Analytical techniques from individual proteins to whole cells

2001 ◽  
Vol 0 (0) ◽  
pp. 0
Author(s):  
C Robinson
2021 ◽  
Author(s):  
Mark Harrison Smith

This dissertation examines the fundamental principles and applicability of the kinetic exclusion assay (KinExA), developed and marketed by Sapidyne Instruments of Boise, Idaho, since 1995. Chapter One reviews and consolidates the manufacturer’s guidance and many early papers that delineate the practical and theoretical aspects of the technology. In brief, KinExA is a two stage analytical system. In stage one, a number of solutions are prepared, whereby one of the partners is kept constant (the constant binding partner, or CBP), while the other (the titrant) is varied, usually in serial dilution. As the titrant is increased, the free CBP decreases, and is analyzed by a sophisticated and precise microfluidic fluorometric device (stage two). The resulting signal can be related mathematically to the affinity (KD) of the two molecules for each other, and to the kinetic parameters of binding (kon) and dissociation (koff). A comparison of KinExA with other current technology available for quantification of interactions is provided. In Chapter Two, I investigate the use of KinExA technology with DNA aptamers. DNA aptamers are short nucleotide oligomers selected to bind a target ligand with affinity and specificity rivaling that of antibodies. These remarkable features make them promising alternatives for analytical and therapeutic applications that traditionally use antibodies as biorecognition elements. Numerous traditional and emerging analytical techniques have been proposed and successfully implemented to utilize aptamers for sensing purposes. In this work, I exploited the analytical capabilities offered by the KinExA technology to measure the affinity of fluorescent aptamers for their target molecule thrombin, and quantify the concentration of analyte in solution. Standard binding curves constructed by using equilibrated mixtures of aptamers titrated with thrombin were fitted with a 1:1 binding model and provided an effective KD of the binding in the sub-nanomolar range. However, the experimental results suggest that this simple model does not satisfactorily describe the binding process; therefore, the possibility that the aptamer is composed of a mixture of two or more distinct KD populations is discussed. The same standard curves, together with a four-parameter logistic equation, were used to determine “unknown” concentrations of thrombin in mock samples. The ability to identify and characterize complex binding stoichiometry, together with the determination of target analyte concentrations in the pM–nM range, supports the adoption of this technology for kinetics, equilibrium, and analytical purposes by employing aptamers as biorecognition elements. In Chapter Three, I explore complex capture agents in the KinExA system. Liposomes made from purified reagents, or from natural cellular membranes, are attached to the beads used in the KinExA process to capture the analyte. Model molecules representing lipophilic dyes, antibodies, and bacterial toxins were successfully captured by the beads for measurement. Residual free ligand captured after pre-equilibration with membrane components, presented as either liposomes or whole cells, could be quantified, and kinetic parameters determined. By this process the “bi-molecular” interaction of the B subunit of cholera toxin for the ganglioside GM1 incorporated into artificial membranes could be quantified, and shown to be dependent upon the presence of the ganglioside in the membrane. The diffusion into artificial membranes of the lipophilic dye DID could be quantified and shown to be dependent upon the amount of lipid available in the equilibration step. In addition, the bulk affinity of a commercial polyclonal antibody for the surface antigens of their target red blood cells could be evaluated. This membrane immobilization process appears to be generally applicable to any membrane system. Thus, it promises to be valuable for the study of signaling molecules for which purified soluble target cellular components may result in misleading information, or for which soluble fragments are unavailable. Likewise, this process should aid in the search for drugs which mimic or antagonize these signaling ligands.


Author(s):  
R. E. Herfert

Studies of the nature of a surface, either metallic or nonmetallic, in the past, have been limited to the instrumentation available for these measurements. In the past, optical microscopy, replica transmission electron microscopy, electron or X-ray diffraction and optical or X-ray spectroscopy have provided the means of surface characterization. Actually, some of these techniques are not purely surface; the depth of penetration may be a few thousands of an inch. Within the last five years, instrumentation has been made available which now makes it practical for use to study the outer few 100A of layers and characterize it completely from a chemical, physical, and crystallographic standpoint. The scanning electron microscope (SEM) provides a means of viewing the surface of a material in situ to magnifications as high as 250,000X.


Author(s):  
R.W. Horne

The technique of surrounding virus particles with a neutralised electron dense stain was described at the Fourth International Congress on Electron Microscopy, Berlin 1958 (see Home & Brenner, 1960, p. 625). For many years the negative staining technique in one form or another, has been applied to a wide range of biological materials. However, the full potential of the method has only recently been explored following the development and applications of optical diffraction and computer image analytical techniques to electron micrographs (cf. De Hosier & Klug, 1968; Markham 1968; Crowther et al., 1970; Home & Markham, 1973; Klug & Berger, 1974; Crowther & Klug, 1975). These image processing procedures have allowed a more precise and quantitative approach to be made concerning the interpretation, measurement and reconstruction of repeating features in certain biological systems.


Author(s):  
Simon Thomas

Trends in the technology development of very large scale integrated circuits (VLSI) have been in the direction of higher density of components with smaller dimensions. The scaling down of device dimensions has been not only laterally but also in depth. Such efforts in miniaturization bring with them new developments in materials and processing. Successful implementation of these efforts is, to a large extent, dependent on the proper understanding of the material properties, process technologies and reliability issues, through adequate analytical studies. The analytical instrumentation technology has, fortunately, kept pace with the basic requirements of devices with lateral dimensions in the micron/ submicron range and depths of the order of nonometers. Often, newer analytical techniques have emerged or the more conventional techniques have been adapted to meet the more stringent requirements. As such, a variety of analytical techniques are available today to aid an analyst in the efforts of VLSI process evaluation. Generally such analytical efforts are divided into the characterization of materials, evaluation of processing steps and the analysis of failures.


Author(s):  
S. Edith Taylor ◽  
Patrick Echlin ◽  
May McKoon ◽  
Thomas L. Hayes

Low temperature x-ray microanalysis (LTXM) of solid biological materials has been documented for Lemna minor L. root tips. This discussion will be limited to a demonstration of LTXM for measuring relative elemental distributions of P,S,Cl and K species within whole cells of tobacco leaves.Mature Wisconsin-38 tobacco was grown in the greenhouse at the University of California, Berkeley and picked daily from the mid-stalk position (leaf #9). The tissue was excised from the right of the mid rib and rapidly frozen in liquid nitrogen slush. It was then placed into an Amray biochamber and maintained at 103K. Fracture faces of the tissue were prepared and carbon-coated in the biochamber. The prepared sample was transferred from the biochamber to the Amray 1000A SEM equipped with a cold stage to maintain low temperatures at 103K. Analyses were performed using a tungsten source with accelerating voltages of 17.5 to 20 KV and beam currents from 1-2nA.


Author(s):  
M.P. Thomas ◽  
A.R. Waugh ◽  
M.J. Southon ◽  
Brian Ralph

It is well known that ion-induced sputtering from numerous multicomponent targets results in marked changes in surface composition (1). Preferential removal of one component results in surface enrichment in the less easily removed species. In this investigation, a time-of-flight atom-probe field-ion microscope A.P. together with X-ray photoelectron spectroscopy XPS have been used to monitor alterations in surface composition of Ni3Al single crystals under argon ion bombardment. The A.P. has been chosen for this investigation because of its ability using field evaporation to depth profile through a sputtered surface without the need for further ion sputtering. Incident ion energy and ion dose have been selected to reflect conditions widely used in surface analytical techniques for cleaning and depth-profiling of samples, typically 3keV and 1018 - 1020 ion m-2.


Author(s):  
J. I. Bennetch

In a recent study of the superplastic forming (SPF) behavior of certain Al-Li-X alloys, the relative misorientation between adjacent (sub)grains proved to be an important parameter. It is well established that the most accurate way to determine misorientation across boundaries is by Kikuchi line analysis. However, the SPF study required the characterization of a large number of (sub)grains in each sample to be statistically meaningful, a very time-consuming task even for comparatively rapid Kikuchi analytical techniques.In order to circumvent this problem, an alternate, even more rapid in-situ Kikuchi technique was devised, eliminating the need for the developing of negatives and any subsequent measurements on photographic plates. All that is required is a double tilt low backlash goniometer capable of tilting ± 45° in one axis and ± 30° in the other axis. The procedure is as follows. While viewing the microscope screen, one merely tilts the specimen until a standard recognizable reference Kikuchi pattern is centered, making sure, at the same time, that the focused electron beam remains on the (sub)grain in question.


Author(s):  
Richard S. Chemock

One of the most common tasks in a typical analysis lab is the recording of images. Many analytical techniques (TEM, SEM, and metallography for example) produce images as their primary output. Until recently, the most common method of recording images was by using film. Current PS/2R systems offer very large capacity data storage devices and high resolution displays, making it practical to work with analytical images on PS/2s, thereby sidestepping the traditional film and darkroom steps. This change in operational mode offers many benefits: cost savings, throughput, archiving and searching capabilities as well as direct incorporation of the image data into reports.The conventional way to record images involves film, either sheet film (with its associated wet chemistry) for TEM or PolaroidR film for SEM and light microscopy. Although film is inconvenient, it does have the highest quality of all available image recording techniques. The fine grained film used for TEM has a resolution that would exceed a 4096x4096x16 bit digital image.


Author(s):  
W. E. Rigsby ◽  
D. M. Hinton ◽  
V. J. Hurst ◽  
P. C. McCaskey

Crystalline intracellular inclusions are rarely seen in mammalian tissues and are often difficult to positively identify. Lymph node and liver tissue samples were obtained from two cows which had been rejected at the slaughter house due to the abnormal appearance of these organs in the animals. The samples were fixed in formaldehyde and some of the fixed material was embedded in paraffin. Examination of the paraffin sections with polarized light microscopy revealed the presence of numerous crystals in both hepatic and lymph tissue sections. Tissue sections were then deparaffinized in xylene, mounted, carbon coated, and examined in a Phillips 505T SEM equipped with a Tracor Northern X-ray Energy Dispersive Spectroscopy (EDS) system. Crystals were obscured by cellular components and membranes so that EDS spectra were only obtainable from whole cells. Tissue samples which had been fixed but not paraffin-embedded were dehydrated, embedded in Spurrs plastic, and sectioned.


Author(s):  
Julia T. Luck ◽  
C. W. Boggs ◽  
S. J. Pennycook

The use of cross-sectional Transmission Electron Microscopy (TEM) has become invaluable for the characterization of the near-surface regions of semiconductors following ion-implantation and/or transient thermal processing. A fast and reliable technique is required which produces a large thin region while preserving the original sample surface. New analytical techniques, particularly the direct imaging of dopant distributions, also require good thickness uniformity. Two methods of ion milling are commonly used, and are compared below. The older method involves milling with a single gun from each side in turn, whereas a newer method uses two guns to mill from both sides simultaneously.


Sign in / Sign up

Export Citation Format

Share Document