scholarly journals Use of pooled serum samples to assess herd disease status using commercially available ELISAs

2021 ◽  
Vol 53 (5) ◽  
Author(s):  
Juan Heberth Hernandez-Medrano ◽  
Luis Fernando Espinosa-Castillo ◽  
Ana D. Rodriguez ◽  
Carlos G. Gutierrez ◽  
Wendela Wapenaar

AbstractPooled samples are used in veterinary and human medicine as a cost-effective approach to monitor disease prevalence. Nonetheless, there is limited information on the effect of pooling on test performance, and research is required to determine the appropriate number of samples which can be pooled. Therefore, this study aimed to evaluate the use of pooled serum samples as a herd-level surveillance tool for infectious production-limiting diseases: bovine viral diarrhoea (BVD), infectious bovine rhinotracheitis (IBR), enzootic bovine leukosis (EBL) and Neospora caninum (NC), by investigating the maximum number of samples one can pool to identify one positive animal, using commercial antibody-detection ELISAs. Four positive field standards (PFS), one for each disease, were prepared by pooling highly positive herd-level samples diagnosed using commercially available ELISA tests. These PFS were used to simulate 18 pooled samples ranging from undiluted PFS to a dilution representing 1 positive in 1,000 animals using phosphate-buffered saline as diluent. A 1:10 dilution of the PFS resulted in positive results for IBR, BVD and EBL. Moreover, for IBR and BVD, results were still positive at 1:100 and 1:30 dilutions, respectively. However, for NC, a lower dilution (8:10) was required for a seropositive result. This study indicates that, at herd-level, the use of pooled serum is a useful strategy for monitoring infectious diseases (BVD, IBR and EBL) but not NC, using readily available diagnostic assays.

2009 ◽  
Vol 16 (5) ◽  
pp. 605-612 ◽  
Author(s):  
Rena Greenwald ◽  
Olena Lyashchenko ◽  
Javan Esfandiari ◽  
Michele Miller ◽  
Susan Mikota ◽  
...  

ABSTRACT Tuberculosis (TB) in elephants is a reemerging zoonotic disease caused primarily by Mycobacterium tuberculosis. Current methods for screening and diagnosis rely on trunk wash culture, which has serious limitations due to low test sensitivity, slow turnaround time, and variable sample quality. Innovative and more efficient diagnostic tools are urgently needed. We describe three novel serologic techniques, the ElephantTB Stat-Pak kit, multiantigen print immunoassay, and dual-path platform VetTB test, for rapid antibody detection in elephants. The study was performed with serum samples from 236 captive African and Asian elephants from 53 different locations in the United States and Europe. The elephants were divided into three groups based on disease status and history of exposure: (i) 26 animals with culture-confirmed TB due to M. tuberculosis or Mycobacterium bovis, (ii) 63 exposed elephants from known-infected herds that had never produced a culture-positive result from trunk wash samples, and (iii) 147 elephants without clinical symptoms suggestive of TB, with consistently negative trunk wash culture results, and with no history of potential exposure to TB in the past 5 years. Elephants with culture-confirmed TB and a proportion of exposed but trunk wash culture-negative elephants produced robust antibody responses to multiple antigens of M. tuberculosis, with seroconversions detectable years before TB-positive cultures were obtained from trunk wash specimens. ESAT-6 and CFP10 proteins were immunodominant antigens recognized by elephant antibodies during disease. The serologic assays demonstrated 100% sensitivity and 95 to 100% specificity. Rapid and accurate antibody tests to identify infected elephants will likely allow earlier and more efficient treatment, thus limiting transmission of infection to other susceptible animals and to humans.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hatairat Lerdsamran ◽  
Anek Mungaomklang ◽  
Sopon Iamsirithaworn ◽  
Jarunee Prasertsopon ◽  
Kriengkrai Prasert ◽  
...  

Abstract Background Antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) help determine previous infection in individuals, regardless of whether they are asymptomatic or symptomatic. The detection of antibodies serves several purposes, including supporting other assays for disease diagnosis, conducting seroepidemiological studies, and evaluating vaccines. Many platforms of immunological methods for anti-SARS-CoV-2 antibody detection and their performance require validation. Methods This study evaluated the test performance of three autoanalyzer-based assays (Architect IgG, Vitros IgG, and Vitros total Ig) and one manual ELISA (Wantai total Ig) against a microneutralization (microNT) assay on the detection of SARS-CoV-2 antibodies. Furthermore, an indirect immunofluorescence assay verified the discordant results between the microNT and commercial assays. The test sensitivity, specificity, positive predictive value, and negative predictive value were determined based on four groups of 1005 serum samples: 102 COVID-19 prepandemic sera, 45 anti-SARS-CoV-2 positive sera, 366 sera of people at risk, and 492 sera of citizens returning from countries with a high prevalence of infection. Results The analyses as a whole showed that the performance of these commercial assays was comparable. Each group was also analysed separately to gain further insight into test performance. The Architect did not detect two positive sera of people at risk (prevalence of infection 0.55%). The other methods correctly identified these two positive sera but yielded varying false-positive results. The group of returning travellers with an infection rate of 28.3% (139 of 492) better differentiated the test performance of individual assays. Conclusions High-throughput Architect and Vitros autoanalyzers appear appropriate for working on large sample sizes in countries that can afford the cost. The Wantai ELISA, while requiring more individual time and technical skill, may provide reliable results at a lower cost. The selection of assays will depend on the laboratory facilities and feasibility.


2001 ◽  
Vol 47 (1) ◽  
pp. 110-117 ◽  
Author(s):  
Magnus Jonsson ◽  
Joyce Carlson ◽  
Jan-Olof Jeppsson ◽  
Per Simonsson

Abstract Background: Electrophoresis of serum samples allows detection of monoclonal gammopathies indicative of multiple myeloma, Waldenström macroglobulinemia, monoclonal gammopathy of undetermined significance, and amyloidosis. Present methods of high-resolution agarose gel electrophoresis (HRAGE) and immunofixation electrophoresis (IFE) are manual and labor-intensive. Capillary zone electrophoresis (CZE) allows rapid automated protein separation and produces digital absorbance data, appropriate as input for a computerized decision support system. Methods: Using the Beckman Paragon CZE 2000 instrument, we analyzed 711 routine clinical samples, including 95 monoclonal components (MCs) and 9 cases of Bence Jones myeloma, in both the CZE and HRAGE systems. Mathematical algorithms developed for the detection of monoclonal immunoglobulins (MCs) in the γ- and β-regions of the electropherogram were tested on the entire material. Additional algorithms evaluating oligoclonality and polyclonal concentrations of immunoglobulins were also tested. Results: CZE electropherograms corresponded well with HRAGE. Only one IgG MC of 1 g/L, visible on HRAGE, was not visible after CZE. Algorithms detected 94 of 95 MCs (98.9%) and 100% of those visible after CZE. Of 607 samples lacking an MC on HRAGE, only 3 were identified by the algorithms (specificity, 99%). Algorithms evaluating total gammaglobulinemia and oligoclonality also identified several cases of Bence Jones myeloma. Conclusions: The use of capillary electrophoresis provides a modern, rapid, and cost-effective method of analyzing serum proteins. The additional option of computerized decision support, which provides rapid and standardized interpretations, should increase the clinical availability and usefulness of protein analyses in the future.


Biostatistics ◽  
2019 ◽  
Author(s):  
Dane R Van Domelen ◽  
Emily M Mitchell ◽  
Neil J Perkins ◽  
Enrique F Schisterman ◽  
Amita K Manatunga ◽  
...  

SUMMARYMeasuring a biomarker in pooled samples from multiple cases or controls can lead to cost-effective estimation of a covariate-adjusted odds ratio, particularly for expensive assays. But pooled measurements may be affected by assay-related measurement error (ME) and/or pooling-related processing error (PE), which can induce bias if ignored. Building on recently developed methods for a normal biomarker subject to additive errors, we present two related estimators for a right-skewed biomarker subject to multiplicative errors: one based on logistic regression and the other based on a Gamma discriminant function model. Applied to a reproductive health dataset with a right-skewed cytokine measured in pools of size 1 and 2, both methods suggest no association with spontaneous abortion. The fitted models indicate little ME but fairly severe PE, the latter of which is much too large to ignore. Simulations mimicking these data with a non-unity odds ratio confirm validity of the estimators and illustrate how PE can detract from pooling-related gains in statistical efficiency. These methods address a key issue associated with the homogeneous pools study design and should facilitate valid odds ratio estimation at a lower cost in a wide range of scenarios.


Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1192
Author(s):  
Hisham S. M. Abd-Rabboh ◽  
Abd El-Galil E. Amr ◽  
Abdulrahman A. Almehizia ◽  
Ayman H. Kamel

In recent times, the application of the use of ion-selective electrodes has expanded in the field of pharmaceutical analyses due to their distinction from other sensors in their high selectivity and low cost of measurement, in addition to their high measurement sensitivity. Cost-effective, reliable, and robust all-solid-state potentiometric selective electrodes were designed, characterized, and successfully used for pholcodine determination. The design of the sensor device was based on the use of a screen-printed electrode modified with multiwalled carbon nanotubes (MWCNTs) as a solid-contact transducer. Tailored pholcodine (PHO) molecularly imprinted polymers (MIPs) were prepared, characterized, and used as sensory receptors in the presented potentiometric sensing devices. The sensors exhibited a sensitivity of 31.6 ± 0.5 mV/decade (n = 5, R2 = 0.9980) over the linear range of 5.5 × 10−6 M with a detection limit of 2.5 × 10−7 M. Real serum samples in addition to pharmaceutical formulations containing PHO were analyzed, and the results were compared with those obtained by the conventional standard liquid chromatographic approach. The presented analytical device showed an outstanding efficiency for fast, direct, and low-cost assessment of pholcodine levels in different matrices.


2021 ◽  
Vol 17 (1) ◽  
Author(s):  
Zicheng Ma ◽  
Mengda Liu ◽  
Zhaohu Liu ◽  
Fanliang Meng ◽  
Hongyu Wang ◽  
...  

Abstract Background Porcine circovirus type 2 (PCV2) is one of the crucial swine viral pathogens, caused porcine circovirus associated diseases (PCVAD). Shandong province is one of the most important pork producing areas and bears a considerable economic loss due to PCVAD. However, there is limited information on epidemiology and coinfection rate of PCV2 with other critical swine diseases in this area, such as porcine reproductive and respiratory syndrome virus (PRRSV), classical swine fever virus (CSFV), Pseudorabies virus (PRV), and porcine epidemic diarrhea virus (PEDV). Results Overall, 89.59% serum samples and 36.98% tissue samples were positive for PCV2 specified ELISA and PCR positive for PCV2, respectively. The coinfection rates of PCV2 with PRRSV, PRV, CSFV, and PEDV were 26.73%, 18.37%, 13.06%, and 3.47%, respectively. Moreover, genetic characteristic of PCV2 were analyzed based on the cap genes showing that PCV2d is the dominant sub-genotype circulating in the province. Conclusions Our findings reveal that PCV2d, as the dominant strain, is prevailing in pig farms in Shandong province at high levels. There was a high frequency of coinfection of PCV2 and PRRSV.


2021 ◽  
Vol 18 (1) ◽  
Author(s):  
Atiporn Boonyai ◽  
Anchalee Thongput ◽  
Thidarat Sisaeng ◽  
Parisut Phumchan ◽  
Navin Horthongkham ◽  
...  

Abstract Background Prevalence and incidence of hepatitis caused by HEV infection are usually higher in developing countries. This study demonstrated the HEV seroprevalence and incidence of HEV infection in patients with clinical hepatitis in a tertiary hospital in Thailand. Methods A laboratory-based cross-sectional study was conducted using 1106 serum samples from patients suspected of HEV infection sent to the Serology laboratory, Siriraj Hospital, for detecting HEV antibodies during 2015–2018. Prevalence of anti-HEV IgG and IgM antibodies in general patients, including organ transplant recipients and pregnant women in a hospital setting, were determined using indirect enzyme-linked immunosorbent assay (ELISA) kits. Comparison of laboratory data between groups with different HEV serological statuses was performed. Results HEV IgG antibodies were detected in 40.82% of 904 serum samples, while HEV IgM antibodies were detected in 11.75% of 1081 serum samples. Similar IgG and IgM antibody detection rates were found in pregnant women. Interestingly, anti-HEV IgM antibodies were detected in 38.5% of patients who underwent organ transplantation. Patients who tested positive for anti-HEV IgM antibodies had higher alanine aminotransferase levels than those who had not. In contrast, patients who tested positive for anti-HEV IgG had more elevated levels of total bilirubin than those who tested negative. Conclusions HEV seroprevalence and incidence in patients with clinical hepatitis were relatively high in the Thai population, including the pregnancy and organ transplant subgroups. The results potentially benefit the clinicians in decision-making to investigate HEV antibodies and facilitating proper management for patients.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Huseyin Agah Terzi ◽  
Ozlem Aydemir ◽  
Engin Karakece ◽  
Huseyin Hatipoglu ◽  
Mehmet Olmez ◽  
...  

AbstractObjectivesTo test the performance of the newly available rapid test for syphilis, we compared it with Treponema pallidum hemagglutination assay (TPHA). Additionally, we investigated the performance of rapid plasma reagin (RPR) and chemiluminescence microparticle immunoassays (CMIA) at our laboratory using TPHA as a gold standard.MethodsThe serum samples of 595 patients with the pre-diagnosis of syphilis were studied by four serological methods. The sensitivity, specificity, and predictive values of RPR, CMIA, and syphilis rapid test were assessed by utilizing TPHA as a gold standard for the diagnosis of syphilis.ResultsOf the patients, 6.2% (37/595) had positive RPR, 5.5% (33/595) had positive CMIA, 5.5% (33/595) had a positive rapid immunochromatographic method and 5% (30/595) had positive TPHA. When TPHA results were taken as the reference, the sensitivity of the rapid test for syphilis was 100%, the specificity was 99.5%, PPV was 90.9%, and NPV was 100.0%.ConclusionsIt was observed that the rapid test for syphilis used in the study was quite successful, its cost was appropriate, and the test was very fast and easy to apply. At the same time, the agreement between syphilis rapid test and TPHA was found to be excellent.


2003 ◽  
Vol 10 (2) ◽  
pp. 317-322 ◽  
Author(s):  
Angel Balmaseda ◽  
María G. Guzmán ◽  
Samantha Hammond ◽  
Guillermo Robleto ◽  
Carolina Flores ◽  
...  

ABSTRACT To evaluate alternative approaches to the serological diagnosis of dengue virus (DEN) infection, the detection of DEN-specific immunoglobulin M (IgM) and IgA antibodies in serum and saliva specimens was assessed in 147 patients with symptoms of DEN infection seen at the Ministry of Health in Nicaragua. Seventy-two serum samples were determined to be positive for anti-DEN antibodies by IgM capture enzyme-linked immunosorbent assay, the routine diagnostic procedure. Serum and saliva specimens were obtained from 50 healthy adults as additional controls. IgM was detected in the saliva of 65 of the 72 serum IgM-positive cases, 6 of the 75 serum IgM-negative cases, and none of the control group, resulting in a sensitivity of 90.3% and a specificity of 92.0% and demonstrating that salivary IgM is a useful diagnostic marker for DEN infection. Detection of IgA in serum may be another feasible alternative for the diagnosis of DEN infection, with serum IgA found in 68 (94.4%) of the IgM-positive cases. In contrast, detection of IgA in saliva was not found to be a useful tool for DEN diagnosis in the present study. Further studies of the kinetics of antibody detection in another set of 151 paired acute- and convalescent-phase serum samples showed that DEN-specific IgA antibodies were detected in more acute-phase samples than were IgM antibodies. Thus, we conclude that DEN-specific IgA in serum is a potential diagnostic target. Furthermore, given that saliva is a readily obtainable, noninvasive specimen, detection of DEN-specific salivary IgM should be considered a useful, cheaper diagnostic modality with similar sensitivity and specificity to IgM detection in serum.


Author(s):  
Shani Van Lochem ◽  
Peter N. Thompson ◽  
Cornelius H. Annandale

The prevalence of nasal carrier status of methicillin-resistant Staphylococcus aureus (MRSA) in pigs has been described elsewhere, but is unknown in South Africa. To address concerns that exist regarding the zoonotic risk that carriers pose to workers, the herd-level prevalence of MRSA was determined among 25 large (> 500 sows) commercial pig herds in South Africa, representing 45% of the large commercial herds in the country. From each herd, the nasal contents of 18 finisher pigs were sampled at the abattoir, pooled into three and selectively cultured to determine the presence of MRSA. A herd was classified as MRSA-positive if one or more of the three pooled samples cultured positive. Three of the 25 herds tested positive for MRSA, equating to a 12% herd prevalence (95% CI: 7% – 23%) among South African commercial piggeries. The prevalence of nasal MRSA carriers among large commercial pig herds in South Africa was low compared to what has been reported elsewhere and suggests a relatively low zoonotic MRSA risk to workers in South African commercial piggeries and abattoirs.


Sign in / Sign up

Export Citation Format

Share Document