The results of the study revealed that the use of MRI imaging for dosimetric planning of dose distribution for a given volume of a cervical tumor target was the best method of visualization of the soft tissue component of the tumor process in comparison with CT images, it allowed to differentially visualize the cervix and uterine body, directly the tumor volume. Mean D90 HR-CTV for MRI was 32.9 cm3 versus 45.9 cm3 for CT at the time of first BT, p = 0.0002, which is important for local control of the tumor process. The contouring of the organs of risk (bladder and rectum) through MRI images allows for more clearly visualizing the contours, which statistically significantly reduces the dose load for individual dosimetric planning in the D2cc control volume, і.є. the minimum dose of 2 cm3 of the organ of risk: D2cc for the bladder was 24.3 Gy for MRI versus 34.8 Gy on CT (p = 0.045); D2cc for the rectum - 18.7 Gy for MRI versus 26.8 Gy for CT (p = 0.046). This is a prognostically important stage in promising local control, which allows preventing manifestation of radiation damage.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


2021 ◽  
Vol 11 (8) ◽  
pp. 3404
Author(s):  
Majid Hejazian ◽  
Eugeniu Balaur ◽  
Brian Abbey

Microfluidic devices which integrate both rapid mixing and liquid jetting for sample delivery are an emerging solution for studying molecular dynamics via X-ray diffraction. Here we use finite element modelling to investigate the efficiency and time-resolution achievable using microfluidic mixers within the parameter range required for producing stable liquid jets. Three-dimensional simulations, validated by experimental data, are used to determine the velocity and concentration distribution within these devices. The results show that by adopting a serpentine geometry, it is possible to induce chaotic mixing, which effectively reduces the time required to achieve a homogeneous mixture for sample delivery. Further, we investigate the effect of flow rate and the mixer microchannel size on the mixing efficiency and minimum time required for complete mixing of the two solutions whilst maintaining a stable jet. In general, we find that the smaller the cross-sectional area of the mixer microchannel, the shorter the time needed to achieve homogeneous mixing for a given flow rate. The results of these simulations will form the basis for optimised designs enabling the study of molecular dynamics occurring on millisecond timescales using integrated mix-and-inject microfluidic devices.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Zhe Li ◽  
Guanzhi Liu ◽  
Run Tian ◽  
Ning Kong ◽  
Yue Li ◽  
...  

Abstract Background Our objective was to obtain normal patellofemoral measurements to analyse sex and individual differences. In addition, the absolute values and indices of tibial tuberosity-trochlear groove (TT-TG) distances are still controversial in clinical application. A better method to enable precise prediction is still needed. Methods Seventy-eight knees of 78 participants without knee pathologies were included in this cross-sectional study. A CT scan was conducted for all participants and three-dimensional knee models were constructed using Mimics and SolidWorks software. We measured and analysed 19 parameters including the TT-TG distance and dimensions and shapes of the patella, femur, tibia, and trochlea. LASSO regression was used to predict the normal TT-TG distances. Results The dimensional parameters, TT-TG distance, and femoral aspect ratio of the men were significantly larger than those of women (all p values < 0.05). However, after controlling for the bias from age, height, and weight, there were no significant differences in TT-TG distances and anterior-posterior dimensions between the sexes (all p values > 0.05). The Pearson correlation coefficients between the anterior femoral offset and other indexes were consistently below 0.3, indicating no relationship or a weak relationship. Similar results were observed for the sulcus angle and the Wiberg index. Using LASSO regression, we obtained four parameters to predict the TT-TG distance (R2 = 0.5612, p < 0.01) to achieve the optimal accuracy and convenience. Conclusions Normative data of patellofemoral morphology were provided for the Chinese population. The anterior-posterior dimensions of the women were thicker than those of men for the same medial-lateral dimensions. More attention should be paid to not only sex differences but also individual differences, especially the anterior condyle and trochlea. In addition, this study provided a new method to predict TT-TG distances accurately.


2021 ◽  
Vol 45 (3) ◽  
Author(s):  
C. M. Durnea ◽  
S. Siddiqi ◽  
D. Nazarian ◽  
G. Munneke ◽  
P. M. Sedgwick ◽  
...  

AbstractThe feasibility of rendering three dimensional (3D) pelvic models of vaginal, urethral and paraurethral lesions from 2D MRI has been demonstrated previously. To quantitatively compare 3D models using two different image processing applications: 3D Slicer and OsiriX. Secondary analysis and processing of five MRI scan based image sets from female patients aged 29–43 years old with vaginal or paraurethral lesions. Cross sectional image sets were used to create 3D models of the pelvic structures with 3D Slicer and OsiriX image processing applications. The linear dimensions of the models created using the two different methods were compared using Bland-Altman plots. The comparisons demonstrated good agreement between measurements from the two applications. The two data sets obtained from different image processing methods demonstrated good agreement. Both 3D Slicer and OsiriX can be used interchangeably and produce almost similar results. The clinical role of this investigation modality remains to be further evaluated.


2017 ◽  
Vol 2017 ◽  
pp. 1-13
Author(s):  
Xin Wan ◽  
Ximing Liu ◽  
Jichen Miao ◽  
Peng Cong ◽  
Yuai Zhang ◽  
...  

Pebble dynamics is important for the safe operation of pebble-bed high temperature gas-cooled reactors and is a complicated problem of great concern. To investigate it more authentically, a computed tomography pebble flow detecting (CT-PFD) system has been constructed, in which a three-dimensional model is simulated according to the ratio of 1 : 5 with the core of HTR-PM. A multislice helical CT is utilized to acquire the reconstructed cross-sectional images of simulated pebbles, among which special tracer pebbles are designed to indicate pebble flow. Tracer pebbles can be recognized from many other background pebbles because of their heavy kernels that can be resolved in CT images. The detecting principle and design parameters of the system were demonstrated by a verification experiment on an existing CT system in this paper. Algorithms to automatically locate the three-dimensional coordinates of tracer pebbles and to rebuild the trajectory of each tracer pebble were presented and verified. The proposed pebble-detecting and tracking technique described in this paper will be implemented in the near future.


Sign in / Sign up

Export Citation Format

Share Document