Anaerobic treatment of tequila vinasses under seasonal operating conditions: Start-up, normal operation and restart-up after a long stop and starvation period

2014 ◽  
Vol 168 ◽  
pp. 33-40 ◽  
Author(s):  
J.A. Jáuregui-Jáuregui ◽  
H.O. Méndez-Acosta ◽  
V. González-Álvarez ◽  
R. Snell-Castro ◽  
V. Alcaraz-González ◽  
...  
1992 ◽  
Vol 25 (10) ◽  
pp. 149-162 ◽  
Author(s):  
V. L. Pillay ◽  
C. A. Buckley

Cross-flow microfiltration (CFMF) has potentially wide application in the processing of industrial and domestic waste waters. Optimum design and operation of CFMF systems necessitates a knowledge of the characteristic system behaviour, and an understanding of the mechanisms governing this behaviour. This paper is a contribution towards the elucidation and understanding of the behaviour of a woven fibre CFMF operated in the turbulent flow regime. The characteristic flux-time curve and effects of operating variables on flux are presented for a limestone suspension cross-flow filtered in a 25 mm woven fibre tube. The phenomena contributing to the shape of the flux-time curve are discussed. A model of the mechanisms governing cake growth and limit is presented. Predicted steady-state fluxes show a notably good correspondence with experimentally measured values. It is also found that the flux may not be uniquely defined by the operating conditions, but may also be a function of the operating path taken to reach the operating point. This is of significance in the start-up and operation of CFMF units.


1999 ◽  
Vol 40 (8) ◽  
pp. 229-236 ◽  
Author(s):  
F. Fdz-Polanco ◽  
M. D. Hidalgo ◽  
M. Fdz-Polanco ◽  
P. A. García Encina

In the last decade Polyethylene Terephthalate (PET) production is growing. The wastewater of the “Catalana de Polimers” factory in Barcelona (Spain) has two main streams of similar flow rate, esterification (COD=30,000 mg/l) and textile (COD=4000 mg/l). In order to assess the anaerobic treatment viability, discontinuous and continuous experiments were carried out. Discontinuous biodegradability tests indicated that anaerobic biodegradability was 90 and 75% for esterification and textile wastewater. The textile stream revealed some tendency to foam formation and inhibitory effects. Nutrients, micronutrients and alkali limitations and dosage were determined. A continuous lab-scale UASB reactor was able to treat a mixture of 50% (v) esterification/textile wastewater with stable behaviour at organic loading rate larger than 12 g COD/l.d (0.3 g COD/g VSS.d) with COD removal efficiency greater than 90%. The start-up period was very short and the recuperation after overloading accidents was quite fast, in spite of the wash-out of solids. From the laboratory information an industrial treatment plant was designed and built, during the start-up period COD removal efficiencies larger than 90% and organic loading rate of 0.6 kg COD/kg VSS.d (5 kg COD/m3.d) have been reached.


2021 ◽  
Vol 13 (15) ◽  
pp. 8620
Author(s):  
Sanaz Salehi ◽  
Kourosh Abdollahi ◽  
Reza Panahi ◽  
Nejat Rahmanian ◽  
Mozaffar Shakeri ◽  
...  

Phenol and its derivatives are hazardous, teratogenic and mutagenic, and have gained significant attention in recent years due to their high toxicity even at low concentrations. Phenolic compounds appear in petroleum refinery wastewater from several sources, such as the neutralized spent caustic waste streams, the tank water drain, the desalter effluent and the production unit. Therefore, effective treatments of such wastewaters are crucial. Conventional techniques used to treat these wastewaters pose several drawbacks, such as incomplete or low efficient removal of phenols. Recently, biocatalysts have attracted much attention for the sustainable and effective removal of toxic chemicals like phenols from wastewaters. The advantages of biocatalytic processes over the conventional treatment methods are their ability to operate over a wide range of operating conditions, low consumption of oxidants, simpler process control, and no delays or shock loading effects associated with the start-up/shutdown of the plant. Among different biocatalysts, oxidoreductases (i.e., tyrosinase, laccase and horseradish peroxidase) are known as green catalysts with massive potentialities to sustainably tackle phenolic contaminants of high concerns. Such enzymes mainly catalyze the o-hydroxylation of a broad spectrum of environmentally related contaminants into their corresponding o-diphenols. This review covers the latest advancement regarding the exploitation of these enzymes for sustainable oxidation of phenolic compounds in wastewater, and suggests a way forward.


2021 ◽  
Vol 11 (13) ◽  
pp. 5803
Author(s):  
Antonio Lara-Musule ◽  
Ervin Alvarez-Sanchez ◽  
Gloria Trejo-Aguilar ◽  
Laura Acosta-Dominguez ◽  
Hector Puebla ◽  
...  

Anaerobic treatment is a viable alternative for the treatment of agro-industrial waste. Anaerobic digestion reduces organic load and produces volatile fatty acids (VFA), which are precursors of value-added products such as methane-rich biogas, biohydrogen, and biopolymers. Nowadays, there are no low-cost diagnosis and monitoring systems that analyze the dynamic behavior of key variables in real time, representing a significant limitation for its practical implementation. In this work, the feasibility of using the multiscale analysis to diagnose and monitor the key variables in VFA production by anaerobic treatment of raw cheese whey is presented. First, experiments were carried out to evaluate the performance of the proposed methodology under different operating conditions. Then, experimental pH time series were analyzed using rescaled range (R/S) techniques. Time-series analysis shows that the anaerobic VFA production exhibits a multiscale behavior, identifying three characteristic regions (i.e., three values of Hurst exponent). In addition, the dynamic Hurst exponents show satisfactory correlations with the chemical oxygen demand (COD) consumption and VFA production. The multiscale analysis of pH time series is easy to implement and inexpensive. Hence, it could be used as a diagnosis and indirect monitoring system of key variables in the anaerobic treatment of raw cheese whey.


Author(s):  
Monika Topel ◽  
Björn Laumert ◽  
Åsa Nilsson ◽  
Markus Jöcker

Liberalized electricity market conditions and concentrating solar power technologies call for increased power plant operational flexibility. Concerning the steam turbine component, one key aspect of its flexibility is the capability for fast starts. In current practice, turbine start-up limitations are set by consideration of thermal stress and low cycle fatigue. However, the pursuit of faster starts raises the question whether other thermal phenomena can become a limiting factor to the start-up process. Differential expansion is one of such thermal properties, especially since the design of axial clearances is not included as part of start-up schedule design and because its measurement during operation is often limited or not a possibility at all. The aim of this work is to understand differential expansion behavior with respect to transient operation and to quantify the effect that such operation would have in the design and operation of axial clearances. This was accomplished through the use of a validated thermo-mechanical model that was used to compare differential expansion behavior for different operating conditions of the machine. These comparisons showed that faster starts do not necessarily imply that wider axial clearances are needed, which means that the thermal flexibility of the studied turbine is not limited by differential expansion. However, for particular locations it was also obtained that axial rubbing can indeed become a limiting factor in direct relation to start-up operation. The resulting approach presented in this work serves to avoid over-conservative limitations in both design and operation concerning axial clearances.


1989 ◽  
Vol 21 (4-5) ◽  
pp. 145-155 ◽  
Author(s):  
R. Méndez ◽  
J. M. Lema ◽  
R. Blázquez ◽  
M. Pan ◽  
C. Forjan

We have evaluated the utility of applying anaerobic digestion treatment to the leachates from two landfill sites receiving solid urban refuse from populations of similar standards of living. Both tips are located in the same area and have very similar climates, but they differ as regards the length of time they have been operated. The leachates from the older tip have much lower levels of organic load, 40% of which was refractory to the anaerobic digestion treatment applied. The digestibility of leachates was studied by using a semicontinuous suspended sludge system.It was possible to remove up to 65% of the soluble COD of leachates from the young tip by means of an anaerobic filter working at HRTs less than 2 days. This system proved to be highly stable when its operating conditions were subjected to perturbations similar to those likely to be suffered by a full-scale plant.


2014 ◽  
Vol 14 (4) ◽  
pp. 1142-1151 ◽  
Author(s):  
Xiaoqing Lin ◽  
Qunxing Huang ◽  
Tong Chen ◽  
Xiaodong Li ◽  
Shengyong Lu ◽  
...  

2021 ◽  
Author(s):  
Stefan D. Cich ◽  
J. Jeffrey Moore ◽  
Meera Day Towler ◽  
Jason Mortzheim

Abstract Recent testing has been completed on a 1 MWe supercritical carbon dioxide (sCO2) closed loop recuperated cycle under funding from the US Department of Energy (DOE) Sunshot initiative and industry partners. Some of the goals of this funding included the development of a 1 MWe loop, a 10 MWe turbine, and performance and mechanical testing. One of the key challenges that presented itself was the filling, start-up, and shut down of the entire system. Understanding the loop transient performance is important when having to bring a turbine online, transitioning from peak to partial loading, and also managing routine and emergency shut downs. Due to large changes in density near the critical point for CO2 and its tendency to form dry ice when expanded to atmospheric pressure, managing loop filling and venting is critical in ensuring that components are not damaged. With successful testing up to 715°C and 234 bar, this paper will provide updated data to, “Loop Filling and Start Up with a Closed Loop sCO2 Brayton Cycle [1].” While the previous paper focused on early trips and start up challenges, this paper will focus on the specific challenges at maximum operating conditions, and how the loop was managed when getting up to these high temperatures and pressures and how the loop behaved during a high temperature trip when compared to a controlled shut down from maximum operating conditions.


Machines ◽  
2018 ◽  
Vol 6 (4) ◽  
pp. 63 ◽  
Author(s):  
Xavier Escaler ◽  
Toufik Mebarki

A sample of healthy wind turbines from the same wind farm with identical sizes and designs was investigated to determine the average vibrational signatures of the drive train components during normal operation. The units were variable-speed machines with three blades. The rotor was supported by two bearings, and the drive train connected to an intermediate three-stage planetary/helical gearbox. The nominal 2 MW output power was regulated using blade pitch adjustment. Vibrations were measured in exactly the same positions using the same type of sensors over a six-month period covering the entire range of operating conditions. The data set was preliminary validated to remove outliers based on the theoretical power curves. The most relevant frequency peaks in the rotor, gearbox, and generator vibrations were detected and identified based on averaged power spectra. The amplitudes of the peaks induced by a common source of excitation were compared in different measurement positions. A wind speed dependency of broadband vibration amplitudes was also observed. Finally, a fault detection case is presented showing the change of vibration signature induced by a damage in the gearbox.


Sign in / Sign up

Export Citation Format

Share Document