Determination of optimal operating factors via modeling for livestock wastewater treatment: Comparison of simulated and experimental data

2014 ◽  
Vol 95 ◽  
pp. 46-54 ◽  
Author(s):  
Jae Young Ahn ◽  
Kyoung Hoon Chu ◽  
Sung Soo Yoo ◽  
Ji Sung Mang ◽  
Baek Woo Sung ◽  
...  
1992 ◽  
Vol 26 (1-2) ◽  
pp. 407-415 ◽  
Author(s):  
D. A. Barton ◽  
J. J. McKeown ◽  
W. Chudyk

A model of organic compound removal by biological wastewater treatment processes receiving pulp and paper industry wastewaters has been developed and initial model verification performed at a single mill site. This paper presents the results of further model verification conducted at multiple mill sites, including replication of the original site. In addition, VOC losses at other unit processes are quantified. Activated sludge basin chloroform volatilization rates are predicted to within twelve percent of the measured rates. Predicted overall methanol removals are consistent with observed removals although difficulties encountered during off-gas sampling preclude determination of the extent of removal due to volatilization.


1998 ◽  
Vol 38 (2) ◽  
pp. 9-15 ◽  
Author(s):  
J. Guan ◽  
T. D. Waite ◽  
R. Amal ◽  
H. Bustamante ◽  
R. Wukasch

A rapid method of determining the structure of aggregated particles using small angle laser light scattering is applied here to assemblages of bacteria from wastewater treatment systems. The structure information so obtained is suggestive of fractal behaviour as found by other methods. Strong dependencies are shown to exist between the fractal structure of the bacterial aggregates and the behaviour of the biosolids in zone settling and dewatering by both pressure filtration and centrifugation methods. More rapid settling and significantly higher solids contents are achievable for “looser” flocs characterised by lower fractal dimensions. The rapidity of determination of structural information and the strong dependencies of the effectiveness of a number of wastewater treatment processes on aggregate structure suggests that this method may be particularly useful as an on-line control tool.


1992 ◽  
Vol 57 (9) ◽  
pp. 1905-1914
Author(s):  
Miroslav Bleha ◽  
Věra Šumberová

The equilibrium sorption of uni-univalent electrolytes (NaCl, KCl) in heterogeneous cation exchange membranes with various contents of the ion exchange component and in ion exchange membranes Ralex was investigated. Using experimental data which express the concentration dependence of equilibrium sorption, validity of the Donnan relation for the systems under investigation was tested and values of the Glueckauf inhomogeneity factor for Ralex membranes were determined. Determination of the equilibrium sorption allows the effect of the total content of internal water and of the ion-exchange capacity on the distribution coefficients of the electrolyte to be determined.


Author(s):  
Emre Kahramanoglu ◽  
Silvia Pennino ◽  
Huseyin Yilmaz

The hydrodynamic characteristics of the planing hulls in particular at the planing regime are completely different from the conventional hull forms and the determination of these characteristics is more complicated. In the present study, calm water hydrodynamic characteristics of planing hulls are investigated using a hybrid method. The hybrid method combines the dynamic trim and sinkage from the Zarnick approach with the Savitsky method in order to calculate the total resistance of the planing hull. Since the obtained dynamic trim and sinkage values by using the original Zarnick approach are not in good agreement with experimental data, an improvement is applied to the hybrid method using a reduction function proposed by Garme. The numerical results obtained by the hybrid and improved hybrid method are compared with each other and available experimental data. The results indicate that the improved hybrid method gives better results compared to the hybrid method, especially for the dynamic trim and resistance. Although the results have some discrepancies with experimental data in terms of resistance, trim and sinkage, the improved hybrid method becomes appealing particularly for the preliminary design stage of the planing hulls.


2021 ◽  
Vol 13 (13) ◽  
pp. 7358
Author(s):  
Dong-Hyun Kim ◽  
Hyun-Sik Yun ◽  
Young-Saeng Kim ◽  
Jong-Guk Kim

This study analyzed the microbial community metagenomically to determine the cause of the functionality of a livestock wastewater treatment facility that can effectively remove pollutants, such as ammonia and hydrogen sulfide. Illumina MiSeq sequencing was used in analyzing the composition and structure of the microbial community, and the 16S rRNA gene was used. Through Illumina MiSeq sequencing, information such as diversity indicators as well as the composition and structure of microbial communities present in the livestock wastewater treatment facility were obtained, and differences between microbial communities present in the investigated samples were compared. The number of reads, operational taxonomic units, and species richness were lower in influent sample (NLF), where the wastewater enters, than in effluent sample (NL), in which treated wastewater is found. This difference was greater in June 2019 than in January 2020, and the removal rates of ammonia (86.93%) and hydrogen sulfide (99.72%) were also higher in June 2019. In both areas, the community composition was similar in January 2020, whereas the influent sample (NLF) and effluent sample (NL) areas in June 2019 were dominated by Proteobacteria (76.23%) and Firmicutes (67.13%), respectively. Oleiphilaceae (40.89%) and Thioalkalibacteraceae (12.91%), which are related to ammonia and hydrogen sulfide removal, respectively, were identified in influent sample (NLF) in June 2019. They were more abundant in June 2019 than in January 2020. Therefore, the functionality of the livestock wastewater treatment facility was affected by characteristics, including the composition of the microbial community. Compared to Illumina MiSeq sequencing, fewer species were isolated and identified in both areas using culture-based methods, suggesting Illumina MiSeq sequencing as a powerful tool to determine the relevance of microbial communities for pollutant removal.


2021 ◽  
Vol 232 (4) ◽  
Author(s):  
Bui Quoc Lap ◽  
Nguyen Vu Duc Thinh ◽  
Nguyen Tri Quang Hung ◽  
Nguyen Hoai Nam ◽  
Huyen Thi Thanh Dang ◽  
...  

1993 ◽  
Vol 16 (2) ◽  
pp. 63-70 ◽  
Author(s):  
N.A. Hoenich ◽  
P.T. Smirthwaite ◽  
C. Woffindin ◽  
P. Lancaster ◽  
T.H. Frost ◽  
...  

Recirculation is an important factor in single needle dialysis and, if high, can compromise treatment efficiency. To provide information regarding recirculation characteristics of access devices used in single needle dialysis, we have developed a new technique to characterise recirculation and have used this to measure the recirculation of a Terumo 15G fistula needle and a VasCath SC2300 single lumen catheter. The experimentally obtained results agreed well with those established clinically (8.5 ± 2.4% and 18.4 ± 3.4%). The experimental results have also demonstrated a dependence on access type, pump speeds and fistula flow rate. A comparison of experimental data with theoretical predictions showed that the latter exceeded those measured with the largest contribution being due to the experimental fistula.


Sign in / Sign up

Export Citation Format

Share Document