Toxicity-removal efficiency of Brassica juncea, Chrysopogon zizanioides and Pistia stratiotes to decontaminate biomedical ash under non-chelating and chelating conditions: A pilot- scale phytoextraction study

Chemosphere ◽  
2022 ◽  
Vol 287 ◽  
pp. 132416
Author(s):  
Rena ◽  
Nitesh Premchand Machhirake ◽  
Shraddha Yadav ◽  
Vijai Krishna ◽  
Sunil Kumar
2017 ◽  
Vol 77 (1) ◽  
pp. 70-78 ◽  
Author(s):  
Yanjun Mao ◽  
Xie Quan ◽  
Huimin Zhao ◽  
Yaobin Zhang ◽  
Shuo Chen ◽  
...  

Abstract The activated sludge (AS) process is widely applied in dyestuff wastewater treatment plants (WWTPs); however, the nitrogen removal efficiency is relatively low and the effluent does not meet the indirect discharge standards before being discharged into the industrial park's WWTP. Hence it is necessary to upgrade the WWTP with more advanced technologies. Moving bed biofilm processes with suspended carriers in an aerobic tank are promising methods due to enhanced nitrification and denitrification. Herein, a pilot-scale integrated free-floating biofilm and activated sludge (IFFAS) process was employed to investigate the feasibility of enhancing nitrogen removal efficiency at different hydraulic retention times (HRTs). The results showed that the effluent chemical oxygen demand (COD), ammonium nitrate (NH4+-N) and total nitrogen (TN) concentrations of the IFFAS process were significantly lower than those of the AS process, and could meet the indirect discharge standards. PCR-DGGE and FISH results indicated that more nitrifiers and denitrifiers co-existed in the IFFAS system, promoting simultaneous nitrification and denitrification. Based on the pilot results, the IFFAS process was used to upgrade the full-scale AS process, and the effluent COD, NH4+-N and TN of the IFFAS process were 91–291 mg/L, 10.6–28.7 mg/L and 18.9–48.6 mg/L, stably meeting the indirect discharge standards and demonstrating the advantages of IFFAS in dyestuff wastewater treatment.


2017 ◽  
Vol 77 (4) ◽  
pp. 988-998 ◽  
Author(s):  
Tadesse Alemu ◽  
Andualem Mekonnen ◽  
Seyoum Leta

Abstract In the present study, a pilot scale horizontal subsurface flow constructed wetland (CW) system planted with Phragmites karka; longitudinal profile was studied. The wetland was fed with tannery wastewater, pretreated in a two-stage anaerobic digester followed by a sequence batch reactor. Samples from each CW were taken and analyzed using standard methods. The removal efficiency of the CW system in terms of biological oxygen demand (BOD), chemical oxygen demand (COD), Cr and total coliforms were 91.3%, 90%, 97.3% and 99%, respectively. The removal efficiency for TN, NO3− and NH4+-N were 77.7%, 66.3% and 67.7%, respectively. Similarly, the removal efficiency of SO42−, S2− and total suspended solids (TSS) were 71.8%, 88.7% and 81.2%, respectively. The concentration of COD, BOD, TN, NO3−N, NH4+-N, SO42 and S2− in the final treated effluent were 113.2 ± 52, 56 ± 18, 49.3 ± 13, 22.75 ± 20, 17.1 ± 6.75, 88 ± 120 and 0.4 ± 0.44 mg/L, respectively. Pollutants removal was decreased in the first 12 m and increased along the CW cells. P. karka development in the first cell of CW was poor, small in size and experiencing chlorosis, but clogging was higher in this area due to high organic matter settling, causing a partial surface flow. The performance of the pilot CW as a tertiary treatment showed that the effluent meets the permissible discharge standards.


2020 ◽  
Vol 58 (5A) ◽  
pp. 22
Author(s):  
Dao Thanh Son ◽  
Van Tai Nguyen ◽  
Thuy Nhu Quynh Vo ◽  
Vinh Quang Tran ◽  
Thi My Chi Vo ◽  
...  

Heavy metal contamination is among the globally environmental and ecological concerns. In this study we assessed the development of the two green algae Schroederia setigera and Selenastrum bibraianum under exposures to 5 – 200 µg/L of Ni, Zn, and Cd in the laboratory conditions. Heavy metal removal efficiency of S. setigera was also tested in 537 µg Ni/L, 734 µg Zn/L, and 858 µg Cd/L. We found that the exposures with these heavy metals caused inhibitory on the growth of S. bibraianum. The S. bibraianum cell size in the 200 µg Zn/L treatment was around two times smaller than the control. However, Zn and Cd at the concentration of 200 µg/L did not inhibit the growth of S. setigera over 18 days of exposure. The S. setigera also grew well during 8 days exposed to Ni at the same concentration. Besides, the alga S. setigera could remove 66% of Zn, 18% of Cd and 12% of Ni out of the test medium after 16 days of incubation. The Vietnam Technical Regulation related to metals should be considered for ecological protection. We recommend to test the metal removal by the alga S. setigera at pilot scale prior to apply it in situ


2018 ◽  
Vol 1 (3) ◽  
Author(s):  
Nusa Idaman Said ◽  
Firly Firly

An experiment of anaerobic biofilter using honeycomb plastic media was conducted in semi-pilot scale. This paper describes the pilot plan study of chicken’s slaughterhouse wastewater treatment using anaerobic and aerobic submerged biofilter using honeycomb plastic media. The main research was conducting by continuous operation under condition 4 days, 2 days and 1 day retention time. The result of experiment shows that within the anaerobic process under conditions 1- 4 days retention time, the removal efficiency of COD were 78 – 87 %, BOD  were 78 – 89   %, 73 – 83 % , and Total Suspended Solids (TSS) were 83 – 96 %  respectively.  Using combined anaerobic and aerobic process under same conditions 1 - 4 days retention time shows increasing of removal efficiency.  The removal efficiency of COD were 86 – 90 %, BOD were 85 – 90 %, Organics (KMnO4) were 81 – 88 % and Total Suspended Solids (TSS) were 94 – 96 % respectively.  The longer retention time has resulted in higher removal efficiency. Kata Kunci : Biofilter anaerobik, media sarang tawon, air limbah, rumah potong ayam.


2017 ◽  
Vol 75 (11) ◽  
pp. 2598-2606 ◽  
Author(s):  
B. Rusten ◽  
S. S. Rathnaweera ◽  
E. Rismyhr ◽  
A. K. Sahu ◽  
J. Ntiako

Fine mesh rotating belt sieves (RBS) offer a very compact solution for removal of particles from wastewater. This paper shows examples from pilot-scale testing of primary treatment, chemically enhanced primary treatment (CEPT) and secondary solids separation of biofilm solids from moving bed biofilm reactors (MBBRs). Primary treatment using a 350 microns belt showed more than 40% removal of total suspended solids (TSS) and 30% removal of chemical oxygen demand (COD) at sieve rates as high as 160 m³/m²-h. Maximum sieve rate tested was 288 m³/m²-h and maximum particle load was 80 kg TSS/m²-h. When the filter mat on the belt increased from 10 to 55 g TSS/m², the removal efficiency for TSS increased from about 35 to 60%. CEPT is a simple and effective way of increasing the removal efficiency of RBS. Adding about 1 mg/L of cationic polymer and about 2 min of flocculation time, the removal of TSS typically increased from 40–50% without polymer to 60–70% with polymer. Using coagulation and flocculation ahead of the RBS, separation of biofilm solids was successful. Removal efficiencies of 90% TSS, 83% total P and 84% total COD were achieved with a 90 microns belt at a sieve rate of 41 m³/m²-h.


Processes ◽  
2019 ◽  
Vol 7 (7) ◽  
pp. 418 ◽  
Author(s):  
Pedro Cisterna-Osorio ◽  
Verónica Lazcano-Castro ◽  
Gisela Silva-Vasquez ◽  
Mauricio Llanos-Baeza ◽  
Ignacio Fuentes-Ortega

The objective of this work is to evaluate the impact of innovative modifications made to conventional effluent capture and discharge devices used in subsurface flow wetlands (SSFW). The main modifications that have been developed extend the influence of the capture and discharge device in such a way that the SSFW width and height are fully covered. This improved innovative device was applied and evaluated in two subsurface flow wetlands, one on a pilot scale and one on a real scale. To evaluate the impact of the innovative device with respect to the conventional one in the operational functioning of subsurface flow wetlands, the elimination of chemical oxygen demand (COD) was measured and compared. The results show that for the innovative device, the COD removal was 10% higher than for the conventional device, confirming the validity and effectiveness of the modifications implemented in the effluent capture and discharge devices used in SSFW.


2000 ◽  
Vol 41 (1) ◽  
pp. 57-63 ◽  
Author(s):  
S. Vandaele ◽  
C. Thoeye ◽  
B. Van Eygen ◽  
G. De Gueldre

In Flanders (Belgium) an estimated 15% of the population will never be connected to a central wastewater treatment plant (WWTP). Small WWTPs can be a valuable option. Aquafin bases the decision to build SWWTPs on a drainage area study. To realise an accelerated construction the process choice is made accordingly to a standard matrix, which represents the different technologies in function of the size and the effluent consents. A pilot scale constructed two-stage reed bed is used to optimise the concept of the reed beds. The concept consists of a primary clarifier, two parallel vertical flow reed beds followed by a sub-surface flow reed bed. The removal efficiency of organic pollutants is high (COD: 89%, BOD: 98%). Phosphorus removal is high at the start-up but diminishes throughout the testing period (from 100% to 71% retention after 7 months). Nitrogen removal amounts to 53% on average. Nitrification is complete in summer. Denitrification appears to be the limiting factor. In autumn leakage of nitrogen is assumed. Removal efficiency of pathogens amounts to almost 99%. Clogging forms a substantial constraint of the vertical flow reed bed. Problems appear to be related with presettlement, feed interval and geotextile.


2019 ◽  
Vol 79 (4) ◽  
pp. 771-778 ◽  
Author(s):  
Junho Lee ◽  
Myungjin Lee

Abstract This study has been carried out to evaluate the applicability of the pilot scale hybrid type of stormwater runoff treatment system for treatment of combined sewer overflow. Also, to determine the optimum operation parameter such as coagulation dosage concentration, effectiveness of coagulant usage, surface loading rate and backwashing conditions. The pilot scale stormwater filtration system (SFS) was installed at the municipal wastewater plant serving the city of Cheongju (CWTP), Korea. CWTP has a capacity of 280,000 m3/day. The SFS consists of a hydrocyclone coagulation/flocculation with polyaluminium chloride silicate (PACS) and an upflow filter to treat combined sewer overflows. There are two modes (without PACS use and with PACS use) of operation for the SFS. In case of no coagulant use, the range of suspended solids (SS) and turbidity removal efficiency were 72.0–86.6% (mean 80.0%) and 30.9–71.1% (mean 49.3%), respectively. And, the recovery rate of filter was 79.2–83.6% (mean 81.2%); the rate of remaining solid loading in filter media was 16.4–20.8% (mean 18.8%) after backwashing. The influent turbidity, SS concentrations were 59.0–90.7 NTU (mean 72.0 NTU), 194.0–320.0mg/L (mean 246.7mg/L), respectively. The range of PACS dosage concentration was 6.0–7.1mg/L (mean 6.7mg/L). The range of SS and turbidity removal efficiency was 84.9–98.2 (mean 91.4%) and 70.7–96.3 (mean 84.0%), respectively. It was found that removal efficiency was enhanced with PACS dosage. The recovery rate of filter was 92.0–92.5% (mean 92.3%) the rate of remaining solid loading in filter media was 6.1–8.2% (mean 7.2%) after backwashing. In the case of coagulant use, the particle size of the effluent is bigger than influent particle size. The results showed that SFS with PACS use more effective than without PACS use in SS and turbidity removal efficiency and recovery rate of filter.


2001 ◽  
Vol 43 (8) ◽  
pp. 195-201 ◽  
Author(s):  
K. Park ◽  
J.-M. Cho ◽  
J. Oh ◽  
K. Chung

This study was conducted to show the influence of upward velocity in the inner column and downward velocity in the outer column of the coaxial cylinder-type flotation column on the solids removal efficiency, solids concentration in the treated water, and so on. The SIMPLE (Semi-Implicit Method for Pressure Linked Equation) solution was applied to the coaxial flotation column to simulate the velocity vectors of the elements of water flowing in the column. The effects of solids loading and residence time in the agglomerate separation zone on the solids removal efficiency were also tested. In the pilot scale coaxial DAF column experiments with solids concentration of 1,000–2,000 mg of SS per liter and solids loading less than 350 kg/m2/day, approximately 90% of the solids removal efficiencies were obtained using the upward velocity of up to 110 cm/min in the contact zone of the inner column and the downward velocity of up to 30 cm/min in the outer column. In the simulation, similar results were observed as in the experiments. The solids loading in the excess of 350 kg/m2/day caused the instability of the sludge float layer and aggravated the quality of the treated water.


Sign in / Sign up

Export Citation Format

Share Document