scholarly journals Improved fluid search optimization-based real-time weed mapping

2020 ◽  
Vol 7 (3) ◽  
pp. 403-417
Author(s):  
Chengcheng Chen ◽  
Shengsheng Wang ◽  
Xianchang Wang ◽  
Helong Yu ◽  
Ruyi Dong
Sensors ◽  
2018 ◽  
Vol 18 (12) ◽  
pp. 4245 ◽  
Author(s):  
Yanlei Xu ◽  
Zongmei Gao ◽  
Lav Khot ◽  
Xiaotian Meng ◽  
Qin Zhang

This study developed and field tested an automated weed mapping and variable-rate herbicide spraying (VRHS) system for row crops. Weed detection was performed through a machine vision sub-system that used a custom threshold segmentation method, an improved particle swarm optimum (IPSO) algorithm, capable of segmenting the field images. The VRHS system also used a lateral histogram-based algorithm for fast extraction of weed maps. This was the basis for determining real-time herbicide application rates. The central processor of the VRHS system had high logic operation capacity, compared to the conventional controller-based systems. Custom developed monitoring system allowed real-time visualization of the spraying system functionalities. Integrated system performance was then evaluated through field experiments. The IPSO successfully segmented weeds within corn crop at seedling growth stage and reduced segmentation error rates to 0.1% from 7.1% of traditional particle swarm optimization algorithm. IPSO processing speed was 0.026 s/frame. The weed detection to chemical actuation response time of integrated system was 1.562 s. Overall, VRHS system met the real-time data processing and actuation requirements for its use in practical weed management applications.


2020 ◽  
Vol 10 (20) ◽  
pp. 7132 ◽  
Author(s):  
Jizhong Deng ◽  
Zhaoji Zhong ◽  
Huasheng Huang ◽  
Yubin Lan ◽  
Yuxing Han ◽  
...  

The timely and efficient generation of weed maps is essential for weed control tasks and precise spraying applications. Based on the general concept of site-specific weed management (SSWM), many researchers have used unmanned aerial vehicle (UAV) remote sensing technology to monitor weed distributions, which can provide decision support information for precision spraying. However, image processing is mainly conducted offline, as the time gap between image collection and spraying significantly limits the applications of SSWM. In this study, we conducted real-time image processing onboard a UAV to reduce the time gap between image collection and herbicide treatment. First, we established a hardware environment for real-time image processing that integrates map visualization, flight control, image collection, and real-time image processing onboard a UAV based on secondary development. Second, we exploited the proposed model design to develop a lightweight network architecture for weed mapping tasks. The proposed network architecture was evaluated and compared with mainstream semantic segmentation models. Results demonstrate that the proposed network outperform contemporary networks in terms of efficiency with competitive accuracy. We also conducted optimization during the inference process. Precision calibration was applied to both the desktop and embedded devices and the precision was reduced from FP32 to FP16. Experimental results demonstrate that this precision calibration further improves inference speed while maintaining reasonable accuracy. Our modified network architecture achieved an accuracy of 80.9% on the testing samples and its inference speed was 4.5 fps on a Jetson TX2 module (Nvidia Corporation, Santa Clara, CA, USA), which demonstrates its potential for practical agricultural monitoring and precise spraying applications.


2018 ◽  
Vol 12 (4) ◽  
pp. 4161-4179
Author(s):  
Mohamed. A. Shamseldin ◽  
Mohamed Sallam ◽  
A. M. Bassiuny ◽  
A. M. Abdel Ghany

This paper presents a real-time implementation of an enhanced nonlinear PID (NPID) controller to follow a preselected position profile of one stage servomechanism drive system. This purpose should be realized regardless the different operating points and external disorders (friction and backlash). In this study, the MATLAB Simulink used for purpose of controller design while the result from simulation will be executed in real time using LABVIEW software. There is not enough information about the servomechanism experimental setup so, the system identification techniques will be used via collecting experimental input/output data. The optimum parameters for the controllers have been obtained via harmony search optimization technique according to an effective cost function. Also, the performance of enhanced NPID controller has been investigated by comparing it with linear PID controller.  The experimental and simulation results show that the proposed NPID controller has minimum rise time and settling time through constant position reference test. Also, the NPID control is faster than the linear PID control by 40% in case of variable position reference test.


1979 ◽  
Vol 44 ◽  
pp. 41-47
Author(s):  
Donald A. Landman

This paper describes some recent results of our quiescent prominence spectrometry program at the Mees Solar Observatory on Haleakala. The observations were made with the 25 cm coronagraph/coudé spectrograph system using a silicon vidicon detector. This detector consists of 500 contiguous channels covering approximately 6 or 80 Å, depending on the grating used. The instrument is interfaced to the Observatory’s PDP 11/45 computer system, and has the important advantages of wide spectral response, linearity and signal-averaging with real-time display. Its principal drawback is the relatively small target size. For the present work, the aperture was about 3″ × 5″. Absolute intensity calibrations were made by measuring quiet regions near sun center.


Author(s):  
Alan S. Rudolph ◽  
Ronald R. Price

We have employed cryoelectron microscopy to visualize events that occur during the freeze-drying of artificial membranes by employing real time video capture techniques. Artificial membranes or liposomes which are spherical structures within internal aqueous space are stabilized by water which provides the driving force for spontaneous self-assembly of these structures. Previous assays of damage to these structures which are induced by freeze drying reveal that the two principal deleterious events that occur are 1) fusion of liposomes and 2) leakage of contents trapped within the liposome [1]. In the past the only way to access these events was to examine the liposomes following the dehydration event. This technique allows the event to be monitored in real time as the liposomes destabilize and as water is sublimed at cryo temperatures in the vacuum of the microscope. The method by which liposomes are compromised by freeze-drying are largely unknown. This technique has shown that cryo-protectants such as glycerol and carbohydrates are able to maintain liposomal structure throughout the drying process.


Author(s):  
R.P. Goehner ◽  
W.T. Hatfield ◽  
Prakash Rao

Computer programs are now available in various laboratories for the indexing and simulation of transmission electron diffraction patterns. Although these programs address themselves to the solution of various aspects of the indexing and simulation process, the ultimate goal is to perform real time diffraction pattern analysis directly off of the imaging screen of the transmission electron microscope. The program to be described in this paper represents one step prior to real time analysis. It involves the combination of two programs, described in an earlier paper(l), into a single program for use on an interactive basis with a minicomputer. In our case, the minicomputer is an INTERDATA 70 equipped with a Tektronix 4010-1 graphical display terminal and hard copy unit.A simplified flow diagram of the combined program, written in Fortran IV, is shown in Figure 1. It consists of two programs INDEX and TEDP which index and simulate electron diffraction patterns respectively. The user has the option of choosing either the indexing or simulating aspects of the combined program.


Author(s):  
R. Rajesh ◽  
R. Droopad ◽  
C. H. Kuo ◽  
R. W. Carpenter ◽  
G. N. Maracas

Knowledge of material pseudodielectric functions at MBE growth temperatures is essential for achieving in-situ, real time growth control. This allows us to accurately monitor and control thicknesses of the layers during growth. Undesired effusion cell temperature fluctuations during growth can thus be compensated for in real-time by spectroscopic ellipsometry. The accuracy in determining pseudodielectric functions is increased if one does not require applying a structure model to correct for the presence of an unknown surface layer such as a native oxide. Performing these measurements in an MBE reactor on as-grown material gives us this advantage. Thus, a simple three phase model (vacuum/thin film/substrate) can be used to obtain thin film data without uncertainties arising from a surface oxide layer of unknown composition and temperature dependence.In this study, we obtain the pseudodielectric functions of MBE-grown AlAs from growth temperature (650°C) to room temperature (30°C). The profile of the wavelength-dependent function from the ellipsometry data indicated a rough surface after growth of 0.5 μm of AlAs at a substrate temperature of 600°C, which is typical for MBE-growth of GaAs.


Author(s):  
K. Harada ◽  
T. Matsuda ◽  
J.E. Bonevich ◽  
M. Igarashi ◽  
S. Kondo ◽  
...  

Previous observations of magnetic flux-lines (vortex lattices) in superconductors, such as the field distribution of a flux-line, and flux-line dynamics activated by heat and current, have employed the high spatial resolution and magnetic sensitivity of electron holography. And recently, the 2-D static distribution of vortices was also observed by this technique. However, real-time observations of the vortex lattice, in spite of scientific and technological interest, have not been possible due to experimental difficulties. Here, we report the real-time observation of vortex lattices in a thin superconductor, by means of Lorentz microscopy using a 300 kV field emission electron microscope. This technique allows us to observe the dynamic motion of individual vortices and record the events on a VTR system.The experimental arrangement is shown in Fig. 1. A Nb thin film for transmission observation was prepared by chemical etching. The grain size of the film was increased by annealing, and single crystals were observed with a thickness of 50∼90 nm.


2001 ◽  
Vol 7 (S2) ◽  
pp. 1012-1013
Author(s):  
Uyen Tram ◽  
William Sullivan

Embryonic development is a dynamic event and is best studied in live animals in real time. Much of our knowledge of the early events of embryogenesis, however, comes from immunofluourescent analysis of fixed embryos. While these studies provide an enormous amount of information about the organization of different structures during development, they can give only a static glimpse of a very dynamic event. More recently real-time fluorescent studies of living embryos have become much more routine and have given new insights to how different structures and organelles (chromosomes, centrosomes, cytoskeleton, etc.) are coordinately regulated. This is in large part due to the development of commercially available fluorescent probes, GFP technology, and newly developed sensitive fluorescent microscopes. For example, live confocal fluorescent analysis proved essential in determining the primary defect in mutations that disrupt early nuclear divisions in Drosophila melanogaster. For organisms in which GPF transgenics is not available, fluorescent probes that label DNA, microtubules, and actin are available for microinjection.


2019 ◽  
Vol 4 (2) ◽  
pp. 356-362
Author(s):  
Jennifer W. Means ◽  
Casey McCaffrey

Purpose The use of real-time recording technology for clinical instruction allows student clinicians to more easily collect data, self-reflect, and move toward independence as supervisors continue to provide continuation of supportive methods. This article discusses how the use of high-definition real-time recording, Bluetooth technology, and embedded annotation may enhance the supervisory process. It also reports results of graduate students' perception of the benefits and satisfaction with the types of technology used. Method Survey data were collected from graduate students about their use and perceived benefits of advanced technology to support supervision during their 1st clinical experience. Results Survey results indicate that students found the use of their video recordings useful for self-evaluation, data collection, and therapy preparation. The students also perceived an increase in self-confidence through the use of the Bluetooth headsets as their supervisors could provide guidance and encouragement without interrupting the flow of their therapy sessions by entering the room to redirect them. Conclusions The use of video recording technology can provide opportunities for students to review: videos of prospective clients they will be treating, their treatment videos for self-assessment purposes, and for additional data collection. Bluetooth technology provides immediate communication between the clinical educator and the student. Students reported that the result of that communication can improve their self-confidence, perceived performance, and subsequent shift toward independence.


Sign in / Sign up

Export Citation Format

Share Document